Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -rec36df2f94c93e62095f49c7f65a30c2d508a579 -rb4afeb74791459712ab0ad43f0f3ac1a75d8baed --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision ec36df2f94c93e62095f49c7f65a30c2d508a579) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision b4afeb74791459712ab0ad43f0f3ac1a75d8baed) @@ -99,10 +99,10 @@ /*0063*/case GuiAlarmID::ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading arterial pressure sensor." ); break; } /* 63*/ /*0064*/case GuiAlarmID::ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT : { result = QObject::tr("FPGA reports failure reading venous pressure sensor." ); break; } /* 64*/ /*0065*/case GuiAlarmID::ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT : { result = QObject::tr("HD requests DG command with invalid parameter fault." ); break; } /* 65*/ -/*0066*/case GuiAlarmID::ALARM_ID____AVAILABLE_21 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 66*/ +/*0066*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE : { result = QObject::tr("HD blood leak sensor set point set failure." ); break; } /* 66*/ /*0067*/case GuiAlarmID::ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE : { result = QObject::tr("HD blood pump occlusion self-test failure alarm." ); break; } /* 67*/ /*0068*/case GuiAlarmID::ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE : { result = QObject::tr("HD active reservoir recirculation out of range." ); break; } /* 68*/ -/*0069*/case GuiAlarmID::ALARM_ID____AVAILABLE_6 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 69*/ +/*0069*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD : { result = QObject::tr("HD blood leak sensor invalid calibration record." ); break; } /* 69*/ /*0070*/case GuiAlarmID::ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD arterial pressure self-test failure alarm." ); break; } /* 70*/ /*0071*/case GuiAlarmID::ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE : { result = QObject::tr("HD venous pressure self-test failure alarm." ); break; } /* 71*/ /*0072*/case GuiAlarmID::ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE : { result = QObject::tr("HD blood flow meter status check self-test failure alarm." ); break; } /* 72*/ @@ -176,7 +176,7 @@ /*0140*/case GuiAlarmID::ALARM_ID_DG_COMM_TIMEOUT : { result = QObject::tr("Dialysate generator communication timeout." ); break; } /* 140*/ /*0141*/case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } /* 141*/ /*0142*/case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } /* 142*/ -/*0143*/case GuiAlarmID::ALARM_ID____AVAILABLE_8 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 143*/ +/*0143*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT : { result = QObject::tr("DG dialysate temperature sensors drift timeout." ); break; } /* 143*/ /*0144*/case GuiAlarmID::ALARM_ID____AVAILABLE_9 : { result = QObject::tr("This alarm ID is available for use." ); break; } /* 144*/ /*0145*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } /* 145*/ /*0146*/case GuiAlarmID::ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Dialysate conductivity out of range." ); break; } /* 146*/