Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r1c18f738693756ca1f0342c2cc158e32bc28f90b -rac07818fa03e65ff3601535b790bb6cb4e34f731 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 1c18f738693756ca1f0342c2cc158e32bc28f90b) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision ac07818fa03e65ff3601535b790bb6cb4e34f731) @@ -7,7 +7,7 @@ * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour - * \date (last) 01-Jul-2021 + * \date (last) 05-Jul-2021 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * @@ -31,237 +31,241 @@ /*0001*/case GuiAlarmID::ALARM_ID_STUCK_BUTTON_TEST_FAILED : { result = QObject::tr("Stuck button POST failure.\nStop or Off button detected to be pressed for at least 1 second during test shortly after power up." ); break; } /*0002*/case GuiAlarmID::ALARM_ID_HD_FPGA_POST_TEST_FAILED : { result = QObject::tr("HD FPGA POST failure." ); break; } /*0003*/case GuiAlarmID::ALARM_ID_DG_FPGA_POST_TEST_FAILED : { result = QObject::tr("DG FPGA POST failure." ); break; } -/*0004*/case GuiAlarmID::ALARM_ID_WATCHDOG_POST_TEST_FAILED : { result = QObject::tr("Watchdog POST failure." ); break; } -/*0005*/case GuiAlarmID::ALARM_ID_UI_COMM_POST_FAILED : { result = QObject::tr("UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." ); break; } -/*0006*/case GuiAlarmID::ALARM_ID_RTC_CONFIG_ERROR : { result = QObject::tr("Real-time clock configuration error." ); break; } -/*0007*/case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("HD accelerometer failed POST." ); break; } -/*0008*/case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("DG accelerometer failed POST." ); break; } -/*0009*/case GuiAlarmID::ALARM_ID_RTC_OR_TIMER_ACCURACY_FAILURE : { result = QObject::tr("RTC or MCU timer inaccurate." ); break; } -/*0010*/case GuiAlarmID::ALARM_ID_DG_HEATERS_SELF_TEST_FAILURE : { result = QObject::tr("DG heaters failed POST." ); break; } -/*0011*/case GuiAlarmID::ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("HD firmware image integrity POST test failed." ); break; } -/*0012*/case GuiAlarmID::ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("DG firmware image integrity POST test failed." ); break; } -/*0013*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD blood flow invalid calibration." ); break; } -/*0014*/case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD dialysate flow invalid calibration." ); break; } -/*0015*/case GuiAlarmID::ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE : { result = QObject::tr("HD alarm audio failed POST." ); break; } -/*0016*/case GuiAlarmID::ALARM_ID_HD_SOFTWARE_FAULT : { result = QObject::tr("HD Software fault.\nSoftware found itself in an unexpected state." ); break; } -/*0017*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } -/*0018*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_OFF_CHECK : { result = QObject::tr("Blood pump failed motor off check.\nMeasured speed while commanded off." ); break; } -/*0019*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Blood pump failed motor direction check.\nMeasured vs commanded." ); break; } -/*0020*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } -/*0021*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } -/*0022*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } -/*0023*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor direction check.\nMeasured vs commanded." ); break; } -/*0024*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } -/*0025*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } -/*0026*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } -/*0027*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." ); break; } -/*0028*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } -/*0029*/case GuiAlarmID::ALARM_ID_WATCHDOG_EXPIRED : { result = QObject::tr("Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time." ); break; } -/*0030*/case GuiAlarmID::ALARM_ID_UI_COMM_TIMEOUT : { result = QObject::tr("User interface communication timeout." ); break; } -/*0031*/case GuiAlarmID::ALARM_ID_COMM_TOO_MANY_BAD_CRCS : { result = QObject::tr("Too many bad CRCs detected on received system messages." ); break; } -/*0032*/case GuiAlarmID::ALARM_ID_CAN_MESSAGE_NOT_ACKED : { result = QObject::tr("System message that required acknowledgment was not acknowledged." ); break; } -/*0033*/case GuiAlarmID::ALARM_ID_UF_RATE_TOO_HIGH_ERROR : { result = QObject::tr("Ultrafiltration rate is too high error during treatment." ); break; } -/*0034*/case GuiAlarmID::ALARM_ID_UF_VOLUME_ACCURACY_ERROR : { result = QObject::tr("Ultrafiltration volume accuracy error during treatment." ); break; } -/*0035*/case GuiAlarmID::ALARM_ID_HD_FPGA_COMM_TIMEOUT : { result = QObject::tr("HD FPGA communication down for too long." ); break; } -/*0036*/case GuiAlarmID::ALARM_ID_VALVE_CONTROL_FAILURE : { result = QObject::tr("FPGA not accepting commanded valve states." ); break; } -/*0037*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed motor speed check.\nMeasured vs commanded." ); break; } -/*0038*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed motor speed check.\nMeasured vs commanded." ); break; } -/*0039*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate outlet pump failed motor speed check.\nMeasured vs commanded." ); break; } -/*0040*/case GuiAlarmID::ALARM_ID_HD_CRITICAL_DATA_ERROR : { result = QObject::tr("HD critical data integrity check failed." ); break; } -/*0041*/case GuiAlarmID::ALARM_ID_DG_CRITICAL_DATA_ERROR : { result = QObject::tr("DG critical data integrity check failed." ); break; } -/*0042*/case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_FAILURE : { result = QObject::tr("HD accelerometer error (no readings or FPGA reports error)." ); break; } -/*0043*/case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_FAILURE : { result = QObject::tr("DG accelerometer error (no readings or FPGA reports error)." ); break; } -/*0044*/case GuiAlarmID::ALARM_ID_HD_VALVE_HOMING_FAILED : { result = QObject::tr("HD valve homing failed." ); break; } -/*0045*/case GuiAlarmID::ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT : { result = QObject::tr("HD valve transition time out." ); break; } -/*0046*/case GuiAlarmID::ALARM_ID_HD_VALVE_NOT_FUNCTIONAL : { result = QObject::tr("HD valve not functional." ); break; } -/*0047*/case GuiAlarmID::ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE : { result = QObject::tr("HD valve current out of range." ); break; } -/*0048*/case GuiAlarmID::ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE : { result = QObject::tr("HD valve position out of target." ); break; } -/*0049*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading arterial pressure sensor." ); break; } -/*0050*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading venous pressure sensor." ); break; } -/*0051*/case GuiAlarmID::ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT : { result = QObject::tr("HD requests DG command with invalid parameter fault." ); break; } -/*0052*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management overall group record CRC invalid." ); break; } -/*0053*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD blood pump occlusion self-test failure alarm." ); break; } -/*0054*/case GuiAlarmID::ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate inlet pump occlusion self-test failure alarm." ); break; } -/*0055*/case GuiAlarmID::ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate outlet pump occlusion self-test failure alarm." ); break; } -/*0056*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial pressure self-test failure alarm." ); break; } -/*0057*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous pressure self-test failure alarm." ); break; } -/*0058*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD blood flow meter status check