Index: AlarmMapping.csv =================================================================== diff -u -r200398eaf784dd2965023151086ba1939d2eb746 -rc4b95505c1d02a74d9c1b8132578bbd8a21cec9a --- AlarmMapping.csv (.../AlarmMapping.csv) (revision 200398eaf784dd2965023151086ba1939d2eb746) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision c4b95505c1d02a74d9c1b8132578bbd8a21cec9a) @@ -5,28 +5,28 @@ 4,"HD Watchdog POST failure." 5,"DG Watchdog POST failure." 6,"UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." - 7,"Real-time clock configuration error." + 7,"HD RTC battery low." 8,"HD accelerometer failed POST." 9,"DG accelerometer failed POST." - 10,"RTC or MCU timer inaccurate." - 11,"DG heaters failed POST." + 10,"Not used." + 11,"HD dialysate temperature below target temperature." 12,"HD firmware image integrity POST test failed." 13,"DG firmware image integrity POST test failed." - 14,"HD blood flow invalid calibration." - 15,"HD dialysate flow invalid calibration." + 14,"DG invalid usage record CRC." + 15,"HD invalid usage record CRC." 16,"HD alarm audio failed POST." 17,"HD UI POST failed." 18,"DG load cells invalid calibration record." - 19,"DG flow sensors invalid calibration record." + 19,"HD dialysate temperature above target temperature." 20,"DG conductivity sensors invalid calibration record." 21,"DG drain line volume invalid calibration record." 22,"DG reservoirs invalid calibration record." 23,"DG acid concentrate calibration record." 24,"DG bicarb concentrate calibration record." 25,"DG accelerometer invalid calibration record." 26,"HD accelerometer invalid calibration record." - 27,"HD blood flow invalid calibration record." - 28,"HD dialyzer flow invalid calibration record." + 27,"Not used." + 28,"Not used." 29,"HD heparin force sensor invalid calibration record." 30,"HD Software fault.\nSoftware found itself in an unexpected state." 31,"Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." @@ -41,9 +41,9 @@ 40,"Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." 41,"Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." 42,"Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." - 43,"Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time." + 43,"HD blood leak self test fault." 44,"User interface communication timeout." - 45,"Too many bad CRCs detected on received system messages." + 45,"HD too many bad communications CRC." 46,"System message that required acknowledgment was not acknowledged." 47,"Ultrafiltration rate is too high error during treatment." 48,"Ultrafiltration volume accuracy error during treatment." @@ -70,9 +70,9 @@ 69,"HD blood leak sensor invalid calibration record." 70,"HD arterial pressure self-test failure alarm." 71,"HD venous pressure self-test failure alarm." - 72,"HD blood flow meter status check self-test failure alarm." - 73,"HD dialysate flow meter status check self-test failure alarm." - 74,"HD blood leak detector self-test failure alarm." + 72,"Not used." + 73,"Not used." + 74,"HD blood leak detector self-test transmit timeout." 75,"HD syringe pump self-test failure alarm." 76,"HD monitored voltage is out of range." 77,"DG monitored voltage is out of range." @@ -83,46 +83,46 @@ 82,"HD syringe pump DAC write failure." 83,"HD syringe pump is running while the BP is off." 84,"HD venous pressure sensor not being read." - 85,"HD venous pressure sensor temperature out of range error." + 85,"HD pump track latch opened alarm." 86,"HD BP occlusion sensor not being read." 87,"DG heating invalid calibration record." 88,"DG concentrate pumps hall sensor out of range." 89,"HD BP occlusion sensor error." - 90,"This alarm ID is available for use." + 90,"DG load cells FPGA read error." 91,"HD No dialysate flow data receive in the last 3 seconds." - 92,"This alarm ID is available for use." - 93,"This alarm ID is available for use." - 94,"This alarm ID is available for use." - 95,"This alarm ID is available for use." - 96,"This alarm ID is available for use." - 97,"This alarm ID is available for use." + 92,"DG conductivity sensor bad status." + 93,"DG outlet primary conductivity out of range." + 94,"DG pressure out of range." + 95,"DG watchdog expired." + 96,"Inlet water temperature in high range." + 97,"Fill conductivity out of range." 