Index: AlarmDefs.h =================================================================== diff -u -r82d9eed216d1d6897276d1417b3e0376bffcf963 -rca5d3d489388e0986f38004232d7b44c79b43077 --- AlarmDefs.h (.../AlarmDefs.h) (revision 82d9eed216d1d6897276d1417b3e0376bffcf963) +++ AlarmDefs.h (.../AlarmDefs.h) (revision ca5d3d489388e0986f38004232d7b44c79b43077) @@ -1,6 +1,6 @@ /************************************************************************** * -* Copyright (c) 2020-2025 Diality Inc. - All Rights Reserved. +* Copyright (c) 2020-2026 Diality Inc. - All Rights Reserved. * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. @@ -252,7 +252,7 @@ ALARM_ID_DG_CONCENTRATE_PUMPS_INVALID_CAL_RECORD = 214, ///< DG concentrate pumps invalid calibration record. ALARM_ID_HD_AIR_TRAP_UPPER_LEVEL_FLUID_TIME_OUT = 215, ///< HD air trap upper level fluid time out. ALARM_ID_HD_END_TREATMENT_TIMEOUT_ALARM = 216, ///< HD end treatment sub-mode timeout alarm - ALARM_ID_AVAILABLE_32 = 217, ///< Available for use + ALARM_ID_HD_AIR_TRAP_ACTIVITY_TOO_FREQUENT = 217, ///< HD air trap activity is too frequent alarm ALARM_ID_HD_SYRINGE_DETECTED = 218, ///< HD syringe detected alarm ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED = 219, ///< HD syringe pump syringe removed alarm ALARM_ID_DG_THD_SENSORS_FPGA_FAULT = 220, ///< DG THd sensors FPGA fault @@ -703,7 +703,7 @@ { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CONCENTRATE_PUMPS_INVALID_CAL_RECORD }, { ALARM_PRIORITY_HIGH, 200, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_AIR_TRAP_UPPER_LEVEL_FLUID_TIME_OUT }, { ALARM_PRIORITY_HIGH, 291, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_END_TREATMENT_TIMEOUT_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_32 }, + { ALARM_PRIORITY_HIGH, 200, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_AIR_TRAP_ACTIVITY_TOO_FREQUENT }, { ALARM_PRIORITY_LOW, 745, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_DETECTED }, { ALARM_PRIORITY_HIGH, 207, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_THD_SENSORS_FPGA_FAULT }, @@ -1029,6 +1029,7 @@ { 200, ALARM_ID_TEST_ALARM_NO_BLOOD_RECIRC_CLR_TOP_ONLY }, { 200, ALARM_ID_TEST_ALARM_NO_RECIRC_CLR_TOP_ONLY }, { 200, ALARM_ID_HD_AIR_TRAP_UPPER_LEVEL_FLUID_TIME_OUT }, + { 200, ALARM_ID_HD_AIR_TRAP_ACTIVITY_TOO_FREQUENT }, { 201, ALARM_ID_HD_VENOUS_PRESSURE_HIGH }, { 201, ALARM_ID_HD_VENOUS_LINE_OCCLUSION }, { 202, ALARM_ID_HD_ARTERIAL_PRESSURE_LOW }, @@ -1140,7 +1141,6 @@ { 999, ALARM_ID_AVAILABLE_20 }, { 999, ALARM_ID_AVAILABLE_21 }, { 999, ALARM_ID_AVAILABLE_30 }, - { 999, ALARM_ID_AVAILABLE_32 }, { 999, ALARM_ID_AVAILABLE_40 }, { 999, ALARM_ID_AVAILABLE_41 }, { 999, ALARM_ID_NO_ALARM }, @@ -1381,7 +1381,7 @@ { 214 , ALARM_ID_DG_CONCENTRATE_PUMPS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG POST: Conc Pump Cal | DG concentrate pump calibration record | If the non-volatile data is invalid raise the alarm. | "}, { 215 , ALARM_ID_HD_AIR_TRAP_UPPER_LEVEL_FLUID_TIME_OUT , "HD | Air Trap Overfill | Air trap level high for too long. \n- Assess venous access and resolve access issues, if applicable.\n- Ensure venous chamber line is securely clamped.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- Inspect blood lines for clots, address as clinically indicated\n per facility policy. \n- Press Resume/OK to continue treatment.| Air Trap: Air Trap Overfill | HD air trap upper level fluid detection for too long alarm | If air trap upper level is detecting fluid for more than 60 seconds. | "}, { 216 , ALARM_ID_HD_END_TREATMENT_TIMEOUT_ALARM , "HD | Treatment Complete | Dialysis treatment is complete.\n- Press RINSEBACK to end treatment and rinseback. | Process: End of Dialysis Tx | HD end treatment sub-mode timeout alarm | If the treatment ended successfully. | "}, - { 217 , ALARM_ID_AVAILABLE_32 , " | | | | | | "}, + { 217 , ALARM_ID_HD_AIR_TRAP_ACTIVITY_TOO_FREQUENT , "HD | Air Trap Overfill | Air trap level high for too long. \n- Assess venous access and resolve access issues, if applicable.\n- Ensure venous chamber line is securely clamped.\n- Check air trap for foam and that transducers are secured.\n- Inspect transducer for moisture and change, if applicable.\n- Inspect blood lines for clots, address as clinically indicated\n per facility policy. \n- Press Resume/OK to continue treatment.| Air Trap: Air Trap Overfill | HD air trap upper level fluid detection for too long alarm | If air trap upper level is detecting fluid for more than 60 seconds. | "}, { 218 , ALARM_ID_HD_SYRINGE_DETECTED , "HD | Syringe Detected | Heparin syringe was not removed from device.\n- Remove heparin syringe.\n- Press Resume/OK to continue. | Process: Remove Syringe | HD syringe detected alarm | If the syringe detection switch > 2.0 volts. | "}, { 219 , ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED , "HD | Blood Stopped: Syringe Not Detected | There is a problem detecting a syringe in the heparin pump.\n- Confirm the heparin syringe is properly installed. \n- Press Resume/OK to resume treatment. | Blood Stop: Syringe Not Detected | HD syringe pump syringe removed alarm | If the syringe detection switch < 2.0 volts. | "}, { 220 , ALARM_ID_DG_THD_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: THD RTD Comm | DG THd sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "},