Index: AlarmDefs.h =================================================================== diff -u -ra057d3752532ccb763b461fa8abc997d68848771 -raebb8c1e63747e6703e75e866419cca02856c31d --- AlarmDefs.h (.../AlarmDefs.h) (revision a057d3752532ccb763b461fa8abc997d68848771) +++ AlarmDefs.h (.../AlarmDefs.h) (revision aebb8c1e63747e6703e75e866419cca02856c31d) @@ -243,7 +243,7 @@ ALARM_ID_CONDUCTIVITY_SENSOR_FAULT = 205, ///< Conductivity sensor fault ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME = 206, ///< DG dialysate fill runs out of time ALARM_ID_DG_FLOW_METER_CHECK_FAILURE = 207, ///< DG flow meter check failure alarm - ALARM_ID__AVAILABLE_7 = 208, ///< Alarm ID available for use + ALARM_ID_HD_VENOUS_LINE_OCCLUSION = 208, ///< HD venous pressure occlusion alarm ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT = 209, ///< DG drain circulation line timeout ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED = 210, ///< HD battery pack detected an error ALARM_ID_BLOOD_SITTING_WARNING = 211, ///< Blood sitting too long warning (>4 min) @@ -661,7 +661,7 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID__AVAILABLE_7, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_LINE_OCCLUSION, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_MEDIUM, 800, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_SITTING_WARNING, 0, ALARM_ID_NO_ALARM }, @@ -930,7 +930,6 @@ { 3, ALARM_ID_DG_TEMPERATURE_SENSOR_ERROR_BIT_FAULT }, { 3, ALARM_ID_DG_LOAD_CELL_ADC_ERROR }, { 3, ALARM_ID_DG_FPGA_COMM_TIMEOUT }, - { 3, ALARM_ID__AVAILABLE_7 }, { 3, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT }, { 3, ALARM_ID_DG_CONCENTRATE_PUMP_FAULT }, { 3, ALARM_ID_CP1_SPEED_CONTROL_ERROR }, @@ -973,6 +972,7 @@ { 20, ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT }, { 21, ALARM_ID_OCCLUSION_BLOOD_PUMP }, { 36, ALARM_ID_PRIME_COMPLETED_HIGH }, + { 799, ALARM_ID_HD_VENOUS_LINE_OCCLUSION }, { 799, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE }, { 799, ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE }, { 799, ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT },