Index: AlarmMapping.csv =================================================================== diff -u -r67d05211b87d310ce213695c52b110fb28cfbd4b -r9ae3b0d6624904693329309aaf8ff02784c17184 --- AlarmMapping.csv (.../AlarmMapping.csv) (revision 67d05211b87d310ce213695c52b110fb28cfbd4b) +++ AlarmMapping.csv (.../AlarmMapping.csv) (revision 9ae3b0d6624904693329309aaf8ff02784c17184) @@ -64,10 +64,10 @@ 63,"FPGA reports failure reading arterial pressure sensor." 64,"FPGA reports failure reading venous pressure sensor." 65,"HD requests DG command with invalid parameter fault." - 66,"DG non-volatile calibration group invalid record CRC TODO remove this alarm after DEN-9480 fwcommon was merged into staging." + 66,"DG non-volatile calibration group invalid record CRC." 67,"HD blood pump occlusion self-test failure alarm." - 68,"HD dialysate inlet pump occlusion self-test failure alarm." - 69,"HD dialysate outlet pump occlusion self-test failure alarm." + 68,"This alarm ID is available for use." + 69,"This alarm ID is available for use." 70,"HD arterial pressure self-test failure alarm." 71,"HD venous pressure self-test failure alarm." 72,"HD blood flow meter status check self-test failure alarm." @@ -104,7 +104,7 @@ 103,"HD non-volatile calibration group invalid record CRC." 104,"Air trap level sensors reporting illegal combination of air/fluid." 105,"DG non-volatile system group invalid record CRC." - 106,"DG non-volatile service group invalid record CRC TODO remove this alarm after DEN-9480 fwcommon was merged into staging." + 106,"DG non-volatile service group invalid record CRC." 107,"HD reports DG restarted fault." 108,"HD syringe pump ADC error." 109,"HD syringe pump volume check error." @@ -141,8 +141,8 @@ 140,"Dialysate generator communication timeout." 141,"Air trap fill timeout during treatment." 142,"Blood pump occlusion detected." - 143,"Dialysate inlet pump occlusion detected." - 144,"Dialysate outlet pump occlusion detected." + 143,"This alarm ID is available for use." + 144,"This alarm ID is available for use." 145,"Concentrate conductivity after adding acid out of range alarm." 146,"Dialysate conductivity out of range." 147,"DG dialysate generation conductivity fault alarm." @@ -153,11 +153,11 @@ 152,"Inlet water pressure too low." 153,"HD prime completed high priority alarm." 154,"EEPROM operations (read, write, erase) failure." - 155,"DG non-volatile service invalid record CRC TODO remove this alarm after DEN-9480 fwcommon was merged into staging." + 155,"DG non-volatile service invalid record CRC." 156,"HW usage data (treatment time in HD and total consumed water in DG) failure." - 157,"Calibration record CRC failure TODO remove this alarm after DEN-9480 fwcommon was merged into staging." - 158,"Blood pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." - 159,"Dialysate inlet pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." + 157,"Calibration record CRC failure." + 158,"Blood pump failed flow vs motor speed check." + 159,"Dialysate inlet pump failed flow vs motor speed check." 160,"Blood pump rotor speed too high." 161,"Blood flow sensor signal strength too low." 162,"Dialysate flow sensor signal strength too low." @@ -192,7 +192,7 @@ 191,"DG flow rate out of upper range." 192,"DG flow rate out of lower range." 193,"RO pump flow rate out of range." - 194,"DG RO pump off fault." + 194,"DG RO pump duty cycle out of range." 195,"DG RO pump pressure out of range." 196,"DG temperature sensor error flag fault." 197,"DG temperature sensors ADC fault." @@ -235,8 +235,8 @@ 234,"RTC (i.e read time) or RAM operations failure (read or write)." 235,"HD in treatment stopped sub-mode after rinseback completed (no escalation)." 236,"HD needs new cartridge to be installed." - 237,"HD cartridge installed improperly alarm." - 238,"HD no cartridge loaded alarm." + 237,"This alarm ID is available for use." + 238,"HD no cartridge loaded or installed improperly alarm." 239,"HD fail to remove cartridge alarm." 240,"Bicarb conductivity out of range during bicarb pump check alarm." 241,"DG reservoir drain time out." @@ -276,8 +276,8 @@ 275,"HD arterial pressure sensor is reading out of range." 276,"HD venous pressure sensor is reading out of range." 277,"HD BP occlusion sensor is reading out of range." - 278,"HD DPi occlusion sensor is reading out of range." - 279,"HD DPo occlusion sensor is reading out of range." + 278,"This alarm ID is available for use." + 279,"This alarm ID is available for use." 280,"HD arterial pressure sensor read timeout error." 281,"Acid concentration bottle low volume alarm." 282,"Bicarbonate concentration bottle low volume alarm."