Index: AlarmDefs.h =================================================================== diff -u -r96b4ae6b669aa678893859394773ca89378b010d -r86cddfe2c1b0fc500c2d0c4639d81830a5a89dec --- AlarmDefs.h (.../AlarmDefs.h) (revision 96b4ae6b669aa678893859394773ca89378b010d) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 86cddfe2c1b0fc500c2d0c4639d81830a5a89dec) @@ -297,7 +297,7 @@ ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE = 259, ///< HD temperatures out of range ALARM_ID_HD_UI_POST_FAILURE_SHASUM = 260, ///< HD UI POST Application Integrity (Sha256Sum) failure ALARM_ID_HD_UI_POST_FAILURE_CANBUS = 261, ///< HD UI POST CANBus failure - ALARM_ID_HD_UI_POST_FAILURE_DISPLAY = 262, ///< HD UI POST Display failure + ALARM_ID_AVAILABLE_18 = 262, ///< Alarm Id available ALARM_ID_HD_UI_POST_FAILURE_TOUCH = 263, ///< HD UI POST Touch failure ALARM_ID_HD_UI_POST_FAILURE_SDCARD = 264, ///< HD UI POST SD-Card failure ALARM_ID_HD_UI_POST_FAILURE_RTC = 265, ///< HD UI POST RTC failure @@ -606,7 +606,7 @@ { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_END_OF_TREATMENT_HIGH }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TREATMENT_STOPPED_NO_RINSEBACK }, - { ALARM_PRIORITY_HIGH, 150, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_BLOOD_LEAK_DETECTED }, + { ALARM_PRIORITY_HIGH, 150, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_BLOOD_LEAK_DETECTED }, { ALARM_PRIORITY_HIGH, 200, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , ALARM_ID_HD_VENOUS_PRESSURE_LOW }, { ALARM_PRIORITY_HIGH, 12, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED, }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_17, }, @@ -747,7 +747,7 @@ { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_SHASUM }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_CANBUS }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, + { ALARM_PRIORITY_LOW, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_18 }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_TOUCH }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_SDCARD }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_RTC }, @@ -830,7 +830,6 @@ { 1, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, { 1, ALARM_ID_HD_UI_POST_FAILURE_SHASUM }, { 1, ALARM_ID_HD_UI_POST_FAILURE_CANBUS }, - { 1, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, { 1, ALARM_ID_HD_UI_POST_FAILURE_TOUCH }, { 1, ALARM_ID_HD_UI_POST_FAILURE_SDCARD }, { 1, ALARM_ID_HD_UI_POST_FAILURE_INVALID_YEAR }, @@ -1133,6 +1132,7 @@ { 999, ALARM_ID_AVAILABLE_15 }, { 999, ALARM_ID_AVAILABLE_16 }, { 999, ALARM_ID_AVAILABLE_17 }, + { 999, ALARM_ID_AVAILABLE_18 }, { 999, ALARM_ID_AVAILABLE_30 }, { 999, ALARM_ID_AVAILABLE_31 }, { 999, ALARM_ID_AVAILABLE_32 }, @@ -1158,329 +1158,329 @@ const ALARM_MANUAL_T ALARM_MANUAL_TABLE[] = { // Num Alarm ID Device Display Title Instructions Description Trigger Condition - { 0 , ALARM_ID_NO_ALARM , "N/A | ` | N/A | Indication for when no alarms is a possible situation | N/A | "}, - { 1 , ALARM_ID_HD_STUCK_BUTTON_TEST_FAILED , "HD | HD POST: Stuck Button | Stop or On button pressed during startup\n-Release button and power cycle\n-Call service to schedule a repair if problem persists | Stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up | Stop or Off button are pressed for more than 1 sec during POST. | "}, - { 2 , ALARM_ID_HD_FPGA_POST_TEST_FAILED , "HD | HD POST: FPGA Compatibility | Call service to schedule a repair. | HD FPGA POST failure | Minimum HD FPGA major revision is not compatible with this version of HD firmware or the FPGA Id is not correct. | "}, - { 3 , ALARM_ID_DG_FPGA_POST_TEST_FAILED , "DG | DG POST: FPGA Compatibility | Call service to schedule a repair. | DG FPGA POST failure | Minimum DG FPGA major and minor revision are not equal to the FPGA major and minor revision in FPGA header | "}, - { 4 , ALARM_ID_HD_WATCHDOG_POST_TEST_FAILED , "HD | HD POST: WD Safestate | Call service to schedule a repair. | HD Watchdog POST failure | If the following are not observed after 500ms of not petting the WD: 1. WD exp pin=low 2. 24V <= 5V 3. audio current >= 200mA If the following are not observed after 500ms of resumed WD petting at proper timing: 1. WD exp pin=high 2. 24V >= 22.6V 3. audio current <= 10 mA | "}, - { 5 , ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED , "DG | DG POST: WD Safestate | Call service to schedule a repair. | DG Watchdog POST failure | If the following are not observed after 500ms of not petting the WD: 1. WD exp pin=low 2. 24V <= 5V If the following are not observed after 750ms of resumed WD petting at proper timing: 1. WD exp pin=high 2. 24V >= 22.6V | "}, - { 6 , ALARM_ID_HD_UI_COMM_POST_FAILED , "HD | HD POST: Proc-UI Comm | Call service to schedule a repair. | UI communication POST failure. UI failed to communicate within a reasonable time after power up | If the UI failed to checkin via the CAN bus within 40 seconds | "}, - { 7 , ALARM_ID_HD_RTC_BATTERY_LOW , "HD | HD Alarm (Low): RTC Bat Low | Call service to schedule a repair. | Real-time clock configuration error | If the RTC is not functional as indicated by the bits in the first 3 control registers. | "}, - { 8 , ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE , "HD | HD POST: Acc Vector | Call service to schedule a repair. | HD accelerometer failed POST | If the calculated vector length of the accelerometer x, y, z is not the nominal length. | "}, - { 9 , ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE , "DG | DG POST: Acc Vector | Call service to schedule a repair. | DG accelerometer failed POST | If the calculated vector length of the accelerometer x, y, z is not the nominal length. | "}, - { 10 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_EMBEDDED_MODE_FAILURE , "HD | HD POST: BLD Config Emb Mode | Call service to schedule a repair. | HD blood leak sensor embedded mode communication failed | If the blood leak sensor embedded mode is unresponsive. | "}, - { 11 , ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP , "HD | Dial. Gen: Dialysate Temp Low | Dialysate temperature is low\n- Treatment is paused and will be ready to resume when \ndialysate is within target range. | Dialysate temperature is below the target temperature | If the dialysate temperature is below the target temperature for a certain period of time. | "}, - { 12 , ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED , "HD | HD POST: HD Image | Call service to schedule a repair. | HD firmware image integrity POST test failed | If the calculated CRC of the HD image does not match the expected CRC. | "}, - { 13 , ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED , "DG | DG POST: DG Image | Call service to schedule a repair. | DG firmware image integrity POST test failed | If the calculated CRC of the DG firmware image does not matched the expected CRC | "}, - { 14 , ALARM_ID_DG_INVALID_USAGE_RECORD_CRC , "DG | DG POST: Usage Rec NVRAM CRC | Call service to schedule a repair. | DG non-volatile usage information group invalid record CRC | If the DG usage information record's CRC does not match the calculated CRC in POST. | "}, - { 15 , ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP , "HD | Dial. Gen: Dialysate Temp High | Dialysate temperature is high\n-Treatment is paused and will be ready to resume when \ndialysate is within target range. | Dialysate temperature is out of high safety range | If the dialysate temperature is > 46 C for a certain period of time. | "}, - { 16 , ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE , "HD | HD POST: Primary Alarm Current | Call service to schedule a repair. | HD alarm audio failed POST | If alarm audio current is NOT in expected range for than 1 second while alarm tone is being output | "}, - { 17 , ALARM_ID_HD_UI_POST_TIMEOUT , "HD | HD POST: UI POST Not Complete | Call service to schedule a repair. | HD UI POST failed | If UI reports POST failed but did not trigger fault OR UI has not sent POST results within 2 seconds. | "}, - { 18 , ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_BY_DG , "HD | Loss of DG Comm (DG ACK) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD to DG comm error. | HD message to DG that requires acknowledge was not acknowledged within a certain time. | "}, - { 19 , ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP , "HD | Dial. Gen: Dialysate Temp High | Dialysate temperature is high\n- Treatment is paused and will be ready to resume when \ndialysate is within target range. | Dialysate temperature is above the target temperature | If the dialysate temperature is above the target temperature for a certain period of time. | "}, - { 20 , ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD , "DG | DG POST: Conductivity Cal | Call service to schedule a repair. | DG conductivity sensors invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, - { 21 , ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD , "DG | DG POST: Drain Line Vol Cal | Call service to schedule a repair. | DG drain line volume invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, - { 22 , ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD , "DG | DG POST: Reservoir Vol Cal | Call service to schedule a repair. | DG reservoirs invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, - { 23 , ALARM_ID_DG_ACID_CONCENTRATE_INVALID_CAL_RECORD , "DG | DG POST: Acid Conc Cal | Call service to schedule a repair. | DG acid concentrate calibration record | If the non-volatile data is valid and if not raise the alarm | "}, - { 24 , ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD , "DG | DG POST: Bicarb Conc Cal | Call service to schedule a repair. | DG bicarb concentrate calibration record | If the non-volatile data is valid and if not raise the alarm | "}, - { 25 , ALARM_ID_DG_ACCELEROMETERS_INVALID_CAL_RECORD , "DG | DG POST: Acc Cal | Call service to schedule a repair. | DG accelerometer invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, - { 26 , ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD , "HD | HD POST: Acc Cal | Call service to schedule a repair. | HD accelerometer invalid calibration record | If the accel calibration data that was received from NVDataMgmt is NOT legitimate. | "}, - { 27 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED , "HD | Process: Pre-Tx Wet Self-Test | Self-test detected has a problem with the blood leak sensor\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. | HD BLD sensor failed zero sequence | BLD fails to complete zero sequence. | "}, - { 28 , ALARM_ID_DG_TWO_WIRE_SENSORS_FPGA_FAULT , "DG | DG Fault: Conductivity RTD Comm | Call service to schedule a repair. | DG two wire sensors FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 29 , ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD , "HD | HD POST: SP DAC Cal | Call service to schedule a repair. | HD heparin force sensor invalid calibration record | If the heparin force sensor calibration data that was received from NVDataMgmt is NOT legitimate. | "}, - { 30 , ALARM_ID_HD_SOFTWARE_FAULT , "HD | HD Fault: SW Invalid State | Call service to schedule a repair. | HD Software fault. Software found itself in an unexpected state | If the specific software faults listed in alarm management SW faults has been detected | "}, - { 31 , ALARM_ID_HD_BLOOD_PUMP_MC_CURRENT_CHECK , "HD | HD Fault: BP Current | Call service to schedule a repair. | Blood pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the measured MC current is not greater than BP_MAX_CURR_WHEN_STOPPED_MA or is not greater than BP_MAX_CURR_WHEN_RUNNING_MA. | "}, - { 32 , ALARM_ID_HD_BLOOD_PUMP_OFF_CHECK , "HD | HD Fault: BP Speed | Call service to schedule a repair. | Blood pump failed motor off check. Measured speed while commanded off | If the measured motor speed is greater than BP_MAX_MOTOR_SPEED_WHILE_OFF_RPM | "}, - { 33 , ALARM_ID_HD_BLOOD_PUMP_MC_DIRECTION_CHECK , "HD | HD Fault: BP Direction | Call service to schedule a repair. | Blood pump failed motor direction check. Measured vs. commanded | If the set direction versus hall sensors direction versus sign of motor speed DOES NOT agree. | "}, - { 34 , ALARM_ID_HD_BLOOD_PUMP_ROTOR_SPEED_CHECK , "HD | HD Fault: BP Rotor | Blood pump rotor failure.\n- Check the pump rotor for secure connection. | Blood pump failed rotor speed check. Mismatch with rotor and motor speeds | If the delta of the measured motor speed and the commanded motor speed is not within tolerance. | "}, - { 35 , ALARM_ID_HD_DIAL_IN_PUMP_MC_CURRENT_CHECK , "HD | HD Fault: DPi Current | Call service to schedule a repair. | Dialysis inlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the Motor Controller measured DPi pump current > 150.0 mA for more than 250.0 msec. | "}, - { 36 , ALARM_ID_HD_DIAL_IN_PUMP_OFF_CHECK , "HD | HD Fault: DPi Speed | Call service to schedule a repair. | Dialysis inlet pump failed motor off check. Measured speed while commanded off | If during command off state, the DPi pump motor speed is measured > 100.0 RMP. | "}, - { 37 , ALARM_ID_HD_DIAL_IN_PUMP_MC_DIRECTION_CHECK , "HD | HD Fault: DPi Direction | Call service to schedule a repair. | Dialysis inlet pump failed motor direction check. Measured vs. commanded | If the set direction versus hall sensors direction DO NOT agree for more than 250.0 msec. | "}, - { 38 , ALARM_ID_HD_DIAL_IN_PUMP_ROTOR_SPEED_CHECK , "HD | HD Fault: DPi Rotor | Dialysate in pump rotor failure.\n- Check the pump rotor for secure connection. | Dialysis inlet pump failed rotor speed check. Mismatch with rotor and motor speeds | If the measured motor speed versus the measured motor speed while controlling the target > 5.0 for more than 12 seconds. | "}, - { 39 , ALARM_ID_HD_DIAL_OUT_PUMP_MC_CURRENT_CHECK , "HD | HD Fault: DPo Current | Call service to schedule a repair. | Dialysis outlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the DPo pump current > 150.0 mA while stopped or Dpo current > 2000.0 mA for more than 2 seconds while running. | "}, - { 40 , ALARM_ID_HD_DIAL_OUT_PUMP_OFF_CHECK , "HD | HD Fault: DPo Speed | Call service to schedule a repair. | Dialysis outlet pump failed motor off check. Measured speed while commanded off | If the Dpo pump current > 100.0 RPM while commanded off for more than 5000 msec. | "}, - { 41 , ALARM_ID_HD_DIAL_OUT_PUMP_MC_DIRECTION_CHECK , "HD | HD Fault: DPo Direction | Call service to schedule a repair. | Dialysis outlet pump failed motor direction check. Measured vs. commanded | If the DPo pump set direction does not agree with hall sensors or set direction does not agree with the sign of the motor speed for more than 25 msec. | "}, - { 42 , ALARM_ID_HD_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK , "HD | HD Fault: DPo Rotor | Dialysate out pump rotor failure.\n- Check the pump rotor for secure connection. | Dialysis outlet pump failed rotor speed check. Mismatch with rotor and motor speeds | If DPo pump measured rotor speed does not agreed with the measured/commanded motor speed | "}, - { 43 , ALARM_ID_DG_MAIN_PRIMARY_HEATER_FPGA_FAULT , "DG | DG Fault: Iso ADC Comm | Call service to schedule a repair. | Main primary heater FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 44 , ALARM_ID_HD_UI_COMM_TIMEOUT , "HD | HD Fault: UI Comm | Call service to schedule a repair. | User interface communication timeout | If the sub-system communication timeout has occurred. UI is 5 seconds. DG is 2 seconds. | "}, - { 45 , ALARM_ID_HD_COMM_TOO_MANY_BAD_CRCS , "HD | HD Fault: CAN CRC Com | Call service to schedule a repair. | Too many bad CRCs detected on received system messages | If too many bad messages CRCs are received within a set period of time | "}, - { 46 , ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_BY_UI , "HD | HD Fault: CAN ACK UI Com | Call service to schedule a repair. | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, - { 47 , ALARM_ID_AVAILABLE_16 , " | | | | | "}, - { 48 , ALARM_ID_HD_UF_VOLUME_ACCURACY_ERROR , "HD | HD Fault: UF Rate Tare Err | Call service to schedule a repair. | Ultrafiltration volume accuracy error during treatment | If the UF volume (refUFvolume - measureVolume) > 100.0 mL. | "}, - { 49 , ALARM_ID_HD_FPGA_COMM_TIMEOUT , "HD | HD Fault: FPGA Com | Call service to schedule a repair. | HD FPGA communication down for too long | If there are more than 3 comm errors in a 1 min period. | "}, - { 50 , ALARM_ID_DG_VALVE_CONTROL_FAILURE , "DG | DG Fault: Valve Control | Call service to schedule a repair. | DG FPGA not accepting commanded valve states | If the read back FPGA valve states does not match the commanded valve states for a certain amount of time. | "}, - { 51 , ALARM_ID_HD_BLOOD_PUMP_MOTOR_SPEED_CHECK , "HD | HD Fault: BP Speed | Call service to schedule a repair. | Blood pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded rotor speed exceeded limits. | "}, - { 52 , ALARM_ID_HD_DIAL_IN_PUMP_MOTOR_SPEED_CHECK , "HD | HD Fault: DPi Speed | Call service to schedule a repair. | Dialysate inlet pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded motor speed exceeded limits for more than 5 secs. | "}, - { 53 , ALARM_ID_HD_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK , "HD | HD Fault: DPo Speed | Call service to schedule a repair. | Dialysate outlet pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded motor speed exceeded limits for more than 5 secs. | "}, - { 54 , ALARM_ID_HD_CRITICAL_DATA_ERROR , "HD | HD Fault: Critical Data Err | Call service to schedule a repair. | HD critical data integrity check failed | If the critical data failed range check. | "}, - { 55 , ALARM_ID_DG_CRITICAL_DATA_ERROR , "DG | DG Fault: Critical Data Err | Call service to schedule a repair. | DG critical data integrity check failed | If the critical data failed range check. | "}, - { 56 , ALARM_ID_HD_ACCELEROMETER_FAILURE , "HD | HD Fault: Acc Com | Call service to schedule a repair. | HD accelerometer error (no readings or FPGA reports error) | If no fresh sample of accelerometer data has been detected for more than 100 msec. | "}, - { 57 , ALARM_ID_DG_ACCELEROMETER_FAILURE , "DG | DG Fault: Acc Com | Call service to schedule a repair. | DG accelerometer error (no readings or FPGA reports error) | If no fresh sample of accelerometer data has been detected for more than 100 msec. | "}, - { 58 , ALARM_ID_HD_VALVE_HOMING_FAILED , "HD | HD Fault: Valve Home | Call service to schedule a repair. | HD valve homing failed | If the number of failed homing > = 3 counts. | "}, - { 59 , ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT , "HD | HD Fault: Valve Transition Err | Call service to schedule a repair. | HD valve transition time out | if the valve's transition time has timed out (3000msec) | "}, - { 60 , ALARM_ID_HD_VALVE_NOT_FUNCTIONAL , "HD | HD Fault: Valve Control | Call service to schedule a repair. | HD valve not functional | If the valve bit masks are not as expected in different valve control mode. | "}, - { 61 , ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE , "HD | HD Fault: Valve Current | Call service to schedule a repair. | HD valve current out of range | If the valve current is over the threshold of 1.0 A for 1000 msec. | "}, - { 62 , ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE , "HD | HD Fault: Valve Position | Call service to schedule a repair. | HD valve position out of target | If the current position has deviated from the expected position for more than 1 second. | "}, - { 63 , ALARM_ID_HD_BLOOD_LEAK_FPGA_FAULT , "HD | HD Fault: BLD Com | Call service to schedule a repair. | FPGA reports error | If the FPGA error counter increments for a certain period of time. | "}, - { 64 , ALARM_ID_DG_BARO_PRESSURE_OUT_OF_RANGE , "DG | DG Fault: Baro Range | Call service to schedule a repair. | Barometric pressure is out of range | If the barometric pressure is > 10.1 psi or < 15.4 psi for a certain period of time. | "}, - { 65 , ALARM_ID_HD_DG_COMMAND_INVALID_PARAMETER_FAULT , "HD | Loss of DG Comm (Reject) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD requests DG command with invalid parameter fault | If the latest DG command response indicated invalid parameter | "}, - { 66 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE , "HD | HD POST: BLD Config Set Point | Call service to schedule a repair. | HD blood leak sensor set point set failure | If the set point of the blood leak sensor does not match the set point in the calibration record. | "}, - { 67 , ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE , "HD | Process: Pre-Tx Remove Cartridge | Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume | HD blood pump occlusion self-test failure alarm | If the blood pump pressure > 5000 | "}, - { 68 , ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE , "HD | Dial. Gen: Dialysate not ready | Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when \ndialysate is ready for use. | HD active reservoir recirculation out of range | If the recirculation level has exceeded the max allowed | "}, - { 69 , ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD , "HD | HD POST: BLD Cal | Call service to schedule a repair. | HD blood leak sensor invalid calibration record | If the BLD data that was received from NVDataMgmt is NOT legitimate. | "}, - { 70 , ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE , "HD | Process: Pre-Tx Remove Cartridge | Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume | HD arterial pressure self-test failure alarm | If arterial pressure < -300 or > 100 mmHg | "}, - { 71 , ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE , "HD | Process: Pre-Tx Remove Cartridge | Cartridge has been detected.