Index: AlarmDefs.h =================================================================== diff -u -re0e4feaeddebc8f7f142502319c01efe2592a5b1 -r691732c7a9bcf0e3618d988ac66e663afdac8936 --- AlarmDefs.h (.../AlarmDefs.h) (revision e0e4feaeddebc8f7f142502319c01efe2592a5b1) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 691732c7a9bcf0e3618d988ac66e663afdac8936) @@ -1,17 +1,17 @@ /************************************************************************** * -* Copyright (c) 2019-2020 Diality Inc. - All Rights Reserved. +* Copyright (c) 2020-2022 Diality Inc. - All Rights Reserved. * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * -* @file AlarmDefs.h +* @file AlarmDefs.h * -* @author (last) Sean Nash -* @date (last) 14-Oct-2020 +* @author (last) Dara Navaei +* @date (last) 21-Mar-2022 * -* @author (original) Sean -* @date (original) 11-Feb-2020 +* @author (original) Sean +* @date (original) 11-Feb-2020 * ***************************************************************************/ @@ -39,7 +39,7 @@ ALARM_ID_STUCK_BUTTON_TEST_FAILED = 1, ///< Stuck button POST failure. Stop or Off button detected to be pressed for at least 1 second during test shortly after power up ALARM_ID_HD_FPGA_POST_TEST_FAILED = 2, ///< HD FPGA POST failure ALARM_ID_DG_FPGA_POST_TEST_FAILED = 3, ///< DG FPGA POST failure - ALARM_ID_WATCHDOG_POST_TEST_FAILED = 4, ///< HD Watchdog POST failure + ALARM_ID_HD_WATCHDOG_POST_TEST_FAILED = 4, ///< HD Watchdog POST failure ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED = 5, ///< DG Watchdog POST failure ALARM_ID_UI_COMM_POST_FAILED = 6, ///< UI communication POST failure. UI failed to communicate within a reasonable time after power up ALARM_ID_RTC_CONFIG_ERROR = 7, ///< Real-time clock configuration error @@ -101,10 +101,10 @@ ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT = 63, ///< FPGA reports failure reading arterial pressure sensor ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT = 64, ///< FPGA reports failure reading venous pressure sensor ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT = 65, ///< HD requests DG command with invalid parameter fault - ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID = 66, ///< DG/HD NV data management overall group record CRC invalid + ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE = 66, ///< HD blood leak sensor set point set failure ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE = 67, ///< HD blood pump occlusion self-test failure alarm - ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE = 68, ///< HD dialysate inlet pump occlusion self-test failure alarm - ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE = 69, ///< HD dialysate outlet pump occlusion self-test failure alarm + ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE = 68, ///< HD active reservoir recirculation out of range + ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD = 69, ///< HD blood leak sensor invalid calibration record ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE = 70, ///< HD arterial pressure self-test failure alarm ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE = 71, ///< HD venous pressure self-test failure alarm ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE = 72, ///< HD blood flow meter status check self-test failure alarm @@ -120,28 +120,28 @@ ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR = 82, ///< HD syringe pump DAC write failure ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR = 83, ///< HD syringe pump is running while the BP is off ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR = 84, ///< HD venous pressure sensor not being read - ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE = 85, ///< HD venous pressure sensor temperature out of range error + ALARM_ID_PUMP_TRACK_LATCH_OPENED = 85, ///< HD pump track latch opened alarm ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR = 86, ///< HD BP occlusion sensor not being read - ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR = 87, ///< HD DPi occlusion sensor not being read - ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR = 88, ///< HD DPo occlusion sensor not being read + ALARM_ID_DG_HEATING_INVALID_CAL_RECORD = 87, ///< DG heating invalid calibration record + ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE = 88, ///< DG concentrate pumps hall sensor out of range ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR = 89, ///< HD BP occlusion sensor error - ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR = 90, ///< HD DPi occlusion sensor error - ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR = 91, ///< HD DPo occlusion sensor error - ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR = 92, ///< HD blood flow sensor not being read - ALARM_ID_HD_BP_FLOW_SENSOR_ERROR = 93, ///< HD blood flow sensor error - ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR = 94, ///< HD dialysate flow sensor not