########################################################################### # # Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. # # THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN # WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. # # @file config.py # @author (last) LTTS # @date (last) 18-Jan-2022 # ############################################################################ import os AUT_NAME = "denaliSquish" COMMON_PATH = os.environ['HOME']+"/Projects" COLOR_CODES = {"Aqua": "#81ffff", "Blue": "#017dea", "Blue 2": "#1090d5", "Green": "#29fd2d", "Grey": "#d3d3d3", "Lavender": "#db98f5", "Light Blue": "#acd7f1", "Light Teal": "#29f1da","Lime": "#b7fc36", "Magenta":"#fd28fd", "Orange": "#f2721c", "Peach":"#f1979a", "Red": "#c53b33", "Rose":"#fc178d", "Slate blue":"#7f7ffa", "Violet": "#6435c9", "White": "#ffffff", "Yellow": "#fcfc4d"} ALARM_ID_AND_MESSAGES = { 1: "Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up.", 2: "HD FPGA POST failure.", 3: "DG FPGA POST failure.", 4: "HD Watchdog POST failure.", 5: "DG Watchdog POST failure.", 6: "UI communication POST failure.\nUI failed to communicate within a reasonable time after power up.", 7: "Real-time clock configuration error.", 8: "HD accelerometer failed POST.", 9: "DG accelerometer failed POST.", 10: "RTC or MCU timer inaccurate.", 11: "DG heaters failed POST.", 12: "HD firmware image integrity POST test failed." , 13: "DG firmware image integrity POST test failed.", 14: "HD blood flow invalid calibration.", 15: "HD dialysate flow invalid calibration.", 16: "HD alarm audio failed POST.", 17: "HD UI POST failed.", 18: "DG load cells invalid calibration record.", 19: "DG flow sensors invalid calibration record.", 20: "DG conductivity sensors invalid calibration record.", 21: "DG drain line volume invalid calibration record.", 22: "DG reservoirs invalid calibration record.", 23: "DG acid concentrate calibration record.", 24: "DG bicarb concentrate calibration record.", 25: "DG accelerometer invalid calibration record.", 26: "HD accelerometer invalid calibration record.", 27: "HD blood flow invalid calibration record.", 28: "HD dialyzer flow invalid calibration record." , 29: "HD heparin force sensor invalid calibration record.", 30: "HD Software fault.\nSoftware found itself in an unexpected state.", 31: "Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", 32: "Blood pump failed motor off check.\nMeasured speed while commanded off.", 33: "Blood pump failed motor direction check.\nMeasured vs commanded.", 34: "Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds.", 35: "Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", 36: "Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off.", 37: "Dialysis inlet pump failed motor direction check.\nMeasured vs commanded.", 38: "Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", 39: "Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running.", 40: "Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off.", 41: "Dialysis outlet pump failed motor direction check.\nMeasured vs commanded.", 42: "Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds.", 43: "Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time.", 44: "User interface communication timeout.", 45: "Too many bad CRCs detected on received system messages.", 46: "System message that required acknowledgment was not acknowledged.", 47: "Ultrafiltration rate is too high error during treatment.", 48: "Ultrafiltration volume accuracy error during treatment.", 49: "HD FPGA communication down for too long." , 50: "FPGA not accepting commanded valve states.", 51: "Blood pump failed motor speed check.\nMeasured vs commanded.", 52: "Dialysate inlet pump failed motor speed check.