\n- Open door\n- Remove cartridge\n- Close door\n- Resume | HD venous pressure self-test failure alarm | If the venous pressure < -100 or > 600 mmHg | "}, - { 72 , ALARM_ID_HD_NEW_LOAD_CELL_DATA_MESSAGE_NOT_RECEIVE , "HD | Loss of DG Comm (LC) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD No load cell data message receive at least once every 2 seconds | No new load cell data for 2 seconds. | "}, - { 73 , ALARM_ID_HD_NEW_DIALYSATE_TEMP_DATA_MESSAGE_NOT_RECEIVE , "HD | Loss of DG Comm (TDI/TRO) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD No dialysate temperature data message received at least once every 2 seconds | No new dialysate temperature data for 2 seconds. | "}, - { 74 , ALARM_ID_DG_INLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | DG Fault: UVi On No Flow | Call service to schedule a repair. | DG inlet UV reactor is on while there is no flow | If the inlet UV reactor is on while VPi is closed for a certain period of time. | "}, - { 75 , ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE , "HD | HD Fault: Syringe DAC | Call service to schedule a repair. | HD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, - { 76 , ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE , "HD | HD Fault: Voltage Monitor | Call service to schedule a repair. | HD monitored voltage is out of range | If the HD monitored voltages are out of range for a certain period of time. | "}, - { 77 , ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE , "DG | DG Fault: Voltage Monitor | Call service to schedule a repair. | DG monitored voltage is out of range | If the DG monitored voltages are out of range for a certain period of time. | "}, - { 78 , ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR , "HD | HD Fault: Syringe Pump Enc Dir | Call service to schedule a repair. | HD syringe pump direction (from encoder) error | If the measured encoder direction of the syringe pump does not agree with the expected direction | "}, - { 79 , ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR , "HD | HD Fault: Syringe Pump Drv Dir | Call service to schedule a repair. | HD syringe pump direction (from controller) error | If the measured direction of the syringe pump motor controller does not agree with the expected direction | "}, - { 80 , ALARM_ID_HD_SYRINGE_PUMP_FAULT , "HD | HD Fault: Syringe Pump Driver | Call service to schedule a repair. | HD syringe pump fault reported by FPGA | If the FPGA reported the syringe pump fault | "}, - { 81 , ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR , "HD | HD Fault: Syringe Pump OT | Call service to schedule a repair. | HD syringe pump over travel error | If the syringe pump position is deemed to have overtraveled | "}, - { 82 , ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR , "HD | HD Fault: Syringe Pump DAC Err | Call service to schedule a repair. | HD syringe pump DAC write failure | If the syringe pump DAC write error is reported by the FPGA | "}, - { 83 , ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "HD | HD Fault: Syringe Pump On Err | Call service to schedule a repair. | HD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, - { 84 , ALARM_ID_DG_SET_RTC_YEAR_INVALID , "DG | DG POST: HD RTC Time | Call service to schedule a repair. | DG RTC set year is invalid | If DG RTC set year is < 2021. | "}, - { 85 , ALARM_ID_HD_PUMP_TRACK_LATCH_OPENED , "HD | Blood Stop: Cartridge Lever Open | Cartridge Lock Lever is not closed.\n- Open front door and push lever all the way down.\n- Close door and press RESUME button to continue. | HD pump track lever is not fully latched | If the pump track lever is detected as unlatched when it should be. | "}, - { 86 , ALARM_ID_HD_SET_RTC_YEAR_INVALID , "HD | HD POST: HD RTC Time | Call service to schedule a repair. | HD RTC set year is invalid | If HD RTC set year is < 2021. | "}, - { 87 , ALARM_ID_DG_HEATING_INVALID_CAL_RECORD , "DG | DG POST: Heat Cal | Call service to schedule a repair. | DG heating parameters invalid calibration record | If the heating paramters' non-volatile record's CRC does not match the calculated CRC. | "}, - { 88 , ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE , "DG | DG Fault: CP1 CP2 Speed Range | Call service to schedule a repair. | DG concentrate pump hall sensor out of range. | Hall sensor pulse to pulse timing is < 1ms (speed too fast). | "}, - { 89 , ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | DG Fault: UVo On No Flow | Call service to schedule a repair. | DG outlet UV reactor is on while there is no flow | If the outlet UV reactor is on while the RO flow is less than 200 mL/min. | "}, - { 90 , ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT , "DG | DG Fault: LC A1/B1 Comm | Call service to schedule a repair. | DG load cells A1/B1 FPGA fault | If the FPGA does not report fresh data for a certain period of time. | "}, - { 91 , ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE , "HD | Loss of DG Comm (FMD) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD No dialysate flow data received in the last 3 seconds | If not receiving new dialysate flow readings in expected interval (3 seconds) | "}, - { 92 , ALARM_ID_AVAILABLE_1 , " | | | | | "}, - { 93 , ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE , "DG | DG Fault: RO Permeate Cond High | Call service to schedule a repair. | DG outlet primary conductivity sensor out of range | If the outlet primary conductivity sensor, CPo is greater than 30 uS/cm for a certain period of time. | "}, - { 94 , ALARM_ID_DG_PRESSURE_OUT_OF_RANGE , "DG | DG Fault: Pressure Sensor Range | Call service to schedule a repair. | DG pressure sensor out of range | If either of the pressure sensors is < 0 psia or > 200 psia for DG pressure sensors. | "}, - { 95 , ALARM_ID_DG_WATCHDOG_EXPIRED , "DG | DG Fault: WD Error | Call service to schedule a repair. | DG watchdog expired | If the watchdog signal is low while not in POST. | "}, - { 96 , ALARM_ID_DG_INLET_WATER_TEMPERATURE_IN_HIGH_RANGE , "DG | Dial. Gen: Inlet Water Temp High | Inlet water temperature is high.\n- Treatment is paused\n- Check the incoming water supply. | DG inlet water temperature out of range | If the inlet water temperature is > 37 C. | "}, - { 97 , ALARM_ID_DG_FILL_CONDUCTIVITY_OUT_OF_RANGE , "DG | Dial. Gen: Dialysate Cond. | Dialysate conductivity is out of range.\n- Check acid and bicarb concentrate is correct and not empty. | DG fill conductivity out of range | If the average acid or bicard conductivity is > 5% of the normal acid and bicarb conductivity values. | "}, - { 98 , ALARM_ID_HD_BATTERY_COMM_FAULT , "HD | HD Alarm (Low): Battery Com | Call service to schedule a repair. | HD battery or battery charger communication fault | If battery I2C communication fault persistence count > 5. | "}, - { 99 , ALARM_ID_HD_SYRINGE_PUMP_STALL , "HD | HD Fault: Syringe Pump Stall | Call service to schedule a repair. | HD syringe pump stall alarm | If syringe pump measured rate < stall speed threshold (0.05) and the ramp up has been restarted 3 times after stall has been detected. | "}, - { 100 , ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT , "HD | HD Fault: Timeout No Cart ST | Call service to schedule a repair. | HD no cartridge self-test timeout | If during the no cartridge self-tests state, the elapsed self-test time > maximum no cartridge self test time (30secs) | "}, - { 101 , ALARM_ID_UI_POST_HD_COMM , "UI | HD POST: UI-Proc Comm | Call service to schedule a repair. | UI POST FW Communication failure | If the HD is not communicating with the UI during POST. | "}, - { 102 , ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE , "DG | Cleaning: Tpo THD Temp Delta | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG heat disinfection temperature gradient out of range | If temperature gradient between Tpo and Thd exceeds maximum 15°C. | "}, - { 103 , ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID , "HD | HD POST: Cal NVRAM CRC | Call service to schedule a repair. | HD non-volatile calibration group invalid record CRC | If the computed CRC of the calibration group record is not equal to the record CRC. | "}, - { 104 , ALARM_ID_HD_AIR_TRAP_ILLEGAL_LEVELS , "HD | HD Fault: Air Trap Sensor | Call service to schedule a repair. | Air trap level sensors reporting illegal combination of air/fluid | If the air trap level readings are not valid for more than 2 seconds. | "}, - { 105 , ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID , "DG | DG POST: Cal NVRAM CRC | Call service to schedule a repair. | DG non-volatile system group invalid record CRC | If the DG NVDATAMGMT CAL group calculated CRC does not mached the expected CRC. | "}, - { 106 , ALARM_ID_DG_FLOW_SENSORS_INVALID_CAL_RECORD , "DG | DG POST: Flow Sensor Cal | Call service to schedule a repair. | DG flow sensors calibration error | If the calculated CRC of the flow sensors calibration record does not match the calibration records' CRC. | "}, - { 107 , ALARM_ID_HD_DG_RESTARTED_FAULT , "HD | DG Fault: DG Restarted | Call service to schedule a repair. | HD reports DG restarted fault | If DG reports being in any mode other than idle, drain, fill or fault during pre-tx, tx, or post-tx modes - means DG restarted unexpectedly and is no longer in sync w/ HD. | "}, - { 108 , ALARM_ID_HD_SYRINGE_PUMP_FPGA_ADC_FAULT , "HD | HD Fault: Syringe Pump ADC Com | Call service to schedule a repair. | HD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, - { 109 , ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR , "HD | HD Fault: Syringe Pump Vol | Call service to schedule a repair. | HD syringe pump volume check error | If the volume delivered is off by more than 5% or 0.1mL. | "}, - { 110 , ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR , "HD | HD Fault: Syringe Pump Speed | Call service to schedule a repair. | HD syringe pump speed check error | If the syringe measured rate is off by more than 5% or 0.1mL. | "}, - { 111 , ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR , "HD | HD Fault: Syringe Pump Speed | Call service to schedule a repair. | HD syringe pump not stopped in off state error | If the syringe pump position is not equal to its last position. | "}, - { 112 , ALARM_ID_DG_LOAD_CELL_A2_B2_FPGA_FAULT , "DG | DG Fault: LC A2/B2 Comm | Call service to schedule a repair. | DG load cells A2/B2 FPGA fault | If the FPGA does not report fresh data for a certain period of time. | "}, - { 113 , ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE , "DG | DG Fault: DRP Current | Call service to schedule a repair. | DG drain pump current out of range | If the DG drain pump current > 2.2 A when it is in open loop or if the current > 0.1 A when it is off. | "}, - { 114 , ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE , "HD | Process: Pre-Tx Wet Self-Test | Self-test has detected a problem with the air bubble sensor\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and \nrestart with a new cartridge. | HD venous air bubble detector self-test failure | If the venous air bubble self test did not detect bubble for more than 500 msec. | "}, - { 115 , ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE , "DG | DG Fault: Temp Sensor Range | Call service to schedule a repair. | DG temperature sensor out of range | If the measured temperature < 0 C or > 80 C for the non-fluid inline sensors and > 120 C for the fluid sensors. | "}, - { 116 , ALARM_ID_HD_UI_SDCARD_FAILURE , "UI HD | HD Alarm (Low): SD-Card Error | SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists. | SD card is non-operational | SD card is non-operational | "}, - { 117 , ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED , "DG | Loss of HD Comm (HD ACK) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, - { 118 , ALARM_ID_DG_RTC_CONFIG_ERROR , "DG | DG Fault: RTC Config | Call service to schedule a repair. | DG RTC configuration error | If the RTC configuration registers report an error. | "}, - { 119 , ALARM_ID_DG_RTC_BATTERY_LOW , "DG | DG Alarm (Low): RTC Bat Low | Call service to schedule a repair. | DG RTC battery low | If the RTC battery bit report a low alarm. | "}, - { 120 , ALARM_ID_HD_PRE_TREATMENT_WET_PRIME_TEST_FAILURE , "HD | Process: Pre-Tx Wet Self-Test | Self-test has detected a bubble in the venous bubble detector\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and \nrestart with a new cartridge. | HD pre-treatment wet prime test failure | If the HD pre-treatment wet self test failed. | "}, - { 121 , ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | DG Fault: Prim Heater Lg Control | Call service to schedule a repair. | DG main primary heater voltage out of range | If the main primary heater's voltage is out of range. | "}, - { 122 , ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | DG Fault: Prim Heater Sm Control | Call service to schedule a repair. | DG small primary heater voltage out of range | If the small primary heater's voltage is out of range. | "}, - { 123 , ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | DG Fault: Trimmer Heater Control | Call service to schedule a repair. | DG trimmer heater voltage out of range | If the trimmer voltage is out of range. | "}, - { 124 , ALARM_ID_HD_END_OF_TREATMENT_HIGH , "HD | Blood Stop: Blood Clot Risk | Blood pump has been off for too long.\n- Treatment must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. | HD end of treatment alarm (high priority - user still not acting to end treatment) | In treatment end paused state for > 5 minutes. | "}, - { 125 , ALARM_ID_HD_TREATMENT_STOPPED_NO_RINSEBACK , "HD | Blood Stop: Blood Clot Risk | Blood pump has been off for too long.\n- Treatment must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. | Blood sitting too long after treatment stopped by user alarm (> 5 min) | If in treatment stop sub mode when blood is in the tubing, the blood sitting counter exceeded 5 minutes. | "}, - { 126 , ALARM_ID_HD_BLOOD_LEAK_DETECTED , "HD | Blood Stop: Dialyzer Blood Leak | A blood leak has been detected. Treatment must end. | HD blood leak detected alarm | If the blood leak is detected based on the blood leak status reported by the sensor. | "}, - { 127 , ALARM_ID_HD_VENOUS_PRESSURE_LOW , "HD | Blood Stop: Venous Pres. Low | Venous pressure is low.\n- Check to be sure your blue venous connections are secure.\n- Check that your venous access is connected and secured \nproperly. | Venous pressure too low during treatment | If the venous pressure < TREATMENT_PARAM_VEN_PRESSURE_LOW_LIMIT. Or expanded pressure limits based on mode of operation. | "}, - { 128 , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED , "HD | Blood Stop: Venous Air Bubble | Venous air bubble detected indicating failure of air trap \ncontrol system.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement. | HD venous air bubble detected alarm | If bubbles are detected during the treatment. | "}, - { 129 , ALARM_ID_AVAILABLE_17 , " | | | | | "}, - { 130 , ALARM_ID_HD_VENOUS_PRESSURE_HIGH , "HD | Blood Stop: Venous Pres. High | Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. | Venous pressure too high during treatment | If the venous pressure > TREATMENT_PARAM_VEN_PRESSURE_HIGH_LIMIT. Or expanded pressure limits based on mode of operation. | "}, - { 131 , ALARM_ID_HD_ARTERIAL_PRESSURE_LOW , "HD | Blood Stop: Arterial Pres. Low | Arterial pressure is low.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure the red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. | Arterial pressure too low during treatment | If the arterial pressure < TREATMENT_PARAM_ART_PRESSURE_LOW_LIMIT. Or expanded pressure limits based on mode of operation. | "}, - { 132 , ALARM_ID_HD_ARTERIAL_PRESSURE_HIGH , "HD | Blood Stop: Arterial Pres. High | Arterial pressure is high.\n- Check that the access is properly connected and secured.\n- Resolve access issue if applicable.\n- Check to be sure your red arterial connections are secure.\n- Check that there are no kinks or clots in the tubing.\n- Unkink lines if applicable.\n- End treatment and do not return blood if clots are present. | Arterial pressure too high during treatment | If the arterial pressure > TREATMENT_PARAM_ART_PRESSURE_HIGH_LIMIT. Or expanded pressure limits based on mode of operation. | "}, - { 133 , ALARM_ID_DG_FLUID_LEAK_DETECTED , "DG | DG Fault: Fluid Leak in DG | Fluid leak detected in Dialysate Generation Delivery Device.\n-Treatment must be terminated.\n- Shut off water source and disconnect water and \nelectrical connections from system.\n- Call service to schedule a repair. | DG fluid leak detected alarm | If the fluid leak is detected as reported by the fluid leak detector. | "}, - { 134 , ALARM_ID_HD_FLUID_LEAK_DETECTED , "HD | Blood Stop: Fluid Leak in HD | Fluid leak detected in Hemodialysis Delivery device.\n- If in treatment, BLOOD STOPPED.\n-Identify and correct the cause of the spill.\n- Clean up the spill and dry leak sensor.\n- If in treatment, resume treatment. | HD fluid leak detected alarm | If the fluid leak is detected as reported by the fluid leak detector. | "}, - { 135 , ALARM_ID_HD_SHOCK , "HD | Blood Stop: HD Shock Detected | Excessive movement detected with Hemodialysis Delivery \ndevice.\n- Confirm the device is stationary and level before continuing. | HD experienced large acceleration | If the system experienced excessive shock > 2.5 g. | "}, - { 136 , ALARM_ID_DG_SHOCK , "DG | Dial. Gen: Shock-Vibration | Excessive movement detected with Dialysis Generation \ndevice.\n- Treatment is paused.\n- Confirm the device is stationary and level before continuing. | DG experienced large acceleration | If the system experienced excessive shock > 2.5 g. | "}, - { 137 , ALARM_ID_HD_EXCESSIVE_TILT , "HD | Blood Stop: HD Tilted | Excessive tilt detected with Hemodialysis Delivery device.\n- Confirm the device is stationary and level before continuing. | HD tilt exceeds maximum | If the system experienced excessive tilt x and y axis angle > 7 deg for more than 1 sec. | "}, - { 138 , ALARM_ID_DG_EXCESSIVE_TILT , "DG | Dial. Gen: Tilt | Excessive tilt detected with Dialysis Generation device.\n- Treatment is paused.\n-Confirm the device is stationary and level before continuing. | DG tilt exceeds maximum | If the system experienced excessive tilt x and y axis angle > 7 deg for more than 1 sec. | "}, - { 139 , ALARM_ID_HD_AC_POWER_LOST , "HD | Loss of AC Power | Power has been lost. Check all electrical connections.\n- The display and CPU will run off of the battery until \npower returns. | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in standby, service, or treatment parameters mode. | "}, - { 140 , ALARM_ID_HD_DG_COMM_TIMEOUT , "HD | Loss of DG Comm (Timeout) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | Dialysate generator communication timeout | If DG communication timeout is detected for more than 2 seconds. | "}, - { 141 , ALARM_ID_HD_AIR_TRAP_FILL_DURING_TREATMENT , "HD | Blood Stop: Air Trap Fill | Failure to fill the Air Trap.\n- Treatment must be terminated without option for rinseback.\n- Check access for dislodgement. | Air trap fill timeout during treatment | If the air trap fill timeout during treatment. | "}, - { 142 , ALARM_ID_HD_OCCLUSION_BLOOD_PUMP , "HD | Blood Stop: Blood Pump Occlusion | Occlusion detected after the blood pump.\n- Check for clots or kinks around the dialyzer and in the \nvenous line.\n- Resolve access issue if applicable.\n- End treatment and do not return blood if clots are present.\n- Check for access or patient discomfort.\n- Unkink the lines if applicable. | Blood pump occlusion detected | If blood occlusion is detected > OCCLUSION_THRESHOLD_OFFSET + bloodPumpOcclusionAfterCartridgeInstall | "}, - { 143 , ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE , "DG | DG Fault: TRo TDi Delta | Call service to schedule a repair. | DG dialysate temperature sensors drift timeout. | If TDi and TRo have drifted for more 1 C for a certain period of time. | "}, - { 144 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_HIGH , "DG | Cleaning: Inlet Water Cond High | Cleaning Mode Inlet water conductivity too high.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. | DG cleaning mode inlet water conductivity out of high range | Inlet water conductivity > 2000 uS/cm. Inlet water conductivity > 100 uS/cm (PURE WATER MODE). In cleaning mode | "}, - { 145 , ALARM_ID_DG_ACID_CONDUCTIVITY_OUT_OF_RANGE , "DG | Dial. Gen: Acid Conc. Cond. | Acid concentrate conductivity during prime is out of range.\n- Check correct acid concentrate is connected and full.\n- Resume to reprime concentrate. | DG Concentrate conductivity after adding acid out of range alarm | If the conductivity value for the acid concentrate is out of range for more than 45 secs. | "}, - { 146 , ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE , "DG | DG POST: DG RTC Timer | Call service to schedule a repair. | DG RTC vs. Timer accuracy error | If RTC and timer are not aligned on 1 second elapsed time. | "}, - { 147 , ALARM_ID_DG_CREATING_DIALYSATE_PLEASE_WAIT , "DG | Dial. Gen: Dialysate not ready | Dialysate is not yet ready.\n- Treatment is paused and will be ready to resume when \ndialysate is ready for use. | DG dialysate generation conductivity fault alarm | If dialysate conductivity is not with 5% of the TCD | "}, - { 148 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_HIGH , "DG | Cleaning: Inlet Water Temp High | Cleaning Mode Inlet water temperature too high.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. | Cleaning Mode Inlet water temperature too high | Inlet temperature > 37 C. | "}, - { 149 , ALARM_ID_HD_WATCHDOG_EXPIRED , "HD | HD Fault: WD Error | Call service to schedule a repair. | HD watchdog expired | If the watchdog signal is low while not in POST. | "}, - { 150 , ALARM_ID_DG_INLET_WATER_CONDUCTIVITY_IN_HIGH_RANGE , "DG | Dial. Gen: Inlet Water Cond High | Inlet water conductivity is high.\n- Treatment is paused.\n- Check the incoming water supply. | Inlet water conductivity too high | Inlet water conductivity > 2000 uS/cm. Inlet water conductivity > 100 uS/cm (PURE WATER MODE). | "}, - { 151 , ALARM_ID_DG_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE , "DG | Dial. Gen: Inlet Water Cond Low | Inlet water conductivity is low.\n- Treatment is paused.\n- Check the incoming water supply. | Inlet water conductivity too low | Inlet water conductivity < 200 uS/cm. Inlet water conductivity low disabled (PURE WATER MODE). | "}, - { 152 , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_LOW_RANGE , "DG | Dial. Gen: Inlet Water Pres Low | Inlet water pressure is low.\n- Treatment is paused.\n- Check the incoming water supply. | Inlet water pressure too low | Inlet water pressure < 25 PSI. | "}, - { 153 , ALARM_ID_HD_PRIME_COMPLETED_HIGH , "HD | Process: Pre-Tx Terminated | Pre-Treatment timeout.\n- Patient was not connected to device\n- Pre-Treatment has been terminated\n- Proceed to end treatment to remove cartridge from system. | HD prime completed high priority alarm | In Pre-Treatment Recirculation for 120 minutes (escalation of alarm 213) | "}, - { 154 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_LOW , "DG | Cleaning: Inlet Water Cond Low | Cleaning Mode Inlet water conductivity too low.\n- Cleaning mode process has terminated \n- Check inlet water before restarting cleaning mode. | Cleaning mode inlet water conductivity too low | Inlet water conductivity < 200 uS/cm. Inlet water conductivity low disabled (PURE WATER MODE). In cleaning mode | "}, - { 155 , ALARM_ID_HD_NEW_RESERVOIRS_DATA_MESSAGE_NOT_RECEIVE , "HD | Loss of DG Comm (Reservoir) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD No reservoir data message receive at least once every 2 seconds | No new reservoir data for 2 seconds. | "}, - { 156 , ALARM_ID_HD_DG_NEW_OPERATION_MODE_MESSAGE_NOT_RECEIVE , "HD | Loss of DG Comm (Op Mode) | Communication failure with Dialysis Generator.\n-Treatment must be terminated.\n- Ensure all cords are securely connected. | HD No DG op mode message receive at least once every 2 seconds | No DG op mode for 2 seconds. | "}, - { 157 , ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT , "DG | Cleaning: Chem Disinf PAA Prime | Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the \nbicarb port.\n- Check chemical disinfectant bottle is not empty. | Chemical disinfect priming the acid line timeout | If the disinfectant acid line is not primed within a certain period of time. | "}, - { 158 , ALARM_ID_DG_INLET_WATER_TEMPERATURE_IN_LOW_RANGE , "DG | Dial. Gen: Inlet Water Temp Low | Inlet water temperature is low.\n- Treatment is paused.\n- Check the incoming water supply. | Inlet water temperature low | Inlet temperature < 24 °C for 5 seconds. | "}, - { 159 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID , "DG | Cleaning: Chem Disinf Connect Cap | Remove chemical disinfectant connection and close cap. | Close concentrate line be able to flush it | Start of chemical disinfect flush. | "}, - { 160 , ALARM_ID_HD_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH , "HD | HD Fault: BP Rotor Max Speed | Call service to schedule a repair. | Blood pump rotor speed too high | If blood pump motor speed exceeded 100.0 RPM. | "}, - { 161 , ALARM_ID_DG_COMM_TOO_MANY_BAD_CRCS , "DG | DG Fault: HD-DG Comm | Call service to schedule a repair. | Too many bad CRCs detected on received system messages | If >= 5 bad CRCs detected on received CAN messages within 10 minutes. | "}, - { 162 , ALARM_ID_DG_FPGA_CLOCK_SPEED_CHECK_FAILURE , "DG | DG Fault: Proc-FPGA Clock | Call service to schedule a repair. | FPGA clock speed failure | If the FPGA clock speed is relatively close to the processor clock for a certain period of time. | "}, - { 163 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM , "HD | Dial. Gen: UF Rate Check | Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system\n(shock/vibration)\n- Check system is stable and level\n- Resume and If problem persists, call service to schedule a\nrepair. | HD sees primary load cell for reservoir 1 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, - { 164 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM , "HD | Dial. Gen: UF Rate Check | Ultrafiltration control detected and incorrect rate.\n- This can be caused by excessive movement of system \n(shock/vibration).\n- Check system is stable and level\n- Resume and If problem persists, call service to schedule a \nrepair. | HD sees primary load cell for reservoir 2 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, - { 165 , ALARM_ID_HD_TREATMENT_RINSEBACK_TIMEOUT_ALARM , "HD | Blood Stop: Blood Clot Risk | Blood pump has been off for too long.\n- Treament must be terminated. Blood clot risk.\n- NO RINSEBACK ALLOWED. | HD in treatment rinseback operation timeout | If the maximum time inrinseback operation has been exceeded. | "}, - { 166 , ALARM_ID_AVAILABLE_3 , " | | | | | "}, - { 167 , ALARM_ID_HD_CARTRIDGE_DOOR_OPENED , "HD | Blood Stop: Door Open | Device door is open.\n - Close door and press RESUME button to continue. | HD cartridge door opened alarm | If the cartridge door is opened as reported by the FPGA. | "}, - { 168 , ALARM_ID__AVAILABLE_70 , " | | | | | "}, - { 169 , ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE , "DG | DG Fault: Dialysate Flow Sens Rg | Call service to schedule a repair. | Dialysate flow rate out of range | If the dialysate flow rate > 2.00 L/min. | "}, - { 170 , ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY , "HD | Heparin Syringe Empty | Heparin syringe empty.\n- Treatment will continue\n- If additional heparin is required to complete treatment, \nadminister manually. | HD syringe empty alarm | If the syringe pump position is near empty position. | "}, - { 171 , ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION , "HD | Process: Pre-Tx Hep. Pump Occ. | Heparin pump occlusion detected.\n- Check heparin line is unclamped.\n- Check there are no kinks in the heparin line. | HD syringe pump occlusion alarm | If the pressure sensor voltage reading > SYRINGE_FORCE_OCCLUSION_THRESHOLD_V. | "}, - { 172 , ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM , "HD | Process: Pre-Tx Not Enough Hep. | Not enough heparin is available for treatment.\n- Check if syringe pump is touching syringe plunger.\n- If syringe pump is touching syringe plunger, end treatment.\n- If syringe pump is not touching syringe plunger, reload \nsyringe with enough heparin. | HD syringe pump not enough Heparin alarm | If the estimated syringe volume needed for treatment is not sufficient | "}, - { 173 , ALARM_ID_HD_RTC_CONFIG_ERROR , "HD | HD Fault: RTC Config | Call service to schedule a repair. | HD RTC configuration error | If the RTC configuration registers report an error. | "}, - { 174 , ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE , "HD | HD POST: HD RTC Timer | Call service to schedule a repair. | HD RTC vs. Timer accuracy error | If RTC and timer are not aligned on 1 second elapsed time. | "}, - { 175 , ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR , "HD | HD Fault: Pump Commutation Err | Call service to schedule a repair. | HD pump commutation error | If the set pump direction does not agree with the hall sensor direction. | "}, - { 176 , ALARM_ID_AVAILABLE_4 , " | | | | | "}, - { 177 , ALARM_ID_DG_SOFTWARE_FAULT , "DG | DG Fault: Software Invalid State | Call service to schedule a repair. | DG software fault. Software found itself in an unexpected state | If the specific software faults listed in alarm management SW faults has been detected | "}, - { 178 , ALARM_ID_HD_COMM_TIMEOUT , "UI | HD Fault: UI-Proc Comm | Call service to schedule a repair. | HD communication timeout | If the HD stops communicating with the UI. | "}, - { 179 , ALARM_ID_DG_FPGA_COMM_TIMEOUT , "DG | DG Fault: FPGA Com | Call service to schedule a repair. | DG FPGA communication down for too long | If retries for commands exceeds limit or FPGA reports comm error. | "}, - { 180 , ALARM_ID_DG_RO_FLOW_RATE_OUT_OF_MAX_RANGE , "DG | DG Fault: RO Flow Sensor Range | Call service to schedule a repair. | RO flow rate out of range | If the RO flow rate > 2.00 L/min. | "}, - { 181 , ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE , "DG | DG Fault: Tare Out of Range | Call service to schedule a repair. | DG load cells weight out of range for tare | If the load cell weight is out of range for tare. | "}, - { 182 , ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD , "DG | DG POST: LC Cal | Call service to schedule a repair. | DG load cells invalid calibration | If the CRC of load cells calibration data does not match the calculated CRC. | "}, - { 183 , ALARM_ID_DG_INVALID_LOAD_CELL_VALUE , "DG | Cleaning: Invalid Resv Transfer | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG invalid load cell value | If the half full reservoir is filled prior to filling the reservoir that is supposed to overflow to the half full reservoir. | "}, - { 184 , ALARM_ID_DG_INLET_UV_REACTOR_NOT_HEALTHY , "DG | DG Fault: UVi Error | Call service to schedule a repair. | Inlet reactor not healthy | If the inlet reactor are not healthy. | "}, - { 185 , ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE , "DG | DG Alarm (Low): Fan Speed | Fan failure.\n- Check that the fans inlets are not blocked or obstructed. | DG fan RPM out of range | If the fan RPM is out of Min/Max range. | "}, - { 186 , ALARM_ID_DG_CONCENTRATE_PUMP_FAULT , "DG | DG Fault: CP1/CP2 Fault | Call service to schedule a repair. | DG concentrate pump fault | If the concentrate pumps fault is reported by the FPGA. | "}, - { 187 , ALARM_ID_DG_CP1_SPEED_CONTROL_ERROR , "DG | DG Fault: CP1 Speed Fault | Call service to schedule a repair. | DG concentrate pump CP1 speed control error | If the concentrate pump CP1 speed > 0.02 tolerance for a certain period of time. | "}, - { 188 , ALARM_ID_DG_CP2_SPEED_CONTROL_ERROR , "DG | DG Fault: CP2 Speed Fault | Call service to schedule a repair. | DG concentrate pump CP2 speed control error | If the concentrate pump CP1 speed > 0.02 tolerance for a certain period of time. | "}, - { 189 , ALARM_ID_DG_DRAIN_PUMP_RPM_OUT_OF_RANGE , "DG | DG Fault: DRP Speed Fault | Call service to schedule a repair. | DG drain pump RPM out of range | If the drain pump RPM > 100.0 of the target RPM. | "}, - { 190 , ALARM_ID_DG_DRAIN_PUMP_OFF_FAULT , "DG | DG Fault: DRP Speed Not Off | Call service to schedule a repair. | DG drain pump off fault | If the pump is in off state and the RPM is greater than the minimum RPM of 300.0 RPM. | "}, - { 191 , ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE , "DG | DG Fault: RO Flow High | Call service to schedule a repair. | DG flow rate out of upper range | If the RO flow rate > 10% from the target flow rate. | "}, - { 192 , ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE , "DG | DG Fault: RO Flow Low | Call service to schedule a repair. | DG flow rate out of lower range | If the RO flow rate < 10% from the target flow rate. | "}, - { 193 , ALARM_ID_AVAILABLE_5 , " | | | | | "}, - { 194 , ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE , "DG | DG Fault: RO Driver Feedback | Call service to schedule a repair. | DG RO pump duty cycle out of range | If the DG RO pump duty cycle is out of range by 5% of the target duty cycle for a certain period of time. | "}, - { 195 , ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE , "DG | DG Fault: RO Pump High Pressure | Call service to schedule a repair. | DG RO pump pressure out of range | If the DG RO pump pressure > 135 psi for a certain period of time. | "}, - { 196 , ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT , "DG | DG Fault: CPi/CPo Comm | Call service to schedule a repair. | DG CPi/CPo conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "}, - { 197 , ALARM_ID_DG_CD1_CD2_SENSORS_FPGA_FAULT , "DG | DG Fault: CD1/CD2 Comm | Call service to schedule a repair. | DG CD1/CD2 conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "}, - { 198 , ALARM_ID_DG_RO_FLOW_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON , "DG | DG Fault: HP On With No Flow | Call service to schedule a repair. | DG primary heater while RO flow is low | If the RO flow is < 0.2 L/min for a certain period of time. | "}, - { 199 , ALARM_ID_DG_DIALYSATE_FLOW_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON , "DG | DG Fault: HR On With No Flow | Call service to schedule a repair. | DG trimmer heater while dialysate flow is low | If the FMD flow is ≤ 0 mL/min (raw) for a certain period of time. | "}, - { 200 , ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE , "DG | DG Fault: Thermistor Range | Call service to schedule a repair. | DG thermistor or temperature sensor out of range | If thermistor > 80.0 C or < 0.0 C. | "}, - { 201 , ALARM_ID_HD_PRE_TREATMENT_WET_FLOW_TEST_FAILURE , "HD | Process: Pre-Tx Wet Self-Test | Self-test has detected a problem in the dialysate flow \nmeasurement or there is a leak in the dialysate in/out lines.\n- The cartridge should be primed\n- Check cartridge installation on to machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. | HD pre-treatment wet flow test failure | If the pre-treatment wet flow test has failed. | "}, - { 202 , ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE , "HD | Process: Pre-Tx Dry Self-Test | Self-test has detected blood circuit pressure cannot be \nrelieved.\n- Check PBo connection to HD for kinks\n -Check PBo transducer protector for occlusion\n- If problem persists, install a new cartridge and \nPBo transducer protector. | HD pre-treatment dry pressure normal test failure | If the pre-treatment dry pressure normal test failed. | "}, - { 203 , ALARM_ID_AVAILABLE_6 , " | | | | | "}, - { 204 , ALARM_ID_DG_RO_REJECTION_RATIO_OUT_OF_RANGE , "DG | DG Fault: RO Rejection | Call service to schedule a repair. | RO rejection ratio out of range | If RO rejection ratio > 0.1 | "}, - { 205 , ALARM_ID_DG_CONDUCTIVITY_SENSOR_FAULT , "DG | DG Fault: Cond Sensors Error | Call service to schedule a repair. | Conductivity sensor fault | If conductivity sensor reports 0x11 for more than 2 consecutive reads. | "}, - { 206 , ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME , "DG | DG Fault: Reservoir Fill Timeout | Call service to schedule a repair. | DG dialysate fill runs out of time | If DG dialysate fill > 5 minutes. | "}, - { 207 , ALARM_ID_DG_FLOW_METER_CHECK_FAILURE , "DG | DG Fault: FMP Flow Rate Error | Call service to schedule a repair. | DG flow meter check failure alarm | If integrated Volume To Load Cell Reading Percent > 0.1. | "}, - { 208 , ALARM_ID_HD_VENOUS_LINE_OCCLUSION , "HD | Blood Stop: Venous Pres. High | Venous pressure is high.\n- Check for access or patient discomfort.\n- Resolve access issue if applicable.\n- Check that there are no kinks or clots in the tubing.\n- Unkink the lines if applicable.\n- End treatment and do not return blood if clots are present. | HD venous line occlusion fault | If the venous pressure is > set limit + 50 mmHg if HD is in treatment or pre-treatment mode. | "}, - { 209 , ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT , "DG | Cleaning: Flush Circ Error | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG drain circulation line timeout | If the integrated volume < 0.1 for more than 60 secs. | "}, - { 210 , ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED , "HD | HD Alarm (Low): Battery Fault | Call service to schedule a repair. | HD battery pack detected an error | If the battery pack status error is detected from the slave device I2C address 0x0B. | "}, - { 211 , ALARM_ID_HD_BLOOD_SITTING_WARNING , "HD | Blood Stopped: Warning | Blood pump is stopped.\n- Resume treatment before countdown timer expires. | Blood sitting too long warning (> 4 min) | During treatment stop sub-mode, if the blood is in the line for more than 4 minutes. | "}, - { 212 , ALARM_ID_HD_END_OF_TREATMENT_ALARM , "HD | Blood Stopped: Warning | Blood pump is stopped.\n- Resume treatment before countdown timer expires. | Blood sitting too long warning (> 4 min) | During treatment end paused state, if the blood is in the line for more than 4 minutes. | "}, - { 213 , ALARM_ID_HD_PRIME_COMPLETED_MEDIUM , "HD | Process: Pre-Tx Prime Complete | Prime of the cartridge is complete.\n- Proceed to connect to patient. | HD prime completed medium priority alarm | In Pre-Treatment Recirculation for 90 minutes (escalation of alarm 226) | "}, - { 214 , ALARM_ID_AVAILABLE_30 , " | | | | | "}, - { 215 , ALARM_ID_AVAILABLE_31 , " | | | | | "}, - { 216 , ALARM_ID_HD_END_TREATMENT_TIMEOUT_ALARM , "HD | Process: End of Dialysis Tx | Dialysis Treatment has completed\n- Proceed to end treatment and rinseback. | HD end treatment sub-mode timeout alarm | If the treatment ended successfully. | "}, - { 217 , ALARM_ID_AVAILABLE_32 , " | | | | | "}, - { 218 , ALARM_ID_HD_SYRINGE_DETECTED , "HD | Process: Remove Syringe | Syringe not removed from machine.\n- Remove heparin syringe. | HD syringe detected alarm | If the syringe detection switch > 2.0 volts. | "}, - { 219 , ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED , "HD | Blood Stop: Syringe Not Detected | Heparin is needed for treatment but syringe has been removed \nfrom syringe pump.\n- Install Heparin syringe. | HD syringe pump syringe removed alarm | If the syringe detection switch < 2.0 volts. | "}, - { 220 , ALARM_ID_DG_THD_SENSORS_FPGA_FAULT , "DG | DG Fault: THD RTD Comm | Call service to schedule a repair. | DG THd sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 221 , ALARM_ID_HD_EMPTY_SALINE_BAG , "HD | Blood Stop: Saline Bag Empty | Saline bag appears empty.\n- Check saline bag and line and replace if saline bag is \nempty. | HD Saline bag is empty | If the measured arterial pressure < -300.0 mmHg for more than 250 msec. | "}, - { 222 , ALARM_ID_HD_OCCLUSION_SENSOR_FPGA_FAULT , "HD | HD Fault: BP Occ Com | Call service to schedule a repair. | HD occlusion sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, - { 223 , ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT , "HD | HD Fault: Art. Pres. Com | Call service to schedule a repair. | HD arterial sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 224 , ALARM_ID_HD_TREATMENT_STOPPED_BY_USER , "HD | Blood Stopped: Treatment Pause | Treatment paused by user. | Treatment stopped by user action - pressed stop button | If the user has pressed the stop button. | "}, - { 225 , ALARM_ID_HD_END_OF_TREATMENT_WARNING , "HD | Process: End of Treatment | Dialysis Treatment has completed\n- Proceed to end treatment and rinseback. | HD end of treatment warning | If the treatment duration has exceeded the prescribed treatment time entered by the user. | "}, - { 226 , ALARM_ID_HD_PRIME_COMPLETED_LOW_PRIORITY , "HD | Process: Pre-Tx Priming Complete | Prime of the cartridge is complete.\n- Proceed to connect to patient. | HD prime completed low priority alarm | Start of Pre-Treatment Recirculation - notifiy user to proceed to patient connection | "}, - { 227 , ALARM_ID_AVAILABLE_15 , " | | | | | "}, - { 228 , ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT , "HD | Process: Pre-Tx Prime Timeout | Blood line prime with saline timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. | HD time out on prime sub-mode purge air state. | During the pre-treatment prime state, if the prime saline purge air state exceeded 60 secs. | "}, - { 229 , ALARM_ID_HD_PRIME_DIALYSATE_DIALYZER_TIME_OUT , "HD | Process: Pre-Tx Prime Timeout | Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. | HD prime dialysate dialyzer time out alarm | If the priming of the dialyzer dialysate flow path has exceeded the time limit. | "}, - { 230 , ALARM_ID_HD_PRIME_DIALYSATE_BYPASS_TIME_OUT , "HD | Process: Pre-Tx Prime Timeout | Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. | HD prime dialysate bypass time out alarm | If the priming of the dialyzer bypass flow path has exceeded the time limit. | "}, - { 231 , ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE , "HD | Process: Pre-Tx Dry Self-Test | Self-test has detected a leak in the circuit\n- Check blood line connections\n- Check dialysate line connections\n- Check PBo and PBa transducer protectors for occlusion.\n- Check clamps.\n- If problem persists, install a new cartridge. | HD pre-treatment mode dry self-tests failure | If the following dry self tests have failed: 1. handleDrySelfTestPressureSensorsState 2. handleDrySelfTestPressureSensorsNormalState | "}, - { 232 , ALARM_ID_HD_PRE_TREATMENT_WET_LC_TEST_FAILURE , "HD | Process: Pre-Tx Wet Self-Test | Self-test has detected a problem in the load cell \nmeasurement or there is a leak in the dialysate in/out lines\n- The cartridge should be primed\n- Check cartridge installation onto machine\n- If problem persists, terminate pre-treatment and restart \nwith a new cartridge. | HD pre-treatment mode wet self-tests failure | If the following wet self tests have failed: 1. handleWetSelfTestPrimeCheckState 2. handleWetSelfTestFirstDisplacementVerifyState 3. handleWetSelfTestSecondDisplacementVerifyState | "}, - { 233 , ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC , "DG | DG Fault: Baro Cal CRC | Call service to schedule a repair. | DG barometric pressure sensor bad coefficients CRC | If the following happens: 1. The stored CRC in the sensor does not match the calculated CRC. 2. The CRC and coefficients have not been received from the sensor after 20 seconds from the power up. | "}, - { 234 , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_HIGH_RANGE , "DG | Dial. Gen: Inlet Water Pres High | Inlet water pressure is high.