being read - ALARM_ID_HD_DP_FLOW_SENSOR_ERROR = 95, ///< HD dialysate flow sensor error - ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR = 96, ///< HD blood flow sensor not being read - slow packet - ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR = 97, ///< HD dialysate flow sensor not being read - slow packet + ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT = 90, ///< DG dialysate temperature sensor drift timeout. + ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE = 91, ///< HD No dialysate flow data receive in the last 3 seconds + ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS = 92, ///< DG conductivity sensor bad status. + ALARM_ID____AVAILABLE_15 = 93, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_16 = 94, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_17 = 95, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_18 = 96, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_19 = 97, ///< This alarm ID is available for use ALARM_ID_HD_BATTERY_COMM_FAULT = 98, ///< HD battery communication fault ALARM_ID_HD_SYRINGE_PUMP_STALL = 99, ///< HD syringe pump stall alarm ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT = 100, ///< HD no cartridge self-test timeout ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT = 101, ///< HD dry self-test timeout ALARM_ID_RTC_COMM_ERROR = 102, ///< Real-time clock communication error - ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR = 103, ///< Manufacturing record CRC failure + ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID = 103, ///< HD non-volatile calibration group invalid record CRC ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS = 104, ///< Air trap level sensors reporting illegal combination of air/fluid - ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID = 105, ///< DG/HD NV data management individual record CRC invalid - ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID = 106, ///< DG/HD NV data management individual record time invalid + ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID = 105, ///< DG non-volatile system group invalid record CRC + ALARM_ID____AVAILABLE_20 = 106, ///< This alarm ID is available for use ALARM_ID_DG_RESTARTED_FAULT = 107, ///< HD reports DG restarted fault ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR = 108, ///< HD syringe pump ADC error ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR = 109, ///< HD syringe pump volume check error @@ -152,15 +152,15 @@ ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE = 114, ///< HD venous air bubble detector self-test failure ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE = 115, ///< DG temperature sensor out of range ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE = 116, ///< DG temperature sensor ADC out of range - ALARM_ID_DG_PRIMARY_HEATER_INTERNAL_TEMP_OUT_OF_RANGE = 117, ///< DG primary heater internal temperature out of range - ALARM_ID_DG_PRIMARY_HEATER_CJ_TEMP_OUT_OF_RANGE = 118, ///< DG primary heater cold junction temperature out of range - ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE = 119, ///< DG trimmer heater internal temperature out of range - ALARM_ID_DG_TRIMMER_HEATER_CJ_TEMP_OUT_OF_RANGE = 120, ///< DG trimmer heater cold junction temperature out of range + ALARM_ID____AVAILABLE_28 = 117, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_29 = 118, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_30 = 119, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_31 = 120, ///< This alarm ID is available for use ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE = 121, ///< DG main primary heater voltage out of range ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE = 122, ///< DG small primary heater voltage out of range ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE = 123, ///< DG trimmer heater voltage out of range ALARM_ID_END_OF_TREATMENT_HIGH = 124, ///< HD end of treatment alarm (high priority - user still not acting to end treatment) - ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK = 125, ///< Blood sitting too long after treatment stopped by user alarm (>10 min) + ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK = 125, ///< Blood sitting too long after treatment stopped by user alarm (>5 min) ALARM_ID_HD_BLOOD_LEAK_DETECTED = 126, ///< HD blood leak detected alarm ALARM_ID_VENOUS_PRESSURE_LOW = 127, ///< Venous pressure too low during treatment ALARM_ID_HD_VENOUS_BUBBLE_DETECTED = 128, ///< HD venous air bubble detected alarm @@ -178,8 +178,8 @@ ALARM_ID_DG_COMM_TIMEOUT = 140, ///< Dialysate generator communication timeout ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT = 141, ///< Air trap fill timeout during treatment ALARM_ID_OCCLUSION_BLOOD_PUMP = 142, ///< Blood pump occlusion detected - ALARM_ID_OCCLUSION_DIAL_IN_PUMP = 143, ///< Dialysate inlet pump occlusion detected - ALARM_ID_OCCLUSION_DIAL_OUT_PUMP = 144, ///< Dialysate outlet pump occlusion detected + ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT = 143, ///< DG dialysate temperature sensors drift timeout. + ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC = 144, ///< DG software configuration record invalid CRC. ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE = 145, ///< Concentrate conductivity after adding acid out of range alarm ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE = 146, ///< Dialysate conductivity out of range ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT = 147, ///< DG dialysate generation conductivity fault alarm @@ -190,33 +190,33 @@ ALARM_ID_INLET_WATER_LOW_PRESSURE = 152, ///< Inlet water pressure too low ALARM_ID_PRIME_COMPLETED_HIGH = 153, ///< HD prime completed high priority alarm ALARM_ID_NVDATA_EEPROM_OPS_FAILURE = 154, ///< EEPROM operations (read, write, erase) failure - ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR = 155, ///< Service record CRC failure + ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC = 155, ///< DG software configuration record invalid CRC ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR = 156, ///< HW usage data (treatment time in HD and total consumed water in DG) failure - ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR = 157, ///< Calibration record CRC failure - ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK = 158, ///< Blood pump failed flow vs. motor speed check. Mismatch with flow rate and rate implied by motor speed - ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK = 159, ///< Dialysate inlet pump failed flow vs. motor speed check. Mismatch with flow rate and rate implied by motor speed + ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT = 157, ///< DG chemical disinfect prime acid line timeout. + ALARM_ID____AVAILABLE_24 = 158, ///< This alarm ID is available for use + ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK = 159, ///< Dialysate inlet pump failed flow vs. motor speed check. ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH = 160, ///< Blood pump rotor speed too high - ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW = 161, ///< Blood flow sensor signal strength too low - ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW = 162, ///< Dialysate flow sensor signal strength too low + ALARM_ID____AVAILABLE_26 = 161, ///< This alarm ID is available for use + ALARM_ID____AVAILABLE_27 = 162, ///< This alarm ID is available for use ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM = 163, ///< HD sees primary load cell for reservoir 1 change too much too fast - ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM = 164, ///< HD sees primary load cell for reservoir 1 change too much too fast + ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM = 164, ///< HD sees primary load cell for reservoir 2 change too much too fast ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM = 165, ///< HD in treatment rinseback operation timeout ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM = 166, ///< HD in treatment re-circ sub-mode for too long ALARM_ID_CARTRIDGE_DOOR_OPENED = 167, ///< HD cartridge door opened alarm - ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH = 168, ///< HD dialysate temperature too high alarm - ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW = 169, ///< HD dialysate temperature too low alarm + ALARM_ID_HD_ACTIVE_RESERVOIR_DEPLETION_TIME_OUT = 168, ///< HD active reservoir depletion timeout. + ALARM_ID_DIALYSATE_FLOW_RATE_OUT_OF_RANGE = 169, ///< Dialysate flow rate out of range ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY = 170, ///< HD syringe empty alarm ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION = 171, ///< HD syringe pump occlusion alarm ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM = 172, ///< HD syringe pump not enough Heparin alarm ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED = 173, ///< HD arterial air bubble detected alarm ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK = 174, ///< HD arterial air bubble detected rinseback alarm ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR = 175, ///< HD pump direction status error - ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH = 176, ///< HD active reservoir is full during treatment and DG not ready to switch reservoirs. + ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH = 176, ///< HD active reservoir is full during treatment and DG not ready to switch reservoirs. // TODO remove this alarm ALARM_ID_DG_SOFTWARE_FAULT = 177, ///< DG software fault. Software found itself in an unexpected state ALARM_ID_HD_COMM_TIMEOUT = 178, ///< HD communication timeout ALARM_ID_DG_FPGA_COMM_TIMEOUT = 179, ///< DG FPGA communication down for too long ALARM_ID_DG_LOAD_CELL_ADC_ERROR = 180, ///< DG load cell ADC error - ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE = 181, ///< DG load cells weight out of range