\nMeasured vs commanded." , 53: "Dialysate outlet pump failed motor speed check.\nMeasured vs commanded.", 54: "HD critical data integrity check failed.", 55: "DG critical data integrity check failed.", 56: "HD accelerometer error (no readings or FPGA reports error).", 57: "DG accelerometer error (no readings or FPGA reports error).", 58: "HD valve homing failed.", 59: "HD valve transition time out.", 60: "HD valve not functional.", 61: "HD valve current out of range.", 62: "HD valve position out of target.", 63: "FPGA reports failure reading arterial pressure sensor.", 64: "FPGA reports failure reading venous pressure sensor.", 65: "HD requests DG command with invalid parameter fault.", 66: "HD blood leak sensor set point set failure.", 67: "HD blood pump occlusion self-test failure alarm.", 68: "HD active reservoir recirculation out of range.", 69: "HD blood leak sensor invalid calibration record.", 70: "HD arterial pressure self-test failure alarm.", 71: "HD venous pressure self-test failure alarm.", 72: "HD blood flow meter status check self-test failure alarm.", 73: "HD dialysate flow meter status check self-test failure alarm.", 74: "HD blood leak detector self-test failure alarm.", 75: "HD syringe pump self-test failure alarm.", 76: "HD monitored voltage is out of range.", 77: "DG monitored voltage is out of range.", 78: "HD syringe pump direction (from encoder) error.", 79: "HD syringe pump direction (from controller) error.", 80: "HD syringe pump fault reported by FPGA.", 81: "HD syringe pump over travel error.", 82: "HD syringe pump DAC write failure.", 83: "HD syringe pump is running while the BP is off.", 84: "HD venous pressure sensor not being read." , 85: "HD pump track latch opened alarm.", 86: "HD BP occlusion sensor not being read.", 87: "DG heating invalid calibration record.", 88: "DG concentrate pumps hall sensor out of range." , 89: "HD BP occlusion sensor error.", 90: "This alarm ID is available for use.", 91: "HD No dialysate flow data receive in the last 3 seconds.", 92: "This alarm ID is available for use." , 93: "This alarm ID is available for use.", 94: "This alarm ID is available for use." , 95: "This alarm ID is available for use." , 96: "This alarm ID is available for use.", 97: "This alarm ID is available for use.", 98: "HD battery communication fault." , 99: "HD syringe pump stall alarm.", 100: "HD no cartridge self-test timeout." , 101: "HD dry self-test timeout.", 102: "Real-time clock communication error.", 103: "HD non-volatile calibration group invalid record CRC.", 104: "Air trap level sensors reporting illegal combination of air/fluid.", 105: "DG non-volatile system group invalid record CRC.", 106: "This alarm ID is available for use.", 107: "HD reports DG restarted fault.", 108: "HD syringe pump ADC error.", 109: "HD syringe pump volume check error.", 110: "HD syringe pump speed check error.", 111: "HD syringe pump not stopped in off state error.", 112: "HD blood leak detector fault.", 113: "HD arterial air bubble detector self-test failure.", 114: "HD venous air bubble detector self-test failure.", 115: "DG temperature sensor out of range.", 116: "DG temperature sensor ADC out of range.", 117: "This alarm ID is available for use." , 118: "This alarm ID is available for use." , 119: "This alarm ID is available for use." , 120: "This alarm ID is available for use." , 121: "DG main primary heater voltage out of range.", 122: "DG small primary heater voltage out of range.", 123: "DG trimmer heater voltage out of range.", 124: "HD end of treatment alarm (high priority - user still not acting to end treatment)." , 125: "Blood sitting too long after treatment stopped by user alarm (>5 min)." , 126: "HD blood leak detected alarm.", 127: "Venous pressure too low during treatment.", 128: "HD venous air bubble detected alarm.", 129: "HD venous air bubble detected rinseback alarm." , 130: "Venous pressure too high during treatment." , 131: "Arterial pressure too low during treatment." , 132: "Arterial pressure too high during treatment.", 133: "DG fluid leak detected alarm.", 134: "HD fluid leak detected alarm." , 135: "HD experienced large acceleration." , 136: "DG experienced large acceleration.", 137: "HD tilt exceeds maximum." , 138: "DG tilt exceeds maximum.", 139: "HD AC power lost alarm." , 140: "Dialysate generator communication timeout." , 141: "Air trap fill timeout during treatment.", 142: "Blood pump occlusion detected.", 143: "DG dialysate temperature sensors drift timeout.", 144: "DG software configuration record invalid CRC.", 145: "Concentrate conductivity after adding acid out of range alarm." , 146: "Dialysate conductivity out of range." , 147: "DG dialysate generation conductivity fault alarm.", 148: "Inlet water temperature too high." , 149: "Inlet water temperature too low." , 150: "Inlet water conductivity too high." , 151: "Inlet water conductivity too low." , 152: "Inlet water pressure too low." , 153: "HD prime completed high priority alarm.", 154: "EEPROM operations (read, write, erase) failure.", 155: "DG software configuration record invalid CRC.", 156: "HW usage data (treatment time in HD and total consumed water in DG) failure.", 157: "This alarm ID is available for use." , 158: "This alarm ID is available for use.", 159: "Dialysate inlet pump failed flow vs motor speed check.", 160: "Blood pump rotor speed too high.", 161: "This alarm ID is available for use.", 162: "This alarm ID is available for use.", 163: "HD sees primary load cell for reservoir 1 change too much too fast.", 164: "HD sees primary load cell for reservoir 2 change too much too fast.", 165: "HD in treatment rinseback operation timeout.", 166: "HD in treatment re-circ sub-mode for too long." , 167: "HD cartridge door opened alarm." , 168: "HD active reservoir depletion timeout.", 169: "Dialysate flow rate out of range.", 170: "HD syringe empty alarm." , 171: "HD syringe pump occlusion alarm.", 172: "HD syringe pump not enough Heparin alarm.", 173: "HD arterial air bubble detected alarm." , 174: "HD arterial air bubble detected rinseback alarm.", 175: "HD pump direction status error.", 176: "HD active reservoir is full during treatment and DG not ready to switch reservoirs.", 177: "DG software fault.\nSoftware found itself in an unexpected state." , 178: "HD communication timeout.", 179: "DG FPGA communication down for too long." , 180: "DG load cell ADC error." , 181: "DG load cells weight out of range for tare.", 182: "DG load cells invalid calibration.", 183: "DG invalid load cell value.", 184: "Inlet or Outlet UV reactor not healthy.", 185: "DG fan RPM out of range.", 186: "DG concentrate pump fault." , 187: "DG concentrate pump CP1 speed control error.", 188: "DG concentrate pump CP2 speed control error." , 189: "DG drain pump RPM out of range.", 190: "DG drain pump off fault.", 191: "DG flow rate out of upper range." , 192: "DG flow rate out of lower range." , 193: "RO pump flow rate out of range.", 194: "DG RO pump duty cycle out of range.", 195: "DG RO pump pressure out of range.", 196: "DG temperature sensor error flag fault.", 197: "DG temperature sensors ADC fault." , 198: "DG heaters cold junction temperature out of range.", 199: "DG heaters fault." , 200: "DG thermistors/sensors temperature out of range.", 201: "Inlet water quality is bad (temperature, conductivity, pressure).", 202: "Inlet water pressure fault." , 203: "Pressure sensor fault.", 204: "RO rejection ratio out of range." , 