Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -r3e552c42843a6e0966414a85dfbcdc47001d116c -rdd95fe29695cd5dd9cfa6e0bd723ea027fd40c72 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision 3e552c42843a6e0966414a85dfbcdc47001d116c) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision dd95fe29695cd5dd9cfa6e0bd723ea027fd40c72) @@ -76,7 +76,7 @@ /*0040*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor off check.\nMeasured speed while commanded off." ); break; } /* 40*/ /*0041*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK : { result = QObject::tr("Dialysis outlet pump failed motor direction check.\nMeasured vs commanded." ); break; } /* 41*/ /*0042*/case GuiAlarmID::ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK : { result = QObject::tr("Dialysis outlet pump failed rotor speed check.\nMismatch with rotor and motor speeds." ); break; } /* 42*/ -/*0043*/case GuiAlarmID::ALARM_ID__AVAILABLE_3 : { result = QObject::tr("Alarm ID available for use." ); break; } /* 43*/ +/*0043*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAULT : { result = QObject::tr("HD blood leak self test fault." ); break; } /* 43*/ /*0044*/case GuiAlarmID::ALARM_ID_UI_COMM_TIMEOUT : { result = QObject::tr("User interface communication timeout." ); break; } /* 44*/ /*0045*/case GuiAlarmID::ALARM_ID_HD_COMM_TOO_MANY_BAD_CRCS : { result = QObject::tr("HD too many bad communications CRC." ); break; } /* 45*/ /*0046*/case GuiAlarmID::ALARM_ID_CAN_MESSAGE_NOT_ACKED : { result = QObject::tr("System message that required acknowledgment was not acknowledged." ); break; } /* 46*/ @@ -107,7 +107,7 @@ /*0071*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous pressure self-test failure alarm." ); break; } /* 71*/ /*0072*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD blood flow meter status check self-test failure alarm." ); break; } /* 72*/ /*0073*/case GuiAlarmID::ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD dialysate flow meter status check self-test failure alarm." ); break; } /* 73*/ -/*0074*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE : { result = QObject::tr("HD blood leak detector self-test failure alarm." ); break; } /* 74*/ +/*0074*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_SEND_TIMEOUT : { result = QObject::tr("HD blood leak detector self-test transmit timeout." ); break; } /* 74*/ /*0075*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE : { result = QObject::tr("HD syringe pump self-test failure alarm." ); break; } /* 75*/ /*0076*/case GuiAlarmID::ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("HD monitored voltage is out of range." ); break; } /* 76*/ /*0077*/case GuiAlarmID::ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE : { result = QObject::tr("DG monitored voltage is out of range." ); break; } /* 77*/ @@ -145,8 +145,8 @@ /*0109*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } /* 109*/ /*0110*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR : { result = QObject::tr("HD syringe pump speed check error." ); break; } /* 110*/ /*0111*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR : { result = QObject::tr("HD syringe pump not stopped in off state error." ); break; } /* 111*/ -/*0112*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_ZERO_CMD_TIMEOUT : { result = QObject::tr("HD blood leak zero command timeout." ); break; } /* 112*/ -/*0113*/case GuiAlarmID::ALARM_ID__AVAILABLE_4 : { result = QObject::tr("Unused." ); break; } /* 113*/ +/*0112*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_ZERO_CMD_SEND_TIMEOUT : { result = QObject::tr("HD blood leak zero command transmit timeout." ); break; } /* 112*/ +/*0113*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_ZERO_CMD_FAULT : { result = QObject::tr("HD blood leak zero command fault." ); break; } /* 113*/ /*0114*/case GuiAlarmID::ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous air bubble detector self-test failure." ); break; } /* 114*/ /*0115*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor out of range." ); break; } /* 115*/ /*0116*/case GuiAlarmID::ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE : { result = QObject::tr("DG temperature sensor ADC out of range." ); break; } /* 116*/