self-test failure alarm." ); break; } -/*0059*/case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate flow meter status check self-test failure alarm." ); break; } -/*0060*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE : { result = QObject::tr("HD blood leak detector self-test failure alarm." ); break; } -/*0061*/case GuiAlarmID::ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("HD monitored voltage is out of range." ); break; } -/*0062*/case GuiAlarmID::ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG monitored voltage is out of range." ); break; } -/*0063*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from encoder) error." ); break; } -/*0064*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from controller) error." ); break; } -/*0065*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_FAULT : { result = QObject::tr("HD syringe pump fault reported by FPGA." ); break; } -/*0066*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR : { result = QObject::tr("HD syringe pump over travel error." ); break; } -/*0067*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR : { result = QObject::tr("HD syringe pump DAC write failure." ); break; } -/*0068*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR : { result = QObject::tr("HD syringe pump is running while the BP is off." ); break; } -/*0069*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR : { result = QObject::tr("HD venous pressure sensor not being read." ); break; } -/*0070*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE : { result = QObject::tr("HD venous pressure sensor temperature out of range error." ); break; } -/*0071*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD BP occlusion sensor not being read." ); break; } -/*0072*/case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPi occlusion sensor not being read." ); break; } -/*0073*/case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPo occlusion sensor not being read." ); break; } -/*0074*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD BP occlusion sensor error." ); break; } -/*0075*/case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPi occlusion sensor error." ); break; } -/*0076*/case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPo occlusion sensor error." ); break; } -/*0077*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read." ); break; } -/*0078*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD blood flow sensor error." ); break; } -/*0079*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read." ); break; } -/*0080*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD dialysate flow sensor error." ); break; } -/*0081*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read - slow packet." ); break; } -/*0082*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read - slow packet." ); break; } -/*0083*/case GuiAlarmID::ALARM_ID_HD_BATTERY_COMM_FAULT : { result = QObject::tr("HD battery communication fault." ); break; } -/*0084*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_STALL : { result = QObject::tr("HD syringe pump stall alarm." ); break; } -/*0085*/case GuiAlarmID::ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT : { result = QObject::tr("HD no cartridge self-test timeout." ); break; } -/*0086*/case GuiAlarmID::ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT : { result = QObject::tr("HD dry self-test timeout." ); break; } -/*0087*/case GuiAlarmID::ALARM_ID_RTC_COMM_ERROR : { result = QObject::tr("Real-time clock communication error." ); break; } -/*0088*/case GuiAlarmID::ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR : { result = QObject::tr("Manufacturing record CRC failure." ); break; } -/*0089*/case GuiAlarmID::ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("Air trap level sensors reporting illegal combination of air/fluid." ); break; } -/*0090*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management individual record CRC invalid." ); break; } -/*0091*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID : { result = QObject::tr("DG/HD NV data management individual record time invalid." ); break; } -/*0092*/case GuiAlarmID::ALARM_ID_DG_RESTARTED_FAULT : { result = QObject::tr("HD reports DG restarted fault." ); break; } -/*0093*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR : { result = QObject::tr("HD syringe pump ADC error." ); break; } -/*0094*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } -/*0095*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR : { result = QObject::tr("HD syringe pump speed check error." ); break; } -/*0096*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR : { result = QObject::tr("HD syringe pump not stopped in off state error." ); break; } -/*0097*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_FAULT : { result = QObject::tr("HD blood leak detector fault." ); break; } -/*0098*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial air bubble detector self-test failure." ); break; } -/*0099*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } -/*0100*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_HIGH : { result = QObject::tr("HD end of treatment alarm (high priority - user still not acting to end treatment)." ); break; } -/*0101*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK : { result = QObject::tr("Blood sitting too long after treatment stopped by user alarm (>10 min)." ); break; } -/*0102*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_DETECTED : { result = QObject::tr("HD blood leak detected alarm." ); break; } -/*0103*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_LOW : { result = QObject::tr("Venous pressure too low during treatment." ); break; } -/*0104*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED : { result = QObject::tr("HD venous air bubble detected alarm." ); break; } -/*0105*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD venous air bubble detected rinseback alarm." ); break; } -/*0106*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_HIGH : { result = QObject::tr("Venous pressure too high during treatment." ); break; } -/*0107*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_LOW : { result = QObject::tr("Arterial pressure too low during treatment." ); break; } -/*0108*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_HIGH : { result = QObject::tr("Arterial pressure too high during treatment." ); break; } -/*0109*/case GuiAlarmID::ALARM_ID_DG_FLUID_LEAK_DETECTED : { result = QObject::tr("DG fluid leak detected alarm." ); break; } -/*0110*/case GuiAlarmID::ALARM_ID_HD_FLUID_LEAK_DETECTED : { result = QObject::tr("HD fluid leak detected alarm." ); break; } -/*0111*/case GuiAlarmID::ALARM_ID_HD_SHOCK : { result = QObject::tr("HD experienced large acceleration." ); break; } -/*0112*/case GuiAlarmID::ALARM_ID_DG_SHOCK : { result = QObject::tr("DG experienced large acceleration." ); break; } -/*0113*/case GuiAlarmID::ALARM_ID_HD_EXCESSIVE_TILT : { result = QObject::tr("HD tilt exceeds maximum." ); break; } -/*0114*/case GuiAlarmID::ALARM_ID_DG_EXCESSIVE_TILT : { result = QObject::tr("DG tilt exceeds maximum." ); break; } -/*0115*/case GuiAlarmID::ALARM_ID_HD_AC_POWER_LOST : { result = QObject::tr("HD AC power lost alarm." ); break; } -/*0116*/case GuiAlarmID::ALARM_ID_DG_COMM_TIMEOUT : { result = QObject::tr("Dialysate generator communication timeout." ); break; } -/*0117*/case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } -/*0118*/case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } -/*0119*/case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_IN_PUMP : { result = QObject::tr("Dialysate inlet pump occlusion detected." ); break; } -/*0120*/case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_OUT_PUMP : { result = QObject::tr("Dialysate outlet pump occlusion