\n- Treatment is paused\n- Check the incoming water supply. | DG inlet water pressure is too high | If the inlet water pressure is > 80 psig. | "}, - { 235 , ALARM_ID_HD_TREATMENT_STOPPED_AFTER_RINSEBACK , "HD | Process: Rinseback Complete | Rinseback has been completed. | HD in treatment stopped sub-mode after rinseback completed (no escalation) | If there is no active alarm and rinseback has completed. | "}, - { 236 , ALARM_ID_HD_INSTALL_NEW_CARTRIDGE , "HD | Process: Pre-Tx Dry Self-Test | Self-test has detected fluid in the cartridge.\n- Cartridges are single-use only\n- Install new cartridge to resume. | HD needs new cartridge to be installed | If the air trap sensor reported AIR and bubble sensor detected bubbles. | "}, - { 237 , ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Process: Pre-Tx Prime Timeout | Dialyzer prime timeout.\n- Check blood and dialysate lines for clamps, kinks or leaks. | HD prime saline dialyzer time out alarm | If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "}, - { 238 , ALARM_ID_HD_NO_CARTRIDGE_LOADED , "HD | Process: Pre-Tx Dry Self-Test | Self-test has detected cartridge is not installed.\n- Check that a cartridge is properly installed. | HD no cartridge loaded or installed improperly alarm | If the measured blood pump occlucsion pressure reading is < 5000 or > 24500. | "}, - { 239 , ALARM_ID_HD_CARTRIDGE_REMOVAL_FAILURE , "HD | Process: Post-Tx Remove Cartridge | Cartridge not unloaded, or unloaded improperly.\n- Check that the cartridge has been removed. | HD fail to remove cartridge alarm | In the post treatment state, if the cartridge has not been removed. | "}, - { 240 , ALARM_ID_DG_BICARB_CONDUCTIVITY_OUT_OF_RANGE , "DG | Dial. Gen: Bicarb Conc. Cond. | Bicarbonate conductivity during prime is out of range.\n- Check correct concentrate is connected and full.\n- Resume to reprime concentrate. | Bicarb conductivity out of range during bicarb pump check alarm | If the conductivity value for bicarbonate concentrate is out of range for more than 45 secs. | "}, - { 241 , ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT , "DG | Cleaning: Resv Drain Timeout | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG reservoir drain time out | If the DG reservoir drain is not complete in 120 secs. | "}, - { 242 , ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT , "DG | Cleaning: Resv Fill Timeout | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG reservoir fill time out | If the DG reservoir fill is not complete in 120 secs. | "}, - { 243 , ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT , "DG | Cleaning: Fluid Loss Detected | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG reservoir leak time out | If the reservoir level is drifted by 100 mL for more than 30 seconds. | "}, - { 244 , ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE , "DG | Cleaning: Temp Sensor Check | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG temperature sensors difference out of range | If any of the temperature sensors are out of the average of the sensors by more than 3 C. | "}, - { 245 , ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT , "DG | Cleaning: Heat Disinfect Temp TO | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG heat disinfect target temperature time out (could not reach to temperature) | If heating up to minimum temperature for heat disinfect failed after 4 hours. | "}, - { 246 , ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE , "DG | Cleaning: RO Water Cond Error | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG chemical disinfect inlet conducitivty out of range | If CPo and CD2 conductivity values are above 100 uS/cm. | "}, - { 247 , ALARM_ID_AVAILABLE_7 , " | | | | | "}, - { 248 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE , "DG | Cleaning: Chem Disinfect Proc | Cleaning mode process terminated unexpectedly.\n-Restart cleaning mode.\n-If problem persists, call service to schedule a repair. | DG chemical disinfect out of target temperature | If TPo > 50 C after 1 second. | "}, - { 249 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE , "DG | Cleaning: Chem Disinf PAA Cond | Unable to sense proper chemical disinfectant.\n- Cleaning mode process has terminated.\n- Check that proper chemical disinfectant is connected to the \nbicarb port.\n- Check chemical disinfectant bottle is not empty. | DG chemical disinfect out of target conductivity | If CD2 < 150 uS/cm or CD2 > 650 uS/cm after 10 seconds. | "}, - { 250 , ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID , "DG | Cleaning: Chem Disinf Connect PAA | Connect chemical disinfectant bottle to bicarb port. | Insert the acid to start chemical disinfect | Start of chemical disinfect | "}, - { 251 , ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC , "HD | HD POST: Sys Rec NVRAM CRC | Call service to schedule a repair. | HD invalid system record | If the calculated CRC of the HD system record image does not match the expected CRC. | "}, - { 252 , ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC , "HD | HD POST: Serv Rec NVRAM CRC | Call service to schedule a repair. | HD invalid service record | If the calculated CRC of the HD service record image does not match the expected CRC. | "}, - { 253 , ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC , "DG | DG POST: Sys Rec NVRAM CRC | Call service to schedule a repair. | DG invalid system record | If the calculated CRC of the DG system record image does not match the expected CRC. | "}, - { 254 , ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC , "DG | DG POST: Serv Rec NVRAM CRC | Call service to schedule a repair. | DG invalid service record | If the calculated CRC of the DG service record image does not match the expected CRC. | "}, - { 255 , ALARM_ID_HD_UI_COMPATIBILITY_ERROR , "HD | HD POST: UI Compatibility | Call service to schedule a repair. | HD and UI software builds are not compatible | If the compatibility revision field of the UI is not equal to SW_COMPATIBILITY_REV. | "}, - { 256 , ALARM_ID_HD_DISINFECT_CHEM_FLUSH , "HD | Cleaning: Chem Flush In Progress | Chemical disinfect flush in progress\n- Please wait for the process to complete\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. | DG flush started | If DG flush successfully started from the UI. | "}, - { 257 , ALARM_ID_AVAILABLE_8 , " | | | | | "}, - { 258 , ALARM_ID_AVAILABLE_9 , " | | | | | "}, - { 259 , ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE , "HD | HD Fault: Temp Sensors Error | Call service to schedule a repair. | HD temperatures out of range | If thermistor reports temperature > 80.0 C or < 0.0 C for a certain period of time. | "}, - { 260 , ALARM_ID_HD_UI_POST_FAILURE_SHASUM , "UI HD | HD POST: UI Image | Call service to schedule a repair. | UI POST Application Integrity (Sha256Sum) failure | If the UI POST reports a shasum faillure. | "}, - { 261 , ALARM_ID_HD_UI_POST_FAILURE_CANBUS , "UI HD | HD POST: UI CAN Driver | Call service to schedule a repair. | UI POST CANBus failure | If the UI POST reports a can bus failure. | "}, - { 262 , ALARM_ID_HD_UI_POST_FAILURE_DISPLAY , "UI HD | HD POST: UI Disp Driver | Call service to schedule a repair. | UI POST Display failure | If the UI POST reports a display failure. | "}, - { 263 , ALARM_ID_HD_UI_POST_FAILURE_TOUCH , "UI HD | HD POST: UI Touch Driver | Call service to schedule a repair. | UI POST Touch failure | If the UI POST reports a touch failure. | "}, - { 264 , ALARM_ID_HD_UI_POST_FAILURE_SDCARD , "UI HD | HD POST: UI SD-Card | SD-Card Failure \n- Power cycle the system.\n- Call service to schedule a repair if problem persists. | UI POST SD-Card failure | If the UI POST reports SD card failure. | "}, - { 265 , ALARM_ID_HD_UI_POST_FAILURE_RTC , "UI HD | HD POST: UI RTC | Call service to schedule a repair. | UI POST RTC failure | If the UI POST reports RTC failure. | "}, - { 266 , ALARM_ID_HD_UI_POST_FAILURE_WIFI , "UI HD | HD POST: UI WiFi | Call service to schedule a repair. | UI POST WiFi failure | If the UI POST reports WiFi failure. | "}, - { 267 , ALARM_ID_HD_UI_POST_FAILURE_BLUETOOTH , "UI HD | HD POST: UI Bluetooth | Call service to schedule a repair. | UI POST Bluetooth failure | If the UI POST reports bluetooth failure. | "}, - { 268 , ALARM_ID_HD_UI_POST_FAILURE_ETHERNET , "UI HD | HD POST: UI Ethernet | Call service to schedule a repair. | UI POST Ethernet failure | If the UI POST reports ethernet failure. | "}, - { 269 , ALARM_ID_HD_UI_POST_FAILURE_SOUND , "UI HD | HD POST: UI Sound | Call service to schedule a repair. | UI POST Sound failure | If the UI POST reports sound failure. | "}, - { 270 , ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED , "HD | HD POST: Proc Safestate | Call service to schedule a repair. | HD POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, - { 271 , ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED , "DG | DG POST: Proc Safestate | Call service to schedule a repair. | DG POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, - { 272 , ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE , "HD | HD Alarm (Low): Fan Speed | Fan failure.\n- Check that the fans inlets are not blocked or obstructed. | HD Fan RPM out of range | If the fan RPM is out of Min/Max range. | "}, - { 273 , ALARM_ID_AVAILABLE_10 , " | | | | | "}, - { 274 , ALARM_ID_AVAILABLE_11 , " | | | | | "}, - { 275 , ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE , "HD | HD Fault: Arterial Press Range | Call service to schedule a repair. | HD arterial pressure sensor is reading out of range | If the arterial pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, - { 276 , ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE , "HD | HD Fault: Venous Press Range | Call service to schedule a repair. | HD venous pressure sensor is reading out of range | If the venous pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, - { 277 , ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE , "HD | HD Fault: Occlusion Sens Range | Call service to schedule a repair. | HD BP occlusion sensor is reading out of range | If the blood pump occlusion count is < 2000. | "}, - { 278 , ALARM_ID_HD_ACTIVE_RESERVOIR_WEIGHT_OUT_OF_RANGE , "HD | DG Fault: Reservoir Overfill | Call service to schedule a repair. | HD active reservoir weight out of range. | If the active reservoir weight is > 1900.0 g. | "}, - { 279 , ALARM_ID_DG_DIALYSATE_DRAIN_TIME_OUT , "DG | DG Fault: Reservoir Drain | Call service to schedule a repair. | DG dialysate drain time out | If the DG dialysate drain exceeded 120 seconds. | "}, - { 280 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_INVALID , "DG | DG Fault: DRP Direction Fault | Call service to schedule a repair. | DG drain pump invalid direction | If the drain pump's direction is not 1 when draining. | "}, - { 281 , ALARM_ID_DG_ACID_BOTTLE_LOW_VOLUME , "DG | Dial. Gen: Acid Conc. Low | Acid concentrate low.\n- Replace acid concentrate bottle. | DG Acid concentration bottle low volume alarm | If the acid concentration bottle volume > 3240 (3340 - 100). | "}, - { 282 , ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME , "DG | Dial. Gen: Bicarb Conc. Low | Bicarbonate concentrate low.\n- Replace bicarbonate concentrate bottle. | DG Bicarbonate concentration bottle low volume alarm | If the bicarbonate concentration bottle volume > 3680 (3780 - 100). | "}, - { 283 , ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE , "DG | DG Fault: LC Range | Call service to schedule a repair. | DG load cells weight out of range | If the weight of the DG load cells > 4500.0 g or < 0.0 g. | "}, - { 284 , ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "DG | DG Fault: Redundant LC Check | Call service to schedule a repair. | DG load cells primary/back up drift out of range | If redundant load cells deviate by more than 60g after tare for 5 seconds. | "}, - { 285 , ALARM_ID_AVAILABLE_12 , " | | | | | "}, - { 286 , ALARM_ID_DG_CONCENTRATE_CAP_NOT_IN_PROPER_POSITION , "DG | Cleaning: Conc Cap Removed | Concentrate cap removed from DG during cleaning.\n- Cleaning Process Terminated. | DG cap in wrong state | If the concentrate cap is not in the right position in the cleaning modes. | "}, - { 287 , ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE , "HD | HD Fault: Proc-FPGA Clock | Call service to schedule a repair. | HD processor clock speed checks against FPGA clock failure | If during initialization mode, the difference between the processor clock speed and the FPGA clock speed > 1. | "}, - { 288 , ALARM_ID_HD_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "HD | DG Fault: LC Drift Check | Call service to schedule a repair. | HD load cell inconsistency | If redundant load cells deviate from start to end of a reservoir use during treatment by more than 10g. | "}, - { 289 , ALARM_ID_DG_DIALYSATE_CAP_NOT_IN_PROPER_POSITION , "DG | Cleaning: Dialysate Cap Removed | Dialysate cap removed from DG during cleaning.\n- Cleaning Process Terminated. | DG cap in wrong state | If the dialysate cap is not in the right position in the cleaning modes. | "}, - { 290 , ALARM_ID_HD_VENOUS_SENSOR_FPGA_FAULT , "HD | HD Fault: Ven. Pres. Com | Call service to schedule a repair. | HD venous sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 291 , ALARM_ID_HD_DISINFECT_FLUSH , "HD | Cleaning: Flush In Progress | System flush in progress\n- Please wait for the process to complete.\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. | DG flush started | If DG flush successfully started from the UI. | "}, - { 292 , ALARM_ID_HD_DISINFECT_HEAT , "HD | Cleaning: Heat Disinf In Progress | Heat disinfect in progress\n- Please wait for the process to complete.\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. | DG heat disinfect started | If DG heat disinfect successfully started from the UI. | "}, - { 293 , ALARM_ID_HD_DISINFECT_CHEM , "HD | Cleaning: Chem Disinf In Progress | Chemical disinfect in progress\n- Please wait for the process to complete.\n- Treatment will not be able to be started until process \ncompletes.\n- Process may be terminated by pressing the HD stop button. | DG chemical disinfect started | If DG chemical disinfect successfully started from the UI. | "}, - { 294 , ALARM_ID_AVAILABLE_13 , " | | | | | "}, - { 295 , ALARM_ID_HD_UI_POST_FAILURE_CLOUDSYNC , "UI HD | HD POST: UI CloudSync | Call service to schedule a repair. | UI cloud sync POST failure | If the UI POST reports cloud sync failure. | "}, - { 296 , ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT , "DG | DG Fault: TDi RTD Comm | Call service to schedule a repair. | DG TDi sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 297 , ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT , "DG | DG Fault: TRo RTD Comm | Call service to schedule a repair. | DG TRo sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 298 , ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT , "DG | DG Fault: Baro Pres Comm | Call service to schedule a repair. | DG barometric sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, - { 299 , ALARM_ID_DG_INVALID_SERIAL_NUMBER , "DG | DG POST: Serial Number Check | Call service to schedule a repair. | DG invalid serial number | If the DG serial number is empty and does not have any characters. | "}, - { 300 , ALARM_ID_HD_INVALID_SERIAL_NUMBER , "HD | HD POST: Serial Number Check | Call service to schedule a repair. | HD invalid serial number | If the HD serial number is empty and does not have any characters. | "}, - { 301 , ALARM_ID_AVAILABLE_14 , " | | | | | "}, - { 302 , ALARM_ID_DG_CPU_RAM_ERROR , "DG | DG Fault: Processor RAM error | Call service to schedule a repair. | DG_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 303 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT , "DG | DG Fault: DRP Hall Commutation | Call service to schedule a repair. | DG drain pump direction FPGA fault | If the FPGA indicates an error for a certain period of time. | "}, - { 304 , ALARM_ID_HD_INVALID_USAGE_RECORD_CRC , "HD | HD POST: Usage Rec NVRAM CRC | Call service to schedule a repair. | HD invalid usage reocord | If the CRC of the HD usage record does not match the calculated CRC. | "}, - { 305 , ALARM_ID_HD_CPU_RAM_ERROR , "HD | HD Fault: Processor RAM error | Call service to schedule a repair. | HD_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, - { 306 , ALARM_ID_DG_CD1_CD2_CHECK_FAULT , "DG | DG Fault: CD1 CD2 Check | Call service to schedule a repair. | | CD1 and CD2 conductivity measurement during acid check is not within 5% of each other | "}, - { 307 , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT , "HD | Blood Stop: Loss of AC Power | HD power has been lost. \n- Treatment must be terminated.\n-Check all electrical connections.\n- The display and CPU will run off of the battery until \npower returns.\n-If power is returned prior to blood stopped countdown elapses, \nrinseback will be allowed. | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, - { 308 , ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR , "DG | DG Fault: CPi Comm | Call service to schedule a repair. | DG CPi conductivity sensor transmits invalid characters | If the CPi conductivity sensor transmits invalid characters for a certain period of time. | "}, - { 309 , ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR , "DG | DG Fault: CPo Comm | Call service to schedule a repair. | DG CPo conductivity sensor transmits invalid characters | If the CPo conductivity sensor transmits invalid characters for a certain period of time. | "}, - { 310 , ALARM_ID_DG_CD1_COND_SENSOR_INVALID_CHAR , "DG | DG Fault: CD1 Comm | Call service to schedule a repair. | DG CD1 conductivity sensor transmits invalid characters | If the CD1 conductivity sensor transmits invalid characters for a certain period of time. | "}, - { 311 , ALARM_ID_DG_CD2_COND_SENSOR_INVALID_CHAR , "DG | DG Fault: CD2 Comm | Call service to schedule a repair. | DG CD2 conductivity sensor transmits invalid characters | If the CD2 conductivity sensor transmits invalid characters for a certain period of time. | "}, - { 312 , ALARM_ID_HD_DIAL_IN_FLOW_CHECK_FAILURE , "HD | Dial. Gen: Dialysate In Flow | Dialysate in flow rate is low\n- Check dialysate line connection to the DG. | The dialysate inlet flow is too low. | If the dialysate inlet flow < 10 mL/min (raw) while in treatment mode or pre-treatment mode after prime and DPi is running. | "}, - { 313 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_LOW , "DG | Cleaning: Inlet Water Temp Low | Cleaning Mode Inlet water temperature too low.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. | DG cleaning mode inlet water temperature too low | If inlet water temperature is < 24 C. | "}, - { 314 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_HIGH , "DG | Cleaning: Inlet Water Press High | Cleaning Mode Inlet water pressure too high.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. | DG cleaning mode inlet water pressure too high | If inlet water temperature is > 80 psig. | "}, - { 315 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW , "DG | Cleaning: Inlet Water Press Low | Cleaning Mode Inlet water pressure too low.\n- Cleaning mode process has terminated.\n- Check inlet water before restarting cleaning mode. | DG cleaning mode inlet water pressure too low | If inlet water pressure is < 14 psig. | "}, - { 316 , ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT , "DG | DG Fault: Acid CP Pump Park | Call service to schedule a repair. | Acid concentrate pump did not park successfully | If the park took more than 1 second. | "}, - { 317 , ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT , "DG | DG Fault: Bicarb CP Pump Park | Call service to schedule a repair. | Bicarb concentrate pump did not park successfully | If the park took more than 1 second. | "}, - { 318 , ALARM_ID_HD_AIR_PUMP_TIMEOUT , "HD | HD Fault: Air Pump Timeout | Unable to reduce fluid level.\n- Air trap may be overfilled.\n- Pressure transducer protector may be contaminated.\n- Treatment must be terminated without option for rinseback.