Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r3561f79af1a92356eea01d5d0c3297c69d2ecdf2 -rdf0329c47627ceb1fe460cda2ae3ff8c9c851106 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 3561f79af1a92356eea01d5d0c3297c69d2ecdf2) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision df0329c47627ceb1fe460cda2ae3ff8c9c851106) @@ -7,7 +7,7 @@ * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour - * \date (last) 28-Mar-2022 + * \date (last) 02-Apr-2022 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * @@ -129,8 +129,8 @@ /*0093*/case GuiAlarmID::ALARM_ID____AVAILABLE_15 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 93*/ /*0094*/case GuiAlarmID::ALARM_ID____AVAILABLE_16 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 94*/ /*0095*/case GuiAlarmID::ALARM_ID____AVAILABLE_17 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 95*/ -/*0096*/case GuiAlarmID::ALARM_ID____AVAILABLE_18 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 96*/ -/*0097*/case GuiAlarmID::ALARM_ID____AVAILABLE_19 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 97*/ +/*0096*/case GuiAlarmID::ALARM_ID_INLET_WATER_TEMPERATURE_IN_HIGH_RANGE : { result = QObject::tr("Inlet water temperature in high range." ); break; } /* 96*/ +/*0097*/case GuiAlarmID::ALARM_ID_FILL_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Fill conductivity out of range." ); break; } /* 97*/ /*0098*/case GuiAlarmID::ALARM_ID_HD_BATTERY_COMM_FAULT : { result = QObject::tr("HD battery communication fault." ); break; } /* 98*/ /*0099*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_STALL : { result = QObject::tr("HD syringe pump stall alarm." ); break; } /* 99*/ /*0100*/case GuiAlarmID::ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT : { result = QObject::tr("HD no cartridge self-test timeout." ); break; } /* 100*/ @@ -139,7 +139,7 @@ /*0103*/case GuiAlarmID::ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("HD non-volatile calibration group invalid record CRC." ); break; } /* 103*/ /*0104*/case GuiAlarmID::ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("Air trap level sensors reporting illegal combination of air/fluid." ); break; } /* 104*/ /*0105*/case GuiAlarmID::ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("DG non-volatile system group invalid record CRC." ); break; } /* 105*/ -/*0106*/case GuiAlarmID::ALARM_ID____AVAILABLE_20 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 106*/ +/*0106*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY : { result = QObject::tr("DG inlet water conductivity is greater than threshold." ); break; } /* 106*/ /*0107*/case GuiAlarmID::ALARM_ID_DG_RESTARTED_FAULT : { result = QObject::tr("HD reports DG restarted fault." ); break; } /* 107*/ /*0108*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR : { result = QObject::tr("HD syringe pump ADC error." ); break; } /* 108*/ /*0109*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } /* 109*/ @@ -150,10 +150,10 @@ /*0114*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } /* 114*/ /*0115*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor out of range." ); break; } /* 115*/ /*0116*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor ADC out of range." ); break; } /* 116*/ -/*0117*/case GuiAlarmID::ALARM_ID____AVAILABLE_28 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 117*/ -/*0118*/case GuiAlarmID::ALARM_ID____AVAILABLE_29 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 118*/ -/*0119*/case GuiAlarmID::ALARM_ID____AVAILABLE_30 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 119*/ -/*0120*/case GuiAlarmID::ALARM_ID____AVAILABLE_31 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 120*/ +/*0117*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heater internal temperature out of range." ); break; } /* 117*/ +/*0118*/case GuiAlarmID::ALARM_ID_DG_PRIMARY_HEATER_CJ_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG primary heater cold junction temperature out of range." ); break; } /* 118*/ +/*0119*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater internal temperature out of range." ); break; } /* 119*/ +/*0120*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_CJ_TEMP_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater cold junction temperature out of range." ); break; } /* 120*/ /*0121*/case GuiAlarmID::ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG main primary heater voltage out of range." ); break; } /* 121*/ /*0122*/case GuiAlarmID::ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG small primary heater voltage out of range." ); break; } /* 122*/ /*0123*/case GuiAlarmID::ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG trimmer heater voltage out of range." ); break; } /* 123*/ @@ -180,18 +180,18 @@ /*0144*/case GuiAlarmID::ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC : { result = QObject::tr("DG software configuration record invalid CRC." ); break; } /* 144*/ /*0145*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } /* 145*/ /*0146*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } /* 146*/ -/*0147*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT : { result = QObject::tr("DG dialysate generation conductivity fault alarm." ); break; } /* 147*/ +/*0147*/case GuiAlarmID::ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT : { result = QObject::tr("Wait for the DG to produce dialysate." ); break; } /* 147*/ /*0148*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_TEMPERATURE : { result = QObject::tr("Inlet water temperature too high." ); break; } /* 148*/ -/*0149*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_TEMPERATURE : { result = QObject::tr("Inlet water temperature too low." ); break; } /* 149*/ -/*0150*/case GuiAlarmID::ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too high." ); break; } /* 150*/ -/*0151*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY : { result = QObject::tr("Inlet water conductivity too low." ); break; } /* 151*/ -/*0152*/case GuiAlarmID::ALARM_ID_INLET_WATER_LOW_PRESSURE : { result = QObject::tr("Inlet water pressure too low." ); break; } /* 152*/ +/*0149*/case GuiAlarmID::ALARM_ID____AVAILABLE_28 : { result = QObject::tr("Alarm ID available for use." ); break; } /* 149*/ +/*0150*/case GuiAlarmID::ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_HIGH_RANGE : { result = QObject::tr("Inlet water conductivity in high range." ); break; } /* 150*/ +/*0151*/case GuiAlarmID::ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE : { result = QObject::tr("Inlet water conductivity in low range." ); break; } /* 151*/ +/*0152*/case GuiAlarmID::ALARM_ID_INLET_WATER_PRESSURE_IN_LOW_RANGE : { result = QObject::tr("Inlet water pressure in low range." ); break; } /* 152*/ /*0153*/case GuiAlarmID::ALARM_ID_PRIME_COMPLETED_HIGH : { result = QObject::tr("HD prime completed high priority alarm." ); break; } /* 153*/ /*0154*/case GuiAlarmID::ALARM_ID_NVDATA_EEPROM_OPS_FAILURE : { result = QObject::tr("EEPROM operations (read, write, erase) failure." ); break; } /* 154*/ /*0155*/case GuiAlarmID::ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC : { result = QObject::tr("DG software configuration record invalid CRC." ); break; } /* 155*/ /*0156*/case GuiAlarmID::ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR : { result = QObject::tr("HW usage data (treatment time in HD and total consumed water in DG) failure." ); break; } /* 156*/ /*0157*/case GuiAlarmID::ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT : { result = QObject::tr("DG chemical disinfect prime acid line timeout." ); break; } /* 157*/ -/*0158*/case GuiAlarmID::ALARM_ID____AVAILABLE_24 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 158*/ +/*0158*/case GuiAlarmID::ALARM_ID_INLET_WATER_TEMPERATURE_IN_LOW_RANGE : { result = QObject::tr("Inlet water temperature is in the low range." ); break; } /* 158*/ /*0159*/case GuiAlarmID::ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK : { result = QObject::tr("Dialysate inlet pump failed flow vs motor speed check." ); break; } /* 159*/ /*0160*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH : { result = QObject::tr("Blood pump rotor speed too high." ); break; } /* 160*/ /*0161*/case GuiAlarmID::ALARM_ID____AVAILABLE_26 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 161*/