detected." ); break; } -/*0121*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } -/*0122*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } -/*0123*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT : { result = QObject::tr("DG dialysate generation conductivity fault alarm." ); break; } -/*0124*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_TEMPERATURE : { result = QObject::tr("Inlet water temperature too high." ); break; } -/*0125*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_TEMPERATURE : { result = QObject::tr("Inlet water temperature too low." ); break; } -/*0126*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too high." ); break; } -/*0127*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too low." ); break; } -/*0128*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_PRESSURE : { result = QObject::tr("Inlet water pressure too low." ); break; } -/*0129*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_HIGH : { result = QObject::tr("HD prime completed high priority alarm." ); break; } -/*0130*/case GuiAlarmID::ALARM_ID_NVDATA_EEPROM_OPS_FAILURE : { result = QObject::tr("EEPROM operations (read, write, erase) failure." ); break; } -/*0131*/case GuiAlarmID::ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR : { result = QObject::tr("Service record CRC failure." ); break; } -/*0132*/case GuiAlarmID::ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR : { result = QObject::tr("HW usage data (treatment time in HD and total consumed water in DG) failure." ); break; } -/*0133*/case GuiAlarmID::ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR : { result = QObject::tr("Calibration record CRC failure." ); break; } -/*0134*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } -/*0135*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } -/*0136*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH : { result = QObject::tr("Blood pump rotor speed too high." ); break; } -/*0137*/case GuiAlarmID::ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Blood flow sensor signal strength too low." ); break; } -/*0138*/case GuiAlarmID::ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Dialysate flow sensor signal strength too low." ); break; } -/*0139*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } -/*0140*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } -/*0141*/case GuiAlarmID::ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment rinseback operation timeout." ); break; } -/*0142*/case GuiAlarmID::ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment re-circ sub-mode for too long." ); break; } -/*0143*/case GuiAlarmID::ALARM_ID_CARTRIDGE_DOOR_OPENED : { result = QObject::tr("HD cartridge door opened alarm." ); break; } -/*0144*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } -/*0145*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } -/*0146*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY : { result = QObject::tr("HD syringe empty alarm." ); break; } -/*0147*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION : { result = QObject::tr("HD syringe pump occlusion alarm." ); break; } -/*0148*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM : { result = QObject::tr("HD syringe pump not enough Heparin alarm." ); break; } -/*0149*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED : { result = QObject::tr("HD arterial air bubble detected alarm." ); break; } -/*0150*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD arterial air bubble detected rinseback alarm." ); break; } -/*0151*/case GuiAlarmID::ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR : { result = QObject::tr("HD pump direction status error." ); break; } -/*0152*/case GuiAlarmID::ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH : { result = QObject::tr("HD active reservoir is full during treatment and DG not ready to switch reservoirs." ); break; } -/*0153*/case GuiAlarmID::ALARM_ID_DG_SOFTWARE_FAULT : { result = QObject::tr("DG software fault.\nSoftware found itself in an unexpected state." ); break; } -/*0154*/case GuiAlarmID::ALARM_ID_HD_COMM_TIMEOUT : { result = QObject::tr("HD communication timeout." ); break; } -/*0155*/case GuiAlarmID::ALARM_ID_DG_FPGA_COMM_TIMEOUT : { result = QObject::tr("DG FPGA communication down for too long." ); break; } -/*0156*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELL_ADC_ERROR : { result = QObject::tr("DG load cell ADC error." ); break; } -/*0157*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE : { result = QObject::tr("DG load cells weight out of range before tare." ); break; } -/*0158*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION : { result = QObject::tr("DG load cells invalid calibration." ); break; } -/*0159*/case GuiAlarmID::ALARM_ID_DG_INVALID_LOAD_CELL_VALUE : { result = QObject::tr("DG invalid load cell value." ); break; } -/*0160*/case GuiAlarmID::ALARM_ID_UV_REACTOR_NOT_HEALTHY : { result = QObject::tr("Inlet or Outlet UV reactor not healthy." ); break; } -/*0161*/case GuiAlarmID::ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE : { result = QObject::tr("DG fan RPM out of range." ); break; } -/*0162*/case GuiAlarmID::ALARM_ID_DG_CONCENTRATE_PUMP_FAULT : { result = QObject::tr("DG concentrate pump fault." ); break; } -/*0163*/case GuiAlarmID::ALARM_ID_CP1_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP1 speed control error." ); break; } -/*0164*/case GuiAlarmID::ALARM_ID_CP2_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP2 speed control error." ); break; } -/*0165*/case GuiAlarmID::ALARM_ID_DRAIN_PUMP_RPM_OUT_OF_RANGE : { result = QObject::tr("DG drain pump RPM out of range." ); break; } -/*0166*/case GuiAlarmID::ALARM_ID_DRAIN_PUMP_OFF_FAULT : { result = QObject::tr("DG drain pump off fault." ); break; } -/*0167*/case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE : { result = QObject::tr("DG flow rate out of upper range." ); break; } -/*0168*/case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE : { result = QObject::tr("DG flow rate out of lower range." ); break; } -/*0169*/case GuiAlarmID::ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE : { result = QObject::tr("RO pump flow rate out of range." ); break; } -/*0170*/case GuiAlarmID::ALARM_ID_RO_PUMP_OFF_FAULT : { result = QObject::tr("DG RO pump off fault." ); break; } -/*0171*/case GuiAlarmID::ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE : { result = QObject::tr("DG RO pump pressure out of range." ); break; } -/*0172*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT : { result = QObject::tr("DG temperature sensor error flag fault." ); break; } -/*0173*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT : { result = QObject::tr("DG temperature sensors ADC fault." ); break; } -/*0174*/case GuiAlarmID::ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE : { result = QObject::tr("DG heaters cold junction temperature out of range." ); break; } -/*0175*/case GuiAlarmID::ALARM_ID_DG_HEATERS_FAULT : { result = QObject::tr("DG heaters fault." ); break; } -/*0176*/case GuiAlarmID::ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE : { result = QObject::tr("DG thermistors/sensors temperature out of range." ); break; } -/*0177*/case GuiAlarmID::ALARM_ID_DG_BAD_INLET_WATER_QUALITY : { result = QObject::tr("Inlet water quality is bad (temperature, conductivity, pressure)." ); break; } -/*0178*/case GuiAlarmID::ALARM_ID_INLET_WATER_PRESSURE_FAULT : { result = QObject::tr("Inlet water pressure fault." ); break; } -/*0179*/case GuiAlarmID::ALARM_ID_PRESSURE_SENSOR_FAULT : { result = QObject::tr("Pressure sensor fault." ); break; } -/*0180*/case GuiAlarmID::ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE : { result = QObject::tr("RO rejection ratio out of range." ); break; } -/*0181*/case GuiAlarmID::ALARM_ID_CONDUCTIVITY_SENSOR_FAULT : { result = QObject::tr("Conductivity sensor fault." ); break; } -/*0182*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME : { result = QObject::tr("DG dialysate fill runs out of time." ); break; } -/*0183*/case GuiAlarmID::ALARM_ID_DG_FLOW_METER_CHECK_FAILURE : { result = QObject::tr("DG flow meter check failure alarm." ); break; } -/*0184*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATERS_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heaters internal temperature out of range." ); break; } -/*0185*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater internal temperature out of range." ); break; } -/*0186*/case GuiAlarmID::ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT : { result = QObject::tr("DG heaters on with no flow time out." ); break; } -/*0187*/case GuiAlarmID::ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT : { result = QObject::tr("DG drain circulation line timeout." ); break; } -/*0188*/case GuiAlarmID::ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED : { result = QObject::tr("HD battery pack detected an error." ); break; } -/*0189*/case GuiAlarmID::ALARM_ID_BLOOD_SITTING_WARNING : { result = QObject::tr("Blood sitting too long warning (>4 min)." ); break; } -/*0190*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_ALARM : { result = QObject::tr("HD end of treatment alarm (user not acting to end treatment)." ); break; } -/*0191*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_MEDIUM : { result = QObject::tr("HD prime completed medium priority alarm." ); break; } -/*0192*/case GuiAlarmID::ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD Saline bolus volume check failure." ); break; } -/*0193*/case GuiAlarmID::ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD rinseback volume check failure." ); break; } -/*0194*/case GuiAlarmID::ALARM_ID_END_TREATMENT_TIMEOUT_ALARM : { result = QObject::tr("HD end treatment sub-mode timeout alarm." ); break; } -/*0195*/case GuiAlarmID::ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD blood prime volume check failure." ); break; } -/*0196*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_DETECTED : { result = QObject::tr("HD syringe detected alarm." ); break; } -/*0197*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED : { result = QObject::tr("HD syringe pump syringe removed alarm." ); break; } -/*0198*/case GuiAlarmID::ALARM_ID_HD_BATTERY_PACK_CHARGE_TOO_LOW : { result = QObject::tr("HD battery pack SOC is too low." ); break; } -/*0199*/case GuiAlarmID::ALARM_ID_EMPTY_SALINE_BAG : { result = QObject::tr("HD Saline bag is empty." ); break; } -/*0200*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } -/*0201*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } -/*0202*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_BY_USER : { result = QObject::tr("Treatment stopped by user action - pressed stop button." ); break; } -/*0203*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_WARNING : { result = QObject::tr("HD end of treatment warning." ); break; } -/*0204*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY : { result = QObject::tr("HD prime completed low priority alarm." ); break; } -/*0205*/case GuiAlarmID::ALARM_ID_PRIME_OUT_OF_TIME : { result = QObject::tr("HD prime out of time alarm." ); break; } -/*0206*/case GuiAlarmID::ALARM_ID_HD_PRIME_PURGE_AIR_TIME_OUT : { result = QObject::tr("HD time out on prime sub-mode purge air state." ); break; } -/*0207*/case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT : { result = QObject::tr("HD prime dialysate dialyzer time out alarm." ); break; } -/*0208*/case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT : { result = QObject::tr("HD prime dialysate bypass time out alarm." ); break; } -/*0209*/case GuiAlarmID::ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode dry self-tests failure." ); break; } -/*0210*/case GuiAlarmID::ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode wet self-tests failure." ); break; } -/*0211*/case GuiAlarmID::ALARM_ID_RTC_BATTERY_LOW : { result = QObject::tr("RTC battery low." ); break; } -/*0212*/case GuiAlarmID::ALARM_ID_RTC_RAM_OPS_ERROR : { result = QObject::tr("RTC (i.e read time) or RAM operations failure (read or write)." ); break; } -/*0213*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK : { result = QObject::tr("HD in treatment stopped sub-mode after rinseback completed (no escalation)." ); break; } -/*0214*/case GuiAlarmID::ALARM_ID_INSTALL_NEW_CARTRIDGE : { result = QObject::tr("HD needs new cartridge to be installed." ); break; } -/*0215*/case GuiAlarmID::ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY : { result = QObject::tr("HD cartridge installed improperly alarm." ); break; } -/*0216*/case GuiAlarmID::ALARM_ID_NO_CARTRIDGE_LOADED : { result = QObject::tr("HD no cartridge loaded alarm." ); break; } -/*0217*/case GuiAlarmID::ALARM_ID_CARTRIDGE_REMOVAL_FAILURE : { result = QObject::tr("HD fail to remove cartridge alarm." ); break; } -/*0218*/case GuiAlarmID::ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Bicarb conductivity out of range during bicarb pump check alarm." ); break; } -/*0219*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT : { result = QObject::tr("DG reservoir drain time out." ); break; } -/*0220*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT : { result = QObject::tr("DG reservoir fill time out." ); break; } -/*0221*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT : { result = QObject::tr("DG reservoir leak time out." ); break; } -/*0222*/case GuiAlarmID::ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensors difference out of range." ); break; } -/*0223*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG heat disinfect target temperature time out (could not reach to temperature)." ); break; } -/*0224*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG heat disinfect inlet pressure and temperature sensors out of range." ); break; } -/*0225*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG heat disinfect inlet conductivity and temperature out of range." ); break; } -/*0226*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG chemical disinfect could not reach to target temperature." ); break; } -/*0227*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG chemical disinfect inlet pressure and temperature sensors out of range." ); break; } -/*0228*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG chemical disinfect inlet conductivity and temperature out of range." ); break; } -/*0229*/case GuiAlarmID::ALARM_ID_DG_PRESSURE_SENSORS_INVALID_CALIBRATION : { result = QObject::tr("DG load cells invalid calibration." ); break; } -/*0230*/case GuiAlarmID::ALARM_ID_DG_FLOW_SENSORS_INVALID_CALIBRATION : { result = QObject::tr("DG flow sensors invalid calibration." ); break; } -/*0231*/case GuiAlarmID::ALARM_ID_DG_COND_SENSORS_INVALID_CALIBRATION : { result = QObject::tr("DG conductivity sensors invalid calibration." ); break; } -/*0232*/case GuiAlarmID::ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_NV_RECORD : { result = QObject::tr("DG drain line volume invalid non-volatile record." ); break; } -/*0233*/case GuiAlarmID::ALARM_ID_DG_RESERVOIRS_INVALID_NV_RECORD : { result = QObject::tr("DG reservoirs invalid non-volatile record." ); break; } -/*0234*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Total number of alarms." ); break; } +/*0004*/case GuiAlarmID::ALARM_ID_WATCHDOG_POST_TEST_FAILED : { result = QObject::tr("HD Watchdog POST failure." ); break; } +/*0005*/case GuiAlarmID::ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED : { result = QObject::tr("DG Watchdog POST failure." ); break; } +/*0006*/case GuiAlarmID::ALARM_ID_UI_COMM_POST_FAILED : { result = QObject::tr("UI communication POST failure.