Index: AlarmDefs.h =================================================================== diff -u -r1a9c0f5ae621b5587357fb8c10afc575bfdede7d -r5eb3e158f247bac6c907db5ea1407145633c5839 --- AlarmDefs.h (.../AlarmDefs.h) (revision 1a9c0f5ae621b5587357fb8c10afc575bfdede7d) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 5eb3e158f247bac6c907db5ea1407145633c5839) @@ -46,15 +46,15 @@ ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE = 8, ///< HD accelerometer failed POST ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE = 9, ///< DG accelerometer failed POST ALARM_ID_HD_BLOOD_LEAK_SENSOR_EMBEDDED_MODE_FAILURE = 10, ///< HD blood leak sensor setting embedded mode failure. - ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP = 11, ///< HD dialysate temperature below target temperature + ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP = 11, ///< HD dialysate temperature below target temperature or below safety temp ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED = 12, ///< HD firmware image integrity POST test failed ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED = 13, ///< DG firmware image integrity POST test failed ALARM_ID_DG_INVALID_USAGE_RECORD_CRC = 14, ///< DG invalid usage record CRC - ALARM_ID_AVAILABLE_60 = 15, ///< alarm ID available + ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP = 15, ///< HD dialysate temperature above high safety. ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE = 16, ///< HD alarm audio failed POST ALARM_ID_HD_UI_POST_FAILED = 17, ///< HD UI POST failed ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_DG = 18, ///< HD didn't get ACK on message to DG that required acknowledgment - ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP = 19, ///< HD dialysate temperature above target temperature. + ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP = 19, ///< HD dialysate temperature above target temperature or above safety temp. ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD = 20, ///< DG conductivity sensors invalid calibration record ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD = 21, ///< DG drain line volume invalid calibration record ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD = 22, ///< DG reservoirs invalid calibration record @@ -82,7 +82,7 @@ ALARM_ID_UI_COMM_TIMEOUT = 44, ///< User interface communication timeout ALARM_ID_HD_COMM_TOO_MANY_BAD_CRCS = 45, ///< HD too many bad communications CRC ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_UI = 46, ///< HD didn't get ACK on message to UI that required acknowledgment - ALARM_ID_HD_UF_RATE_ERROR = 47, ///< Ultrafiltration rate is too high error during treatment + ALARM_ID_HD_UF_RATE_ERROR = 47, ///< Ultrafiltration rate is too high error during treatment ALARM_ID_UF_VOLUME_ACCURACY_ERROR = 48, ///< Ultrafiltration volume accuracy error during treatment ALARM_ID_HD_FPGA_COMM_TIMEOUT = 49, ///< HD FPGA communication down for too long ALARM_ID_DG_VALVE_CONTROL_FAILURE = 50, ///< DG FPGA not accepting commanded valve states @@ -127,7 +127,7 @@ ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW = 89, ///< DG outlet UV reactor on with no flow ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT = 90, ///< DG load cells A1/B1 FPGA fault ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE = 91, ///< HD No dialysate flow data receive in the last 3 seconds - ALARM_ID_AVAILABLE_50 = 92, ///< Alarm ID available for use + ALARM_ID_AVAILABLE_1 = 92, ///< Available for use ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE = 93, ///< DG outlet primary conductivity out of range ALARM_ID_DG_PRESSURE_OUT_OF_RANGE = 94, ///< DG pressure out of range ALARM_ID_DG_WATCHDOG_EXPIRED = 95, ///< DG watchdog expired @@ -151,7 +151,7 @@ ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE = 113, ///< DG Drain pump current out of range ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE = 114, ///< HD venous air bubble detector self-test failure ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE = 115, ///< DG temperature sensor out of range - ALARM_ID_DG___AVAILABLE_4 = 116, ///< Available for use + ALARM_ID_AVAILABLE_2 = 116, ///< Available for use ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED = 117, ///< DG CAN message not acked ALARM_ID_DG_RTC_CONFIG_ERROR = 118, ///< DG RTC config error ALARM_ID_DG_RTC_BATTERY_LOW = 119, ///< DG RTC battery low error @@ -201,7 +201,7 @@ ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM = 163, ///< HD sees primary load cell for reservoir 1 change too much too fast ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM = 164, ///< HD sees primary load cell for reservoir 2 change too much too fast ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM = 165, ///< HD in treatment rinseback operation timeout - ALARM_ID___AVAILABLE_5 = 166, ///< Available for use + ALARM_ID_AVAILABLE_3 = 166, ///< Available for use ALARM_ID_CARTRIDGE_DOOR_OPENED = 167, ///< HD cartridge door opened alarm ALARM_ID__AVAILABLE_70 = 168, ///< Available for use ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE = 169, ///< DG Dialysate flow rate out of maximum range @@ -211,7 +211,7 @@ ALARM_ID_HD_RTC_CONFIG_ERROR = 173, ///< HD RTC configuration error ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE = 174, ///< HD RTC or timer accuracy failure ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR = 175, ///< HD pump direction status error - ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_HIGH_SAFETY_RANGE = 176, ///< HD dialysate