205: "Conductivity sensor fault.", 206: "DG dialysate fill runs out of time." , 207: "DG flow meter check failure alarm.", 208: "DG primary heater on with no flow time out.", 209: "DG drain circulation line timeout.", 210: "HD battery pack detected an error." , 211: "Blood sitting too long warning (>4 min).", 212: "HD end of treatment alarm (user not acting to end treatment).", 213: "HD prime completed medium priority alarm.", 214: "HD Saline bolus volume check failure.", 215: "HD rinseback volume check failure." , 216: "HD end treatment sub-mode timeout alarm.", 217: "HD blood prime volume check failure.", 218: "HD syringe detected alarm.", 219: "HD syringe pump syringe removed alarm." , 220: "HD battery pack SOC is too low.", 221: "HD Saline bag is empty.", 222: "HD dialysate temperature too high alarm.", 223: "HD dialysate temperature too low alarm.", 224: "Treatment stopped by user action - pressed stop button.", 225: "HD end of treatment warning." , 226: "HD prime completed low priority alarm.", 227: "HD prime out of time alarm.", 228: "HD time out on prime sub-mode purge air state.", 229: "HD prime dialysate dialyzer time out alarm.", 230: "HD prime dialysate bypass time out alarm." , 231: "HD pre-treatment mode dry self-tests failure." , 232: "HD pre-treatment mode wet self-tests failure." , 233: "RTC battery low." , 234: "RTC (i.e read time) or RAM operations failure (read or write)." , 235: "HD in treatment stopped sub-mode after rinseback completed (no escalation).", 236: "HD needs new cartridge to be installed." , 237: "HD prime saline dialyzer time out alarm." , 238: "HD no cartridge loaded or installed improperly alarm." , 239: "HD fail to remove cartridge alarm." , 240: "Bicarb conductivity out of range during bicarb pump check alarm." , 241: "DG reservoir drain time out.", 242: "DG reservoir fill time out.", 243: "DG reservoir leak time out.", 244: "DG temperature sensors difference out of range.", 245: "DG heat disinfect target temperature time out (could not reach to temperature).", 246: "DG heat disinfect inlet pressure and temperature sensors out of range.", 247: "DG heat disinfect inlet conductivity and temperature out of range.", 248: "DG chemical disinfect could not reach to target temperature." , 249: "DG chemical disinfect inlet pressure and temperature sensors out of range." , 250: "DG chemical disinfect inlet conductivity and temperature out of range." , 251: "HD invalid system record." , 252: "HD invalid service record.", 253: "DG invalid system record." , 254: "DG invalid service record." , 255: "HD and UI software builds are not compatible.", 256: "HD and DG software builds are not compatible.", 257: "DG FPGA power out timeout.", 258: "HD FPGA power out timeout." , 259: "HD temperatures out of range." , 260: "UI POST Application Integrity (Sha256Sum) failure.", 261: "UI POST CANBus failure.", 262: "UI POST Display failure.", 263: "UI POST Touch failure." , 264: "UI POST SD-Card failure.", 265: "UI POST RTC failure." , 266: "UI POST WiFi failure.", 267: "UI POST Bluetooth failure.", 268: "UI POST Ethernet failure.", 269: "UI POST Sound failure." , 270: "HD POST Safety Shutdown failure.", 271: "DG POST Safety Shutdown failure." , 272: "HD Fan RPM out of range." , 273: "HD measured blood pump flow rate is out of range." , 274: "HD measured dialysate inlet pump flow rate is out of range.", 275: "HD arterial pressure sensor is reading out of range." , 276: "HD venous pressure sensor is reading out of range.", 277: "HD BP occlusion sensor is reading out of range." , 278: "HD active reservoir weight out of range." , 279: "DG dialysate drain time out." , 280: "HD arterial pressure sensor read timeout error." , 281: "Acid concentration bottle low