\nUI failed to communicate within a reasonable time after power up." ); break; } +/*0007*/case GuiAlarmID::ALARM_ID_RTC_CONFIG_ERROR : { result = QObject::tr("Real-time clock configuration error." ); break; } +/*0008*/case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("HD accelerometer failed POST." ); break; } +/*0009*/case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE : { result = QObject::tr("DG accelerometer failed POST." ); break; } +/*0010*/case GuiAlarmID::ALARM_ID_RTC_OR_TIMER_ACCURACY_FAILURE : { result = QObject::tr("RTC or MCU timer inaccurate." ); break; } +/*0011*/case GuiAlarmID::ALARM_ID_DG_HEATERS_SELF_TEST_FAILURE : { result = QObject::tr("DG heaters failed POST." ); break; } +/*0012*/case GuiAlarmID::ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("HD firmware image integrity POST test failed." ); break; } +/*0013*/case GuiAlarmID::ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED : { result = QObject::tr("DG firmware image integrity POST test failed." ); break; } +/*0014*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD blood flow invalid calibration." ); break; } +/*0015*/case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CALIBRATION : { result = QObject::tr("HD dialysate flow invalid calibration." ); break; } +/*0016*/case GuiAlarmID::ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE : { result = QObject::tr("HD alarm audio failed POST." ); break; } +/*0017*/case GuiAlarmID::ALARM_ID_HD_UI_POST_FAILED : { result = QObject::tr("HD UI POST failed." ); break; } +/*0018*/case GuiAlarmID::ALARM_ID_DG_PRESSURE_SENSORS_INVALID_CAL_RECORD : { result = QObject::tr("DG load cells invalid calibration record." ); break; } +/*0019*/case GuiAlarmID::ALARM_ID_DG_FLOW_SENSORS_INVALID_CAL_RECORD : { result = QObject::tr("DG flow sensors invalid calibration record." ); break; } +/*0020*/case GuiAlarmID::ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD : { result = QObject::tr("DG conductivity sensors invalid calibration record." ); break; } +/*0021*/case GuiAlarmID::ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD : { result = QObject::tr("DG drain line volume invalid calibration record." ); break; } +/*0022*/case GuiAlarmID::ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD : { result = QObject::tr("DG reservoirs invalid calibration record." ); break; } +/*0023*/case GuiAlarmID::ALARM_ID_DG_ACID_CONCENTRATE_INVALID_CAL_RECORD : { result = QObject::tr("DG acid concentrate calibration record." ); break; } +/*0024*/case GuiAlarmID::ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD : { result = QObject::tr("DG bicarb concentrate calibration record." ); break; } +/*0025*/case GuiAlarmID::ALARM_ID_HD_SOFTWARE_FAULT : { result = QObject::tr("HD Software fault.\nSoftware found itself in an unexpected state." ); break; } +/*0026*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } +/*0027*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_OFF_CHECK : { result = QObject::tr("Blood pump failed motor off check.\nMeasured speed while commanded off." ); break; } +/*0028*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Blood pump failed motor direction check.\nMeasured vs commanded." ); break; } +/*0029*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } +/*0030*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } +/*0031*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } +/*0032*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis inlet pump failed motor direction check.\nMeasured vs commanded." ); break; } +/*0033*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis inlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } +/*0034*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } +/*0035*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } +/*0036*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." ); break; } +/*0037*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } +/*0038*/case GuiAlarmID::ALARM_ID_WATCHDOG_EXPIRED : { result = QObject::tr("Watchdog expired error.\nWatchdog was not \"pet\" within the appropriate time." ); break; } +/*0039*/case GuiAlarmID::ALARM_ID_UI_COMM_TIMEOUT : { result = QObject::tr("User interface communication timeout." ); break; } +/*0040*/case GuiAlarmID::ALARM_ID_COMM_TOO_MANY_BAD_CRCS : { result = QObject::tr("Too many bad CRCs detected on received system messages." ); break; } +/*0041*/case GuiAlarmID::ALARM_ID_CAN_MESSAGE_NOT_ACKED : { result = QObject::tr("System message that required acknowledgment was not acknowledged." ); break; } +/*0042*/case GuiAlarmID::ALARM_ID_UF_RATE_TOO_HIGH_ERROR : { result = QObject::tr("Ultrafiltration rate is too high error during treatment." ); break; } +/*0043*/case GuiAlarmID::ALARM_ID_UF_VOLUME_ACCURACY_ERROR : { result = QObject::tr("Ultrafiltration volume accuracy error during treatment." ); break; } +/*0044*/case GuiAlarmID::ALARM_ID_HD_FPGA_COMM_TIMEOUT : { result = QObject::tr("HD FPGA communication down for too long." ); break; } +/*0045*/case GuiAlarmID::ALARM_ID_VALVE_CONTROL_FAILURE : { result = QObject::tr("FPGA not accepting commanded valve states." ); break; } +/*0046*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed motor speed check.\nMeasured vs commanded." ); break; } +/*0047*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed motor speed check.\nMeasured vs commanded." ); break; } +/*0048*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate outlet pump failed motor speed check.\nMeasured vs commanded." ); break; } +/*0049*/case GuiAlarmID::ALARM_ID_HD_CRITICAL_DATA_ERROR : { result = QObject::tr("HD critical data integrity check failed." ); break; } +/*0050*/case GuiAlarmID::ALARM_ID_DG_CRITICAL_DATA_ERROR : { result = QObject::tr("DG critical data integrity check failed." ); break; } +/*0051*/case GuiAlarmID::ALARM_ID_HD_ACCELEROMETER_FAILURE : { result = QObject::tr("HD accelerometer error (no readings or FPGA reports error)." ); break; } +/*0052*/case GuiAlarmID::ALARM_ID_DG_ACCELEROMETER_FAILURE : { result = QObject::tr("DG accelerometer error (no readings or FPGA reports error)." ); break; } +/*0053*/case GuiAlarmID::ALARM_ID_HD_VALVE_HOMING_FAILED : { result = QObject::tr("HD valve homing failed." ); break; } +/*0054*/case GuiAlarmID::ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT : { result = QObject::tr("HD valve transition time out." ); break; } +/*0055*/case GuiAlarmID::ALARM_ID_HD_VALVE_NOT_FUNCTIONAL : { result = QObject::tr("HD valve not functional." ); break; } +/*0056*/case GuiAlarmID::ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE : { result = QObject::tr("HD valve current out of range." ); break; } +/*0057*/case GuiAlarmID::ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE : { result = QObject::tr("HD valve position out of target." ); break; } +/*0058*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading arterial pressure sensor." ); break; } +/*0059*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading venous pressure sensor." ); break; } +/*0060*/case GuiAlarmID::ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT : { result = QObject::tr("HD requests DG command with invalid parameter fault." ); break; } +/*0061*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management overall group record CRC invalid." ); break; } +/*0062*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD blood pump occlusion self-test failure alarm." ); break; } +/*0063*/case GuiAlarmID::ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate inlet pump occlusion self-test failure alarm." ); break; } +/*0064*/case GuiAlarmID::ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate outlet pump occlusion self-test failure alarm." ); break; } +/*0065*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial pressure self-test failure alarm." ); break; } +/*0066*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous pressure self-test failure alarm." ); break; } +/*0067*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD blood flow meter status check self-test failure alarm." ); break; } +/*0068*/case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate flow meter status check self-test failure alarm." ); break; } +/*0069*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE : { result = QObject::tr("HD blood leak detector self-test failure alarm." ); break; } +/*0070*/case GuiAlarmID::ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("HD monitored voltage is out of range." ); break; } +/*0071*/case GuiAlarmID::ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG monitored voltage is out of range." ); break; } +/*0072*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from encoder) error." ); break; } +/*0073*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR : { result = QObject::tr("HD syringe pump direction (from controller) error." ); break; } +/*0074*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_FAULT : { result = QObject::tr("HD syringe pump fault reported by FPGA." ); break; } +/*0075*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR : { result = QObject::tr("HD syringe pump over travel error." ); break; } +/*0076*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR : { result = QObject::tr("HD syringe pump DAC write failure." ); break; } +/*0077*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR : { result = QObject::tr("HD syringe pump is running while the BP is off." ); break; } +/*0078*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR : { result = QObject::tr("HD venous pressure sensor not being read." ); break; } +/*0079*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE : { result = QObject::tr("HD venous pressure sensor temperature out of range error." ); break; } +/*0080*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD BP occlusion sensor not being read." ); break; } +/*0081*/case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPi occlusion sensor not being read." ); break; } +/*0082*/case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR : { result = QObject::tr("HD DPo occlusion sensor not being read." ); break; } +/*0083*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD BP occlusion sensor error." ); break; } +/*0084*/case GuiAlarmID::ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPi occlusion sensor error." ); break; } +/*0085*/case GuiAlarmID::ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR : { result = QObject::tr("HD DPo occlusion sensor error." ); break; } +/*0086*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read." ); break; } +/*0087*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD blood flow sensor error." ); break; } +/*0088*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read." ); break; } +/*0089*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SENSOR_ERROR : { result = QObject::tr("HD dialysate flow sensor error." ); break; } +/*0090*/case GuiAlarmID::ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD blood flow sensor not being read - slow packet." ); break; } +/*0091*/case GuiAlarmID::ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR : { result = QObject::tr("HD dialysate flow sensor not being read - slow packet." ); break; } +/*0092*/case GuiAlarmID::ALARM_ID_HD_BATTERY_COMM_FAULT : { result = QObject::tr("HD battery communication fault." ); break; } +/*0093*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_STALL : { result = QObject::tr("HD syringe pump stall alarm." ); break; } +/*0094*/case GuiAlarmID::ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT : { result = QObject::tr("HD no cartridge self-test timeout." ); break; } +/*0095*/case GuiAlarmID::ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT : { result = QObject::tr("HD dry self-test timeout." ); break; } +/*0096*/case GuiAlarmID::ALARM_ID_RTC_COMM_ERROR : { result = QObject::tr("Real-time clock communication error." ); break; } +/*0097*/case GuiAlarmID::ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR : { result = QObject::tr("Manufacturing record CRC failure." ); break; } +/*0098*/case GuiAlarmID::ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("Air trap level sensors reporting illegal combination of air/fluid." ); break; } +/*0099*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID : { result = QObject::tr("DG/HD NV data management individual record CRC invalid." ); break; } +/*0100*/case GuiAlarmID::ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID : { result = QObject::tr("DG/HD NV data management individual record time invalid." ); break; } +/*0101*/case GuiAlarmID::ALARM_ID_DG_RESTARTED_FAULT : { result = QObject::tr("HD reports DG restarted fault." ); break; } +/*0102*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR : { result = QObject::tr("HD syringe pump ADC error." ); break; } +/*0103*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } +/*0104*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR : { result = QObject::tr("HD syringe pump speed check error." ); break; } +/*0105*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR : { result = QObject::tr("HD syringe pump not stopped in off state error." ); break; } +/*0106*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_FAULT : { result = QObject::tr("HD blood leak detector fault." ); break; } +/*0107*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial air bubble detector self-test failure." ); break; } +/*0108*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } +/*0109*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_HIGH : { result = QObject::tr("HD end of treatment alarm (high priority - user still not acting to end treatment)." ); break; } +/*0110*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK : { result = QObject::tr("Blood sitting too long after treatment stopped by user alarm (>10 min)." ); break; } +/*0111*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_DETECTED : { result = QObject::tr("HD blood leak detected alarm." ); break; } +/*0112*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_LOW : { result = QObject::tr("Venous pressure too low during treatment." ); break; } +/*0113*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED : { result = QObject::tr("HD venous air bubble detected alarm." ); break; } +/*0114*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD venous air bubble detected rinseback alarm." ); break; } +/*0115*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_HIGH : { result = QObject::tr("Venous pressure too high during treatment." ); break; } +/*0116*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_LOW : { result = QObject::tr("Arterial pressure too low during treatment." ); break; } +/*0117*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_HIGH : { result = QObject::tr("Arterial pressure too high during treatment." ); break; } +/*0118*/case GuiAlarmID::ALARM_ID_DG_FLUID_LEAK_DETECTED : { result = QObject::tr("DG fluid leak detected alarm." ); break; } +/*0119*/case GuiAlarmID::ALARM_ID_HD_FLUID_LEAK_DETECTED : { result = QObject::tr("HD fluid leak detected alarm." ); break; } +/*0120*/case GuiAlarmID::ALARM_ID_HD_SHOCK : { result = QObject::tr("HD experienced large acceleration." ); break; } +/*0121*/case GuiAlarmID::ALARM_ID_DG_SHOCK : { result = QObject::tr("DG experienced large acceleration." ); break; } +/*0122*/case GuiAlarmID::ALARM_ID_HD_EXCESSIVE_TILT : { result = QObject::tr("HD tilt exceeds maximum." ); break; } +/*0123*/case GuiAlarmID::ALARM_ID_DG_EXCESSIVE_TILT : { result = QObject::tr("DG tilt exceeds maximum." ); break; } +/*0124*/case GuiAlarmID::ALARM_ID_HD_AC_POWER_LOST : { result = QObject::tr("HD AC power lost alarm." ); break; } +/*0125*/case