Index: AlarmDefs.h =================================================================== diff -u -r71c261a9da6176c7380623526b27dfd40cbba57b -r3797cd1cf21e82b7c2c68e910b418326d5ce1668 --- AlarmDefs.h (.../AlarmDefs.h) (revision 71c261a9da6176c7380623526b27dfd40cbba57b) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 3797cd1cf21e82b7c2c68e910b418326d5ce1668) @@ -353,7 +353,7 @@ ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW = 315, ///< DG cleaning mode inlet water pressure too low. ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT = 316, ///< DG acid concentrate pump park fault. ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT = 317, ///< DG bicarb concentrate pump part fault. - ALARM_ID_HD_AIR_PUMP_TIMEOUT = 318, ///< HD Air Pump timeout alarm + ALARM_ID_AVAILABLE_2 = 318, ///< Alarm available for use ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE = 319, ///< DG chemical disinfect flush flush sample. ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT = 320, ///< DG chemical disinfect flush sample timeout. ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY = 321, ///< DG outlet UV reactor not healthy @@ -808,7 +808,7 @@ { ALARM_PRIORITY_MEDIUM, 606, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT }, - { ALARM_PRIORITY_HIGH, 10, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AIR_PUMP_TIMEOUT }, + { ALARM_PRIORITY_LOW, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_2 }, { ALARM_PRIORITY_LOW, 752, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE }, { ALARM_PRIORITY_LOW, 752, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY }, @@ -932,7 +932,6 @@ { 10, ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR }, { 10, ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR }, { 10, ALARM_ID_HD_CPU_RAM_ERROR }, - { 10, ALARM_ID_HD_AIR_PUMP_TIMEOUT }, { 10, ALARM_ID_HD_VENOUS_SENSOR_FPGA_FAULT }, { 10, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, { 10, ALARM_ID_HD_WATCHDOG_EXPIRED }, @@ -1134,6 +1133,7 @@ { 851, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, { 852, ALARM_ID_HD_AC_POWER_LOST }, { 999, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, + { 999, ALARM_ID_AVAILABLE_2 }, { 999, ALARM_ID_AVAILABLE_5 }, { 999, ALARM_ID_AVAILABLE_7 }, { 999, ALARM_ID_AVAILABLE_10 }, @@ -1482,7 +1482,7 @@ { 315 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW , "DG | Disinfection: Water Pressure Low | Incoming water pressure is too low. \n- Disinfection has been terminated.\n- Check incoming water pressure\n before initiating disinfection again. | Cleaning: Inlet Water Press Low | DG cleaning mode inlet water pressure too low | If inlet water pressure is < 14 psig. | "}, { 316 , ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Acid CP Pump Park | Acid concentrate pump did not park successfully | If the park took more than 1 second. | "}, { 317 , ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Bicarb CP Pump Park | Bicarb concentrate pump did not park successfully | If the park took more than 1 second. | "}, - { 318 , ALARM_ID_HD_AIR_PUMP_TIMEOUT , "HD | Air Trap Control Error | A problem has been detected with the air trap level\ncontrol system.\n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue. | HD Fault: Air Pump Timeout | HD Air Pump operation timeout | If air pump has been turned on for greater than 10s. | "}, + { 318 , ALARM_ID_AVAILABLE_2 , " | | | | | | "}, { 319 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE , "DG | Residual Chemical Sampling | A water sample is needed to confirm the \nabsence of residual chemical following disinfection. \n- Test sample according to facility policy. \n- Confirm absence of residual chemical disinfectant. | Cleaning: Chem Residual Sampling | Collect sample to check the chemical disinfectant acid | Chemical disinfect flush sample alarm is prompted. | "}, { 320 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT , "DG | Chemical Residual Timeout | A chemical residual sample was not collected \n- within 30min of chemical flush.\n- To collect a sample for chemical residual,\nyou must repeat the chemical flush. | Cleaning: Chem Residual Timeout | The user did not proceed with collecting chemical disinfect flush sample for more than 30 minutes | Chemical disinfect flush sample was not collected form more than 30 minutes. | "}, { 321 , ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: UVo Error | Outlet reactor not healthy | If the outlet reactor are not healthy. | "},