before tare + ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE = 181, ///< DG load cells weight out of range for tare ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION = 182, ///< DG load cells invalid calibration ALARM_ID_DG_INVALID_LOAD_CELL_VALUE = 183, ///< DG invalid load cell value ALARM_ID_UV_REACTOR_NOT_HEALTHY = 184, ///< Inlet or Outlet UV reactor not healthy @@ -229,7 +229,7 @@ ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE = 191, ///< DG flow rate out of upper range ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE = 192, ///< DG flow rate out of lower range ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE = 193, ///< RO pump flow rate out of range - ALARM_ID_RO_PUMP_OFF_FAULT = 194, ///< DG RO pump off fault + ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE = 194, ///< DG RO pump duty cycle out of range ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE = 195, ///< DG RO pump pressure out of range ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT = 196, ///< DG temperature sensor error flag fault. ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT = 197, ///< DG temperature sensors ADC fault @@ -243,7 +243,7 @@ ALARM_ID_CONDUCTIVITY_SENSOR_FAULT = 205, ///< Conductivity sensor fault ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME = 206, ///< DG dialysate fill runs out of time ALARM_ID_DG_FLOW_METER_CHECK_FAILURE = 207, ///< DG flow meter check failure alarm - ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT = 208, ///< DG heaters on with no flow time out + ALARM_ID_DG_PRIMARY_HEATER_ON_WITH_NO_FLOW_TIMEOUT = 208, ///< DG primary heater on with no flow time out ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT = 209, ///< DG drain circulation line timeout ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED = 210, ///< HD battery pack detected an error ALARM_ID_BLOOD_SITTING_WARNING = 211, ///< Blood sitting too long warning (>4 min) @@ -272,8 +272,8 @@ ALARM_ID_RTC_RAM_OPS_ERROR = 234, ///< RTC (i.e read time) or RAM operations failure (read or write) ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK = 235, ///< HD in treatment stopped sub-mode after rinseback completed (no escalation) ALARM_ID_INSTALL_NEW_CARTRIDGE = 236, ///< HD needs new cartridge to be installed - ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY = 237, ///< HD cartridge installed improperly alarm - ALARM_ID_NO_CARTRIDGE_LOADED = 238, ///< HD no cartridge loaded alarm + ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT = 237, ///< HD prime saline dialyzer time out alarm + ALARM_ID_NO_CARTRIDGE_LOADED = 238, ///< HD no cartridge loaded or installed improperly alarm ALARM_ID_CARTRIDGE_REMOVAL_FAILURE = 239, ///< HD fail to remove cartridge alarm ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE = 240, ///< Bicarb conductivity out of range during bicarb pump check alarm ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT = 241, ///< DG reservoir drain time out @@ -286,28 +286,45 @@ ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT = 248, ///< DG chemical disinfect could not reach to target temperature ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT = 249, ///< DG chemical disinfect inlet pressure and temperature sensors out of range ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT = 250, ///< DG chemical disinfect inlet conductivity and temperature out of range - ALARM_ID_HD_INVALID_SYSTEM_RECORD = 251, ///< HD invalid system record - ALARM_ID_HD_INVALID_SERVICE_RECORD = 252, ///< HD invalid service record - ALARM_ID_DG_INVALID_SYSTEM_RECORD = 253, ///< DG invalid system record - ALARM_ID_DG_INVALID_SERVICE_RECORD = 254, ///< DG invalid service record + ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC = 251, ///< HD invalid system record + ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC = 252, ///< HD invalid service record + ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC = 253, ///< DG invalid system record + ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC = 254, ///< DG invalid service record ALARM_ID_HD_UI_COMPATIBILITY_ERROR = 255, ///< HD and UI software builds are not compatible ALARM_ID_HD_DG_COMPATIBILITY_ERROR = 256, ///< HD and DG software builds are not compatible ALARM_ID_DG_FPGA_POWER_OUT_TIMEOUT = 257, ///< DG FPGA power out timeout ALARM_ID_HD_FPGA_POWER_OUT_TIMEOUT = 258, ///< HD FPGA power out timeout ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE = 259, ///< HD temperatures out of range - ALARM_ID_UI_POST_FAILURE_FILESYSTEM = 260, ///< UI POST File System Integrity failure. - ALARM_ID_UI_POST_FAILURE_CANBUS = 261, ///< UI POST CANBus failure. - ALARM_ID_UI_POST_FAILURE_DISPLAY = 262, ///< UI POST Display failure. - ALARM_ID_UI_POST_FAILURE_TOUCH = 263, ///< UI POST Touch failure. - ALARM_ID_UI_POST_FAILURE_SDCARD = 264, ///< UI POST SD-Card failure. - ALARM_ID_UI_POST_FAILURE_RTC = 265, ///< UI POST RTC