[Sample^Water Sample] Place cup in the water sampling pocket. Press and hold the "Water Sample" button. = 8_water sampling_v4.png [Sample^Water Sample Result] Test the water sample per your clinic's instructions and enter the result. = 44_water test pass fail-01.png [Sample^Water Sample Result Failed] Water sample result failed. = 44_water test fail B-01.png [Consumables^Consumables Installation] Remove the concentrate and dialysate caps. = 48_remove caps alternative-01.png Connect the acid concentrate to the acid port. = 13_install acid line_v4.png Connect the bicarbonate concentrate to the bicarbonate port. = 14_install bicarb line_v4.png [Disposables^Cartridge Installation] Open the front panel door. = 1_HD door open-01.png Unlock the pump track by moving the lever to its upward position. = 7_pump track open-01.png Install the cartridge using the alignment pins. = 3_insert casette-01.png Insert tubing into blood and dialysate pumps. = 4_loop casette tubes-01.png Lock the pump track by moving the lever to its downward position. = 6_Pump track lock-01.png [Disposables^Cartridge Connection] Connect the cartridge blood lines to the dialyzer. = 25_filter connection 1A+1B-01.png Connect the cartridge dialysis fluid lines to the dialyzer. = 26_fiilter connection 2A + 2B-01.png Insert dialyzer into the clamps. = 24_load filter-01.png Connect the arterial pressure line to the arterial pressure transducer port. = 27_PBo connection Arterial-01.png Connect the venous pressure line to the venous pressure transducer port. = 28_PBo connection venous-01.png Connect the cartridge dialysis fluid lines to the DG fluid ports. = 20_dialysate lines to DG_v4.png [Disposables^Heparin Syringe] Fill a syringe with heparin and connect the cartridge heparin tubing line. = 30_fill syringe with heparin_v4.png Insert heparin filled syringe into the infusion pump housing. = 31_load syringe-01.png [Disposables^Saline Bag] Hang the saline bag on the left side hook. Spike a saline bag and connect it to the cartridge saline line. = 34_saline connect-01.png Pinch saline y-connector to the closed position. = 35_clamping Y connecter-01.png Close the front panel door. = 2_HD door closed-01.png [Connection^Patient Connection] Draw a dialysate sample from the needless valve port. = 21_take sample with syringe_v4.png Wash your hands and establish vascular access per your clinic's instructions. = 45_wash hands-01.png Pinch arterial clamp and venous clamp on located on the cartridge patient lines. = 23_pinch Arteriaal and Venous tubes-01.png Remove arterial and venous line connector. = 39_remove shunt_v4.png Connect arterial and venous cartridge lines to your patient access lines. = 36_connect Arterial Venous to cartridge-01.png [Connection^Start Treatment] Unpinch arterial clamp and venous clamp located on the cartridge patient lines. = 37_unpinch Arterial Venous to patient-01.png [^Rinseback Setup] Pinch arterial line and disconnect patient access line. = 38_disconnect Arterial patient access-01.png Connect arterial line to the saline Y-connector and unpinch clamp. = 40_connect Arterial line-01.png Unpinch clamps at the arterial line and saline bag line. = 42_unclamp Arterial saline Line-01.png [^Rinseback Complete] Pinch arterial and venous line after rinseback is complete. = 41_clamp Arterial saline Line-01.png [Disconnection^Patient Disconnection] Pinch arterial clamp and venous clamp on located on the cartridge patient lines and access lines. = 37_unpinch Arterial Venous to patient-01.png Disconnect arterial and venous cartridge lines from your patient access lines. = 38_disconnect Arterial patient access-01.png [Disposables^Disposables Removal] Disconnect the arterial and venous pressure lines. = 29_PBo connection remove-01.png Remove heparin syringe from the infusion pump housing. = 33_remove syringe-01.png Pinch dialysate lines and disconnect tubing lines from the system. = 22_disconnect dialysate from cassette_v4.png Install dialysis fluid cap. = 15_replace dialysate line cap_v4.png Disconnect acid and bicarbonate concentrates tubing lines from the system.= 16_remove acid and bicarb connect_v4.png Install concentrate fluid cap. = 19_replace concentrate cap-01.png Unlock the pump track by moving the lever to its upward position. = 7_pump track open-01.png Remove cartridge and dialyzer from the HD device. = 5_remove casette-01.png [^Recirculate] Recirculate 0 =logo.png Recirculate 1 =logo.png Recirculate 2 =logo.png [Disinfection^Disinfection] Disinfection1=logo.png Disinfection2=logo.png Disinfection3=logo.png [Chemical Disinfect^Chemical Disinfect] Remove the concentrate fluid cap and connect the chemical disinfectant = 17_connect PAA_v4.png Disconnect the chemical disinfectant and replace concentrate cap. = 19_replace concentrate cap-01.png Test the system for residual chemicals using a test strip. = 43_test residual sample-01.png