# ###################################################################################################### # Do not use data message with change interval in here, it affects the instructions update performance. # # ###################################################################################################### # multiple value reserved blocks can be used even in each line. # format is as the following (look at the Messages_List.xlsx for the id and parameters): # {:::} # extra string can be used for unit(mL) which also accepts space # In case extra string or precision is not being used leave it empty eg. {77:1::} # the format shall always have three ':' and message id and parameter number shall not be ignored. # otherwise will NOT be identified as a value reserved block and will be used as part of the string. # Entry format: # [^] # "Title" = # <Instruction step> = <image.png> # ###################################################################################################### [Concentrates] Title = Connect Acid and Bicarbonate Concentrates Remove acid connector and connect to acid concentrate. = Concentrates_1.png Connect dry bicarbonate. = Concentrates_2.png [Installation^Blood Tubing Set] Title = Install Blood Tubing Set Open the blood pump door. = Installation_BloodTube_1.png Insert blood tubing set and ensure it is secure. = Installation_BloodTube_2.png Push the blood tube into the blood pump. = Installation_BloodTube_3.png Close the blood pump door. = Installation_BloodTube_4.png [Installation^Bloodlines] Title = Install Bloodlines Insert saline line into the first slot. = Installation_Bloodlines_1.png Insert arterial line into the second slot. = Installation_Bloodlines_2.png Ensure the venous line is placed in the bubble detector. = Installation_Bloodlines_3.png Insert the venous line into the third slot. = Installation_Bloodlines_4.png Connect the arterial and venous bloodlines using the recirculation connector. = Installation_Bloodlines_5.png [Installation^Pressure Lines and Dialyzer] Title = Install Pressure Lines and Dialyzer Connect the arterial pressure line to the arterial pressure transducer port. = Installation_CPLD_1.png Connect the venous pressure line to the venous pressure transducer port. = Installation_CPLD_2.png Insert dialyzer into the holder and connect the dialysate lines. = Installation_CPLD_3.png Connect the bloodlines to the dialyzer. = Installation_CPLD_4.png Clamp the venous chamber line. = Installation_CPLD_5.png Clamp the heparin line. = Installation_CPLD_6.png [@Installation] Title = Install Concentrates and Blood Tubing Set Install acid and bicarbonate concentrates. = Install_Advanced_1.png Install blood tubing set and dialyzer. = Install_Advanced_2.png [Saline] Title = Connect Saline Bag Hang saline bag on the hook. = Saline_1.png Clamp saline line. = Saline_2.png Use the saline line to spike saline bag. = Saline_3.png Unclamp saline line. = Saline_4.png [@Saline] Title = Connect Saline Bag Spike and connect saline bag. = Saline_Advanced_1.png [Connect] Title = Connect Bloodlines to the Patient Clamp arterial and venous bloodlines (2 clamps). = Connect_1.png Remove recirculation connector from the bloodlines. = Connect_2.png Connect bloodlines to patient access lines. = Connect_3.png Unclamp arterial and venous bloodlines (2 clamps). = Connect_4.png [@Connect] Title = Connect Bloodlines to the Patient Connect bloodlines to patient access lines. = Connect_Advanced_1.png [Disconnection] Title = Remove Concentrates and Blood Tubing Set Remove blood tubing set and dialyzer. = Install_Advanced_2.png Remove acid and bicarbonate concentrates. = Install_Advanced_1.png