Index: AlarmDefs.h =================================================================== diff -u -rd2b33b8d231f0c8439db5973bc67238f8dde79bf -r0e35ca2221e177c2786fa883d13f2e2507f428df --- AlarmDefs.h (.../AlarmDefs.h) (revision d2b33b8d231f0c8439db5973bc67238f8dde79bf) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 0e35ca2221e177c2786fa883d13f2e2507f428df) @@ -268,7 +268,7 @@ ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT = 230, ///< HD prime dialysate bypass time out alarm ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE = 231, ///< HD pre-treatment mode dry pressure self-test failure ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE = 232, ///< HD pre-treatment mode wet self-test LC vs. LC failure - ALARM_ID__AVAILABLE_8 = 233, ///< Alarm ID available for use + ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC = 233, ///< DG barometric sensor coefficients bad CRC ALARM_ID_RTC_RAM_OPS_ERROR = 234, ///< RTC (i.e read time) or RAM operations failure (read or write) ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK = 235, ///< HD in treatment stopped sub-mode after rinseback completed (no escalation) ALARM_ID_INSTALL_NEW_CARTRIDGE = 236, ///< HD needs new cartridge to be installed @@ -687,7 +687,7 @@ { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID__AVAILABLE_8, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_RAM_OPS_ERROR, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE, 0, ALARM_ID_NO_ALARM }, @@ -952,6 +952,7 @@ { 3, ALARM_ID_DG_DIALYSATE_OR_CONC_CAP_NOT_IN_PROPER_POSITION }, { 3, ALARM_ID_RO_FLOW_TOO_LOW_WHILE_PRIMARY_HEATER_IS_ON }, { 3, ALARM_ID_DIALYSATE_FLOW_TOO_LOW_WHILE_TRIMMER_HEATER_IS_ON }, + { 3, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC }, { 4, ALARM_ID_END_OF_TREATMENT_HIGH }, { 5, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 6, ALARM_ID_HD_BLOOD_LEAK_DETECTED }, @@ -1029,7 +1030,6 @@ { 910, ALARM_ID_PRE_TREATMENT_WET_PRIME_TEST_FAILURE }, { 999, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, { 999, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, - { 999, ALARM_ID__AVAILABLE_8 }, { 999, ALARM_ID_RTC_RAM_OPS_ERROR }, { 999, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, { 999, ALARM_ID_INSTALL_NEW_CARTRIDGE },