Index: AlarmDefs.h =================================================================== diff -u -r92917eb9d6360fe95075f5b5b7fab6043a13ab61 -r1d59c3a912ed12f72cc632c43afe3162ca3d9328 --- AlarmDefs.h (.../AlarmDefs.h) (revision 92917eb9d6360fe95075f5b5b7fab6043a13ab61) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 1d59c3a912ed12f72cc632c43afe3162ca3d9328) @@ -341,7 +341,7 @@ ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT = 303, ///< DG drain pump direction FPGA fault ALARM_ID_HD_INVALID_USAGE_RECORD_CRC = 304, ///< HD invalid usage record ALARM_ID_HD_CPU_RAM_ERROR = 305, ///< HD processor RAM error - ALARM_ID_AVAILABLE_50 = 306, ///< Alarm ID available + ALARM_ID_DG_TURN_OFF_INLET_WATER_VALVES = 306, ///< DG turn off inlet water valves ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT = 307, ///< HD AC power lost second alarm ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR = 308, ///< DG CPi conductivity sensor invalid character received ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR = 309, ///< DG CPo conductivity sensor invalid character received @@ -796,7 +796,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_USAGE_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_CPU_RAM_ERROR }, - { ALARM_PRIORITY_LOW, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_50 }, + { ALARM_PRIORITY_MEDIUM, 500, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_TURN_OFF_INLET_WATER_VALVES }, { ALARM_PRIORITY_HIGH, 100, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR }, @@ -1068,6 +1068,7 @@ { 441, ALARM_ID_DG_EXCESSIVE_TILT }, { 442, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM }, { 442, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM }, + { 500, ALARM_ID_DG_TURN_OFF_INLET_WATER_VALVES }, { 590, ALARM_ID_HD_PRIME_COMPLETED_MEDIUM }, { 600, ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE }, { 600, ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE }, @@ -1142,7 +1143,6 @@ { 999, ALARM_ID_AVAILABLE_30 }, { 999, ALARM_ID_AVAILABLE_31 }, { 999, ALARM_ID_AVAILABLE_32 }, - { 999, ALARM_ID_AVAILABLE_50 }, { 999, ALARM_ID_NO_ALARM }, }; @@ -1470,7 +1470,7 @@ { 303 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: DRP Hall Commutation | DG drain pump direction FPGA fault | If the FPGA indicates an error for a certain period of time. | "}, { 304 , ALARM_ID_HD_INVALID_USAGE_RECORD_CRC , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: Usage Rec NVRAM CRC | HD invalid usage reocord | If the CRC of the HD usage record does not match the calculated CRC. | "}, { 305 , ALARM_ID_HD_CPU_RAM_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD Fault: Processor RAM error | HD_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 306 , ALARM_ID_AVAILABLE_50 , " | | | | | | "}, + { 306 , ALARM_ID_DG_TURN_OFF_INLET_WATER_VALVES , "DG | Turn Off Inlet Water Valves | Heat disinfection is in progress.\n- Turn off inlet water valves. | Cleaning: Turn Off Inlet Water Valves | Selection of nocturnal heat disinfect | If the user has selected the nocturnal heat disinfect, the DG Software prompts the user to turn off the inlet water valves once the reservoirs are filled. | "}, { 307 , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT , "HD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n- Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed. | Blood Stop: Loss of AC Power | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, { 308 , ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: CPi Comm | DG CPi conductivity sensor transmits invalid characters | If the CPi conductivity sensor transmits invalid characters for a certain period of time. | "}, { 309 , ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: CPo Comm | DG CPo conductivity sensor transmits invalid characters | If the CPo conductivity sensor transmits invalid characters for a certain period of time. | "},