temperature out of high safety range + ALARM_ID_AVAILABLE_4 = 176, ///< HD dialysate temperature above high safety range ALARM_ID_DG_SOFTWARE_FAULT = 177, ///< DG software fault. Software found itself in an unexpected state ALARM_ID_HD_COMM_TIMEOUT = 178, ///< HD communication timeout ALARM_ID_DG_FPGA_COMM_TIMEOUT = 179, ///< DG FPGA communication down for too long @@ -228,7 +228,7 @@ ALARM_ID_DRAIN_PUMP_OFF_FAULT = 190, ///< DG drain pump off fault ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE = 191, ///< DG flow rate out of upper range ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE = 192, ///< DG flow rate out of lower range - ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_LOW_SAFETY_RANGE = 193, ///< HD dialysate temperature out of low safety range. + ALARM_ID_AVAILABLE_5 = 193, ///< Available for use ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE = 194, ///< DG RO pump duty cycle out of range ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE = 195, ///< DG RO pump pressure out of range ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT = 196, ///< DG CPi/CPo sensors FPGA fault @@ -238,7 +238,7 @@ ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE = 200, ///< DG thermistors/sensors temperature out of range ALARM_ID_PRE_TREATMENT_WET_FLOW_TEST_FAILURE = 201, ///< HD pre-treatment mode wet self-test lc vs FMD failure ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE = 202, ///< HD pre-treatment mode dry pressure normal self-test failure - ALARM_ID___AVAILABLE_3 = 203, ///< Available for use + ALARM_ID_AVAILABLE_6 = 203, ///< Available for use ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE = 204, ///< RO rejection ratio out of range ALARM_ID_CONDUCTIVITY_SENSOR_FAULT = 205, ///< Conductivity sensor fault ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME = 206, ///< DG dialysate fill runs out of time @@ -282,7 +282,7 @@ ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE = 244, ///< DG cleaning mode temperature sensors difference out of range ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT = 245, ///< DG heat disinfect target temperature time out (could not reach to temperature) ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE = 246, ///< DG cleaning mode conductivity sensors out of range - ALARM_ID_AVAILABLE_62 = 247, ///< Alarm Id available + ALARM_ID_AVAILABLE_7 = 247, ///< Alarm Id available ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE = 248, ///< DG chemical disinfect could not reach to target temperature out of range ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE = 249, ///< DG chemical disinfect target conductivity out of range ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID = 250, ///< DG chemical disinfect insert acid and remove the concentrate cap @@ -292,8 +292,8 @@ ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC = 254, ///< DG invalid service record ALARM_ID_HD_UI_COMPATIBILITY_ERROR = 255, ///< HD and UI software builds are not compatible ALARM_ID_HD_DISINFECT_CHEM_FLUSH = 256, ///< HD processor is in Disinfect Chemical Flush mode - ALARM_ID_AVAILABLE_51 = 257, ///< Alarm ID available for use - ALARM_ID_HD___AVAILABLE_1 = 258, ///< ***Available for use*** + ALARM_ID_AVAILABLE_8 = 257, ///< Alarm ID available for use + ALARM_ID_AVAILABLE_9 = 258, ///< Alarm Id available ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE = 259, ///< HD temperatures out of range ALARM_ID_UI_POST_FAILURE_SHASUM = 260, ///< UI POST Application Integrity (Sha256Sum) failure ALARM_ID_UI_POST_FAILURE_CANBUS = 261, ///< UI POST CANBus failure @@ -308,8 +308,8 @@ ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED = 270, ///< HD POST Safety Shutdown failure ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED = 271, ///< DG POST Safety Shutdown failure ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE = 272, ///< HD Fan RPM out of range - ALARM_ID___AVAILABLE_7 = 273, ///< Available for use - ALARM_ID___AVAILABLE_8 = 274, ///< Available for use + ALARM_ID_AVAILABLE_10 = 273, ///< Available for use + ALARM_ID_AVAILABLE_11 = 274, ///< Available for use ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE = 275, ///< HD arterial pressure sensor is reading out of range ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE = 276, ///< HD venous pressure sensor is reading out of range ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE = 277, ///< HD BP occlusion sensor is reading out of range @@ -320,7 +320,7 @@ ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME = 282, ///< Bicarbonate concentration bottle low volume alarm ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE = 283, ///< DG load cells weight out of range ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE = 284, ///< DG load cells primary/back up drift out of range - ALARM_ID___AVAILABLE_6 = 285, ///< Available for use + ALARM_ID_AVAILABLE_12 = 285, ///< Available for use ALARM_ID_DG_CONCENTRATE_CAP_NOT_IN_PROPER_POSITION = 286, ///< DG concentrate cap not in proper position ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE = 287, ///< HD processor clock speed checks against FPGA clock failure ALARM_ID_HD_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE = 288, ///< HD load cells primary/back up drift out of range @@ -329,14 +329,14 @@ ALARM_ID_HD_DISINFECT_FLUSH = 291, ///< HD processor is in Disinfect Flush mode ALARM_ID_HD_DISINFECT_HEAT = 292, ///< HD processor is in Disinfect Heat mode ALARM_ID_HD_DISINFECT_CHEM = 293, ///< HD processor is in Disinfect Chemical mode - ALARM_ID_AVAILABLE_63 = 294, ///< Available for use + ALARM_ID_AVAILABLE_13 = 294, ///< Available for use ALARM_ID_UI_POST_FAILURE_CLOUDSYNC = 295, ///< UI POST CloudSync failure ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT = 296, ///< DG TDi sensors FPGA fault ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT = 297, ///< DG TRo sensors FPGA fault ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT = 298, ///< DG baro sensor FPGA fault ALARM_ID_DG_INVALID_SERIAL_NUMBER = 299, ///< DG invalid serial number ALARM_ID_HD_INVALID_SERIAL_NUMBER = 300, ///< HD invalid serial number - ALARM_ID_AVAILABLE_61 = 301, ///< Alarm ID available + ALARM_ID_AVAILABLE_14 = 301, ///< Alarm ID available ALARM_ID_DG_CPU_RAM_ERROR = 302, ///< DG processor RAM error ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT = 303, ///< DG drain pump direction FPGA fault ALARM_ID_HD_INVALID_USAGE_RECORD_CRC = 304, ///< HD invalid usage record @@ -487,7 +487,7 @@ { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_USAGE_RECORD_CRC }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_60 }, + { ALARM_PRIORITY_HIGH, 401, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILED }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_DG }, @@ -567,7 +567,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_50 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_1 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_WATCHDOG_EXPIRED }, @@ -592,7 +592,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG___AVAILABLE_4 }, + { ALARM_PRIORITY_HIGH, 999, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_2 }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RTC_CONFIG_ERROR }, { ALARM_PRIORITY_LOW, 851, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_RTC_BATTERY_LOW }, @@ -644,9 +644,9 @@ { ALARM_PRIORITY_MEDIUM, 442, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM }, { ALARM_PRIORITY_MEDIUM, 442, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM }, { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID___AVAILABLE_5 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_3 }, { ALARM_PRIORITY_HIGH, 209, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_CARTRIDGE_DOOR_OPENED }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID__AVAILABLE_70 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID__AVAILABLE_70 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION }, @@ -655,7 +655,7 @@ { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR }, - { ALARM_PRIORITY_MEDIUM, 401, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_HIGH_SAFETY_RANGE }, + { ALARM_PRIORITY_MEDIUM, 999, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_4 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_SOFTWARE_FAULT }, { ALARM_PRIORITY_HIGH, 0, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_COMM_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_COMM_TIMEOUT }, @@ -672,7 +672,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DRAIN_PUMP_OFF_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE }, - { ALARM_PRIORITY_MEDIUM, 400, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_LOW_SAFETY_RANGE }, + { ALARM_PRIORITY_MEDIUM, 999, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_5 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT }, @@ -683,7 +683,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_FLOW_TEST_FAILURE }, { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID___AVAILABLE_3 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_6 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, @@ -728,7 +728,7 @@ { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_62 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_7 }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, @@ -739,8 +739,8 @@ { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_COMPATIBILITY_ERROR }, { ALARM_PRIORITY_LOW, 843, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DISINFECT_CHEM_FLUSH }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_51 }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD___AVAILABLE_1 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_8 }, + { ALARM_PRIORITY_HIGH, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_9 }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SHASUM }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CANBUS }, @@ -755,8 +755,8 @@ { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED }, { ALARM_PRIORITY_LOW, 850, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID___AVAILABLE_7 }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID___AVAILABLE_8 }, + { ALARM_PRIORITY_HIGH, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_10 }, + { ALARM_PRIORITY_HIGH, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_11 }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE }, @@ -768,7 +768,7 @@ { ALARM_PRIORITY_MEDIUM, 413, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID___AVAILABLE_6 }, + { ALARM_PRIORITY_MEDIUM, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_AVAILABLE_12 }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONCENTRATE_CAP_NOT_IN_PROPER_POSITION }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE }, { ALARM_PRIORITY_HIGH, 110, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE }, @@ -777,15 +777,15 @@ { ALARM_PRIORITY_LOW, 840, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DISINFECT_FLUSH }, { ALARM_PRIORITY_LOW, 841, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DISINFECT_HEAT }, { ALARM_PRIORITY_LOW, 842, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DISINFECT_CHEM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_63 }, + { ALARM_PRIORITY_MEDIUM, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_13 }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CLOUDSYNC }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_SERIAL_NUMBER }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SERIAL_NUMBER }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_61 }, + { ALARM_PRIORITY_HIGH, 999, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_14 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPU_RAM_ERROR }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_USAGE_RECORD_CRC }, @@ -819,7 +819,6 @@ { 1, ALARM_ID_UI_COMM_POST_FAILED }, { 1, ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE }, { 1, ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED }, - { 1, ALARM_ID_AVAILABLE_60 }, { 1, ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE }, { 1, ALARM_ID_HD_UI_POST_FAILED }, { 1, ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD }, @@ -836,7 +835,6 @@ { 1, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, { 1, ALARM_ID_UI_POST_FAILURE_RTC }, { 1, ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD }, - { 1, ALARM_ID___AVAILABLE_3 }, { 1, ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE }, { 1, ALARM_ID_HD_INVALID_USAGE_RECORD_CRC }, { 1, ALARM_ID_HD_SET_RTC_YEAR_INVALID }, @@ -868,18 +866,10 @@ { 2, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD }, { 2, ALARM_ID_DG_INVALID_SERIAL_NUMBER }, { 2, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD }, - { 3, ALARM_ID_AVAILABLE_61 }, { 3, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, - { 3, ALARM_ID_AVAILABLE_51 }, { 3, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, - { 3, ALARM_ID_DG___AVAILABLE_4 }, - { 3, ALARM_ID_AVAILABLE_50 }, - { 3, ALARM_ID_HD___AVAILABLE_1 }, - { 3, ALARM_ID___AVAILABLE_7 }, - { 3, ALARM_ID___AVAILABLE_8 }, - { 3, ALARM_ID_AVAILABLE_62 }, { 3, ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED }, { 10, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED }, { 10, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK }, @@ -1046,10 +1036,9 @@ { 291, ALARM_ID_END_TREATMENT_TIMEOUT_ALARM }, { 292, ALARM_ID_PRIME_COMPLETED_HIGH }, { 300, ALARM_ID_TREATMENT_STOPPED_BY_USER }, - { 400, ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_LOW_SAFETY_RANGE }, { 400, ALARM_ID_HD_DIAL_IN_FLOW_CHECK_FAILURE }, { 401, ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP }, - { 401, ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_HIGH_SAFETY_RANGE }, + { 401, ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP }, { 402, ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP }, { 410, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 411, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, @@ -1090,8 +1079,6 @@ { 604, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_LOW }, { 605, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_HIGH }, { 606, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW }, - { 799, ALARM_ID___AVAILABLE_5 }, - { 799, ALARM_ID__AVAILABLE_70 }, { 799, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION }, { 799, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 799, ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT }, @@ -1115,8 +1102,6 @@ { 899, ALARM_ID___AVAILABLE_10 }, { 899, ALARM_ID___AVAILABLE_11 }, { 899, ALARM_ID_HD_SYRINGE_DETECTED }, - { 899, ALARM_ID___AVAILABLE_6 }, - { 899, ALARM_ID_AVAILABLE_63 }, { 904, ALARM_ID_END_OF_TREATMENT_WARNING }, { 905, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY }, { 909, ALARM_ID_PRIME_OUT_OF_TIME }, @@ -1132,6 +1117,21 @@ { 999, ALARM_ID_NO_CARTRIDGE_LOADED }, { 999, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, { 999, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { 999, ALARM_ID_AVAILABLE_1 }, + { 999, ALARM_ID_AVAILABLE_2 }, + { 999, ALARM_ID_AVAILABLE_3 }, + { 999, ALARM_ID_AVAILABLE_4 }, + { 999, ALARM_ID_AVAILABLE_5 }, + { 999, ALARM_ID_AVAILABLE_6 }, + { 999, ALARM_ID_AVAILABLE_7 }, + { 999, ALARM_ID_AVAILABLE_8 }, + { 999, ALARM_ID_AVAILABLE_9 }, + { 999, ALARM_ID_AVAILABLE_10 }, + { 999, ALARM_ID_AVAILABLE_11 }, + { 999, ALARM_ID_AVAILABLE_12 }, + { 999, ALARM_ID_AVAILABLE_13 }, + { 999, ALARM_ID_AVAILABLE_14 }, + { 999, ALARM_ID__AVAILABLE_70 }, { 999, ALARM_ID_NO_ALARM }, }; @@ -1168,7 +1168,7 @@ { 12 , ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED , "HD | Self Test Error | Call service to schedule a repair. | HD firmware image integrity POST test failed | If the calculated CRC of the HD image does not match the expected CRC. | "}, { 13 , ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED , "DG | Self Test Error | Call service to schedule a repair. | DG firmware image integrity POST test failed | If the calculated CRC of the DG firmware image does not matched the expected CRC | "}, { 14 , ALARM_ID_DG_INVALID_USAGE_RECORD_CRC , "DG | Self Test Error | Call service to schedule a repair. | DG non-volatile usage information group invalid record CRC | If the DG usage information record's CRC does not match the calculated CRC in POST. | "}, - { 15 , ALARM_ID_AVAILABLE_60 , "NA | Not Used | N/A. | | | "}, + { 15 , ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP , "HD | Dialysate Temperature Error | Call service to schedule a repair. | Dialysate temperature is above safety limit | If the dialysate temperature is above the safety temperature for a