volume alarm." , 282: "Bicarbonate concentration bottle low volume alarm." , 283: "DG load cells weight out of range." , 284: "DG load cells primary/back up drift out of range.", 285: "HD treatment recirculate timeout warning." , 286: "HD treatment rinseback complete timeout warning.", 287: "HD processor clock speed checks against FPGA clock failure.", 288: "DG trimmer heater on with flow timeout.", 289: "Total number of alarms.", 290: "ALARM_ID_UNDEFINED [{}]", } ALARM_PRIORITIES = {1: "LOW", 2: "MEDIUM", 3: "HIGH"} NUM_OF_ALARM_PRIORITIES = 4 # Total number of alarm priorities ACCEPTED = True REJECTED = False ALARM_LIST_TITLE = "Alarm list" # dictionary of rejection reason from application source code. # message location -> denali-> Headers-> common-> MsgDefs.h REJECTION_REASON = { 0: "No Active Alarm List", 1: "REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE", # Request is not allowed in the current operating mode 2: "REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM", # Validated request was not confirmed by user in reasonable time 3: "REQUEST_REJECT_REASON_NOT_IN_TREATMENT_MODE", # Request is not allowed if not in treatment mode 4: "REQUEST_REJECT_REASON_INVALID_TREATMENT_STATE", # Request is not allowed in current treatment state 5: "REQUEST_REJECT_REASON_TREATMENT_TOO_CLOSE_TO_FINISHED", # Request is not allowed so near end of treatment 6: "REQUEST_REJECT_REASON_TREATMENT_TIME_OUT_OF_RANGE", # Treatment duration is out of range 7: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_CURRENT", # Treatment time change is less than currently elapsed treatment time 8: "REQUEST_REJECT_REASON_BLOOD_FLOW_OUT_OF_RANGE", # Blood flow is out of range 9: "REQUEST_REJECT_REASON_DIAL_FLOW_OUT_OF_RANGE", # Dialysate flow is out of range 10: "REQUEST_REJECT_REASON_DIAL_VOLUME_OUT_OF_RANGE", # Dialysate flow rate or treatment duration causes dialysate volume to exceed limit 11: "REQUEST_REJECT_REASON_UF_VOLUME_OUT_OF_RANGE", # Ultrafiltration volume is out of range 12: "REQUEST_REJECT_REASON_UF_RATE_OUT_OF_RANGE", # Ultrafiltration rate is out of range 13: "REQUEST_REJECT_REASON_TREATMENT_TIME_LESS_THAN_MINIMUM", # Treatment time change is less than minimum treatment time 14: "REQUEST_REJECT_REASON_UF_NOT_IN_PROGESS", # Ultrafiltration is not currently in progress 15: "REQUEST_REJECT_REASON_UF_NOT_PAUSED", # Ultrafiltration is not currently paused 16: "REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS", # A saline bolus is in progress 17: "REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE", # A treatment parameter is out of range 18: "REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION", # The Heparin pre-stop setting is greater than the treatment duration 19: "REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH", # Arterial pressure low and high alarm limits are not inconsistent 20: "REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH", # Venous pressure low and high alarm limits are inconsistent 21: "REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED", # Saline bolus volume maximum has been reached - no more saline allowed 22: "REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS", # A saline bolus is not in progress 23: "REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE", # Requested user action is disabled in current state 24: "REQUEST_REJECT_REASON_ALARM_IS_ACTIVE", # Requested user action not allowed while alarm is active 25: "REQUEST_REJECT_REASON_INVALID_COMMAND", # Requested user action invalid 26: "REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED", # The treatment has been completed 27: "REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED", # Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed 28: "REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET", # Ultrafiltration volume is not set yet 29: "REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM", # The user has not confirmed patient connection 30: "REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE", # Heparin cannot be paused if not currently deliverying Heparin 31: "REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED", # Heparin cannot be resumed if not paused 32: "REQUEST_REJECT_REASON_DG_COMM_LOST", # Treatment cannot initiate if DG comm is lost 33: "REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE", # Post-treatment reservoirs drain not complete 34: "REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE", # Treatment cannot initiate if DG is not in standby idle state 35: "REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT", # Request message not formatted properly 36: "REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME", # Given date/time is invalid 37: "REQUEST_REJECT_REASON____AVAILABLE_1", # Not used - available for use 38: "REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED", # Battery does not have enough charge to start treatment 39: "REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED", # Cannot move on to recirculate without completing full rinseback. 40: "REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY", # Reservoir one fill is not complete 41: "REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED", # Pump track is not ready / closed 42: "REQUEST_REJECT_REASON_DOOR_NOT_CLOSED", # Door is not closed 43: "REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT", # Syringe is not present } NUM_OF_REQUEST_REJECT_REASONS = 43 UNDEFINED_ALARM_ID_MSG = "ALARM_ID_UNDEFINED" ALARM_TITLE = "Alarm" ALARM_ID_NO_ALARM = 0 ALARM_ID_OUT_OF_RANGE = 290 ALARM_PRIORITY_OPTIONS = { 0 : 'ALARM_PRIORITY_NONE' , 1 : 'ALARM_PRIORITY_LOW' , 2 : 'ALARM_PRIORITY_MEDIUM', 3 : 'ALARM_PRIORITY_HIGH', } # alarm colors ALARMS_COLORS_HEADER = { "ALARM_PRIORITY_NONE" : "#438feb", "ALARM_PRIORITY_LOW" : "#db8f00", "ALARM_PRIORITY_MEDIUM" : "#db8f00", "ALARM_PRIORITY_HIGH" : "#831913" } ALARMS_COLORS_BODY = { "ALARM_PRIORITY_NONE" : "#254670", "ALARM_PRIORITY_LOW" : "#f5a623", "ALARM_PRIORITY_MEDIUM" : "#f5a623", "ALARM_PRIORITY_HIGH" : "#c53b33" } ALARM_MUTE_FLAG = 0B0000001000000000 ALARM_UNMUTE_FLAG = 0B0000000000000000 ALARM_BUTTONS_OK = 0B0000000010111000 ALARM_BUTTONS_RESUME = 0B0000000000110000 ALARM_BUTTONS_RESUME_RINSEBACK = 0B0000000000100000 ALARM_BUTTONS_RESUME_END = 0B0000000000010000 ALARM_BUTTONS_RINSEBACK = 0B0000000000101000 ALARM_BUTTONS_RINSEBACK_RESUME = ALARM_BUTTONS_RESUME_RINSEBACK ALARM_BUTTONS_RINSEBACK_END = 0B0000000000001000 ALARM_BUTTONS_END = 0B0000000000011000 ALARM_BUTTONS_END_RESUME = ALARM_BUTTONS_RESUME_END ALARM_BUTTONS_END_RINSEBACK = ALARM_BUTTONS_RINSEBACK_END ALARM_BUTTONS_RESUME_RINSEBACK_END = 0B0000000000000000 ALARM_BUTTONS_RINSEBACK_RESUME_END = ALARM_BUTTONS_RESUME_RINSEBACK_END ALARM_BUTTONS_END_RESUME_RINSEBACK = ALARM_BUTTONS_RESUME_RINSEBACK_END #standby mode GOODMORNING_START_TIME_SEC = 0 GOODEVENING_START_TIME_SEC = 43200 BLOOD_PRIMING_TEXT = "Blood Priming" LIQUID_UNIT = "mL" BLOOD_PRIMING_DEFAULT_VALUE = "0 mL" SALINE_BOLUS_CUMULATIVE = 300 SALINE_UNIT = "mL" UF_MINIMUM_VALUE = 0 UF_MAXIMUM_VALUE = 600 ULTRAFILTRATION_PAUSED_TEXT = "Ultrafiltration Paused" RESUME_TEXT = "RESUME ULTRAFILTRATION" EDIT_TEXT = "EDIT ULTRAFILTRATION VOLUME" TITLE_TEXT = "ULTRAFILTRATION VOLUME (L)" #main treatment pressure PRESSURE_TITLE = "PRESSURES" ARTERIAL_TITLE = "Arterial" VENOUS_TITLE = "Venous" VENOUS_UOM = "mmHg" ARTERIAL_UOM = "mmHg" LOW_TEXT = "LOW" HIGH_TEXT = "HIGH" ACCEPTED = True REJECTED = False #pressure PRESSURE_STEPS = 10 ARTERIAL_PRESSURE_MINIMUM = -400 ARTERIAL_PRESSURE_MAXIMUM = +600 ARTERIAL_PRESSURE_LOW_MIN = -300 ARTERIAL_PRESSURE_LOW_DEF = -300 ARTERIAL_PRESSURE_LOW_MAX = +200 ARTERIAL_PRESSURE_HIGH_MIN = -300 ARTERIAL_PRESSURE_HIGH_DEF = +100 ARTERIAL_PRESSURE_HIGH_MAX = +200 VENOUS_PRESSURE_MINIMUM = -100 VENOUS_PRESSURE_MAXIMUM = +700 VENOUS_PRESSURE_LOW_MIN = -100 VENOUS_PRESSURE_LOW_DEF = -100 VENOUS_PRESSURE_LOW_MAX = +600 VENOUS_PRESSURE_HIGH_MIN = +100 VENOUS_PRESSURE_HIGH_DEF = +400 VENOUS_PRESSURE_HIGH_MAX = +600 #main_treatment_flows BLOOD_FLOW_MINIMUM_VALUE = 100 BLOOD_FLOW_BUFFER = 25 FLOW_SLIDER_WIDTH_BUFFER = 37 BLOOD_FLOW_MAXIMUM_VALUE = 500 DIALYSATE_FLOW_MINIMUM_VALUE = 0 DIALYSATE_FLOW_MAXIMUM_VALUE = 0 # Seems to be bug. need change FLOW_UNIT = "mL/min" BLOOD_FLOW_TEXT = "blood" DIALYSATE_FLOW_TEXT = "dialysate" #main treatment screen VITALS_TITLE = "VITALS" OUT_OF_RANGE_COLOR = "#c53b33" IN_RANGE_COLOR = "#fcfcfc" SYSTOLIC_LOWER_LIMIT = 60 SYSTOLIC_UPPER_LIMIT = 250 DIASTOLIC_LOWER_LIMIT = 40 DIASTOLIC_UPPER_LIMIT = 200 HEART_RATE_LOWER_LIMIT = 40 HEART_RATE_UPPER_LIMIT = 180 HEART_RATE_TITLE = "Heart Rate" BLOOD_PRESSURE_TITLE = "Blood Pressure" BLOOD_PRESSURE_UNIT = "mmHg" HEART_RATE_UNIT = "BPM" BLOOD_PRIMING_RANGE = 300 BLOOD_PRIMING_TARGET_MAXIMUM = 300 #tst_treatment_monitoring FLOWS_TEXT = "FLOWS" BLOOD_UNIT = "mL/min" DIALYSATE_TEXT = "Dialysate" BLOOD_TEXT = "Blood" VITALS_TEXT = "VITALS" BLOOD_PRESSURE_TEXT = "mmHg" HEARTRATE_UNIT = "BPM" PRESSURE_TEXT = "PRESSURE (mmHg)" ARTEREAL_TEXT = "Arterial" VENOUS_TEXT = "Venous" TIME_DURATION_TEXT = "Time Remaining" ULTRAFILTERATION_TEXT = "ULTRAFILTRATION VOLUME (L)" SALINE_BOLUS = "SALINE BOLUS" VOLUME_DELIVERED = "Volume Delivered" CUMULATIVE_DELIVERED = "Cumulative Delivered" HEPARIN_TEXT = "HEPARIN" VOLUME_DELIVERED = "Volume Delivered" #patient id CHARACTER_PATIENT_ID = ["qwerty","sampleid","abcdefghijklmnop","patientid", "username"] ALPHANUMERIC_PATIENT_ID = ["sA@MpLE#123", "A@BH&321","5432@qwerty"] KEYBOARD_SWITCH = ["ABC", "&123"] #main-treatment heparin HEPARIN_UNIT = "mL" HEPARIN_DELIVERY_TEXT = "HEPARIN DELIVERY" HEPARIN_DELIVERY_OFF_TEXT = "OFF" HEPARIN_STOP_TEXT = "Delivery Stopped" HEPARIN_RESUME_DELIVERY_TEXT = "RESUME DELIVERY" HEPARIN_BOLUS_ACTIVE_TEXT = "Bolus Active" HEPARIN_PAUSE_DELIVERY_TEXT = "PAUSE DELIVERY" HEPARIN_MAXIMUM_VOLUME_DELIVERED_TEXT = "Maximum Cumulative Heparin Volume Delivered" HEPARIN_SYRINGE_EMPTY_TEXT = "Syringe Empty" #Time_Duration CREATE_TREATMENT_PARAMETERS = ["Blood Flow Rate", "Dialysate Flow Rate", "Duration","Heparin Dispensing Rate", "Heparin Bolus Volume","Heparin Stop Time", "Saline Bolus","Dialysate Temperature","Blood Pressure Measurement Interval", "Rinseback Flow Rate"] TREATMENT_PAUSED_TEXT = "Treatment Paused" #ultrafilteration volume based on flow parameters. Python list contains Rotational speed, Motor speed, # MC speed, MC current and PWM. TREATMENT_ULTRAFILTRATION_FLOW_PARAMETERS = { 0 : [100, 1, 1, 1, 1, 1, 1], 1 : [550, 24, 32, 425, 85, 18, 36], 2 : [80, 125, 187, 257, 530, 458, 985], 3 : [100, 0, 0, 0, 0, 0, 0], 4 : [220, 1.45, 1.45, 1.45, 1.45, 1.45, 1.45], } #dictionary contains uf maximum and minimum value's to set. TREATMENT_ULTRAFILTRATION_TESTING_OPTION = { 0 : {"uf_maximum" : 600, "uf_minimum" : 0}, 1 : {"uf_maximum" : 500, "uf_minimum" : 0}, 2 : {"uf_maximum" : 550, "uf_minimum" : 0}, 3 : {"uf_maximum" : 300, "uf_minimum" : 0}, 4 : {"uf_maximum" : 280, "uf_minimum" : 0}, 5 : {"uf_maximum" : 765, "uf_minimum" : 500}, 6 : {"uf_maximum" : 680, "uf_minimum" : 450}, 7 : {"uf_maximum" : 480, "uf_minimum" : 380}, 8 : {"uf_maximum" : 390, "uf_minimum" : 675}, 9 : {"uf_maximum" : 290, "uf_minimum" : 125}, }