\n- Call service to schedule a repair. | HD Air Pump operation timeout | If air pump has been turned on for greater than 10s. | "}, - { 319 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE , "DG | Cleaning: Chem Residual Sampling | Collect chemical residuals water sample from drain line. | Collect sample to check the chemical disinfectant acid | Chemical disinfect flush sample alarm is prompted. | "}, - { 320 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT , "DG | Cleaning: Chem Residual Timeout | During Chemical Disinfection Flush\n-user residual sampling timed out. | The user did not proceed with collecting chemical disinfect flush sample for more than 30 minutes | Chemical disinfect flush sample was not collected form more than 30 minutes. | "}, - { 321 , ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY , "DG | DG Fault: UVo Error | Call service to schedule a repair. | Outlet reactor not healthy | If the outlet reactor are not healthy. | "}, // Num Alarm ID Device Display Title Instructions Description Trigger Condition - { 322 , ALARM_ID_HD_UI_POST_FAILURE_INVALID_YEAR , "UI HD | HD POST Alarm: UI Invalid Year | Call service to schedule a repair. | UI POST Invalid Year | If the UI POST reports a invalid year. | "}, + { 0 , ALARM_ID_NO_ALARM , "N/A | | \n\n | Indication for when no alarms is a possible situation | N/A | "}, + { 1 , ALARM_ID_HD_STUCK_BUTTON_TEST_FAILED , "HD | Stuck Button | A button was pressed during start up and appears stuck. \n-Press and release the power and stop buttons on the front of the device. \n-Turn device off, then back on. \n-If problem continues, call service to schedule a repair. \n\nHD POST: Stuck Button | Stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up | Stop or Off button are pressed for more than 1 sec during POST. | "}, + { 2 , ALARM_ID_HD_FPGA_POST_TEST_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: FPGA Compatibility | HD FPGA POST failure | Minimum HD FPGA major revision is not compatible with this version of HD firmware or the FPGA Id is not correct. | "}, + { 3 , ALARM_ID_DG_FPGA_POST_TEST_FAILED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: FPGA Compatibility | DG FPGA POST failure | Minimum DG FPGA major and minor revision are not equal to the FPGA major and minor revision in FPGA header | "}, + { 4 , ALARM_ID_HD_WATCHDOG_POST_TEST_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: WD Safestate | HD Watchdog POST failure | If the following are not observed after 500ms of not petting the WD: 1. WD exp pin=low 2. 24V <= 5V 3. audio current >= 200mA If the following are not observed after 500ms of resumed WD petting at proper timing: 1. WD exp pin=high 2. 24V >= 22.6V 3. audio current <= 10 mA | "}, + { 5 , ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: WD Safestate | DG Watchdog POST failure | If the following are not observed after 500ms of not petting the WD: 1. WD exp pin=low 2. 24V <= 5V If the following are not observed after 750ms of resumed WD petting at proper timing: 1. WD exp pin=high 2. 24V >= 22.6V | "}, + { 6 , ALARM_ID_HD_UI_COMM_POST_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Proc-UI Comm | UI communication POST failure. UI failed to communicate within a reasonable time after power up | If the UI failed to checkin via the CAN bus within 40 seconds | "}, + { 7 , ALARM_ID_HD_RTC_BATTERY_LOW , "HD | Service Required: Hemodialysis Device | A non-critical problem was detected with the hemodialysis device.\n-Call service to report the issue and schedule a repair.\n\nHD Alarm (Low): RTC Bat Low | Real-time clock configuration error | If the RTC is not functional as indicated by the bits in the first 3 control registers. | "}, + { 8 , ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Acc Vector | HD accelerometer failed POST | If the calculated vector length of the accelerometer x, y, z is not the nominal length. | "}, + { 9 , ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Acc Vector | DG accelerometer failed POST | If the calculated vector length of the accelerometer x, y, z is not the nominal length. | "}, + { 10 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_EMBEDDED_MODE_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: BLD Config Emb Mode | HD blood leak sensor embedded mode communication failed | If the blood leak sensor embedded mode is unresponsive. | "}, + { 11 , ALARM_ID_HD_DIALYSATE_TEMP_BELOW_TARGET_TEMP , "HD | Low Dialysate Temperature | Dialysate temperature is low. \n-Treatment is currently paused.\n-When the temperature is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Dialysate Temp Low | Dialysate temperature is below the target temperature | If the dialysate temperature is below the target temperature for a certain period of time. | "}, + { 12 , ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: HD Image | HD firmware image integrity POST test failed | If the calculated CRC of the HD image does not match the expected CRC. | "}, + { 13 , ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: DG Image | DG firmware image integrity POST test failed | If the calculated CRC of the DG firmware image does not matched the expected CRC | "}, + { 14 , ALARM_ID_DG_INVALID_USAGE_RECORD_CRC , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Usage Rec NVRAM CRC | DG non-volatile usage information group invalid record CRC | If the DG usage information record's CRC does not match the calculated CRC in POST. | "}, + { 15 , ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_SAFETY_TEMP , "HD | High Dialysate Temperature | Dialysate temperature is high. \n-Treatment is currently paused.\n-When dialysate temperature is within target range,\n treatment will need to be resumed.\n\nDial. Gen: Dialysate Temp High | Dialysate temperature is out of high safety range | If the dialysate temperature is > 46 C for a certain period of time. | "}, + { 16 , ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Primary Alarm Current | HD alarm audio failed POST | If alarm audio current is NOT in expected range for than 1 second while alarm tone is being output | "}, + { 17 , ALARM_ID_HD_UI_POST_TIMEOUT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI POST Not Complete | HD UI POST failed | If UI reports POST failed but did not trigger fault OR UI has not sent POST results within 2 seconds. | "}, + { 18 , ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_BY_DG , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (DG ACK) | HD to DG comm error. | HD message to DG that requires acknowledge was not acknowledged within a certain time. | "}, + { 19 , ALARM_ID_HD_DIALYSATE_TEMP_ABOVE_TARGET_TEMP , "HD | High Dialysate Temperature | Dialysate temperature is high. \n-Treatment is currently paused.\n-When dialysate temperature is within target range,\n treatment will need to be resumed. \n\nDial. Gen: Dialysate Temp High | Dialysate temperature is above the target temperature | If the dialysate temperature is above the target temperature for a certain period of time. | "}, + { 20 , ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Conductivity Cal | DG conductivity sensors invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, + { 21 , ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Drain Line Vol Cal | DG drain line volume invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, + { 22 , ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Reservoir Vol Cal | DG reservoirs invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, + { 23 , ALARM_ID_DG_ACID_CONCENTRATE_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Acid Conc Cal | DG acid concentrate calibration record | If the non-volatile data is valid and if not raise the alarm | "}, + { 24 , ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Bicarb Conc Cal | DG bicarb concentrate calibration record | If the non-volatile data is valid and if not raise the alarm | "}, + { 25 , ALARM_ID_DG_ACCELEROMETERS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Acc Cal | DG accelerometer invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, + { 26 , ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Acc Cal | HD accelerometer invalid calibration record | If the accel calibration data that was received from NVDataMgmt is NOT legitimate. | "}, + { 27 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED , "HD | Self Test: Blood Leak | A problem has been detected with the blood leak sensor.\n- Confirm cartridge is properly installed.\n- If problem persists, terminate treatment preparation and \n begin again using a new cartridge.\n\nProcess: Pre-Tx Wet Self-Test | HD BLD sensor failed zero sequence | BLD fails to complete zero sequence. | "}, + { 28 , ALARM_ID_DG_TWO_WIRE_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Conductivity RTD Comm | DG two wire sensors FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 29 , ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: SP DAC Cal | HD heparin force sensor invalid calibration record | If the heparin force sensor calibration data that was received from NVDataMgmt is NOT legitimate. | "}, + { 30 , ALARM_ID_HD_SOFTWARE_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: SW Invalid State | HD Software fault. Software found itself in an unexpected state | If the specific software faults listed in alarm management SW faults has been detected | "}, + { 31 , ALARM_ID_HD_BLOOD_PUMP_MC_CURRENT_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Current | Blood pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the measured MC current is not greater than BP_MAX_CURR_WHEN_STOPPED_MA or is not greater than BP_MAX_CURR_WHEN_RUNNING_MA. | "}, + { 32 , ALARM_ID_HD_BLOOD_PUMP_OFF_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Speed | Blood pump failed motor off check. Measured speed while commanded off | If the measured motor speed is greater than BP_MAX_MOTOR_SPEED_WHILE_OFF_RPM | "}, + { 33 , ALARM_ID_HD_BLOOD_PUMP_MC_DIRECTION_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Direction | Blood pump failed motor direction check. Measured vs. commanded | If the set direction versus hall sensors direction versus sign of motor speed DOES NOT agree. | "}, + { 34 , ALARM_ID_HD_BLOOD_PUMP_ROTOR_SPEED_CHECK , "HD | Blood Pump Error | A problem has been detected with the blood pump.\n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue.\n\nHD Fault: BP Rotor | Blood pump failed rotor speed check. Mismatch with rotor and motor speeds | If the delta of the measured motor speed and the commanded motor speed is not within tolerance. | "}, + { 35 , ALARM_ID_HD_DIAL_IN_PUMP_MC_CURRENT_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPi Current | Dialysis inlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the Motor Controller measured DPi pump current > 150.0 mA for more than 250.0 msec. | "}, + { 36 , ALARM_ID_HD_DIAL_IN_PUMP_OFF_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPi Speed | Dialysis inlet pump failed motor off check. Measured speed while commanded off | If during command off state, the DPi pump motor speed is measured > 100.0 RMP. | "}, + { 37 , ALARM_ID_HD_DIAL_IN_PUMP_MC_DIRECTION_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPi Direction | Dialysis inlet pump failed motor direction check. Measured vs. commanded | If the set direction versus hall sensors direction DO NOT agree for more than 250.0 msec. | "}, + { 38 , ALARM_ID_HD_DIAL_IN_PUMP_ROTOR_SPEED_CHECK , "HD | Dialysate Pump Error | A problem has been detected with the dialysate pump.\n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue.\n\nHD Fault: DPi Rotor | Dialysis inlet pump failed rotor speed check. Mismatch with rotor and motor speeds | If the measured motor speed versus the measured motor speed while controlling the target > 5.0 for more than 12 seconds. | "}, + { 39 , ALARM_ID_HD_DIAL_OUT_PUMP_MC_CURRENT_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPo Current | Dialysis outlet pump failed motor controller current check. Too high when pump should be off or out of range when pump should be running | If the DPo pump current > 150.0 mA while stopped or Dpo current > 2000.0 mA for more than 2 seconds while running. | "}, + { 40 , ALARM_ID_HD_DIAL_OUT_PUMP_OFF_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPo Speed | Dialysis outlet pump failed motor off check. Measured speed while commanded off | If the Dpo pump current > 100.0 RPM while commanded off for more than 5000 msec. | "}, + { 41 , ALARM_ID_HD_DIAL_OUT_PUMP_MC_DIRECTION_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPo Direction | Dialysis outlet pump failed motor direction check. Measured vs. commanded | If the DPo pump set direction does not agree with hall sensors or set direction does not agree with the sign of the motor speed for more than 25 msec. | "}, + { 42 , ALARM_ID_HD_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK , "HD | Dialysate Pump Error | A problem has been detected with the dialysate pump.\n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue.\n\nHD Fault: DPo Rotor | Dialysis outlet pump failed rotor speed check. Mismatch with rotor and motor speeds | If DPo pump measured rotor speed does not agreed with the measured/commanded motor speed | "}, + { 43 , ALARM_ID_DG_MAIN_PRIMARY_HEATER_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Iso ADC Comm | Main primary heater FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 44 , ALARM_ID_HD_UI_COMM_TIMEOUT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: UI Comm | User interface communication timeout | If the sub-system communication timeout has occurred. UI is 5 seconds. DG is 2 seconds. | "}, + { 45 , ALARM_ID_HD_COMM_TOO_MANY_BAD_CRCS , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: CAN CRC Com | Too many bad CRCs detected on received system messages | If too many bad messages CRCs are received within a set period of time | "}, + { 46 , ALARM_ID_HD_CAN_MESSAGE_NOT_ACKED_BY_UI , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: CAN ACK UI Com | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, + { 47 , ALARM_ID_AVAILABLE_16 , " | | \n\n | | | "}, + { 48 , ALARM_ID_HD_UF_VOLUME_ACCURACY_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: UF Rate Tare Err | Ultrafiltration volume accuracy error during treatment | If the UF volume (refUFvolume - measureVolume) > 100.0 mL. | "}, + { 49 , ALARM_ID_HD_FPGA_COMM_TIMEOUT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: FPGA Com | HD FPGA communication down for too long | If there are more than 3 comm errors in a 1 min period. | "}, + { 50 , ALARM_ID_DG_VALVE_CONTROL_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Valve Control | DG FPGA not accepting commanded valve states | If the read back FPGA valve states does not match the commanded valve states for a certain amount of time. | "}, + { 51 , ALARM_ID_HD_BLOOD_PUMP_MOTOR_SPEED_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Speed | Blood pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded rotor speed exceeded limits. | "}, + { 52 , ALARM_ID_HD_DIAL_IN_PUMP_MOTOR_SPEED_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPi Speed | Dialysate inlet pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded motor speed exceeded limits for more than 5 secs. | "}, + { 53 , ALARM_ID_HD_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: DPo Speed | Dialysate outlet pump failed motor speed check. Measured vs. commanded | If measured motor speed versus commanded motor speed exceeded limits for more than 5 secs. | "}, + { 54 , ALARM_ID_HD_CRITICAL_DATA_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Critical Data Err | HD critical data integrity check failed | If the critical data failed range check. | "}, + { 55 , ALARM_ID_DG_CRITICAL_DATA_ERROR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Critical Data Err | DG critical data integrity check failed | If the critical data failed range check. | "}, + { 56 , ALARM_ID_HD_ACCELEROMETER_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Acc Com | HD accelerometer error (no readings or FPGA reports error) | If no fresh sample of accelerometer data has been detected for more than 100 msec. | "}, + { 57 , ALARM_ID_DG_ACCELEROMETER_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Acc Com | DG accelerometer error (no readings or FPGA reports error) | If no fresh sample of accelerometer data has been detected for more than 100 msec. | "}, + { 58 , ALARM_ID_HD_VALVE_HOMING_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Valve Home | HD valve homing failed | If the number of failed homing > = 3 counts. | "}, + { 59 , ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Valve Transition Err | HD valve transition time out | if the valve's transition time has timed out (3000msec) | "}, + { 60 , ALARM_ID_HD_VALVE_NOT_FUNCTIONAL , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Valve Control | HD valve not functional | If the valve bit masks are not as expected in different valve control mode. | "}, + { 61 , ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Valve Current | HD valve current out of range | If the valve current is over the threshold of 1.0 A for 1000 msec. | "}, + { 62 , ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Valve Position | HD valve position out of target | If the current position has deviated from the expected position for more than 1 second. | "}, + { 63 , ALARM_ID_HD_BLOOD_LEAK_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BLD Com | FPGA reports error | If the FPGA error counter increments for a certain period of time. | "}, + { 64 , ALARM_ID_DG_BARO_PRESSURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Baro Range | Barometric pressure is out of range | If the barometric pressure is > 10.1 psi or < 15.4 psi for a certain period of time. | "}, + { 65 , ALARM_ID_HD_DG_COMMAND_INVALID_PARAMETER_FAULT , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (Reject) | HD requests DG command with invalid parameter fault | If the latest DG command response indicated invalid parameter | "}, + { 66 , ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: BLD Config Set Point | HD blood leak sensor set point set failure | If the set point of the blood leak sensor does not match the set point in the calibration record. | "}, + { 67 , ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE , "HD | Self Test: Cartridge | A cartridge has been detected during self-test.\n- Open door\n- Remove cartridge\n- Close door\n- Resume\n\nProcess: Pre-Tx Remove Cartridge | HD blood pump occlusion self-test failure alarm | If the blood pump pressure > 5000 | "}, + { 68 , ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE , "HD | Dialysate Generation Error | A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed when \ndialysate is ready for use. \n\nDial. Gen: Dialysate not ready | HD active reservoir recirculation out of range | If the recirculation level has exceeded the max allowed | "}, + { 69 , ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD POST: BLD Cal | HD blood leak sensor invalid calibration record | If the BLD data that was received from NVDataMgmt is NOT legitimate. | "}, + { 70 , ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE , "HD | Self Test: Cartridge | A cartridge has been detected during self-test.\n- Open door\n- Remove cartridge\n- Close door\n- Resume\n\nProcess: Pre-Tx Remove Cartridge | HD arterial pressure self-test failure alarm | If arterial pressure < -300 or > 100 mmHg | "}, + { 71 , ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE , "HD | Self Test: Cartridge | A cartridge was detected during self-test.\n- Open door\n- Remove cartridge\n- Close door\n- Resume\n\nProcess: Pre-Tx Remove Cartridge | HD venous pressure self-test failure alarm | If the venous pressure < -100 or > 600 mmHg | "}, + { 72 , ALARM_ID_HD_NEW_LOAD_CELL_DATA_MESSAGE_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (LC) | HD No load cell data message receive at least once every 2 seconds | No new load cell data for 2 seconds. | "}, + { 73 , ALARM_ID_HD_NEW_DIALYSATE_TEMP_DATA_MESSAGE_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (TDI/TRO) | HD No dialysate temperature data message received at least once every 2 seconds | No new dialysate temperature data for 2 seconds. | "}, + { 74 , ALARM_ID_DG_INLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: UVi On No Flow | DG inlet UV reactor is on while there is no flow | If the inlet UV reactor is on while VPi is closed for a certain period of time. | "}, + { 75 , ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe DAC | HD syringe pump self-test failure alarm | If the calibration data that was received from NVDataMgmt and the DAC voltage with syringe retracted are not within tol. | "}, + { 76 , ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Voltage Monitor | HD monitored voltage is out of range | If the HD monitored voltages are out of range for a certain period of time. | "}, + { 77 , ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Voltage Monitor | DG monitored voltage is out of range | If the DG monitored voltages are out of range for a certain period of time. | "}, + { 78 , ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Enc Dir | HD syringe pump direction (from encoder) error | If the measured encoder direction of the syringe pump does not agree with the expected direction | "}, + { 79 , ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Drv Dir | HD syringe pump direction (from controller) error | If the measured direction of the syringe pump motor controller does not agree with the expected direction | "}, + { 80 , ALARM_ID_HD_SYRINGE_PUMP_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Driver | HD syringe pump fault reported by FPGA | If the FPGA reported the syringe pump fault | "}, + { 81 , ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump OT | HD syringe pump over travel error | If the syringe pump position is deemed to have overtraveled | "}, + { 82 , ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump DAC Err | HD syringe pump DAC write failure | If the syringe pump DAC write error is reported by the FPGA | "}, + { 83 , ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump On Err | HD syringe pump is running while the BP is off | If the syringe pump is on while the blood pump is off | "}, + { 84 , ALARM_ID_DG_SET_RTC_YEAR_INVALID , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: HD RTC Time | DG RTC set year is invalid | If DG RTC set year is < 2021. | "}, + { 85 , ALARM_ID_HD_PUMP_TRACK_LATCH_OPENED , "HD | Cartridge Lever is Open | A problem has been detected with the cartridge.