certain period of time. | "}, { 16 , ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE , "HD | Self Test Error | Call service to schedule a repair. | HD alarm audio failed POST | If alarm audio current is NOT sufficiently high for at more than 1 second indicating alarm tone is being output | "}, { 17 , ALARM_ID_HD_UI_POST_FAILED , "HD | Self Test Error | Call service to schedule a repair. | HD UI POST failed | If User Interface has not sent POST results within 2 seconds. | "}, { 18 , ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_DG , "HD | Communication Error | Call service to schedule a repair. | HD did not get ACK on message to DG that required acknowledgement | If no retries left in the pending acknowlegement. | "}, @@ -1245,7 +1245,7 @@ { 89 , ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | UV Reactor Error | Call service to schedule a repair. | DG outlet UV reactor is on while there is no flow | If the outlet UV reactor is on while the RO flow is less than 200 mL/min. | "}, { 90 , ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG load cells A1/B1 FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, { 91 , ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE , "HD | Dialysate Measurement Error | Call service to schedule a repair. | HD No dialysate flow data receive in the last 3 seconds | If not receiving new dialysate flow readings in expected interval (3 seconds) | "}, - { 92 , ALARM_ID_AVAILABLE_50 , "NA | N/A | N/A | N/A | N/A | "}, + { 92 , ALARM_ID_AVAILABLE_1 , "N/A | N/A | N/A | N/A | N/A | "}, { 93 , ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Sensors Error | Call service to schedule a repair. | DG outlet primary conductivity sensor out of range | If the outlet primary conductivity sensor, CPo is greater than 30 uS/cm for a certain period of time. | "}, { 94 , ALARM_ID_DG_PRESSURE_OUT_OF_RANGE , "DG | Pressure Sensors Error | Call service to schedule a repair. | DG pressure sensor out of range | If either of the pressure sensors is < 0 psia or > 200 psia or the barometric pressure sensor is > 10.1 psi or < 15.4 psi. | "}, { 95 , ALARM_ID_DG_WATCHDOG_EXPIRED , "DG | Watchdog Error | Call service to schedule a repair. | DG watchdog expired | If the watchdog signal is low while not in POST. | "}, @@ -1269,7 +1269,7 @@ { 113 , ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE , "DG | Drain Pump Error | Call service to schedule a repair. | DG drain pump current out of range | If the DG drain pump current > 2.2 A when it is in open loop or if the current > 0.1 A when it is off. | "}, { 114 , ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE , "HD | Air Bubble Detector Error | Call service to schedule a repair. | HD venous air bubble detector self-test failure | If the venous air bubble self test did not detect bubble for more than 500 msec. | "}, { 115 , ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE , "DG | Dialysate Temperature Error | Call service to schedule a repair. | DG temperature sensor out of range | If the measured temperature < 0 C or > 80 C for the non-fluid inline sensors and > 120 C for the fluid sensors. | "}, - { 116 , ALARM_ID_DG___AVAILABLE_4 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 116 , ALARM_ID_AVAILABLE_2 , "NA | Not used | Call service to schedule a repair. | DG temperature sensor ADC out of range | If the ADC value of the sensor is not out of range. | "}, { 117 , ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED , "DG | Machine Error | Call service to schedule a repair. | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, { 118 , ALARM_ID_DG_RTC_CONFIG_ERROR , "DG | RTC Error | Call service to schedule a repair. | DG RTC configuration error | If the RTC configuration registers report an error. | "}, { 119 , ALARM_ID_DG_RTC_BATTERY_LOW , "DG | RTC Error | Call service to schedule a repair. | DG RTC battery low | If the RTC battery bit report a low alarm. | "}, @@ -1320,7 +1320,7 @@ { 163 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM , "HD | Ultrafiltration Measurement Error | Ultrafiltration error. | HD sees primary load cell for reservoir 1 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, { 164 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM , "HD | Ultrafiltration Measurement Error | Ultrafiltration error. | HD sees primary load cell for reservoir 2 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, { 165 , ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM , "HD | Rinseback Timeout | Maximum Rinseback time exceeded. Rinseback must end. | HD in treatment rinseback operation timeout | If the maximum time inrinseback operation has been exceeded. | "}, - { 166 , ALARM_ID___AVAILABLE_5 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 166 , ALARM_ID_AVAILABLE_3 , "NA | Not used | Call service to schedule a repair. | HD in treatment re-circ sub-mode for too long | If the maximum time in recirculate sub-mode has been exceeded. | "}, { 167 , ALARM_ID_CARTRIDGE_DOOR_OPENED , "HD | Door Open | Hemodialysis Delivery device door open.