Index: sources/view/hd/data/pretreatment/VPreTreatmentStatesData.h =================================================================== diff -u -r27cc308ff5113a9386899d3c8f8b29962a8498e1 -r0f1aa395dfb46e006bdec10d0bb99f2ed27739bf --- sources/view/hd/data/pretreatment/VPreTreatmentStatesData.h (.../VPreTreatmentStatesData.h) (revision 27cc308ff5113a9386899d3c8f8b29962a8498e1) +++ sources/view/hd/data/pretreatment/VPreTreatmentStatesData.h (.../VPreTreatmentStatesData.h) (revision 0f1aa395dfb46e006bdec10d0bb99f2ed27739bf) @@ -72,14 +72,9 @@ STATE ( bool , selfTestConsumables_acidPump , false ) ///< CONSUMABLE_SELF_TESTS_ACID_PUMP_CHECK_STATE , Consumable self-tests acid concentrate pump check state STATE ( bool , selfTestConsumables_complete , false ) ///< CONSUMABLE_SELF_TESTS_COMPLETE_STATE , Consumable self-tests complete state - // Self tests with no cartridge state PROPERTY( bool , selfTestNoCartridge_start , false ) ///< NO_CART_SELF_TESTS_START_STATE , No cartridge self-tests starting state. PROPERTY( bool , selfTestNoCartridge_waitDoorClose , false ) ///< NO_CART_SELF_TESTS_WAIT_FOR_DOOR_CLOSE_STATE , Wait for door to be closed before running self-tests. - PROPERTY( bool , selfTestNoCartridge_occlusionSensors , false ) ///< NO_CART_SELF_TESTS_OCCLUSION_SENSORS_STATE , No cartridge occlusion sensors self-test state. - PROPERTY( bool , selfTestNoCartridge_bloodFlowMeters , false ) ///< NO_CART_SELF_TESTS_BLOOD_FLOW_METERS_STATE , No cartridge blood flow meter self-test state. - PROPERTY( bool , selfTestNoCartridge_dialysateFlowMeters , false ) ///< NO_CART_SELF_TESTS_DIALYSATE_FLOW_METERS_STATE , No cartridge dialysate flow meter self-test state. - PROPERTY( bool , selfTestNoCartridge_leakDetectors , false ) ///< NO_CART_SELF_TESTS_LEAK_DETECTORS_STATE , No cartridge leak detectors self-test state. - PROPERTY( bool , selfTestNoCartridge_boardTemperature , false ) ///< NO_CART_SELF_TESTS_BOARD_TEMPERATURE_STATE , No cartridge board temperature self-test state. + PROPERTY( bool , selfTestNoCartridge_pressureCheck , false ) ///< NO_CART_SELF_TESTS_PRESSURE_CHECKS_STATE , No cartridge pressure sensors self-test state PROPERTY( bool , selfTestNoCartridge_homeValves , false ) ///< NO_CART_SELF_TESTS_HOME_VALVES_STATE , No cartridge home valves state PROPERTY( bool , selfTestNoCartridge_homeSyringePump , false ) ///< NO_CART_SELF_TESTS_HOME_SYRINGE_PUMP_STATE , No cartridge home syringe pump state PROPERTY( bool , selfTestNoCartridge_pumps , false ) ///< NO_CART_SELF_TESTS_PUMPS_STATE , No cartridge self-test for blood pump, dialysate in pump, dialysate out pump state. @@ -100,6 +95,7 @@ STATE ( bool , selfTestDry_pressureSensors , false ) ///< DRY_SELF_TESTS_PRESSURE_SENSORS_STATE , Pressure sensors verify pressure readings state. STATE ( bool , selfTestDry_pressureSensorsNormal , false ) ///< DRY_SELF_TESTS_PRESSURE_SENSORS_NORMAL_STATE , Pressure sensors verify normal pressure readings state. STATE ( bool , selfTestDry_syringePump , false ) ///< DRY_SELF_TESTS_SYRINGE_PUMP_PRIME_STATE , Prime syringe pump state + STATE ( bool , selfTestDry_syringePumpOcclusionDetection, false ) ///< DRY_SELF_TESTS_SYRINGE_PUMP_OCCLUSION_DETECTION_STATE , Occlusion detection state STATE ( bool , selfTestDry_stopped , false ) ///< DRY_SELF_TESTS_STOPPED_STATE , Dry self-test stopped state. STATE ( bool , selfTestDry_complete , false ) ///< DRY_SELF_TESTS_COMPLETE_STATE , Dry self-test complete state. @@ -111,6 +107,8 @@ STATE ( bool , prime_salineCirculateBloodCircuit , false ) ///< HD_PRIME_SALINE_CIRC_BLOOD_CIRCUIT_STATE , Circulate blood circuit state STATE ( bool , prime_reservoiOneFillComplete , false ) ///< HD_PRIME_RESERVOIR_ONE_FILL_COMPLETE_STATE , Wait for reservoir 1 fill complete STATE ( bool , prime_dialysateDialyzer , false ) ///< HD_PRIME_DIALYSATE_DIALYZER_STATE , Dialysate dialyzer fluid path state + STATE ( bool , prime_salineDialyzerSetup , false ) ///< HD_PRIME_SALINE_DIALYZER_SETUP_STATE , Saline dialyzer setup state + STATE ( bool , prime_salineDialyzer , false ) ///< HD_PRIME_SALINE_DIALYZER_STATE , Saline dialyzer fluid path state STATE ( bool , prime_reservoirTwoFillComplete , false ) ///< HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE , Wait for reservoir 2 fill complete STATE ( bool , prime_dialysateBypass , false ) ///< HD_PRIME_DIALYSATE_BYPASS_STATE , Dialysate bypass fluid path state STATE ( bool , prime_wetSelfTests , false ) ///< HD_PRIME_WET_SELF_TESTS_STATE , Perform wet self-tests after priming complete