GuiAlarmID::ALARM_ID_DG_COMM_TIMEOUT : { result = QObject::tr("Dialysate generator communication timeout." ); break; } +/*0126*/case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } +/*0127*/case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } +/*0128*/case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_IN_PUMP : { result = QObject::tr("Dialysate inlet pump occlusion detected." ); break; } +/*0129*/case GuiAlarmID::ALARM_ID_OCCLUSION_DIAL_OUT_PUMP : { result = QObject::tr("Dialysate outlet pump occlusion detected." ); break; } +/*0130*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } +/*0131*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } +/*0132*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT : { result = QObject::tr("DG dialysate generation conductivity fault alarm." ); break; } +/*0133*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_TEMPERATURE : { result = QObject::tr("Inlet water temperature too high." ); break; } +/*0134*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_TEMPERATURE : { result = QObject::tr("Inlet water temperature too low." ); break; } +/*0135*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too high." ); break; } +/*0136*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too low." ); break; } +/*0137*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_PRESSURE : { result = QObject::tr("Inlet water pressure too low." ); break; } +/*0138*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_HIGH : { result = QObject::tr("HD prime completed high priority alarm." ); break; } +/*0139*/case GuiAlarmID::ALARM_ID_NVDATA_EEPROM_OPS_FAILURE : { result = QObject::tr("EEPROM operations (read, write, erase) failure." ); break; } +/*0140*/case GuiAlarmID::ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR : { result = QObject::tr("Service record CRC failure." ); break; } +/*0141*/case GuiAlarmID::ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR : { result = QObject::tr("HW usage data (treatment time in HD and total consumed water in DG) failure." ); break; } +/*0142*/case GuiAlarmID::ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR : { result = QObject::tr("Calibration record CRC failure." ); break; } +/*0143*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Blood pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } +/*0144*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed flow vs motor speed check.\nMismatch with flow rate and rate implied by motor speed." ); break; } +/*0145*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH : { result = QObject::tr("Blood pump rotor speed too high." ); break; } +/*0146*/case GuiAlarmID::ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Blood flow sensor signal strength too low." ); break; } +/*0147*/case GuiAlarmID::ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW : { result = QObject::tr("Dialysate flow sensor signal strength too low." ); break; } +/*0148*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } +/*0149*/case GuiAlarmID::ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM : { result = QObject::tr("HD sees primary load cell for reservoir 1 change too much too fast." ); break; } +/*0150*/case GuiAlarmID::ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment rinseback operation timeout." ); break; } +/*0151*/case GuiAlarmID::ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM : { result = QObject::tr("HD in treatment re-circ sub-mode for too long." ); break; } +/*0152*/case GuiAlarmID::ALARM_ID_CARTRIDGE_DOOR_OPENED : { result = QObject::tr("HD cartridge door opened alarm." ); break; } +/*0153*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } +/*0154*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } +/*0155*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY : { result = QObject::tr("HD syringe empty alarm." ); break; } +/*0156*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION : { result = QObject::tr("HD syringe pump occlusion alarm." ); break; } +/*0157*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM : { result = QObject::tr("HD syringe pump not enough Heparin alarm." ); break; } +/*0158*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED : { result = QObject::tr("HD arterial air bubble detected alarm." ); break; } +/*0159*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK : { result = QObject::tr("HD arterial air bubble detected rinseback alarm." ); break; } +/*0160*/case GuiAlarmID::ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR : { result = QObject::tr("HD pump direction status error." ); break; } +/*0161*/case GuiAlarmID::ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH : { result = QObject::tr("HD active reservoir is full during treatment and DG not ready to switch reservoirs." ); break; } +/*0162*/case GuiAlarmID::ALARM_ID_DG_SOFTWARE_FAULT : { result = QObject::tr("DG software fault.\nSoftware found itself in an unexpected state." ); break; } +/*0163*/case GuiAlarmID::ALARM_ID_HD_COMM_TIMEOUT : { result = QObject::tr("HD communication timeout." ); break; } +/*0164*/case GuiAlarmID::ALARM_ID_DG_FPGA_COMM_TIMEOUT : { result = QObject::tr("DG FPGA communication down for too long." ); break; } +/*0165*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELL_ADC_ERROR : { result = QObject::tr("DG load cell ADC error." ); break; } +/*0166*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE : { result = QObject::tr("DG load cells weight out of range before tare." ); break; } +/*0167*/case GuiAlarmID::ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION : { result = QObject::tr("DG load cells invalid calibration." ); break; } +/*0168*/case GuiAlarmID::ALARM_ID_DG_INVALID_LOAD_CELL_VALUE : { result = QObject::tr("DG invalid load cell value." ); break; } +/*0169*/case GuiAlarmID::ALARM_ID_UV_REACTOR_NOT_HEALTHY : { result = QObject::tr("Inlet or Outlet UV reactor not healthy." ); break; } +/*0170*/case GuiAlarmID::ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE : { result = QObject::tr("DG fan RPM out of range." ); break; } +/*0171*/case GuiAlarmID::ALARM_ID_DG_CONCENTRATE_PUMP_FAULT : { result = QObject::tr("DG concentrate pump fault." ); break; } +/*0172*/case GuiAlarmID::ALARM_ID_CP1_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP1 speed control error." ); break; } +/*0173*/case GuiAlarmID::ALARM_ID_CP2_SPEED_CONTROL_ERROR : { result = QObject::tr("DG concentrate pump CP2 speed control error." ); break; } +/*0174*/case GuiAlarmID::ALARM_ID_DRAIN_PUMP_RPM_OUT_OF_RANGE : { result = QObject::tr("DG drain pump RPM out of range." ); break; } +/*0175*/case GuiAlarmID::ALARM_ID_DRAIN_PUMP_OFF_FAULT : { result = QObject::tr("DG drain pump off fault." ); break; } +/*0176*/case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE : { result = QObject::tr("DG flow rate out of upper range." ); break; } +/*0177*/case GuiAlarmID::ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE : { result = QObject::tr("DG flow rate out of lower range." ); break; } +/*0178*/case GuiAlarmID::ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE : { result = QObject::tr("RO pump flow rate out of range." ); break; } +/*0179*/case GuiAlarmID::ALARM_ID_RO_PUMP_OFF_FAULT : { result = QObject::tr("DG RO pump off fault." ); break; } +/*0180*/case GuiAlarmID::ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE : { result = QObject::tr("DG RO pump pressure out of range." ); break; } +/*0181*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT : { result = QObject::tr("DG temperature sensor error flag fault." ); break; } +/*0182*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT : { result = QObject::tr("DG temperature sensors ADC fault." ); break; } +/*0183*/case GuiAlarmID::ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE : { result = QObject::tr("DG heaters cold junction