Index: sources/view/hd/adjustment/treatment/VTreatmentAdjustmentRecirculate.h =================================================================== diff -u -r506a9e3db1a20bda1685e38c5e9041005c9a4a4f -r2ef03b2ce51b4dc507f66e9671953a8e0824bde9 --- sources/view/hd/adjustment/treatment/VTreatmentAdjustmentRecirculate.h (.../VTreatmentAdjustmentRecirculate.h) (revision 506a9e3db1a20bda1685e38c5e9041005c9a4a4f) +++ sources/view/hd/adjustment/treatment/VTreatmentAdjustmentRecirculate.h (.../VTreatmentAdjustmentRecirculate.h) (revision 2ef03b2ce51b4dc507f66e9671953a8e0824bde9) @@ -1,23 +1,23 @@ /*! * - * Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. + * Copyright (c) 2021-2024 Diality Inc. - All Rights Reserved. * \copyright * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * * \file VTreatmentAdjustmentRecirculate.h * \author (last) Behrouz NematiPour - * \date (last) 07-Feb-2021 + * \date (last) 23-Apr-2023 * \author (original) Behrouz NematiPour - * \date (original) 20-Nov-2020 + * \date (original) 11-Apr-2021 * */ #pragma once #include // Project -#include "main.h" // Doxygen : don't remove +#include "main.h" // Doxygen : do not remove #include "VAdjustmentResponseBase.h" #include "MTreatmentAdjustRecirculateResponse.h" @@ -39,12 +39,12 @@ AdjustRecirculateRequestData _data; - // coco begin validated: + // disabled coco begin validated: // The property adjustment_Triggered has to be always true // and to always trigger the change event to work as a notifier for GUI // has been manually tested that it works perfectly fine TRIGGER( bool , adjustment , 0 ) - // coco end + // disabled coco end VIEW_DEC_CLASS_ADJUSTMENT(VTreatmentAdjustmentRecirculate, AdjustRecirculateResponseData) @@ -53,11 +53,16 @@ void doAdjustment(const GuiRecirculateCommands &vRequestedState); public slots: - void doReconnect (); - void doConfirm (); - void doResume (); - void doTreatmentEnd (); + + + + void doReconnect (); // REQUESTED_USER_ACTION_TX_RECIRC_RECONNECT = 0, ///< User requests to re-connect to system (stop re-circulating, clamp arterial and venous lines) + void doConfirmReconnect (); // REQUESTED_USER_ACTION_TX_RECIRC_CONFIRM_RECONNECT = 1, ///< User confirms patient connected, lines un-shunted to return to treatment + void doResume (); // REQUESTED_USER_ACTION_TX_RECIRC_RESUME_RC = 2, ///< User requests to resume re-circulation + void doTreatmentEnd (); // REQUESTED_USER_ACTION_TX_RECIRC_END_TREATMENT = 3, ///< User requests to end treatment + void doConfirmDisconnect(); // REQUESTED_USER_ACTION_TX_RECIRC_CONFIRM_DISCONNECT = 4, ///< User confirms patient disconnected, lines shunted to begin re-circulation + signals: /*! * \brief didAdjustment