 * Copyright (c) 2021-2024 Diality Inc. - All Rights Reserved.
 * \copyright
 * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN
 * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER.
 *
 * \file    DiagnosticsDialog.qml
 * \author  (last)      Dara Navaei
 * \date    (last)      05-Mar-2024
 * \author  (original)  Behrouz NematiPour
 * \date    (original)  11-May-2021
 *
 */

// Qt
import QtQuick 2.12
// Project
import Gui.Actions      0.1

//  Qml imports
import "qrc:/globals"
import "qrc:/components"

/*!
 * \brief   the post treatment prime stack screen
 */
DiagnosticsBase { id: _root
    objectName  : "_DiagnosticsFP"

    contentItem : Item { id: _content

        DebugDataColumn { id: _FPPressureColumn
            textObjectName  :"_FPPressureData"
            title           : qsTr(" Pressure ")
            anchors {
                top     : parent.top
                left    : parent.left
            }

            model: [
                vFPPressures.beforePresureRegulator      .toFixed(2) ,
                vFPPressures.afterPressureRegulator      .toFixed(2) ,
                vFPPressures.beforeInletConductivity     .toFixed(2) ,
                vFPPressures.beforeROFilter              .toFixed(2) ,
                vFPPressures.afterROFilter               .toFixed(2) ,
                vFPPressures.beforeROPump                .toFixed(2) ,
                vFPPressures.ROConcentrate               .toFixed(2) ,
                vFPPressures.ROConcentrateDrop           .toFixed(2) ,
                vFPPressures.drainDrop                   .toFixed(2) ,
            ]
            label: [
                "M1 bRegPSI         ",
                "M3 aRegPSI         ",
                "P8 bInCond         ",
                "P13 bROFilter      ",
                "P17 aROFilter      ",
                "X1 bROPump         ",
                "X2 ROConc          ",
                "X3 dROConc         ",
                "X4 dDrain          ",
            ]
        }

        DebugDataColumn { id: _FPROPumpColumn
            textObjectName  :"_FPROPumpData"
            title           : qsTr(" RO Pump ")
            anchors {
                top         : parent.top
                left        : _FPPressureColumn.right
                leftMargin  : spacing
            }
            model: [
                vFPROPump.pumpState                         ,
                vFPROPump.pumpDutyCycle                     ,
                vFPROPump.pumpFBDutyCycle                   ,
                vFPROPump.pumpSpeed             .toFixed(2) ,
                vFPROPump.targetPressure        .toFixed(2) ,
                vFPROPump.targetFlow            .toFixed(2) ,
                vFPROPump.targetDutyCycle       .toFixed(2) ,
                vFPROPump.pumpDutyCyclePct      .toFixed(2) ,
                vFPROPump.pumpFBDutyCyclePct    .toFixed(2) ,
            ]
            label: [
                "P12 State      ",
                "P12 DC         ",
                "P12 FBDC       ",
                "P12 Spd        ",
                "P12 tPSI       ",
                "P12 tFlow      ",
                "P12 tDC        ",
                "P12 DCPct      ",
                "P12 FBDCPct    ",
            ]
        }

        DebugDataColumn { id: _FPBoostPumpColumn
            textObjectName  :"_FPBoostPumpData"
            title           : qsTr(" Boost Pump ")
            anchors {
                top         : parent.top
                left        : _FPROPumpColumn.right
                leftMargin  : spacing
            }
            model: [
                vFPBoostPump.pumpState                         ,
                vFPBoostPump.pumpDutyCycle                     ,
                vFPBoostPump.pumpFBDutyCycle                   ,
                vFPBoostPump.pumpSpeed             .toFixed(2) ,
                vFPBoostPump.targetPressure        .toFixed(2) ,
                vFPBoostPump.targetFlow            .toFixed(2) ,
                vFPBoostPump.targetDutyCycle       .toFixed(2) ,
                vFPBoostPump.pumpDutyCyclePct      .toFixed(2) ,
                vFPBoostPump.pumpFBDutyCyclePct    .toFixed(2) ,
            ]
            label: [
                "P40 State      ",
                "P40 DC         ",
                "P40 FBDC       ",
                "P40 Spd        ",
                "P40 tPSI       ",
                "P40 tFlow      ",
                "P40 tDC        ",
                "P40 DCPct      ",
                "P40 FBDCPct    ",
            ]
        }

