Index: AlarmMapping.csv =================================================================== diff -u -r0f1aa395dfb46e006bdec10d0bb99f2ed27739bf -r7e503c5459ec77a2816d6c7789da9b206cedbe8a --- AlarmMapping.csv (.../AlarmMapping.csv) (revision 0f1aa395dfb46e006bdec10d0bb99f2ed27739bf) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision 7e503c5459ec77a2816d6c7789da9b206cedbe8a) @@ -88,19 +88,19 @@ 87,"DG heating invalid calibration record." 88,"DG concentrate pumps hall sensor out of range." 89,"HD BP occlusion sensor error." - 90,"This alarm ID is available for use." + 90,"DG load cells FPGA read error." 91,"HD No dialysate flow data receive in the last 3 seconds." 92,"DG conductivity sensor bad status." 93,"DG outlet primary conductivity out of range." - 94,"This alarm ID is available for use." - 95,"This alarm ID is available for use." + 94,"DG pressure out of range." + 95,"DG watchdog expired." 96,"Inlet water temperature in high range." 97,"Fill conductivity out of range." 98,"HD battery communication fault." 99,"HD syringe pump stall alarm." 100,"HD no cartridge self-test timeout." 101,"HD dry self-test timeout." - 102,"Real-time clock communication error." + 102,"DG heat disinfect temperature gradient out of range." 103,"HD non-volatile calibration group invalid record CRC." 104,"Air trap level sensors reporting illegal combination of air/fluid." 105,"DG non-volatile system group invalid record CRC." @@ -115,10 +115,10 @@ 114,"HD venous air bubble detector self-test failure." 115,"DG temperature sensor out of range." 116,"DG temperature sensor ADC out of range." - 117,"DG primary heater internal temperature out of range." - 118,"DG primary heater cold junction temperature out of range." - 119,"DG trimmer heater internal temperature out of range." - 120,"DG trimmer heater cold junction temperature out of range." + 117,"DG CAN message not acked." + 118,"DG RTC config error." + 119,"DG RTC battery low error." + 120,"HD pre-treatment mode wet self-test prime check failure." 121,"DG main primary heater voltage out of range." 122,"DG small primary heater voltage out of range." 123,"DG trimmer heater voltage out of range." @@ -144,10 +144,10 @@ 143,"DG dialysate temperature sensors out of range." 144,"DG software configuration record invalid CRC." 145,"Concentrate conductivity after adding acid out of range alarm." - 146,"Dialysate conductivity out of range." + 146,"DG RTC or timer accuracy failure." 147,"Wait for the DG to produce dialysate." 148,"Inlet water temperature too high." - 149,"Alarm ID available for use." + 149,"HD watchdog expired." 150,"Inlet water conductivity in high range." 151,"Inlet water conductivity in low range." 152,"Inlet water pressure in low range." @@ -159,8 +159,8 @@ 158,"Inlet water temperature is in the low range." 159,"Dialysate inlet pump failed flow vs motor speed check." 160,"Blood pump rotor speed too high." - 161,"This alarm ID is available for use." - 162,"This alarm ID is available for use." + 161,"DG comm too many bad CRCs." + 162,"DG FPGA clock speed check failure." 163,"HD sees primary load cell for reservoir 1 change too much too fast." 164,"HD sees primary load cell for reservoir 2 change too much too fast." 165,"HD in treatment rinseback operation timeout." @@ -199,8 +199,8 @@ 198,"DG heaters cold junction temperature out of range." 199,"DG heaters fault." 200,"DG thermistors/sensors temperature out of range." - 201,"This alarm ID is available for use." - 202,"Inlet water pressure fault." + 201,"HD pre-treatment mode wet self-test lc vs FMD failure." + 202,"HD pre-treatment mode dry pressure normal self-test failure." 203,"Pressure sensor fault." 204,"RO rejection ratio out of range." 205,"Conductivity sensor fault." @@ -229,8 +229,8 @@ 228,"HD time out on prime sub-mode purge air state." 229,"HD prime dialysate dialyzer time out alarm." 230,"HD prime dialysate bypass time out alarm." - 231,"HD pre-treatment mode dry self-tests failure." - 232,"HD pre-treatment mode wet self-tests failure." + 231,"HD pre-treatment mode dry pressure self-test failure." + 232,"HD pre-treatment mode wet self-test LC vs LC failure." 233,"RTC battery low." 234,"RTC (i.e read time) or RAM operations failure (read or write)." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." @@ -288,4 +288,5 @@ 287,"HD processor clock speed checks against FPGA clock failure." 288,"DG trimmer heater on with flow timeout." 289,"DG dialysate or concentrate caps not closed." - 290,"Total number of alarms." + 290,"DG flow too low while heater is on." + 291,"Total number of alarms."