\n - Close open HD door\n - Press RESUME button | HD cartridge door opened alarm | If the cartridge door is opened as reported by the FPGA. | "}, { 168 , ALARM_ID__AVAILABLE_70 , "DG | Dialysate Recirculation Error | Dialysate recirculation error. | HD active reservoir depletion timeout. | If the active reservoir's depletion time has elapsed. | "}, { 169 , ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE , "DG | Dialysate Generation Error | Call service to schedule a repair. | Dialysate flow rate out of range | If the dialysate flow rate > 2.00 L/min. | "}, @@ -1330,7 +1330,7 @@ { 173 , ALARM_ID_HD_RTC_CONFIG_ERROR , "HD | RTC Error | Call service to schedule a repair. | HD RTC configuration error | If the RTC configuration registers report an error. | "}, { 174 , ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE , "HD | Self-Test Error | Call service to schedule a repair. | HD RTC vs. Timer accuracy error | If RTC and timer are not aligned on 1 second elapsed time. | "}, { 175 , ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR , "HD | Blood Pump Error | Blood pump failure. \n- Check the pump rotor for secure connection. | HD pump direction status error | If the set pump direction does not agree with the hall sensor direction. | "}, - { 176 , ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_HIGH_SAFETY_RANGE , "HD | Dialysate Temperature Error | Call service to schedule a repair. | Dialysate temperature is out of high safety range | If the dialysate temperature is > 46 C for a certain period of time. | "}, + { 176 , ALARM_ID_AVAILABLE_4 , "HD | Dialysate Temperature Error | Call service to schedule a repair. | Dialysate temperature is out of high safety range | If the dialysate temperature is > 46 C for a certain period of time. | "}, { 177 , ALARM_ID_DG_SOFTWARE_FAULT , "DG | Machine Error | Call service to schedule a repair. | DG software fault. Software found itself in an unexpected state | If the specific software faults listed in alarm management SW faults has been detected | "}, { 178 , ALARM_ID_HD_COMM_TIMEOUT , "DG | HD Machine Alarm: UI-Proc Comm | Call service to schedule a repair. | HD communication timeout | If the HD stops communicating with the UI. | "}, { 179 , ALARM_ID_DG_FPGA_COMM_TIMEOUT , "DG | Communication Failure | Call service to schedule a repair. | DG FPGA communication down for too long | If retries for commands exceeds limit or FPGA reports comm error. | "}, @@ -1347,7 +1347,7 @@ { 190 , ALARM_ID_DRAIN_PUMP_OFF_FAULT , "DG | Drain Pump Error | Call service to schedule a repair. | DG drain pump off fault | If the pump is in off state and the RPM is greater than the minimum RPM of 300.0 RPM. | "}, { 191 , ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE , "DG | RO Flow Error | Call service to schedule a repair. | DG flow rate out of upper range | If the RO flow rate > 10% from the target flow rate. | "}, { 192 , ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE , "DG | RO Flow Error | Call service to schedule a repair. | DG flow rate out of lower range | If the RO flow rate < 10% from the target flow rate. | "}, - { 193 , ALARM_ID_HD_DIALYSATE_TEMP_OUT_OF_LOW_SAFETY_RANGE , "HD | Dialysate Temperature Error | Call service to schedule a repair. | Dialysate temperature is out of low safety range | If the dialysate temepertaure is < 42 C for a certain period of time. | "}, + { 193 , ALARM_ID_AVAILABLE_5 , "HD | Dialysate Temperature Error | Call service to schedule a repair. | Dialysate temperature is out of low safety range | If the dialysate temepertaure is > 42 C for a certain period of time. | "}, { 194 , ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE , "DG | RO Pump Error | Call service to schedule a repair. | DG RO pump duty cycle out of range | If the DG RO pump duty cycle is out of range by 5% of the target duty cycle for a certain period of time. | "}, { 195 , ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE , "DG | RO Pump Error | Call service to schedule a repair. | DG RO pump pressure out of range | If the DG RO pump pressure > 135 psi for a certain period of time. | "}, { 196 , ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG CPi/CPo conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "}, @@ -1357,7 +1357,7 @@ { 200 , ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE , "DG | Thermistors Error | Call service to schedule a repair. | DG thermistor or temperature sensor out of range | If thermistor > 80.0 C or < 0.0 C. | "}, { 201 , ALARM_ID_PRE_TREATMENT_WET_FLOW_TEST_FAILURE , "HD | Pre-Treatment Error | Call service to schedule a repair. | HD pre-treatment wet flow test failure | If the pre-treatment wet flow test has failed. | "}, { 202 , ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE , "HD | Pre-Treatment Error | Call service to schedule a repair. | HD pre-treatment dry pressure normal test failure | If the pre-treatment dry pressure normla test failed. | "}, - { 203 , ALARM_ID___AVAILABLE_3 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 203 , ALARM_ID_AVAILABLE_6 , "NA | Not used | Call service to schedule a repair. | DG pressure sensors fault | If pressure sensor ADC reading = 0 or inlet pressure ADC reading > 4095 (12-bit full scale ). | "}, { 204 , ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE , "DG | RO Rejection Error | Call service to schedule a repair. | RO rejection ratio out of range | If RO rejection ratio > 0.1 and outlet water conductivity > 15.0 uS/cm. | "}, { 205 , ALARM_ID_CONDUCTIVITY_SENSOR_FAULT , "DG | Conductivity Sensors Error | Call service to schedule a repair. | Conductivity sensor fault | If conductivity sensor error count reported by the FPGA > 0 for more than 5 times. | "}, { 206 , ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME , "DG | Dialysate Production Error | Call service to schedule a repair. | DG dialysate fill runs out of time | If DG dialysate fill > 5 minutes. | "}, @@ -1402,7 +1402,7 @@ { 244 , ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE , "DG | Cleaning Mode Error | Call service to schedule a repair. | DG temperature sensors difference out of range | If any of the temperature sensors are out of the average of the sensors by more than 3 C. | "}, { 245 , ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT , "DG | Heat Disinfection Error | Call service to schedule a repair. | DG heat disinfect target temperature time out (could not reach to temperature) | If heating up to minimum temperature for heat disinfect failed after 4 hours. | "}, { 246 , ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect inlet conducitivty out of range | If CPo and CD2 conductivity values are above 100 uS/cm. | "}, - { 247 , ALARM_ID_AVAILABLE_62 , "NA | Not Used | Call service to schedule a repair. | | | "}, + { 247 , ALARM_ID_AVAILABLE_7 , "N/A | Not Used | Call service to schedule a repair. | DG heat disinfect active cool time out | If THd > 44 C after 90 minutes of cooling. | "}, { 248 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect out of target temperature | If TPo > 50 C after 1 second. | "}, { 249 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect out of target conductivity | If CD2 < 150 uS/cm or CD2 > 650 uS/cm after 10 seconds. | "}, // Num Alarm ID Device Display Title Instructions Description Trigger Condition @@ -1413,8 +1413,8 @@ { 254 , ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC , "DG | Machine Error | Call service to schedule a repair. | DG invalid service record | If the calculated CRC of the DG service record image does not match the expected CRC. | "}, { 255 , ALARM_ID_HD_UI_COMPATIBILITY_ERROR , "HD | Machine Error | Call service to schedule a repair. | HD and UI software builds are not compatible | If the compatibility revision field of the UI is not equal to SW_COMPATIBILITY_REV. | "}, { 256 , ALARM_ID_HD_DISINFECT_CHEM_FLUSH , "HD | Cleaning Modes Start Alarm | No Instructions | DG chemical disinfect flush started | If DG chemical disinfect flush successfully started from the UI. | "}, - { 257 , ALARM_ID_AVAILABLE_51 , "NA | Not Used | Call service to schedule a repair. | | | "}, - { 258 , ALARM_ID_HD___AVAILABLE_1 , "NA | NoT Used | Call service to schedule a repair. | | | "}, + { 257 , ALARM_ID_AVAILABLE_8 , "N/A | N/A | N/A | N/A | N/A | "}, + { 258 , ALARM_ID_AVAILABLE_9 , "NA | NOT USED | Call service to schedule a repair. | NOT USED | NOT USED | "}, { 259 , ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE , "HD | Temperature Sensors Error | Call service to schedule a repair. | HD temperatures out of range | If thermistor reports temperature > 80.0 C or < 0.0 C for a certain period of time. | "}, { 260 , ALARM_ID_UI_POST_FAILURE_SHASUM , "UI | Machine Error | Call service to schedule a repair. | UI POST Application Integrity (Sha256Sum) failure | If the UI POST reports a shasum faillure. | "}, { 261 , ALARM_ID_UI_POST_FAILURE_CANBUS , "UI | Machine Error | Call service to schedule a repair. | UI POST CANBus failure | If the UI POST reports a can bus failure. | "}, @@ -1429,8 +1429,8 @@ { 270 , ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED , "HD | Self Test Error | Call service to schedule a repair. | HD POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, { 271 , ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED , "DG | Self Test Error | Call service to schedule a repair. | DG POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, { 272 , ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE , "HD | Fans Error | Fan failure.\n- Check that the fans inlets are not blocked or obstructed. | HD Fan RPM out of range | If the fan RPM is out of Min/Max range. | "}, - { 273 , ALARM_ID___AVAILABLE_7 , "NA | Not used | Call service to schedule a repair. | | | "}, - { 274 , ALARM_ID___AVAILABLE_8 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 273 , ALARM_ID_AVAILABLE_10 , "NA | Not used | Call service to schedule a repair. | HD measured blood pump flow rate is out of range | If the blood pump flow rate is > 1320.0 mL/min or < 1320.0 mL/min. | "}, + { 274 , ALARM_ID_AVAILABLE_11 , "NA | Not used | Call service to schedule a repair. | HD measured dialysate inlet pump flow rate is out of range | If the DPi pump flow rate is > 1320.0 mL/min or < 1320.0 mL/min. | "}, { 275 , ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE , "HD | Arterial Pressure Error | Call service to schedule a repair. | HD arterial pressure sensor is reading out of range | If the arterial pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, { 276 , ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE , "HD | Venous Pressure Error | Call service to schedule a repair. | HD venous pressure sensor is reading out of range | If the venous pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, { 277 , ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE , "HD | Occlusion Sensor Error | Call service to schedule a repair. | HD BP occlusion sensor is reading out of range | If the blood pump occlusion count is < 2000. | "}, @@ -1441,7 +1441,7 @@ { 282 , ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME , "DG | Bicarbonate Concentrate Volume Low | Bicarbonate concentrate low.