98,"HD battery communication fault." 99,"HD syringe pump stall alarm." 100,"HD no cartridge self-test timeout." 101,"HD dry self-test timeout." - 102,"Real-time clock communication error." - 103,"HD non-volatile calibration group invalid record CRC." + 102,"DG heat disinfect temperature gradient out of range." + 103,"HD invalid calibration CRC." 104,"Air trap level sensors reporting illegal combination of air/fluid." - 105,"DG non-volatile system group invalid record CRC." - 106,"This alarm ID is available for use." + 105,"DG invalid calibration CRC." + 106,"DG dialysate flow sensor invalid calibration record." 107,"HD reports DG restarted fault." 108,"HD syringe pump ADC error." 109,"HD syringe pump volume check error." 110,"HD syringe pump speed check error." 111,"HD syringe pump not stopped in off state error." - 112,"HD blood leak detector fault." - 113,"HD arterial air bubble detector self-test failure." + 112,"HD blood leak zero command transmit timeout." + 113,"HD blood leak zero command fault." 114,"HD venous air bubble detector self-test failure." 115,"DG temperature sensor out of range." - 116,"DG temperature sensor ADC out of range." - 117,"DG primary heater internal temperature out of range." - 118,"DG primary heater cold junction temperature out of range." - 119,"DG trimmer heater internal temperature out of range." - 120,"DG trimmer heater cold junction temperature out of range." + 116,"DG temperature sensor ADC fault." + 117,"DG CAN message not acked." + 118,"DG RTC config error." + 119,"DG RTC battery low error." + 120,"HD pre-treatment mode wet self-test prime check failure." 121,"DG main primary heater voltage out of range." 122,"DG small primary heater voltage out of range." 123,"DG trimmer heater voltage out of range." - 124,"HD end of treatment alarm (high priority - user still not acting to end treatment)." + 124,"HD end of treatment alarm (high priority)." 125,"Blood sitting too long after treatment stopped by user alarm (>5 min)." 126,"HD blood leak detected alarm." 127,"Venous pressure too low during treatment." @@ -141,26 +141,26 @@ 140,"Dialysate generator communication timeout." 141,"Air trap fill timeout during treatment." 142,"Blood pump occlusion detected." - 143,"DG dialysate temperature sensors drift timeout." - 144,"DG software configuration record invalid CRC." + 143,"DG dialysate temperature sensors out of range." + 144,"DG RO flow sensor invalid calibration record." 145,"Concentrate conductivity after adding acid out of range alarm." - 146,"Dialysate conductivity out of range." - 147,"DG dialysate generation conductivity fault alarm." + 146,"DG RTC or timer accuracy failure." + 147,"Wait for the DG to produce dialysate." 148,"Inlet water temperature too high." - 149,"Inlet water temperature too low." - 150,"Inlet water conductivity too high." - 151,"Inlet water conductivity too low." - 152,"Inlet water pressure too low." + 149,"HD watchdog expired." + 150,"Inlet water conductivity in high range." + 151,"Inlet water conductivity in low range." + 152,"Inlet water pressure in low range." 153,"HD prime completed high priority alarm." 154,"EEPROM operations (read, write, erase) failure." - 155,"DG software configuration record invalid CRC." - 156,"HW usage data (treatment time in HD and total consumed water in DG) failure." - 157,"This alarm ID is available for use." - 158,"This alarm ID is available for use." + 155,"Not used." + 156,"Not used." + 157,"DG chemical disinfect prime acid line timeout." + 158,"Inlet water temperature is in the low range." 159,"Dialysate inlet pump failed flow vs motor speed check." 160,"Blood pump rotor speed too high." - 161,"Blood flow sensor signal strength too low." - 162,"Dialysate flow sensor signal strength too low." + 161,"DG comm too many bad CRCs." + 162,"DG FPGA clock speed check failure." 