        DebugDataColumn { id: _FPTemperatureColumn
            textObjectName  :"_FPTemperatureData"
            title           : qsTr(" Temperature ")
            anchors {
                top         : parent.top
                left        : _FPBoostPumpColumn.right
                leftMargin  : spacing
            }
            model: [
                vFPTemperature.inletConductivityTemp        .toFixed(2) ,
                vFPTemperature.outletConductivityTemp       .toFixed(2) ,
                vFPTemperature.beforePressureRegulatorTemp  .toFixed(2) ,
                vFPTemperature.afterPressureRegulatorTemp   .toFixed(2) ,
                vFPTemperature.beforeInletConductivityTemp  .toFixed(2) ,
                vFPTemperature.beforeROFilterTemp           .toFixed(2) ,
                vFPTemperature.afterROFilterTemp            .toFixed(2) ,
                vFPTemperature.beforeROPumpTemp             .toFixed(2) ,
                vFPTemperature.ROConcentrateTemp            .toFixed(2) ,
                vFPTemperature.ROConcentratePumpTemp        .toFixed(2) ,
                vFPTemperature.drainDropTemp                .toFixed(2) ,
                vFPTemperature.ROInletTemp                  .toFixed(2) ,
                vFPTemperature.ROOutletTemp                 .toFixed(2) ,
            ]
            label: [
                "P10 inCond     ",
                "P19 outCond    ",
                "M1 bReg        ",
                "M3 aReg        ",
                "P8 bInCond     ",
                "P13 bRO        ",
                "P17 aRO        ",
                "X1 bROPump     ",
                "X2 ROConc      ",
                "X3 ROConcPump  ",
                "X4 Drain       ",
                "P7 ROIn        ",
                "P16 ROOut      ",
            ]
        }

        DebugDataColumn { id: _FPFlowColumn
            textObjectName  :"_FPFlowData"
            title           : qsTr(" Flow ")
            anchors {
                top         : parent.top
                left        : _FPTemperatureColumn.right
                leftMargin  : spacing
            }
            model: [
                vFPFlow.waterInletFlow       .toFixed(2) ,
                vFPFlow.waterInletTemp       .toFixed(2) ,
                vFPFlow.rOFilterOutletFlow   .toFixed(2) ,
                vFPFlow.rOFilterOutletTemp   .toFixed(2) ,
            ]
            label: [
                "P7 FlowIn     ",
                "P7 TempIn     ",
                "P16 FlowOut   ",
                "P16 TempOut   ",
            ]
        }

        DebugDataColumn { id: _FPLevelColumn
            textObjectName  :"_FPLevelData"
            title           : qsTr(" Level ")
            anchors {
                top         : parent.top
                left        : _FPFlowColumn.right
                leftMargin  : spacing
            }
            model: [
                vFPLevel.P25FloaterLevel                ,
            ]
            label: [
                "P25 Floater    ",
            ]
        }

        DebugDataColumn { id: _FPConductivityColumn
            textObjectName  :"_FPConductivityData"
            title           : qsTr(" Conductivity ")
            anchors {
                top         : _FPPressureColumn.bottom
                topMargin   : spacing
                left        : _FPPressureColumn.left
            }
            model: [
                vFPConductivity.P9Conductivity           .toFixed(2) ,
                vFPConductivity.P18Conductivity          .toFixed(2) ,
            ]
            label: [
                "P9     ",
                "P18    ",
            ]
        }

        // TODO: The TouchRect should be unnecessary since the first communication message with UI/TD is the version.
        TouchRect {
            width       : _FPVersionsColumn.width
            height      : _FPVersionsColumn.height
            onClicked   : vAdjustmentVersions.doAdjustment()
            radius      : 5
            anchors {
                bottom          : parent.bottom
                right           : parent.right
            }

            DebugDataColumn { id: _FPVersionsColumn
                textObjectName  :"_FPVersionsData"
                title           : ""
                horizontalAlignmentText : Text.AlignLeft
                fontPixelSizeText       : Fonts.fontPixelDebugTitle
                isTouchRect             : true
                model: [ "FP: v%1.%2.%3-%4 v%5.%6.%7-%8 c%9"
                    .arg(vAdjustmentVersions.fpVerMajor             )
                    .arg(vAdjustmentVersions.fpVerMinor             )
                    .arg(vAdjustmentVersions.fpVerMicro             )
                    .arg(vAdjustmentVersions.fpVerBuild             )
                    .arg(vAdjustmentVersions.fpVerFPGAMajor         )
                    .arg(vAdjustmentVersions.fpVerFPGAMinor         )
                    .arg(vAdjustmentVersions.fpVerFPGALab           )
                    .arg(vAdjustmentVersions.fpVerFPGAId            )
                    .arg(vAdjustmentVersions.fpVerCompatibilityRev  )
                ]
            }
        }
    }

    Connections { target: _GuiView
        function onDidActionReceive( vAction, vData ) {
            // DEBUG: console.debug("onDidActionReceive", vAction, vData)
            if (vAction === GuiActions.ID_CANBusFaultCount ) {
                _canbusFaultCountText.count = vData[0]
            }
        }
    }
}