# ###################################################################################################### # Do not use data message with change interval in here, it affects the instructions update performance. # # ###################################################################################################### # multiple value reserved blocks can be used even in each line. # format is as the following (look at the Messages_List.xlsx for the id and parameters): # {:::} # extra string can be used for unit(mL) which also accepts space # In case extra string or precision is not being used leave it empty eg. {77:1::} # the format shall always have three ':' and message id and parameter number shall not be ignored. # otherwise will NOT be identified as a value reserved block and will be used as part of the string. # Entry format: # [^] # "Title" = # <Instruction step> = <image.png> # - OR - # [<Prefix '$' for HDF mode><Step Tite>] # "Title" = <Title string> # <Instruction step> = <image.png> # Rich Text is supported: # ex: # <b></b> - bold # <i></i> - italic # <u> - underlined text # <$HEX>text</$> - color text // Ex. <$2268FF>TEST</$> - Do not add '0x' to HEX value # ###################################################################################################### [Concentrates] Title = Connect Acid Concentrate and Dry Bicarbonate Cartridge Disconnect <$B53333>red</$> acid straw and connect to acid concentrate. = Concentrates_1.png Pull the <$#2268FF>blue </$> bicarbonate knob upwards and insert the dry bicarbonate cartridge. = Concentrates_2.png [Installation^Blood Tubing Set] Title = Install Blood Tubing Set Open the blood pump door. = Installation_BloodTube_1.png Insert blood tubing bracket into the clip. Push inwards and ensure it is secure. = Installation_BloodTube_2.png Close the blood pump door. = Installation_BloodTube_3.png Press <b>'Auto-Load'</b> button. = Installation_BloodTube_4.png [Installation^Bloodlines] Title = Insert Bloodlines Insert saline line into the leftmost slot. = Installation_Bloodlines_1.png Insert <$B53333>arterial</$> line into the middle slot. = Installation_Bloodlines_2.png Ensure <$2268FF>venous</$> line is placed in the air detector. = Installation_Bloodlines_3.png Insert <$2268FF>venous</$> line into the rightmost slot. = Installation_Bloodlines_4.png Ensure <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines are tightened via the recirculation connector and placed behind the bar. = Installation_Bloodlines_5.png [Installation^Pressure Lines and Dialyzer] Title = Connect Pressure Lines and Dialyzer Connect <$B53333>arterial</$> pressure line to <$B53333>arterial</$> pressure transducer port. = Installation_CPLD_1.png Connect <$2268FF>venous</$> pressure line to <$2268FF>venous</$> pressure transducer port. = Installation_CPLD_2.png Connect <$2268FF>venous</$> bloodline to the top of dialyzer and <$B53333>arterial</$> line to the bottom. = Installation_CPLD_4.png Connect <$2268FF>venous</$> dialysate line to the top of dialyzer and <$B53333>arterial</$> line to the bottom. = Installation_CPLD_4.png Insert dialyzer into dialyzer holder. = Installation_CPLD_3.png Clamp heparin line and <$2268FF>venous</$> infusion line. = Installation_CPLD_6.png [Installation^Saline] Title = Connect Saline Bag Uncap and insert saline line spike into saline bag. = Saline_3.png Clamp saline line and Y-connector. = Saline_2.png Hang saline bag on the hook. = Saline_1.png [Installation^Substitution] Title = Connect Substitution Line Connect substitution line to the machine. Connect substitution line to the appropriate Pre or Post dilution port. = Saline_1.png [@Installation] Title = Install Concentrates and Blood Tubing Set Install acid concentrate and dry bicarbonate cartridge. = Install_Advanced_1.png Install blood tubing set, dialyzer, and saline bag. = Install_Advanced_2.png [@Installation^Substitution] Title = Install Concentrates and Blood Tubing Set Install acid concentrate and dry bicarbonate cartridge. = Install_Advanced_1.png Install blood tubing set, dialyzer, and connect substitution line. [Connect] Title = Connect Patient Bloodlines Wash hands and apply personal protective equipment, per policy. Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). = Connect_1.png Remove <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines from recirculation connector and attach to patient access lines. = Connect_2.png Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines and patient access lines (4 clamps). = Connect_4.png [@Connect] Title = Connect Bloodlines to the Patient Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines to patient access lines. = Connect_Advanced_1.png [Blood Return Setup] Title = Blood Return Connection Clamp <$B53333>arterial</$> bloodline and <$B53333>arterial</$> access line (2 clamps). = Return_Blood_1.png Disconnect <$B53333>arterial</$> bloodline from <$B53333>arterial</$> access line. Connect <$B53333>arterial</$> bloodline to the saline Y-connector. = Return_Blood_2.png Unclamp <$B53333>arterial</$> bloodline and saline Y-connector (2 clamps). = Return_Blood_3.png Press <b>'Start Blood Return'</b> button to begin blood return. [$Blood Return Setup] Title = Blood Return Connection Disconnect substitution line from dilution port and connect to a new, sterile recirculation connector. Clamp <$B53333>arterial</$> bloodline and <$B53333>arterial</$> access line (2 clamps). Disconnect <$B53333>arterial</$> bloodline and connect to recirculation connector. Unclamp <$B53333>arterial</$> bloodline and substitution line (2 clamps). Press <b>'Start Blood Return'</b> button to begin blood return. [Recirculate Set Up] Title = Connect Lines for Temporary Break Clamp <$2268FF>venous</$> bloodline, <$2268FF>venous</$> access line, and disconnect (2 clamps). Clamp <$B53333>arterial</$> bloodline, saline Y-connector, and disconnect (2 clamps). Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using a new, sterile recirculation connector. Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). Press <b>'Start Temporary Break'</b> button to begin the break. [$Recirculate Set Up] Title = Connect Lines for Temporary Break Clamp <$2268FF>venous</$> bloodline, <$2268FF>venous</$> access line, and disconnect (2 clamps). Clamp <$B53333>arterial</$> bloodline and disconnect from substitution line. Cap the end of the substitution port. Connect <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines using a new, recirculation connector. Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). Press <b>'Start Temporary Break'</b> button to begin the break. [Reconnect To Patient] Title = Reconnect Patient Bloodlines Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). Remove <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines from recirculation connector and connect to patient access lines. Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (4 clamps). [$Reconnect To Patient] Title = Connect Patient Bloodlines Clamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (2 clamps). Remove <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines from recirculation connector and connect to patient access lines. Unclamp <$B53333>arterial</$> and <$2268FF>venous</$> bloodlines (4 clamps). Connect substitution line to the appropriate Pre or Post dilution port. [Disconnect^Disconnect Patient BloodLines] Title = Disconnect Patient BloodLines Clamp and disconnect <$2268FF>venous</$> bloodline. = Install_Advanced_2.png Connect <$2268FF>venous</$> bloodline into <$2268FF>venous</$> needleless port. Connect <$B53333>arterial</$> bloodline into <$B53333>arterial</$> needleless port. [Remove] Title = Remove Consumables and Disposables Remove acid concentrate and dry bicarbonate cartridge as needed. Remove dialysate quick connectors and connect to the machine. Press <b>'Auto-Eject'</b> button to remove blood tubing set. Discard blood tubing set per policy.