\n- Open the device door and push lever all the way down.\n- Close the device door.\n- Press RESUME button to continue.\n\nBlood Stop: Cartridge Lever Open | HD pump track lever is not fully latched | If the pump track lever is detected as unlatched when it should be. | "}, + { 86 , ALARM_ID_HD_SET_RTC_YEAR_INVALID , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: HD RTC Time | HD RTC set year is invalid | If HD RTC set year is < 2021. | "}, + { 87 , ALARM_ID_DG_HEATING_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Heat Cal | DG heating parameters invalid calibration record | If the heating paramters' non-volatile record's CRC does not match the calculated CRC. | "}, + { 88 , ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CP1 CP2 Speed Range | DG concentrate pump hall sensor out of range. | Hall sensor pulse to pulse timing is < 1ms (speed too fast). | "}, + { 89 , ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: UVo On No Flow | DG outlet UV reactor is on while there is no flow | If the outlet UV reactor is on while the RO flow is less than 200 mL/min. | "}, + { 90 , ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: LC A1/B1 Comm | DG load cells A1/B1 FPGA fault | If the FPGA does not report fresh data for a certain period of time. | "}, + { 91 , ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nLoss of DG Comm (FMD) | HD No dialysate flow data received in the last 3 seconds | If not receiving new dialysate flow readings in expected interval (3 seconds) | "}, + { 92 , ALARM_ID_AVAILABLE_1 , " | | \n\n | | | "}, + { 93 , ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Permeate Cond High | DG outlet primary conductivity sensor out of range | If the outlet primary conductivity sensor, CPo is greater than 30 uS/cm for a certain period of time. | "}, + { 94 , ALARM_ID_DG_PRESSURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Pressure Sensor Range | DG pressure sensor out of range | If either of the pressure sensors is < 0 psia or > 200 psia for DG pressure sensors. | "}, + { 95 , ALARM_ID_DG_WATCHDOG_EXPIRED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: WD Error | DG watchdog expired | If the watchdog signal is low while not in POST. | "}, + { 96 , ALARM_ID_DG_INLET_WATER_TEMPERATURE_IN_HIGH_RANGE , "DG | Incoming Water Temperature High | Incoming water temperature is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the temperature is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Temp High | DG inlet water temperature out of range | If the inlet water temperature is > 37 C. | "}, + { 97 , ALARM_ID_DG_FILL_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Out of Range | Treatment is currently paused.\n-Confirm that acid and bicarbonate concentrates are securely connected. \n- If empty, replace. \n-Treatment will need to be resumed when conductivity is within target range.\n\nDial. Gen: Dialysate Cond. | DG fill conductivity out of range | If the average acid or bicard conductivity is > 5% of the normal acid and bicarb conductivity values. | "}, + { 98 , ALARM_ID_HD_BATTERY_COMM_FAULT , "HD | Service Required: Hemodialysis Device | A non-critical problem was detected with the hemodialysis device.\n-Call service to report the issue and schedule a repair.\n\nHD Alarm (Low): Battery Com | HD battery or battery charger communication fault | If battery I2C communication fault persistence count > 5. | "}, + { 99 , ALARM_ID_HD_SYRINGE_PUMP_STALL , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Stall | HD syringe pump stall alarm | If syringe pump measured rate < stall speed threshold (0.05) and the ramp up has been restarted 3 times after stall has been detected. | "}, + { 100 , ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Timeout No Cart ST | HD no cartridge self-test timeout | If during the no cartridge self-tests state, the elapsed self-test time > maximum no cartridge self test time (30secs) | "}, + { 101 , ALARM_ID_UI_POST_HD_COMM , "UI | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI-Proc Comm | UI POST FW Communication failure | If the HD is not communicating with the UI during POST. | "}, + { 102 , ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE , "DG | Disinfection Interrupted | Disinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Tpo THD Temp Delta | DG heat disinfection temperature gradient out of range | If temperature gradient between Tpo and Thd exceeds maximum 15°C. | "}, + { 103 , ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD POST: Cal NVRAM CRC | HD non-volatile calibration group invalid record CRC | If the computed CRC of the calibration group record is not equal to the record CRC. | "}, + { 104 , ALARM_ID_HD_AIR_TRAP_ILLEGAL_LEVELS , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Air Trap Sensor | Air trap level sensors reporting illegal combination of air/fluid | If the air trap level readings are not valid for more than 2 seconds. | "}, + { 105 , ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: Cal NVRAM CRC | DG non-volatile system group invalid record CRC | If the DG NVDATAMGMT CAL group calculated CRC does not mached the expected CRC. | "}, + { 106 , ALARM_ID_DG_FLOW_SENSORS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Flow Sensor Cal | DG flow sensors calibration error | If the calculated CRC of the flow sensors calibration record does not match the calibration records' CRC. | "}, + { 107 , ALARM_ID_HD_DG_RESTARTED_FAULT , "HD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DG Restarted | HD reports DG restarted fault | If DG reports being in any mode other than idle, drain, fill or fault during pre-tx, tx, or post-tx modes - means DG restarted unexpectedly and is no longer in sync w/ HD. | "}, + { 108 , ALARM_ID_HD_SYRINGE_PUMP_FPGA_ADC_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump ADC Com | HD syringe pump ADC error | If the ADC read is not fresh after POST init and the ADC read counter has not changed. | "}, + { 109 , ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Vol | HD syringe pump volume check error | If the volume delivered is off by more than 5% or 0.1mL. | "}, + { 110 , ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Speed | HD syringe pump speed check error | If the syringe measured rate is off by more than 5% or 0.1mL. | "}, + { 111 , ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Syringe Pump Speed | HD syringe pump not stopped in off state error | If the syringe pump position is not equal to its last position. | "}, + { 112 , ALARM_ID_DG_LOAD_CELL_A2_B2_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: LC A2/B2 Comm | DG load cells A2/B2 FPGA fault | If the FPGA does not report fresh data for a certain period of time. | "}, + { 113 , ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DRP Current | DG drain pump current out of range | If the DG drain pump current > 2.2 A when it is in open loop or if the current > 0.1 A when it is off. | "}, + { 114 , ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE , "HD | Self Test: Venous Air Detector | A problem has been detected with the venous air detector.\n- Check cartridge installation.\n- If problem persists, terminate treatment preparation and \n begin again using a new cartridge.\n\nProcess: Pre-Tx Wet Self-Test | HD venous air bubble detector self-test failure | If the venous air bubble self test did not detect bubble for more than 500 msec. | "}, + { 115 , ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Temp Sensor Range | DG temperature sensor out of range | If the measured temperature < 0 C or > 80 C for the non-fluid inline sensors and > 120 C for the fluid sensors. | "}, + { 116 , ALARM_ID_HD_UI_SDCARD_FAILURE , "UI HD | Service Required: Dialysate Device | A non-critical problem was detected with the hemodialysis device.\n-Call service to report the issue and schedule a repair.\n\nHD Alarm (Low): SD-Card Error | SD card is non-operational | SD card is non-operational | "}, + { 117 , ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED , "DG | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of HD Comm (HD ACK) | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, + { 118 , ALARM_ID_DG_RTC_CONFIG_ERROR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RTC Config | DG RTC configuration error | If the RTC configuration registers report an error. | "}, + { 119 , ALARM_ID_DG_RTC_BATTERY_LOW , "DG | Service Required: Dialysate Device | A non-critical problem was detected with the dialysate device.\n-Call service to report the issue and schedule a repair.\n\nDG Alarm (Low): RTC Bat Low | DG RTC battery low | If the RTC battery bit report a low alarm. | "}, + { 120 , ALARM_ID_HD_PRE_TREATMENT_WET_PRIME_TEST_FAILURE , "HD | Self Test: Venous Air Detector | A problem has been detected with the venous air detector\n- Check cartridge installation.\n- If problem persists, terminate treatment preparation and \n start over using a new cartridge.\n\nProcess: Pre-Tx Wet Self-Test | HD pre-treatment wet prime test failure | If the HD pre-treatment wet self test failed. | "}, + { 121 , ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Prim Heater Lg Control | DG main primary heater voltage out of range | If the main primary heater's voltage is out of range. | "}, + { 122 , ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Prim Heater Sm Control | DG small primary heater voltage out of range | If the small primary heater's voltage is out of range. | "}, + { 123 , ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Trimmer Heater Control | DG trimmer heater voltage out of range | If the trimmer voltage is out of range. | "}, + { 124 , ALARM_ID_HD_END_OF_TREATMENT_HIGH , "HD | Blood Pump Stop Time Exceeded | The blood pump has been off for too long.\n- Treatment must be terminated without rinseback.\n\nBlood Stop: Blood Clot Risk | HD end of treatment alarm (high priority - user still not acting to end treatment) | In treatment end paused state for > 5 minutes. | "}, + { 125 , ALARM_ID_HD_TREATMENT_STOPPED_NO_RINSEBACK , "HD | Blood Pump Stop Time Exceeded | The blood pump has been off for too long.\n- Treatment must be terminated without rinseback.\n\nBlood Stop: Blood Clot Risk | Blood sitting too long after treatment stopped by user alarm (> 5 min) | If in treatment stop sub mode when blood is in the tubing, the blood sitting counter exceeded 5 minutes. | "}, + { 126 , ALARM_ID_HD_BLOOD_LEAK_DETECTED , "HD | Blood Leak | A blood leak has been detected. \n-Treatment must be terminated without rinseback.\n\nBlood Stop: Dialyzer Blood Leak | HD blood leak detected alarm | If the blood leak is detected based on the blood leak status reported by the sensor. | "}, + { 127 , ALARM_ID_HD_VENOUS_PRESSURE_LOW , "HD | Low Venous Pressure | Venous pressure is low.\n- Ensure venous access connections are properly secured. \n-If there has been an access disconnection or needle dislodgement, \nfollow facility policy to address and terminate treatment without rinseback. \n-If access connections are properly secured, \npress RESUME to continue treatment.\n\nBlood Stop: Venous Pres. Low | Venous pressure too low during treatment | If the venous pressure < TREATMENT_PARAM_VEN_PRESSURE_LOW_LIMIT. Or expanded pressure limits based on mode of operation. | "}, + { 128 , ALARM_ID_HD_VENOUS_BUBBLE_DETECTED , "HD | Venous Air Detected | Air detected in the venous air trap.\n- Confirm arterial access placement and confirm connections are secure.\n- Treatment must be terminated without rinseback.\n\nBlood Stop: Venous Air Bubble | HD venous air bubble detected alarm | If bubbles are detected during the treatment. | "}, + { 129 , ALARM_ID_AVAILABLE_17 , " | | \n\n | | | "}, + { 130 , ALARM_ID_HD_VENOUS_PRESSURE_HIGH , "HD | High Venous Pressure | Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n-Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback.\n\nBlood Stop: Venous Pres. High | Venous pressure too high during treatment | If the venous pressure > TREATMENT_PARAM_VEN_PRESSURE_HIGH_LIMIT. Or expanded pressure limits based on mode of operation. | "}, + { 131 , ALARM_ID_HD_ARTERIAL_PRESSURE_LOW , "HD | Low Arterial Pressure | Arterial pressure is low.\n- Inspect arterial bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback.\n\nBlood Stop: Arterial Pres. Low | Arterial pressure too low during treatment | If the arterial pressure < TREATMENT_PARAM_ART_PRESSURE_LOW_LIMIT. Or expanded pressure limits based on mode of operation. | "}, + { 132 , ALARM_ID_HD_ARTERIAL_PRESSURE_HIGH , "HD | High Arterial Pressure | Arterial pressure is high.\n- Ensure arterial access connections are properly secured.\n- Check needle placement and/or access position.\n-Resolve access issues if applicable.\n- If clots are present, end treatment without rinseback.\n\nBlood Stop: Arterial Pres. High | Arterial pressure too high during treatment | If the arterial pressure > TREATMENT_PARAM_ART_PRESSURE_HIGH_LIMIT. Or expanded pressure limits based on mode of operation. | "}, + { 133 , ALARM_ID_DG_FLUID_LEAK_DETECTED , "DG | Dialysate Device Fluid Leak | Fluid leak detected in the dialysate device.\n-Treatment must be terminated.\n- Turn off water source. \n-Disconnect water and electrical connections from the device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Fluid Leak in DG | DG fluid leak detected alarm | If the fluid leak is detected as reported by the fluid leak detector. | "}, + { 134 , ALARM_ID_HD_FLUID_LEAK_DETECTED , "HD | Fluid Leak | Fluid leak detected in hemodialysis device.\n- If in treatment, blood pump is off.\n-Identify and correct the cause of the fluid leak.\n- Clean up fluid and dry leak sensor.\n- Once fluid has been cleaned up, resume treatment.\n\nBlood Stop: Fluid Leak in HD | HD fluid leak detected alarm | If the fluid leak is detected as reported by the fluid leak detector. | "}, + { 135 , ALARM_ID_HD_SHOCK , "HD | Blood Pump Stopped: Excessive Movement | Excessive movement of the hemodialysis device has been detected. \n-Treatment is currently paused. \n-When system movement has stablized, \ntreatment will need to be resumed.\n-To resume treatment, press OK.\n\nBlood Stop: HD Shock Detected | HD experienced large acceleration | If the system experienced excessive shock > 2.5 g. | "}, + { 136 , ALARM_ID_DG_SHOCK , "DG | Dialysate Device: Excessive Movement | Excessive movement of the dialysate device has been detected.\n-Treatment is currently paused. \n-Treatment can be resumed when system movement has stablized.\n\nDial. Gen: Shock-Vibration | DG experienced large acceleration | If the system experienced excessive shock > 2.5 g. | "}, + { 137 , ALARM_ID_HD_EXCESSIVE_TILT , "HD | Blood Pump Stopped: Excessive Tilt | Excessive tilt of the hemodialysis device has been detected. \n-Treatment is currently paused. \n-When the device is stationary and level, \ntreatment will need to be resumed.\n-To resume treatment, press OK.\n\nBlood Stop: HD Tilted | HD tilt exceeds maximum | If the system experienced excessive tilt x and y axis angle > 7 deg for more than 1 sec. | "}, + { 138 , ALARM_ID_DG_EXCESSIVE_TILT , "DG | Dialysate Device: Excessive Tilt | Excessive tilt of the dialysate device has been detected.\n- Treatment is paused.\n-Confirm the device is stationary and level before continuing.\n\nDial. Gen: Tilt | DG tilt exceeds maximum | If the system experienced excessive tilt x and y axis angle > 7 deg for more than 1 sec. | "}, + { 139 , ALARM_ID_HD_AC_POWER_LOST , "HD | Power Loss | AC Power has been lost.\n-Check all electrical connections.\n- Press OK to return to welcome screen. \n\nLoss of AC Power | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in standby, service, or treatment parameters mode. | "}, + { 140 , ALARM_ID_HD_DG_COMM_TIMEOUT , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (Timeout) | Dialysate generator communication timeout | If DG communication timeout is detected for more than 2 seconds. | "}, + { 141 , ALARM_ID_HD_AIR_TRAP_FILL_DURING_TREATMENT , "HD | Blood Pump Stopped: Venous Air Detector | A problem was detected with the venous air detector.\n- Confirm arterial access placement and ensure connections are secure.\n- Treatment must be terminated without rinseback.\n\nBlood Stop: Air Trap Fill | Air trap fill timeout during treatment | If the air trap fill timeout during treatment. | "}, + { 142 , ALARM_ID_HD_OCCLUSION_BLOOD_PUMP , "HD | Blood Pump Stopped: Occulusion | Occlusion detected after the blood pump.\n-Inspect bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback.\n\nBlood Stop: Blood Pump Occlusion | Blood pump occlusion detected | If blood occlusion is detected > OCCLUSION_THRESHOLD_OFFSET + bloodPumpOcclusionAfterCartridgeInstall | "}, + { 143 , ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: TRo TDi Delta | DG dialysate temperature sensors drift timeout. | If TDi and TRo have drifted for more 1 C for a certain period of time. | "}, + { 144 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_HIGH , "DG | Disinfection: Water Conductivity High | Incoming water conductivity is too high.\n-Disinfection has been terminated.\n- Check incoming water before initiating disinfection again. \n\nCleaning: Inlet Water Cond High | DG cleaning mode inlet water conductivity out of high range | Inlet water conductivity > 2000 uS/cm. Inlet water conductivity > 100 uS/cm (PURE WATER MODE). In cleaning mode | "}, + { 145 , ALARM_ID_DG_ACID_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Error During Prime | Conductivity out of range during prime.\n-Confirm that acid and bicarbonate concentrates are securely connected. \n- If empty, replace. \n-Treatment will need to be resumed when conductivity is within target range.\n\nDial. Gen: Acid Conc. Cond. | DG Concentrate conductivity after adding acid out of range alarm | If the conductivity value for the acid concentrate is out of range for more than 45 secs. | "}, + { 146 , ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: DG RTC Timer | DG RTC vs. Timer accuracy error | If RTC and timer are not aligned on 1 second elapsed time. | "}, + { 147 , ALARM_ID_DG_CREATING_DIALYSATE_PLEASE_WAIT , "DG | Dialysate Generation Error | A problem has been detected with dialysate generation. \n- Treatment is paused and will be need to be resumed when \nthe dialysate is ready for use. \n\nDial. Gen: Dialysate not ready | DG dialysate generation conductivity fault alarm | If dialysate conductivity is not with 5% of the TCD | "}, + { 148 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_HIGH , "DG | Disinfection: Water Temperature High | Incoming water temperature is too high.\n-Disinfection has been terminated.\n- Check incoming water before initiating disinfection again. \n\nCleaning: Inlet Water Temp High | Cleaning Mode Inlet water temperature too high | Inlet temperature > 37 C. | "}, + { 149 , ALARM_ID_HD_WATCHDOG_EXPIRED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: WD Error | HD watchdog expired | If the watchdog signal is low while not in POST. | "}, + { 150 , ALARM_ID_DG_INLET_WATER_CONDUCTIVITY_IN_HIGH_RANGE , "DG | Incoming Water Conductivity High | Conductivity of incoming water is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the conductivity is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Cond High | Inlet water conductivity too high | Inlet water conductivity > 2000 uS/cm. Inlet water conductivity > 100 uS/cm (PURE WATER MODE). | "}, + { 151 , ALARM_ID_DG_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE , "DG | Incoming Water Conductivity Low | Conductivity of incoming water is low.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the conductivity is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Cond Low | Inlet water conductivity too low | Inlet water conductivity < 200 uS/cm. Inlet water conductivity low disabled (PURE WATER MODE). | "}, + { 152 , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_LOW_RANGE , "DG | Incoming Water Pressure Low | Water pressure of incoming water is low.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the pressure is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Pres Low | Inlet water pressure too low | Inlet water pressure < 25 PSI. | "}, + { 153 , ALARM_ID_HD_PRIME_COMPLETED_HIGH , "HD | Pre-Treatment Process Terminated | The pre-treatment process has been terminated because \ntreatment did not begin within two hours of priming. \n-Press OK for continue with next steps to remove cartridge from the device.\n\nProcess: Pre-Tx Terminated | HD prime completed high priority alarm | In Pre-Treatment Recirculation for 120 minutes (escalation of alarm 213) | "}, + { 154 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_LOW , "DG | Disinfection: Water Conductivity Low | Incoming water conductivity is too low.\n-Disinfection has been terminated.\n- Check incoming water before initiating disinfection again. \n\nCleaning: Inlet Water Cond Low | Cleaning mode inlet water conductivity too low | Inlet water conductivity < 200 uS/cm. Inlet water conductivity low disabled (PURE WATER MODE). In cleaning mode | "}, + { 155 , ALARM_ID_HD_NEW_RESERVOIRS_DATA_MESSAGE_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (Reservoir) | HD No reservoir data message receive at least once every 2 seconds | No new reservoir data for 2 seconds. | "}, + { 156 , ALARM_ID_HD_DG_NEW_OPERATION_MODE_MESSAGE_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected within the Diality Hemodialysis System.