Index: AlarmDefs.h =================================================================== diff -u -rbb5c7b812666123859b3d05cf233871e157cb959 -rb2f429762993be505ecdb85b4836f9384c14ef26 --- AlarmDefs.h (.../AlarmDefs.h) (revision bb5c7b812666123859b3d05cf233871e157cb959) +++ AlarmDefs.h (.../AlarmDefs.h) (revision b2f429762993be505ecdb85b4836f9384c14ef26) @@ -8,7 +8,7 @@ * @file AlarmDefs.h * * @author (last) Dara Navaei -* @date (last) 11-Jan-2023 +* @date (last) 19-Jan-2023 * * @author (original) Sean * @date (original) 11-Feb-2020 @@ -354,6 +354,8 @@ ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT = 316, ///< DG acid concentrate pump park fault. ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT = 317, ///< DG bicarb concentrate pump part fault. ALARM_ID_HD_AIR_PUMP_TIMEOUT = 318, ///< HD Air Pump timeout alarm + ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE = 319, ///< DG chemical disinfect flush flush sample. + ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT = 320, ///< DG chemical disinfect flush sample timeout. NUM_OF_ALARM_IDS ///< Total number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -553,7 +555,7 @@ // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_FAULT, 0, ALARM_ID_NO_ALARM }, @@ -638,7 +640,7 @@ { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NEW_DG_OPERATION_MODE_MESSAGE_NOT_RECEIVE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_TEMPERATURE_IN_LOW_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_COMM_TOO_MANY_BAD_CRCS, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_CLOCK_SPEED_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, @@ -732,7 +734,7 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID, 0, ALARM_ID_NO_ALARM }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, @@ -803,6 +805,8 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE , TRUE, TRUE , TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_HD_AIR_PUMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT, 0, ALARM_ID_NO_ALARM }, }; // Priority Rank Fault DFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To /// Table of alarms and their rank. @@ -1033,6 +1037,7 @@ { 3, ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT }, { 3, ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT }, { 3, ALARM_ID_HD_AIR_PUMP_TIMEOUT }, + { 3, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { 4, ALARM_ID_END_OF_TREATMENT_HIGH }, { 5, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 6, ALARM_ID_HD_BLOOD_LEAK_DETECTED }, @@ -1086,6 +1091,7 @@ { 799, ALARM_ID_INLET_WATER_PRESSURE_IN_HIGH_RANGE }, { 799, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID }, { 799, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, + { 799, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE }, { 800, ALARM_ID_BLOOD_SITTING_WARNING }, { 801, ALARM_ID_END_OF_TREATMENT_ALARM }, { 802, ALARM_ID_PRIME_COMPLETED_MEDIUM }, @@ -1386,7 +1392,7 @@ { 234 , ALARM_ID_INLET_WATER_PRESSURE_IN_HIGH_RANGE , "DG | Inlet Water Pressure High | Inlet water pressure is high.\n- Check the incoming water for issues. | DG inlet water pressure is too high | If the inlet water pressure is > 80 psig. | "}, { 235 , ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK , "HD | Rinseback Complete | Rinseback has been completed. | HD in treatment stopped sub-mode after rinseback completed (no escalation) | If there is no active alarm and rinseback has completed. | "}, { 236 , ALARM_ID_INSTALL_NEW_CARTRIDGE , "HD | New Cartridge Needed | New cartridge needs to be installed. | HD needs new cartridge to be installed | If the air trap sensor reported AIR and bubble sensor detected bubbles. | "}, - { 237 , ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Prime Error | Call service to schedule a repair. | HD prime saline dialyzer time out alarm | This alarm is available. If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "}, + { 237 , ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Prime Error | Call service to schedule a repair. | HD prime saline dialyzer time out alarm | If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "}, { 238 , ALARM_ID_NO_CARTRIDGE_LOADED , "HD | Cartridge Needed | Cartridge not loaded or loaded improperly.\n- Check that a cartridge is properly installed. | HD no cartridge loaded or installed improperly alarm | If the measured blood pump occlucsion pressure reading is < 5000 or > 24500. | "}, { 239 , ALARM_ID_CARTRIDGE_REMOVAL_FAILURE , "HD | Cartridge Removal Error | Cartridge not unloaded, or unloaded improperly.\n- Check that the cartridge has been removed. | HD fail to remove cartridge alarm | In the post treatment state, if the cartridge has not been removed. | "}, { 240 , ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE , "DG | Dialysate Conductivity Error | Dialysate conductivity out of range.\n- Check to be sure the correct bicarbonate dialysate concentrate is connected. | Bicarb conductivity out of range during bicarb pump check alarm | If the conductivity value for bicarbonate concentrate is out of range for more than 45 secs. | "}, @@ -1470,7 +1476,9 @@ { 316 , ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT , "DG | Acid Concentrate Pump Park Fault | Call service to schedule a repair. | Acid concentrate pump did not park successfully | If the park took more than 1 second. | "}, { 317 , ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT , "DG | Bicarb Concentrate Pump Park Fault | Call service to schedule a repair. | Bicarb concentrate pump did not park successfully | If the park took more than 1 second. | "}, { 318 , ALARM_ID_HD_AIR_PUMP_TIMEOUT , "HD | Air Pump Operation Timeout | Call service to schedule a repair. | HD Air Pump operation timeout | If air pump has been turned on for greater than 10s. | "}, - // Num Alarm ID Device Display Title Instructions Description Trigger Condition + { 319 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE , "DG | Chemical Disinfect Flush | Collect Flush Sample. | Collect sample to check the chemical disinfectant acid | Chemical disinfect flush sample alarm is prompted. | "}, + { 320 , ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT , "DG | Chemical Disinfect Flush | Call service to schedule a repair. | The user did not proceed with collecting chemical disinfect flush sample for more than 30 minutes | Chemical disinfect flush sample was not collected form more than 30 minutes. | "}, + // Num Alarm ID Device Display Title Instructions Description Trigger Condition }; #endif