temperature out of range." ); break; } +/*0184*/case GuiAlarmID::ALARM_ID_DG_HEATERS_FAULT : { result = QObject::tr("DG heaters fault." ); break; } +/*0185*/case GuiAlarmID::ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE : { result = QObject::tr("DG thermistors/sensors temperature out of range." ); break; } +/*0186*/case GuiAlarmID::ALARM_ID_DG_BAD_INLET_WATER_QUALITY : { result = QObject::tr("Inlet water quality is bad (temperature, conductivity, pressure)." ); break; } +/*0187*/case GuiAlarmID::ALARM_ID_INLET_WATER_PRESSURE_FAULT : { result = QObject::tr("Inlet water pressure fault." ); break; } +/*0188*/case GuiAlarmID::ALARM_ID_PRESSURE_SENSOR_FAULT : { result = QObject::tr("Pressure sensor fault." ); break; } +/*0189*/case GuiAlarmID::ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE : { result = QObject::tr("RO rejection ratio out of range." ); break; } +/*0190*/case GuiAlarmID::ALARM_ID_CONDUCTIVITY_SENSOR_FAULT : { result = QObject::tr("Conductivity sensor fault." ); break; } +/*0191*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME : { result = QObject::tr("DG dialysate fill runs out of time." ); break; } +/*0192*/case GuiAlarmID::ALARM_ID_DG_FLOW_METER_CHECK_FAILURE : { result = QObject::tr("DG flow meter check failure alarm." ); break; } +/*0193*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATERS_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heaters internal temperature out of range." ); break; } +/*0194*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater internal temperature out of range." ); break; } +/*0195*/case GuiAlarmID::ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT : { result = QObject::tr("DG heaters on with no flow time out." ); break; } +/*0196*/case GuiAlarmID::ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT : { result = QObject::tr("DG drain circulation line timeout." ); break; } +/*0197*/case GuiAlarmID::ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED : { result = QObject::tr("HD battery pack detected an error." ); break; } +/*0198*/case GuiAlarmID::ALARM_ID_BLOOD_SITTING_WARNING : { result = QObject::tr("Blood sitting too long warning (>4 min)." ); break; } +/*0199*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_ALARM : { result = QObject::tr("HD end of treatment alarm (user not acting to end treatment)." ); break; } +/*0200*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_MEDIUM : { result = QObject::tr("HD prime completed medium priority alarm." ); break; } +/*0201*/case GuiAlarmID::ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD Saline bolus volume check failure." ); break; } +/*0202*/case GuiAlarmID::ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD rinseback volume check failure." ); break; } +/*0203*/case GuiAlarmID::ALARM_ID_END_TREATMENT_TIMEOUT_ALARM : { result = QObject::tr("HD end treatment sub-mode timeout alarm." ); break; } +/*0204*/case GuiAlarmID::ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD blood prime volume check failure." ); break; } +/*0205*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_DETECTED : { result = QObject::tr("HD syringe detected alarm." ); break; } +/*0206*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED : { result = QObject::tr("HD syringe pump syringe removed alarm." ); break; } +/*0207*/case GuiAlarmID::ALARM_ID_HD_BATTERY_PACK_CHARGE_TOO_LOW : { result = QObject::tr("HD battery pack SOC is too low." ); break; } +/*0208*/case GuiAlarmID::ALARM_ID_EMPTY_SALINE_BAG : { result = QObject::tr("HD Saline bag is empty." ); break; } +/*0209*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } +/*0210*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } +/*0211*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_BY_USER : { result = QObject::tr("Treatment stopped by user action - pressed stop button." ); break; } +/*0212*/case GuiAlarmID::ALARM_ID_END_OF_TREATMENT_WARNING : { result = QObject::tr("HD end of treatment warning." ); break; } +/*0213*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY : { result = QObject::tr("HD prime completed low priority alarm." ); break; } +/*0214*/case GuiAlarmID::ALARM_ID_PRIME_OUT_OF_TIME : { result = QObject::tr("HD prime out of time alarm." ); break; } +/*0215*/case GuiAlarmID::ALARM_ID_HD_PRIME_PURGE_AIR_TIME_OUT : { result = QObject::tr("HD time out on prime sub-mode purge air state." ); break; } +/*0216*/case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT : { result = QObject::tr("HD prime dialysate dialyzer time out alarm." ); break; } +/*0217*/case GuiAlarmID::ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT : { result = QObject::tr("HD prime dialysate bypass time out alarm." ); break; } +/*0218*/case GuiAlarmID::ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode dry self-tests failure." ); break; } +/*0219*/case GuiAlarmID::ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE : { result = QObject::tr("HD pre-treatment mode wet self-tests failure." ); break; } +/*0220*/case GuiAlarmID::ALARM_ID_RTC_BATTERY_LOW : { result = QObject::tr("RTC battery low." ); break; } +/*0221*/case GuiAlarmID::ALARM_ID_RTC_RAM_OPS_ERROR : { result = QObject::tr("RTC (i.e read time) or RAM operations failure (read or write)." ); break; } +/*0222*/case GuiAlarmID::ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK : { result = QObject::tr("HD in treatment stopped sub-mode after rinseback completed (no escalation)." ); break; } +/*0223*/case GuiAlarmID::ALARM_ID_INSTALL_NEW_CARTRIDGE : { result = QObject::tr("HD needs new cartridge to be installed." ); break; } +/*0224*/case GuiAlarmID::ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY : { result = QObject::tr("HD cartridge installed improperly alarm." ); break; } +/*0225*/case GuiAlarmID::ALARM_ID_NO_CARTRIDGE_LOADED : { result = QObject::tr("HD no cartridge loaded alarm." ); break; } +/*0226*/case GuiAlarmID::ALARM_ID_CARTRIDGE_REMOVAL_FAILURE : { result = QObject::tr("HD fail to remove cartridge alarm." ); break; } +/*0227*/case GuiAlarmID::ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Bicarb conductivity out of range during bicarb pump check alarm." ); break; } +/*0228*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT : { result = QObject::tr("DG reservoir drain time out." ); break; } +/*0229*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT : { result = QObject::tr("DG reservoir fill time out." ); break; } +/*0230*/case GuiAlarmID::ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT : { result = QObject::tr("DG reservoir leak time out." ); break; } +/*0231*/case GuiAlarmID::ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensors difference out of range." ); break; } +/*0232*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG heat disinfect target temperature time out (could not reach to temperature)." ); break; } +/*0233*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG heat disinfect inlet pressure and temperature sensors out of range." ); break; } +/*0234*/case GuiAlarmID::ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG heat disinfect inlet conductivity and temperature out of range." ); break; } +/*0235*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT : { result = QObject::tr("DG chemical disinfect could not reach to target temperature." ); break; } +/*0236*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT: { result = QObject::tr("DG chemical disinfect inlet pressure and temperature sensors out of range." ); break; } +/*0237*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT : { result = QObject::tr("DG chemical disinfect inlet conductivity and temperature out of range." ); break; } +/*0238*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Total number of alarms." ); break; } default: result = QObject::tr("ALARM_ID_UNDEFINED [%1]").arg(int(vAlarmID));