\n-Treatment must be terminated.\n- Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nLoss of DG Comm (Op Mode) | HD No DG op mode message receive at least once every 2 seconds | No DG op mode for 2 seconds. | "}, + { 157 , ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT , "DG | Chemical Disinfectant Not Detected | Unable to sense proper chemical disinfectant.\n- Disinfection process has terminated.\n- Confirm chemical disinfectant is connected to the concentrate inlet. \n- Confirm chemical disinfectant container is not empty.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Chem Disinf PAA Prime | Chemical disinfect priming the acid line timeout | If the disinfectant acid line is not primed within a certain period of time. | "}, + { 158 , ALARM_ID_DG_INLET_WATER_TEMPERATURE_IN_LOW_RANGE , "DG | Incoming Water Temperature Low | Incoming water temperature is low.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the temperature is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Temp Low | Inlet water temperature low | Inlet temperature < 24 °C for 5 seconds. | "}, + { 159 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID , "DG | Remove Chemical Disinfectant | The chemical disinfectant is no longer needed. \n-Disconnect chemical disinfectant from the device. \n-Place the concentrate connection cap on the device.\n-Keep dialysate cap on the device.\n\nCleaning: Chem Disinf Connect Cap | Close concentrate line be able to flush it | Start of chemical disinfect flush. | "}, + { 160 , ALARM_ID_HD_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Rotor Max Speed | Blood pump rotor speed too high | If blood pump motor speed exceeded 100.0 RPM. | "}, + { 161 , ALARM_ID_DG_COMM_TOO_MANY_BAD_CRCS , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: HD-DG Comm | Too many bad CRCs detected on received system messages | If >= 5 bad CRCs detected on received CAN messages within 10 minutes. | "}, + { 162 , ALARM_ID_DG_FPGA_CLOCK_SPEED_CHECK_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Proc-FPGA Clock | FPGA clock speed failure | If the FPGA clock speed is relatively close to the processor clock for a certain period of time. | "}, + { 163 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM , "HD | Ultrafiltration Error | A problem was detected with the dialysate device. \n-Confirm the device is level with minimal movement. \n-Resume treatment. \n-If problem persists, call service to report the issue and schedule a repair. \n\nDial. Gen: UF Rate Check | HD sees primary load cell for reservoir 1 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, + { 164 , ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM , "HD | Ultrafiltration Error | A problem was detected with the dialysate device. \n-Confirm the device is level with minimal movement. \n-Resume treatment. \n-If problem persists, call service to report the issue and schedule a repair. \n\nDial. Gen: UF Rate Check | HD sees primary load cell for reservoir 2 change too much too fast | If the delta volume of the active reservoir exceeded 50.0 g (MAX_ACTIVE_LOAD_CELL_CHANGE_G). | "}, + { 165 , ALARM_ID_HD_TREATMENT_RINSEBACK_TIMEOUT_ALARM , "HD | Blood Pump Stop Time Exceeded | The blood pump has been off for too long.\n- Treatment must be terminated without rinseback.\n\nBlood Stop: Blood Clot Risk | HD in treatment rinseback operation timeout | If the maximum time inrinseback operation has been exceeded. | "}, + { 166 , ALARM_ID_AVAILABLE_3 , " | | \n\n | | | "}, + { 167 , ALARM_ID_HD_CARTRIDGE_DOOR_OPENED , "HD | Blood Pump Stopped: Door Open | The device door is open.\n Close the device door. \n-Press RESUME to continue.\n\nBlood Stop: Door Open | HD cartridge door opened alarm | If the cartridge door is opened as reported by the FPGA. | "}, + { 168 , ALARM_ID__AVAILABLE_70 , " | | \n\n | | | "}, + { 169 , ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Dialysate Flow Sens Rg | Dialysate flow rate out of range | If the dialysate flow rate > 2.00 L/min. | "}, + { 170 , ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY , "HD | Heparin Syringe Empty | Heparin syringe is empty.\n- Treatment will continue without heparin.\n- Refer to facility policy if additional heparin is needed to complete treatment.\n\nHeparin Syringe Empty | HD syringe empty alarm | If the syringe pump position is near empty position. | "}, + { 171 , ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION , "HD | Heparin Pump Occlusion | A problem has been detected with the heparin pump.\n- Ensure heparin line is not kinked or clamped.\n\nProcess: Pre-Tx Hep. Pump Occ. | HD syringe pump occlusion alarm | If the pressure sensor voltage reading > SYRINGE_FORCE_OCCLUSION_THRESHOLD_V. | "}, + { 172 , ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM , "HD | Not Enough Heparin | There is not enough heparin available for treatment.\n- Ensure the syringe pump is touching the syringe plunger.\n- If the syringe pump is touching the syringe plunger, end treatment.\n- If syringe pump is not touching the syringe plunger, \n- ensure the correct amount of heparin has been drawn and reload the syringe. \n\nProcess: Pre-Tx Not Enough Hep. | HD syringe pump not enough Heparin alarm | If the estimated syringe volume needed for treatment is not sufficient | "}, + { 173 , ALARM_ID_HD_RTC_CONFIG_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: RTC Config | HD RTC configuration error | If the RTC configuration registers report an error. | "}, + { 174 , ALARM_ID_HD_RTC_OR_TIMER_ACCURACY_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD POST: HD RTC Timer | HD RTC vs. Timer accuracy error | If RTC and timer are not aligned on 1 second elapsed time. | "}, + { 175 , ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Pump Commutation Err | HD pump commutation error | If the set pump direction does not agree with the hall sensor direction. | "}, + { 176 , ALARM_ID_AVAILABLE_4 , " | | \n\n | | | "}, + { 177 , ALARM_ID_DG_SOFTWARE_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Software Invalid State | DG software fault. Software found itself in an unexpected state | If the specific software faults listed in alarm management SW faults has been detected | "}, + { 178 , ALARM_ID_HD_COMM_TIMEOUT , "UI | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: UI-Proc Comm | HD communication timeout | If the HD stops communicating with the UI. | "}, + { 179 , ALARM_ID_DG_FPGA_COMM_TIMEOUT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: FPGA Com | DG FPGA communication down for too long | If retries for commands exceeds limit or FPGA reports comm error. | "}, + { 180 , ALARM_ID_DG_RO_FLOW_RATE_OUT_OF_MAX_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Flow Sensor Range | RO flow rate out of range | If the RO flow rate > 2.00 L/min. | "}, + { 181 , ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Tare Out of Range | DG load cells weight out of range for tare | If the load cell weight is out of range for tare. | "}, + { 182 , ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nDG POST: LC Cal | DG load cells invalid calibration | If the CRC of load cells calibration data does not match the calculated CRC. | "}, + { 183 , ALARM_ID_DG_INVALID_LOAD_CELL_VALUE , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Invalid Resv Transfer | DG invalid load cell value | If the half full reservoir is filled prior to filling the reservoir that is supposed to overflow to the half full reservoir. | "}, + { 184 , ALARM_ID_DG_INLET_UV_REACTOR_NOT_HEALTHY , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: UVi Error | Inlet reactor not healthy | If the inlet reactor are not healthy. | "}, + { 185 , ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A non-critical problem was detected with the dialysate device.\n-Call service to report the issue and schedule a repair.\n\nDG Alarm (Low): Fan Speed | DG fan RPM out of range | If the fan RPM is out of Min/Max range. | "}, + { 186 , ALARM_ID_DG_CONCENTRATE_PUMP_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CP1/CP2 Fault | DG concentrate pump fault | If the concentrate pumps fault is reported by the FPGA. | "}, + { 187 , ALARM_ID_DG_CP1_SPEED_CONTROL_ERROR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CP1 Speed Fault | DG concentrate pump CP1 speed control error | If the concentrate pump CP1 speed > 0.02 tolerance for a certain period of time. | "}, + { 188 , ALARM_ID_DG_CP2_SPEED_CONTROL_ERROR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CP2 Speed Fault | DG concentrate pump CP2 speed control error | If the concentrate pump CP1 speed > 0.02 tolerance for a certain period of time. | "}, + { 189 , ALARM_ID_DG_DRAIN_PUMP_RPM_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DRP Speed Fault | DG drain pump RPM out of range | If the drain pump RPM > 100.0 of the target RPM. | "}, + { 190 , ALARM_ID_DG_DRAIN_PUMP_OFF_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DRP Speed Not Off | DG drain pump off fault | If the pump is in off state and the RPM is greater than the minimum RPM of 300.0 RPM. | "}, + { 191 , ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Flow High | DG flow rate out of upper range | If the RO flow rate > 10% from the target flow rate. | "}, + { 192 , ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Flow Low | DG flow rate out of lower range | If the RO flow rate < 10% from the target flow rate. | "}, + { 193 , ALARM_ID_AVAILABLE_5 , " | | \n\n | | | "}, + { 194 , ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Driver Feedback | DG RO pump duty cycle out of range | If the DG RO pump duty cycle is out of range by 5% of the target duty cycle for a certain period of time. | "}, + { 195 , ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Pump High Pressure | DG RO pump pressure out of range | If the DG RO pump pressure > 135 psi for a certain period of time. | "}, + { 196 , ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CPi/CPo Comm | DG CPi/CPo conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "}, + { 197 , ALARM_ID_DG_CD1_CD2_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CD1/CD2 Comm | DG CD1/CD2 conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "}, + { 198 , ALARM_ID_DG_RO_FLOW_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: HP On With No Flow | DG primary heater while RO flow is low | If the RO flow is < 0.2 L/min for a certain period of time. | "}, + { 199 , ALARM_ID_DG_DIALYSATE_FLOW_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: HR On With No Flow | DG trimmer heater while dialysate flow is low | If the FMD flow is ≤ 0 mL/min (raw) for a certain period of time. | "}, + { 200 , ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Thermistor Range | DG thermistor or temperature sensor out of range | If thermistor > 80.0 C or < 0.0 C. | "}, + { 201 , ALARM_ID_HD_PRE_TREATMENT_WET_FLOW_TEST_FAILURE , "HD | Self Test: Dialysate Flow Rate | A problem has been detected when measuring dialysate flow.\n- Confirm cartridge is properly installed and primed.\n- If problem persists, terminate treatment preparation and \n start over using a new cartridge.\n\nProcess: Pre-Tx Wet Self-Test | HD pre-treatment wet flow test failure | If the pre-treatment wet flow test has failed. | "}, + { 202 , ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE , "HD | Self Test: Pressure | A problem has been detected during self-test. \n-Confirm the cartridge is properly installed. \n-Ensure arterial and venous pressure sensor lines are not kinked. \n-Press OK to resume. \n-If problem persists, install a new cartridge.\n\nProcess: Pre-Tx Dry Self-Test | HD pre-treatment dry pressure normal test failure | If the pre-treatment dry pressure normal test failed. | "}, + { 203 , ALARM_ID_AVAILABLE_6 , " | | \n\n | | | "}, + { 204 , ALARM_ID_DG_RO_REJECTION_RATIO_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: RO Rejection | RO rejection ratio out of range | If RO rejection ratio > 0.1 | "}, + { 205 , ALARM_ID_DG_CONDUCTIVITY_SENSOR_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Cond Sensors Error | Conductivity sensor fault | If conductivity sensor reports 0x11 for more than 2 consecutive reads. | "}, + { 206 , ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Reservoir Fill Timeout | DG dialysate fill runs out of time | If DG dialysate fill > 5 minutes. | "}, + { 207 , ALARM_ID_DG_FLOW_METER_CHECK_FAILURE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: FMP Flow Rate Error | DG flow meter check failure alarm | If integrated Volume To Load Cell Reading Percent > 0.1. | "}, + { 208 , ALARM_ID_HD_VENOUS_LINE_OCCLUSION , "HD | High Venous Pressure | Venous pressure is high. \n- Check venous bloodlines for kinks or clamps.\n- Check needle placement and/or access position.\n-Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. \n\nBlood Stop: Venous Pres. High | HD venous line occlusion fault | If the venous pressure is > set limit + 50 mmHg if HD is in treatment or pre-treatment mode. | "}, + { 209 , ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Flush Circ Error | DG drain circulation line timeout | If the integrated volume < 0.1 for more than 60 secs. | "}, + { 210 , ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED , "HD | Service Required: Hemodialysis Device | A non-critical problem was detected with the hemodialysis device.\n-Call service to report the issue and schedule a repair.\n\nHD Alarm (Low): Battery Fault | HD battery pack detected an error | If the battery pack status error is detected from the slave device I2C address 0x0B. | "}, + { 211 , ALARM_ID_HD_BLOOD_SITTING_WARNING , "HD | Approaching MAX Blood Pump Stop Time | The blood has been stopped for nearly 5 minutes.\n- You must resume treatment before the blood pump stop time timer expires. \n- If treatment is not resumed before the timer expires, treatment will be terminated without rinseback. \n\nBlood Stopped: Warning | Blood sitting too long warning (> 4 min) | During treatment stop sub-mode, if the blood is in the line for more than 4 minutes. | "}, + { 212 , ALARM_ID_HD_END_OF_TREATMENT_ALARM , "HD | Approaching MAX Blood Pump Stop Time | The blood has been stopped for nearly 5 minutes.\n- You must resume treatment before the blood pump stop time timer expires. \n- If treatment is not resumed before the timer expires, treatment will be terminated without rinseback.\n\nBlood Stopped: Warning | Blood sitting too long warning (> 4 min) | During treatment end paused state, if the blood is in the line for more than 4 minutes. | "}, + { 213 , ALARM_ID_HD_PRIME_COMPLETED_MEDIUM , "HD | Prime Complete - 30 MIN WARNING | The priming process completed 90 minutes ago. \n-Treatment must begin within 30 minutes or the pre-treatment process will be terminated. \n-Press OK to continue. \n\nProcess: Pre-Tx Prime Complete | HD prime completed medium priority alarm | In Pre-Treatment Recirculation for 90 minutes (escalation of alarm 226) | "}, + { 214 , ALARM_ID_AVAILABLE_30 , " | | \n\n | | | "}, + { 215 , ALARM_ID_AVAILABLE_31 , " | | \n\n | | | "}, + { 216 , ALARM_ID_HD_END_TREATMENT_TIMEOUT_ALARM , "HD | Treatment Complete | Dialysis treatment is complete.\n-Press OK to end treatment and rinseback.\n\nProcess: End of Dialysis Tx | HD end treatment sub-mode timeout alarm | If the treatment ended successfully. | "}, + { 217 , ALARM_ID_AVAILABLE_32 , " | | \n\n | | | "}, + { 218 , ALARM_ID_HD_SYRINGE_DETECTED , "HD | Syringe Detected | Heparin syringe was not removed from device.\n- Remove heparin syringe.\n-Press OK to continue.\n\nProcess: Remove Syringe | HD syringe detected alarm | If the syringe detection switch > 2.0 volts. | "}, + { 219 , ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED , "HD | Blood Stopped: Syringe Not Detected | There is a problem detecting a syringe in the heparin pump.\n- Confirm the heparin syringe is properly installed. \n-Press Ok to resume treatment.\n\nBlood Stop: Syringe Not Detected | HD syringe pump syringe removed alarm | If the syringe detection switch < 2.0 volts. | "}, + { 220 , ALARM_ID_DG_THD_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: THD RTD Comm | DG THd sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 221 , ALARM_ID_HD_EMPTY_SALINE_BAG , "HD | Blood Pump Stopped: Saline Bag Empty | The saline bag appears empty.\n- Check the saline bag and replace if empty. \n\nBlood Stop: Saline Bag Empty | HD Saline bag is empty | If the measured arterial pressure < -300.0 mmHg for more than 250 msec. | "}, + { 222 , ALARM_ID_HD_OCCLUSION_SENSOR_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: BP Occ Com | HD occlusion sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, + { 223 , ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Art. Pres. Com | HD arterial sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 224 , ALARM_ID_HD_TREATMENT_STOPPED_BY_USER , "HD | Blood Pump Stopped: Treatment Paused | Treatment has been stopped by used. \n- Press OK to resume treatment. \n-If treatment is not resumed within five minutes, treatment will be terminated without rinseback. \n\nBlood Stopped: Treatment Pause | Treatment stopped by user action - pressed stop button | If the user has pressed the stop button. | "}, + { 225 , ALARM_ID_HD_END_OF_TREATMENT_WARNING , "HD | Treatment Complete | Dialysis treatment is complete.\n-Press OK to end treatment and rinseback.\n\nProcess: End of Treatment | HD end of treatment warning | If the treatment duration has exceeded the prescribed treatment time entered by the user. | "}, + { 226 , ALARM_ID_HD_PRIME_COMPLETED_LOW_PRIORITY , "HD | Priming Complete | Priming is complete. \n-Treatment must begin within 120 minutes \nor the pre-treatment process will be terminated.\n-Press OK to continue. \n\nProcess: Pre-Tx Priming Complete | HD prime completed low priority alarm | Start of Pre-Treatment Recirculation - notifiy user to proceed to patient connection | "}, + { 227 , ALARM_ID_AVAILABLE_15 , " | | \n\n | | | "}, + { 228 , ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n -Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre-Tx Prime Timeout | HD time out on prime sub-mode purge air state. | During the pre-treatment prime state, if the prime saline purge air state exceeded 60 secs. | "}, + { 229 , ALARM_ID_HD_PRIME_DIALYSATE_DIALYZER_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n -Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre-Tx Prime Timeout | HD prime dialysate dialyzer time out alarm | If the priming of the dialyzer dialysate flow path has exceeded the time limit. | "}, + { 230 , ALARM_ID_HD_PRIME_DIALYSATE_BYPASS_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n -Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre-Tx Prime Timeout | HD prime dialysate bypass time out alarm | If the priming of the dialyzer bypass flow path has exceeded the time limit. | "}, + { 231 , ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE , "HD | Self Test: Pressure | A problem has been detected during self-test. \n- Confirm cartridge is properly installed without kinks or clamps. \n-Ensure all connections are secure. \n-Press OK to resume. \n- If problem persists, install a new cartridge.\n\nProcess: Pre-Tx Dry Self-Test | HD pre-treatment mode dry self-tests failure | If the following dry self tests have failed: 1. handleDrySelfTestPressureSensorsState 2. handleDrySelfTestPressureSensorsNormalState | "}, + { 232 , ALARM_ID_HD_PRE_TREATMENT_WET_LC_TEST_FAILURE , "HD | Self Test: Dialysate Flow Rate | A problem has been detected when measuring dialysate flow.\n- Confirm cartridge is properly installed and primed.\n- If problem persists, terminate treatment preparation and \n start over using a new cartridge.\n\nProcess: Pre-Tx Wet Self-Test | HD pre-treatment mode wet self-tests failure | If the following wet self tests have failed: 1. handleWetSelfTestPrimeCheckState 2. handleWetSelfTestFirstDisplacementVerifyState 3. handleWetSelfTestSecondDisplacementVerifyState | "}, + { 233 , ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Baro Cal CRC | DG barometric pressure sensor bad coefficients CRC | If the following happens: 1. The stored CRC in the sensor does not match the calculated CRC. 2. The CRC and coefficients have not been received from the sensor after 20 seconds from the power up. | "}, + { 234 , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_HIGH_RANGE , "DG | Incoming Water Pressure High | Incoming water pressure is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n-When the pressure is within target range RESUME button will be available. \n-Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Pres High | DG inlet water pressure is too high | If the inlet water pressure is > 80 psig. | "}, + { 235 , ALARM_ID_HD_TREATMENT_STOPPED_AFTER_RINSEBACK , "HD | Rinseback Complete | Rinseback is complete. \n-Follow facililty policy prior to disconnecting patient. \n-Press OK to continue. \n\nProcess: Rinseback Complete | HD in treatment stopped sub-mode after rinseback completed (no escalation) | If there is no active alarm and rinseback has completed. | "}, + { 236 , ALARM_ID_HD_INSTALL_NEW_CARTRIDGE , "HD | Self Test: Fluid Present | A problem has been detected during self-test. \n-Cartridges are single-use only and fluid is present.\n- Install new cartridge to resume.