Index: sources/model/hd/alarm/MAlarmMapping.cpp =================================================================== diff -u -rfb4035d43b95b2a3418ff0f2b312e87df7bb3993 -rb0180b5e9ce1bcf000f451dce6fb912fe6882f37 --- sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision fb4035d43b95b2a3418ff0f2b312e87df7bb3993) +++ sources/model/hd/alarm/MAlarmMapping.cpp (.../MAlarmMapping.cpp) (revision b0180b5e9ce1bcf000f451dce6fb912fe6882f37) @@ -7,7 +7,7 @@ * * \file MAlarmMapping.cpp * \author (last) Behrouz NematiPour - * \date (last) 08-Jul-2022 + * \date (last) 11-Jul-2022 * \author (original) Behrouz NematiPour * \date (original) 03-May-2021 * @@ -139,7 +139,7 @@ /*0103*/case GuiAlarmID::ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("HD non-volatile calibration group invalid record CRC." ); break; } /* 103*/ /*0104*/case GuiAlarmID::ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS : { result = QObject::tr("Air trap level sensors reporting illegal combination of air/fluid." ); break; } /* 104*/ /*0105*/case GuiAlarmID::ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID : { result = QObject::tr("DG non-volatile system group invalid record CRC." ); break; } /* 105*/ -/*0106*/case GuiAlarmID::ALARM_ID__AVAILABLE_12 : { result = QObject::tr("Unused." ); break; } /* 106*/ +/*0106*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_FLOW_SENSOR_INVALID_CAL_RECORD : { result = QObject::tr("DG dialysate flow sensor invalid calibration record." ); break; } /* 106*/ /*0107*/case GuiAlarmID::ALARM_ID_DG_RESTARTED_FAULT : { result = QObject::tr("HD reports DG restarted fault." ); break; } /* 107*/ /*0108*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR : { result = QObject::tr("HD syringe pump ADC error." ); break; } /* 108*/ /*0109*/case GuiAlarmID::ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR : { result = QObject::tr("HD syringe pump volume check error." ); break; } /* 109*/ @@ -177,7 +177,7 @@ /*0141*/case GuiAlarmID::ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT : { result = QObject::tr("Air trap fill timeout during treatment." ); break; } /* 141*/ /*0142*/case GuiAlarmID::ALARM_ID_OCCLUSION_BLOOD_PUMP : { result = QObject::tr("Blood pump occlusion detected." ); break; } /* 142*/ /*0143*/case GuiAlarmID::ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE : { result = QObject::tr("DG dialysate temperature sensors out of range." ); break; } /* 143*/ -/*0144*/case GuiAlarmID::ALARM_ID__AVAILABLE_5 : { result = QObject::tr("Alarm ID available for use." ); break; } /* 144*/ +/*0144*/case GuiAlarmID::ALARM_ID_DG_RO_FLOW_SENSOR_INVALID_CAL_RECORD : { result = QObject::tr("DG RO flow sensor invalid calibration record." ); break; } /* 144*/ /*0145*/case GuiAlarmID::ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE : { result = QObject::tr("Concentrate conductivity after adding acid out of range alarm." ); break; } /* 145*/ /*0146*/case GuiAlarmID::ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE : { result = QObject::tr("DG RTC or timer accuracy failure." ); break; } /* 146*/ /*0147*/case GuiAlarmID::ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT : { result = QObject::tr("Wait for the DG to produce dialysate." ); break; } /* 147*/