Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -refb549a694539630ba7c1d8e348f598052b85f0f -rc836b9b83aa5145367e3d3d154dd2c7190b22532 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision efb549a694539630ba7c1d8e348f598052b85f0f) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision c836b9b83aa5145367e3d3d154dd2c7190b22532) @@ -7,7 +7,7 @@ * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour - * \date (last) 30-Aug-2022 + * \date (last) 31-Aug-2022 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * @@ -61,7 +61,7 @@ /*0025*/case GuiAlarmID::ALARM_ID_DG_ACCELEROMETERS_INVALID_CAL_RECORD : { result = QObject::tr("DG accelerometer invalid calibration record." ); break; } /* 25*/ /*0026*/case GuiAlarmID::ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD : { result = QObject::tr("HD accelerometer invalid calibration record." ); break; } /* 26*/ /*0027*/case GuiAlarmID::ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED : { result = QObject::tr("HD blood leak sensor zero and self test sequence failed." ); break; } /* 27*/ -/*0028*/case GuiAlarmID::ALARM_ID_HD___AVAILABLE_4 : { result = QObject::tr("Not used." ); break; } /* 28*/ +/*0028*/case GuiAlarmID::ALARM_ID_DG_TWO_WIRE_SENSORS_FPGA_FAULT : { result = QObject::tr("DG two wire sensors FPGA fault." ); break; } /* 28*/ /*0029*/case GuiAlarmID::ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD : { result = QObject::tr("HD heparin force sensor invalid calibration record." ); break; } /* 29*/ /*0030*/case GuiAlarmID::ALARM_ID_HD_SOFTWARE_FAULT : { result = QObject::tr("HD Software fault.\nSoftware found itself in an unexpected state." ); break; } /* 30*/ /*0031*/case GuiAlarmID::ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK : { result = QObject::tr("Blood pump failed motor controller current check.\nToo high when pump should be off or out of range when pump should be running." ); break; } /* 31*/ @@ -253,7 +253,7 @@ /*0217*/case GuiAlarmID::ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE : { result = QObject::tr("HD blood prime volume check failure." ); break; } /* 217*/ /*0218*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_DETECTED : { result = QObject::tr("HD syringe detected alarm." ); break; } /* 218*/ /*0219*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED : { result = QObject::tr("HD syringe pump syringe removed alarm." ); break; } /* 219*/ -/*0220*/case GuiAlarmID::ALARM_ID___AVAILABLE_1 : { result = QObject::tr("Not used." ); break; } /* 220*/ +/*0220*/case GuiAlarmID::ALARM_ID_DG_THD_SENSORS_FPGA_FAULT : { result = QObject::tr("DG THd sensors FPGA fault." ); break; } /* 220*/ /*0221*/case GuiAlarmID::ALARM_ID_EMPTY_SALINE_BAG : { result = QObject::tr("HD Saline bag is empty." ); break; } /* 221*/ /*0222*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_HIGH : { result = QObject::tr("HD dialysate temperature too high alarm." ); break; } /* 222*/ /*0223*/case GuiAlarmID::ALARM_ID_DIALYSATE_TEMPERATURE_LOW : { result = QObject::tr("HD dialysate temperature too low alarm." ); break; } /* 223*/ @@ -329,7 +329,10 @@ /*0293*/case GuiAlarmID::ALARM_ID_HD_DISINFECT_CHEM : { result = QObject::tr("HD processor is in Disinfect Chemical mode." ); break; } /* 293*/ /*0294*/case GuiAlarmID::ALARM_ID_HD_DISINFECT_CHEM_INSTRUCTION1 : { result = QObject::tr("HD processor Disinfect Chemical mode instructions to user." ); break; } /* 294*/ /*0295*/case GuiAlarmID::ALARM_ID_UI_POST_FAILURE_CLOUDSYNC : { result = QObject::tr("UI POST CloudSync failure." ); break; } /* 295*/ -/*0296*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Total number of alarms." ); break; } /* 296*/ +/*0296*/case GuiAlarmID::ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT : { result = QObject::tr("DG TDi sensors FPGA fault." ); break; } /* 296*/ +/*0297*/case GuiAlarmID::ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT : { result = QObject::tr("DG TRo sensors FPGA fault." ); break; } /* 297*/ +/*0298*/case GuiAlarmID::ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT : { result = QObject::tr("DG baro sensor FPGA fault." ); break; } /* 298*/ +/*0299*/case GuiAlarmID::NUM_OF_ALARM_IDS : { result = QObject::tr("Total number of alarms." ); break; } /* 299*/ default: result = QObject::tr("ALARM_ID_UNDEFINED [%1]").arg(int(vAlarmID));