\n\nProcess: Pre-Tx Dry Self-Test | HD needs new cartridge to be installed | If the air trap sensor reported AIR and bubble sensor detected bubbles. | "}, + { 237 , ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n -Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre-Tx Prime Timeout | HD prime saline dialyzer time out alarm | If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "}, + { 238 , ALARM_ID_HD_NO_CARTRIDGE_LOADED , "HD | Cartridge Not Dectected | A problem has been detected during self-test. \n-Cartridge is not detected.\n- Confirm cartridge is properly installed.\n\nProcess: Pre-Tx Dry Self-Test | HD no cartridge loaded or installed improperly alarm | If the measured blood pump occlucsion pressure reading is < 5000 or > 24500. | "}, + { 239 , ALARM_ID_HD_CARTRIDGE_REMOVAL_FAILURE , "HD | Cartridge Still Detected | A problem has been detected during self-test. \n-Cartridge is still present or was unloaded incorrectly.\n- Confirm the cartridge has been fully removed.\n\nProcess: Post-Tx Remove Cartridge | HD fail to remove cartridge alarm | In the post treatment state, if the cartridge has not been removed. | "}, + { 240 , ALARM_ID_DG_BICARB_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Error During Prime | Conductivity out of range during prime.\n-Confirm that acid and bicarbonate concentrates are securely connected. \n- If empty, replace. \n-Treatment will need to be resumed when conductivity is within target range.\n\nDial. Gen: Bicarb Conc. Cond. | Bicarb conductivity out of range during bicarb pump check alarm | If the conductivity value for bicarbonate concentrate is out of range for more than 45 secs. | "}, + { 241 , ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Resv Drain Timeout | DG reservoir drain time out | If the DG reservoir drain is not complete in 120 secs. | "}, + { 242 , ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Resv Fill Timeout | DG reservoir fill time out | If the DG reservoir fill is not complete in 120 secs. | "}, + { 243 , ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Fluid Loss Detected | DG reservoir leak time out | If the reservoir level is drifted by 100 mL for more than 30 seconds. | "}, + { 244 , ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Temp Sensor Check | DG temperature sensors difference out of range | If any of the temperature sensors are out of the average of the sensors by more than 3 C. | "}, + { 245 , ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Heat Disinfect Temp TO | DG heat disinfect target temperature time out (could not reach to temperature) | If heating up to minimum temperature for heat disinfect failed after 4 hours. | "}, + { 246 , ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: RO Water Cond Error | DG chemical disinfect inlet conducitivty out of range | If CPo and CD2 conductivity values are above 100 uS/cm. | "}, + { 247 , ALARM_ID_AVAILABLE_7 , " | | \n\n | | | "}, + { 248 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE , "DG | Disinfection Interrupted | Dinsinfection terminated unexpectedly.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Chem Disinfect Proc | DG chemical disinfect out of target temperature | If TPo > 50 C after 1 second. | "}, + { 249 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE , "DG | Chemical Disinfectant Not Detected | Unable to sense proper chemical disinfectant.\n- Disinfection process has terminated.\n- Confirm chemical disinfectant is connected to the concentrate inlet. \n- Confirm chemical disinfectant container is not empty.\n-Restart disinfection.\n-If problem persists, call service to schedule a repair.\n\nCleaning: Chem Disinf PAA Cond | DG chemical disinfect out of target conductivity | If CD2 < 150 uS/cm or CD2 > 650 uS/cm after 10 seconds. | "}, + { 250 , ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID , "DG | Connect Chemical Disinfectant | Connect chemical disinfectant to the device. \n- Remove concentrate cap.\n-Keep dialysate cap on the device.\n-Place disinfectant straw in the disinfectant bottle. \n-Attach straw to concentrate connection and ensure connection is secure. \n-Press OK to continue.\n\nCleaning: Chem Disinf Connect PAA | Insert the acid to start chemical disinfect | Start of chemical disinfect | "}, + { 251 , ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Sys Rec NVRAM CRC | HD invalid system record | If the calculated CRC of the HD system record image does not match the expected CRC. | "}, + { 252 , ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Serv Rec NVRAM CRC | HD invalid service record | If the calculated CRC of the HD service record image does not match the expected CRC. | "}, + { 253 , ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Sys Rec NVRAM CRC | DG invalid system record | If the calculated CRC of the DG system record image does not match the expected CRC. | "}, + { 254 , ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Serv Rec NVRAM CRC | DG invalid service record | If the calculated CRC of the DG service record image does not match the expected CRC. | "}, + { 255 , ALARM_ID_HD_UI_COMPATIBILITY_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Compatibility | HD and UI software builds are not compatible | If the compatibility revision field of the UI is not equal to SW_COMPATIBILITY_REV. | "}, + { 256 , ALARM_ID_HD_DISINFECT_CHEM_FLUSH , "HD | Chemical Flush in Progress | Chemical flush in progress.\n-Please wait for the process to complete. \n-You will not be able to create a treatment until the process is finished.\n- To end this process, press STOP on the front of the device.\n\nCleaning: Chem Flush In Progress | DG flush started | If DG flush successfully started from the UI. | "}, + { 257 , ALARM_ID_AVAILABLE_8 , " | | \n\n | | | "}, + { 258 , ALARM_ID_AVAILABLE_9 , " | | \n\n | | | "}, + { 259 , ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Temp Sensors Error | HD temperatures out of range | If thermistor reports temperature > 80.0 C or < 0.0 C for a certain period of time. | "}, + { 260 , ALARM_ID_HD_UI_POST_FAILURE_SHASUM , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Image | UI POST Application Integrity (Sha256Sum) failure | If the UI POST reports a shasum faillure. | "}, + { 261 , ALARM_ID_HD_UI_POST_FAILURE_CANBUS , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI CAN Driver | UI POST CANBus failure | If the UI POST reports a can bus failure. | "}, + { 262 , ALARM_ID_AVAILABLE_18 , " | | \n\n | UI POST Display failure | If the UI POST reports a display failure. | "}, + { 263 , ALARM_ID_HD_UI_POST_FAILURE_TOUCH , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Touch Driver | UI POST Touch failure | If the UI POST reports a touch failure. | "}, + { 264 , ALARM_ID_HD_UI_POST_FAILURE_SDCARD , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI SD-Card | UI POST SD-Card failure | If the UI POST reports SD card failure. | "}, + { 265 , ALARM_ID_HD_UI_POST_FAILURE_RTC , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI RTC | UI POST RTC failure | If the UI POST reports RTC failure. | "}, + { 266 , ALARM_ID_HD_UI_POST_FAILURE_WIFI , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI WiFi | UI POST WiFi failure | If the UI POST reports WiFi failure. | "}, + { 267 , ALARM_ID_HD_UI_POST_FAILURE_BLUETOOTH , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Bluetooth | UI POST Bluetooth failure | If the UI POST reports bluetooth failure. | "}, + { 268 , ALARM_ID_HD_UI_POST_FAILURE_ETHERNET , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Ethernet | UI POST Ethernet failure | If the UI POST reports ethernet failure. | "}, + { 269 , ALARM_ID_HD_UI_POST_FAILURE_SOUND , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: UI Sound | UI POST Sound failure | If the UI POST reports sound failure. | "}, + { 270 , ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Proc Safestate | HD POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, + { 271 , ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Proc Safestate | DG POST Safety Shutdown failure | If the 24 volts power source is greater than 5.0 volts during safety shutdown self test state. If the 24 volts power source is less than 22.6 volts during safety shutdown self test recover state. | "}, + { 272 , ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A non-critical problem was detected with the hemodialysis device.\n-Call service to report the issue and schedule a repair.\n\nHD Alarm (Low): Fan Speed | HD Fan RPM out of range | If the fan RPM is out of Min/Max range. | "}, + { 273 , ALARM_ID_AVAILABLE_10 , " | | \n\n | | | "}, + { 274 , ALARM_ID_AVAILABLE_11 , " | | \n\n | | | "}, + { 275 , ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Arterial Press Range | HD arterial pressure sensor is reading out of range | If the arterial pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, + { 276 , ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Venous Press Range | HD venous pressure sensor is reading out of range | If the venous pressure > 2000.0 mmHg or < -1500.0 mmHg. | "}, + { 277 , ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Occlusion Sens Range | HD BP occlusion sensor is reading out of range | If the blood pump occlusion count is < 2000. | "}, + { 278 , ALARM_ID_HD_ACTIVE_RESERVOIR_WEIGHT_OUT_OF_RANGE , "HD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Reservoir Overfill | HD active reservoir weight out of range. | If the active reservoir weight is > 1900.0 g. | "}, + { 279 , ALARM_ID_DG_DIALYSATE_DRAIN_TIME_OUT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Reservoir Drain | DG dialysate drain time out | If the DG dialysate drain exceeded 120 seconds. | "}, + { 280 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_INVALID , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DRP Direction Fault | DG drain pump invalid direction | If the drain pump's direction is not 1 when draining. | "}, + { 281 , ALARM_ID_DG_ACID_BOTTLE_LOW_VOLUME , "DG | Acid Concentrate Low | The acid concentrate is low.\n- Replace acid concentrate container. \n\nDial. Gen: Acid Conc. Low | DG Acid concentration bottle low volume alarm | If the acid concentration bottle volume > 3240 (3340 - 100). | "}, + { 282 , ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME , "DG | Bicarb Concentrate Low | Bicarbonate concentrate is low.\n- Replace the bicarbonate concentrate container.\n\nDial. Gen: Bicarb Conc. Low | DG Bicarbonate concentration bottle low volume alarm | If the bicarbonate concentration bottle volume > 3680 (3780 - 100). | "}, + { 283 , ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: LC Range | DG load cells weight out of range | If the weight of the DG load cells > 4500.0 g or < 0.0 g. | "}, + { 284 , ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Redundant LC Check | DG load cells primary/back up drift out of range | If redundant load cells deviate by more than 60g after tare for 5 seconds. | "}, + { 285 , ALARM_ID_AVAILABLE_12 , " | | \n\n | | | "}, + { 286 , ALARM_ID_DG_CONCENTRATE_CAP_NOT_IN_PROPER_POSITION , "DG | Concentrate Connection Cap Removed | The concentrate connection cap was removed from the dialysate device during disinfection.\n- Disinfection terminated.\n-Replace cap before attempting disinfection again. \n\nCleaning: Conc Cap Removed | DG cap in wrong state | If the concentrate cap is not in the right position in the cleaning modes. | "}, + { 287 , ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Proc-FPGA Clock | HD processor clock speed checks against FPGA clock failure | If during initialization mode, the difference between the processor clock speed and the FPGA clock speed > 1. | "}, + { 288 , ALARM_ID_HD_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE , "HD | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: LC Drift Check | HD load cell inconsistency | If redundant load cells deviate from start to end of a reservoir use during treatment by more than 10g. | "}, + { 289 , ALARM_ID_DG_DIALYSATE_CAP_NOT_IN_PROPER_POSITION , "DG | Dialysate Connection Cap Removed | The dialysate connection cap was removed from the dialysate device during disinfection.\n- Disinfection terminated.\n-Replace cap before attempting disinfection again. \n\nCleaning: Dialysate Cap Removed | DG cap in wrong state | If the dialysate cap is not in the right position in the cleaning modes. | "}, + { 290 , ALARM_ID_HD_VENOUS_SENSOR_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Ven. Pres. Com | HD venous sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 291 , ALARM_ID_HD_DISINFECT_FLUSH , "HD | Flush In Progress | System flush is in progress\n-Please wait for the process to complete. \n-You will not be able to create a treatment until the process is finished.\n- To end this process, press STOP on the front of the device.\n\nCleaning: Flush In Progress | DG flush started | If DG flush successfully started from the UI. | "}, + { 292 , ALARM_ID_HD_DISINFECT_HEAT , "HD | Heat Disinfection in Progress | Heat disinfection is in progress.\n-Please wait for the process to complete. \n-You will not be able to create a treatment until the process is finished.\n- To end this process, press STOP on the front of the device.\n\nCleaning: Heat Disinf In Progress | DG heat disinfect started | If DG heat disinfect successfully started from the UI. | "}, + { 293 , ALARM_ID_HD_DISINFECT_CHEM , "HD | Chemical Disinfection in Progress | Chemical disinfection in progress.\n-Please wait for the process to complete. \n-You will not be able to create a treatment until the process is finished.\n- To end this process, press STOP on the front of the device.\n\nCleaning: Chem Disinfect In Progress | DG chem disinfect started | If DG flush successfully started from the UI. | "}, + { 294 , ALARM_ID_AVAILABLE_13 , " | | \n\n | | | "}, + { 295 , ALARM_ID_HD_UI_POST_FAILURE_CLOUDSYNC , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD POST: UI CloudSync | UI cloud sync POST failure | If the UI POST reports cloud sync failure. | "}, + { 296 , ALARM_ID_DG_TDI_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: TDi RTD Comm | DG TDi sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 297 , ALARM_ID_DG_TRO_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: TRo RTD Comm | DG TRo sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 298 , ALARM_ID_DG_BARO_SENSOR_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Baro Pres Comm | DG barometric sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, + { 299 , ALARM_ID_DG_INVALID_SERIAL_NUMBER , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG POST: Serial Number Check | DG invalid serial number | If the DG serial number is empty and does not have any characters. | "}, + { 300 , ALARM_ID_HD_INVALID_SERIAL_NUMBER , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST: Serial Number Check | HD invalid serial number | If the HD serial number is empty and does not have any characters. | "}, + { 301 , ALARM_ID_AVAILABLE_14 , " | | \n\n | | | "}, + { 302 , ALARM_ID_DG_CPU_RAM_ERROR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Processor RAM error | DG_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, + { 303 , ALARM_ID_DG_DRAIN_PUMP_DIRECTION_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: DRP Hall Commutation | DG drain pump direction FPGA fault | If the FPGA indicates an error for a certain period of time. | "}, + { 304 , ALARM_ID_HD_INVALID_USAGE_RECORD_CRC , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD POST: Usage Rec NVRAM CRC | HD invalid usage reocord | If the CRC of the HD usage record does not match the calculated CRC. | "}, + { 305 , ALARM_ID_HD_CPU_RAM_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nHD Fault: Processor RAM error | HD_CPU RAM error | If the RAM status indicates any of the following: Double bit error, Address decode failure, Address decode logic element failure, Read address parity failure, Write address parity failure. | "}, + { 306 , ALARM_ID_DG_CD1_CD2_CHECK_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CD1 CD2 Check | | CD1 and CD2 conductivity measurement during acid check is not within 5% of each other | "}, + { 307 , ALARM_ID_HD_AC_POWER_LOST_IN_TREATMENT , "HD | Power Loss | Treatment must be terminated due to a power loss.\n- Follow clinic instructions on when to initiate manual rinseback.\n-Check all electrical connections.\n- If power returns within 5 minutes of outage, \n- rinseback will be allowed.\n\nBlood Stop: Loss of AC Power | HD AC power lost alarm | The HD Software shall trigger an alarm if an AC power loss is detected while the HD system is in pre-treatment, treatment, or post-treatment mode. | "}, + { 308 , ALARM_ID_DG_CPI_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CPi Comm | DG CPi conductivity sensor transmits invalid characters | If the CPi conductivity sensor transmits invalid characters for a certain period of time. | "}, + { 309 , ALARM_ID_DG_CPO_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CPo Comm | DG CPo conductivity sensor transmits invalid characters | If the CPo conductivity sensor transmits invalid characters for a certain period of time. | "}, + { 310 , ALARM_ID_DG_CD1_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CD1 Comm | DG CD1 conductivity sensor transmits invalid characters | If the CD1 conductivity sensor transmits invalid characters for a certain period of time. | "}, + { 311 , ALARM_ID_DG_CD2_COND_SENSOR_INVALID_CHAR , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: CD2 Comm | DG CD2 conductivity sensor transmits invalid characters | If the CD2 conductivity sensor transmits invalid characters for a certain period of time. | "}, + { 312 , ALARM_ID_HD_DIAL_IN_FLOW_CHECK_FAILURE , "HD | Low Dialysate Flow | Dialysate flow rate is low. \n- Confirm dialysate concentrate connections are secure. \n- When the flow rates are within target range \nRESUME button will be available.\n-Press RESUME to continue.\n\nDial. Gen: Dialysate In Flow | The dialysate inlet flow is too low. | If the dialysate inlet flow < 10 mL/min (raw) while in treatment mode or pre-treatment mode after prime and DPi is running. | "}, + { 313 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_LOW , "DG | Disinfection: Water Temperature Low | Incoming water temperature is too low.\n-Disinfection has been terminated.\n- Check incoming water before initiating disinfection again. \n\nCleaning: Inlet Water Temp Low | DG cleaning mode inlet water temperature too low | If inlet water temperature is < 24 C. | "}, + { 314 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_HIGH , "DG | Disinfection: Water Pressure High | Incoming water pressure is too high. \n-Disinfection has been terminated.\n- Check incoming water before initiating disinfection again. \n\nCleaning: Inlet Water Press High | DG cleaning mode inlet water pressure too high | If inlet water temperature is > 80 psig. | "}, + { 315 , ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW , "DG | Disinfection: Water Pressure Low | Incoming water pressure is too low. \n-Disinfection has been terminated.\n- Check incoming water initiating disinfection again. \n\nCleaning: Inlet Water Press Low | DG cleaning mode inlet water pressure too low | If inlet water pressure is < 14 psig. | "}, + { 316 , ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Acid CP Pump Park | Acid concentrate pump did not park successfully | If the park took more than 1 second. | "}, + { 317 , ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: Bicarb CP Pump Park | Bicarb concentrate pump did not park successfully | If the park took more than 1 second. | "}, + { 318 , ALARM_ID_HD_AIR_PUMP_TIMEOUT , "HD | Air Trap Control Error | A problem has been detected with the air trap level control system. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue.\n\nHD Fault: Air Pump Timeout | HD Air Pump operation timeout | If air pump has been turned on for greater than 10s. | "}, + { 319 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE , "DG | Residual Chemical Sampling | A water sample is needed to confirm the \nabsence of residual chemical following disininfection. \n- Test sample according to facility policy. \n- Confirm absence of residual chemical disinfectant.\n\nCleaning: Chem Residual Sampling | Collect sample to check the chemical disinfectant acid | Chemical disinfect flush sample alarm is prompted. | "}, + { 320 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT , "DG | Chemical Residual Timeout | A chemical residual sample was not collected \n-within 30min of chemical flush.\n-To collect a sample for chemical residual, you must repeat the chemical flush.\n\nCleaning: Chem Residual Timeout | The user did not proceed with collecting chemical disinfect flush sample for more than 30 minutes | Chemical disinfect flush sample was not collected form more than 30 minutes. | "}, + { 321 , ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n-Treatment must be terminated.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair.\n\nDG Fault: UVo Error | Outlet reactor not healthy | If the outlet reactor are not healthy. | "}, + { 322 , ALARM_ID_HD_UI_POST_FAILURE_INVALID_YEAR , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n-Locate the ID code found in the bottom left corner of the alarm screen.\n-Call service to report the issue and schedule a repair. \n\nHD POST Alarm: UI Invalid Year | UI POST Invalid Year | If the UI POST reports a invalid year. | "}, // Num Alarm ID Device Display Title Instructions Description Trigger Condition }; #endif