163,"HD sees primary load cell for reservoir 1 change too much too fast." 164,"HD sees primary load cell for reservoir 2 change too much too fast." 165,"HD in treatment rinseback operation timeout." @@ -171,10 +171,10 @@ 170,"HD syringe empty alarm." 171,"HD syringe pump occlusion alarm." 172,"HD syringe pump not enough Heparin alarm." - 173,"HD arterial air bubble detected alarm." - 174,"HD arterial air bubble detected rinseback alarm." + 173,"HD RTC configuration error." + 174,"HD RTC or timer accuracy failure." 175,"HD pump direction status error." - 176,"HD active reservoir is full during treatment and DG not ready to switch reservoirs." + 176,"HD dialysate temperature out of high safety range." 177,"DG software fault.\nSoftware found itself in an unexpected state." 178,"HD communication timeout." 179,"DG FPGA communication down for too long." @@ -191,22 +191,22 @@ 190,"DG drain pump off fault." 191,"DG flow rate out of upper range." 192,"DG flow rate out of lower range." - 193,"RO pump flow rate out of range." + 193,"HD dialysate temperature out of low safety range." 194,"DG RO pump duty cycle out of range." 195,"DG RO pump pressure out of range." - 196,"DG temperature sensor error flag fault." - 197,"DG temperature sensors ADC fault." - 198,"DG heaters cold junction temperature out of range." - 199,"DG heaters fault." + 196,"DG temperature sensor error bit fault." + 197,"DG temperature sensors FPGA fault." + 198,"RO flow too low while primary heater is on." + 199,"Dialysate flow too low while trimmer heater is on." 200,"DG thermistors/sensors temperature out of range." - 201,"Inlet water quality is bad (temperature, conductivity, pressure)." - 202,"Inlet water pressure fault." + 201,"HD pre-treatment mode wet self-test lc vs FMD failure." + 202,"HD pre-treatment mode dry pressure normal self-test failure." 203,"Pressure sensor fault." 204,"RO rejection ratio out of range." 205,"Conductivity sensor fault." 206,"DG dialysate fill runs out of time." 207,"DG flow meter check failure alarm." - 208,"DG primary heater on with no flow time out." + 208,"HD venous pressure occlusion alarm." 209,"DG drain circulation line timeout." 210,"HD battery pack detected an error." 211,"Blood sitting too long warning (>4 min)." @@ -222,16 +222,16 @@ 221,"HD Saline bag is empty." 222,"HD dialysate temperature too high alarm." 223,"HD dialysate temperature too low alarm." - 224,"Treatment stopped by user action - pressed stop button." + 224,"Treatment stopped by user action." 225,"HD end of treatment warning." 226,"HD prime completed low priority alarm." 227,"HD prime out of time alarm." 228,"HD time out on prime sub-mode purge air state." 229,"HD prime dialysate dialyzer time out alarm." 230,"HD prime dialysate bypass time out alarm." - 231,"HD pre-treatment mode dry self-tests failure." - 232,"HD pre-treatment mode wet self-tests failure." - 233,"RTC battery low." + 231,"HD pre-treatment mode dry pressure self-test failure." + 232,"HD pre-treatment mode wet self-test LC vs LC failure." + 233,"DG barometric sensor coefficients bad CRC." 234,"RTC (i.e read time) or RAM operations failure (read or write)." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." 236,"HD needs new cartridge to be installed." @@ -286,5 +286,11 @@ 285,"HD treatment recirculate timeout warning." 286,"HD treatment rinseback complete timeout warning." 287,"HD processor clock speed checks against FPGA clock failure." - 288,"DG trimmer heater on with flow timeout." - 289,"Total number of alarms." + 288,"HD load cells primary/back up drift out of range." + 289,"DG dialysate or concentrate caps not closed." + 290,"DG flow too low while heater is on." + 291,"HD processor is in Disinfect Flush mode." + 292,"HD processor is in Disinfect Heat mode." + 293,"HD processor is in Disinfect Chemical mode." + 294,"HD processor Disinfect Chemical mode instructions to user." + 295,"Total number of alarms."