\n- Replace bicarbonate concentrate bottle. | DG Bicarbonate concentration bottle low volume alarm | If the bicarbonate concentration bottle volume > 3680 (3780 - 100). | "}, { 283 , ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE , "DG | Load Cells Error | Call service to schedule a repair. | DG load cells weight out of range | If the weight of the DG load cells > 4500.0 g or < 0.0 g. | "}, { 284 , ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "DG | Load Cells Error | Call service to schedule a repair. | DG load cells primary/back up drift out of range | If redundant load cells deviate by more than 60g after tare for 5 seconds. | "}, - { 285 , ALARM_ID___AVAILABLE_6 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 285 , ALARM_ID_AVAILABLE_12 , "NA | Not used | Call service to schedule a repair. | HD treatment recirculate timeout warning | If the maximum time in recirculate sub-mode has been exceeded. | "}, { 286 , ALARM_ID_DG_CONCENTRATE_CAP_NOT_IN_PROPER_POSITION , "NA | Not used | Call service to schedule a repair. | HD treatment rinseback complete timeout warning | If the rise back time counter checks have failed when full blood volume has been delivered back to the patient. | "}, { 287 , ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE , "HD | Machine Error | Call service to schedule a repair. | HD processor clock speed checks against FPGA clock failure | If during initialization mode, the difference between the processor clock speed and the FPGA clock speed > 1. | "}, { 288 , ALARM_ID_HD_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "HD | Load Cells Error | Call service to schedule a repair. | HD load cell inconsistency | If redundant load cells deviate from start to end of a reservoir use during treatment by more than 10g. | "}, @@ -1450,20 +1450,20 @@ { 291 , ALARM_ID_HD_DISINFECT_FLUSH , "HD | Cleaning Modes Start Alarm | No Instructions | DG flush started | If DG flush successfully started from the UI. | "}, { 292 , ALARM_ID_HD_DISINFECT_HEAT , "HD | Cleaning Modes Start Alarm | No Instructions | DG heat disinfect started | If DG heat disinfect successfully started from the UI. | "}, { 293 , ALARM_ID_HD_DISINFECT_CHEM , "HD | Cleaning Modes Start Alarm | No Instructions | DG chemical disinfect started | If DG chemical disinfect successfully started from the UI. | "}, - { 294 , ALARM_ID_AVAILABLE_63 , "NA | Not Used | Call service to schedule a repair. | | | "}, + { 294 , ALARM_ID_AVAILABLE_13 , "N/A | Not Used | No Instructions | DG chemical disinfect instruction 1 | If DG chemical disinfect instruction has been called. | "}, // Num Alarm ID Device Display Title Instructions Description Trigger Condition { 295 , ALARM_ID_UI_POST_FAILURE_CLOUDSYNC , "UI | Machine Error | Call service to schedule a repair. | UI cloud sync POST failure | If the UI POST reports cloud sync failure. | "}, { 296 , ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG TDi sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, { 297 , ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG TRo sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, { 298 , ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG barometric sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, { 299 , ALARM_ID_DG_INVALID_SERIAL_NUMBER , "DG | Self Test Error | Call service to schedule a repair. | DG invalid serial number | If the DG serial number is empty and does not have any characters. | "}, { 300 , ALARM_ID_HD_INVALID_SERIAL_NUMBER , "HD | Self Test Error | Call service to schedule a repair. | HD invalid serial number | If the HD serial number is empty and does not have any characters. | "}, - { 301 , ALARM_ID_AVAILABLE_61 , "NA | Not Used | Call service to schedule a repair. | | | "}, + { 301 , ALARM_ID_AVAILABLE_14 , "N/A | Not Used | Call service to schedule a repair. | DG primary heater power line voltage out of range | If the DG primary heater power line voltage is off from 24V by 10%. | "}, { 302 , ALARM_ID_DG_CPU_RAM_ERROR , "DG | Processor RAM error | Call service to schedule a repair. | DG_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, { 303 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT , "DG | FPGA Error | Call service to schedule a repair. | DG drain pump direction FPGA fault | If the FPGA indicates an error for a certain period of time. | "}, { 304 , ALARM_ID_HD_INVALID_USAGE_RECORD_CRC , "HD | Self-Test Error | Call service to schedule a repair. | HD invalid usage reocord | If the CRC of the HD usage record does not match the calculated CRC. | "}, { 305 , ALARM_ID_HD_CPU_RAM_ERROR , "HD | Processor RAM error | Call service to schedule a repair. | HD_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 306 , ALARM_ID_DG_CD1_CD2_CHECK_FAULT , "NA | Available | Available | | If the air trap sensor reports upper level while HD is in treatment mode for a certain period of time. | "}, + { 306 , ALARM_ID_DG_CD1_CD2_CHECK_FAULT , "NA | Available | Available | HD air trap overfill fault | If the air trap sensor reports upper level while HD is in treatment mode for a certain period of time. | "}, { 307 , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT , "HD | HD AC power loss | HD power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until power returns. | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, { 308 , ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR , "DG | Conductivity Sensors Error | Call service to schedule a repair. | DG CPi conductivity sensor transmits invalid characters | If the CPi conductivity sensor transmits invalid characters for a certain period of time. | "}, { 309 , ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR , "DG | Conductivity Sensors Error | Call service to schedule a repair. | DG CPo conductivity sensor transmits invalid characters | If the CPo conductivity sensor transmits invalid characters for a certain period of time. | "},