failure. - ALARM_ID_UI_POST_FAILURE_WIFI = 266, ///< UI POST WiFi failure. - ALARM_ID_UI_POST_FAILURE_BLUETOOTH = 267, ///< UI POST Bluetooth failure. - ALARM_ID_UI_POST_FAILURE_ETHERNET = 268, ///< UI POST Ethernet failure. - ALARM_ID_UI_POST_FAILURE_SOUND = 269, ///< UI POST Sound failure. - ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED = 270, ///< HD Watchdog POST failure - ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED = 271, ///< HD Watchdog POST failure + ALARM_ID_UI_POST_FAILURE_SHASUM = 260, ///< UI POST Application Integrity (Sha256Sum) failure + ALARM_ID_UI_POST_FAILURE_CANBUS = 261, ///< UI POST CANBus failure + ALARM_ID_UI_POST_FAILURE_DISPLAY = 262, ///< UI POST Display failure + ALARM_ID_UI_POST_FAILURE_TOUCH = 263, ///< UI POST Touch failure + ALARM_ID_UI_POST_FAILURE_SDCARD = 264, ///< UI POST SD-Card failure + ALARM_ID_UI_POST_FAILURE_RTC = 265, ///< UI POST RTC failure + ALARM_ID_UI_POST_FAILURE_WIFI = 266, ///< UI POST WiFi failure + ALARM_ID_UI_POST_FAILURE_BLUETOOTH = 267, ///< UI POST Bluetooth failure + ALARM_ID_UI_POST_FAILURE_ETHERNET = 268, ///< UI POST Ethernet failure + ALARM_ID_UI_POST_FAILURE_SOUND = 269, ///< UI POST Sound failure + ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED = 270, ///< HD POST Safety Shutdown failure + ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED = 271, ///< DG POST Safety Shutdown failure ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE = 272, ///< HD Fan RPM out of range + ALARM_ID_HD_BLOOD_FLOW_OUT_OF_RANGE = 273, ///< HD measured blood pump flow rate is out of range + ALARM_ID_HD_DIAL_IN_FLOW_OUT_OF_RANGE = 274, ///< HD measured dialysate inlet pump flow rate is out of range + ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE = 275, ///< HD arterial pressure sensor is reading out of range + ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE = 276, ///< HD venous pressure sensor is reading out of range + ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE = 277, ///< HD BP occlusion sensor is reading out of range + ALARM_ID_HD_ACTIVE_RESERVOIR_WEIGHT_OUT_OF_RANGE = 278, ///< HD active reservoir weight out of range. + ALARM_ID_DG_DIALYSATE_DRAIN_TIME_OUT = 279, ///< DG dialysate drain time out + ALARM_ID_HD_ARTERIAL_PRESSURE_READ_TIMEOUT_ERROR = 280, ///< HD arterial pressure sensor read timeout error + ALARM_ID_DG_ACID_BOTTLE_LOW_VOLUME = 281, ///< Acid concentration bottle low volume alarm + ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME = 282, ///< Bicarbonate concentration bottle low volume alarm + ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE = 283, ///< DG load cells weight out of range + ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE = 284, ///< DG load cells primary/back up drift out of range + ALARM_ID_HD_TREATMENT_RECIRC_TIMEOUT_WARNING = 285, ///< HD treatment recirculate timeout warning + ALARM_ID_HD_TREATMENT_RINSEBACK_TIMEOUT_WARNING = 286, ///< HD treatment rinseback complete timeout warning + ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE = 287, ///< HD processor clock speed checks against FPGA clock failure + ALARM_ID_DG_TRIMMER_HEATER_ON_WITH_NO_FLOW_TIMEOUT = 288, ///< DG trimmer heater on with flow timeout + ALARM_ID_DG_DIALYSATE_OR_CONC_CAP_NOT_IN_PROPER_POSITION = 289, ///< DG dialysate or concentrate caps not closed NUM_OF_ALARM_IDS ///< Total number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -374,14 +391,14 @@ ALARM_STATE_FLAG_BIT_POS_NO_RESUME = 3, ///< The "resume" user recovery option is disabled ALARM_STATE_FLAG_BIT_POS_NO_RINSEBACK = 4, ///< The "rinseback" user recovery option is disabled ALARM_STATE_FLAG_BIT_POS_NO_END_TREATMENT = 5, ///< The "end treatment" user recovery option is disabled - ALARM_STATE_FLAG_BIT_POS_NO_NEW_TREATMENT = 6, ///< A new treatment may not be started without cycling power to system - ALARM_STATE_FLAG_BIT_POS_USER_MUST_ACK = 7, ///< The "ok" user recovery option is enabled + ALARM_STATE_FLAG_BIT_POS_UNUSED_1 = 6, ///< Reserved + ALARM_STATE_FLAG_BIT_POS_OK_BUTTON_ONLY = 7, ///< The "ok" user recovery option is enabled ALARM_STATE_FLAG_BIT_POS_ALARMS_TO_ESCALATE = 8, ///< One or more active alarms will escalate in time ALARM_STATE_FLAG_BIT_POS_ALARMS_SILENCED = 9, ///< Alarms have been temporarily silenced by user ALARM_STATE_FLAG_BIT_POS_LAMP_ON = 10, ///< Alarm lamp is currently on (for syncing to UI) - ALARM_STATE_FLAG_BIT_POS_UNUSED_1 = 11, ///< Reserved - ALARM_STATE_FLAG_BIT_POS_UNUSED_2 = 12, ///< Reserved - ALARM_STATE_FLAG_BIT_POS_UNUSED_3 = 13, ///< Reserved + ALARM_STATE_FLAG_BIT_POS_UNUSED_2 = 11, ///< Reserved + ALARM_STATE_FLAG_BIT_POS_UNUSED_3 = 12, ///< Reserved + ALARM_STATE_FLAG_BIT_POS_DIALYSATE_RECIRC = 13, ///< Dialysate recirculation is diabled ALARM_STATE_FLAG_BIT_POS_NO_MINIMIZE = 14, ///< Prevent user from minimizing alarm window ALARM_STATE_FLAG_BIT_POS_TOP_CONDITION = 15, ///< The top alarm's condition is still being detected NUM_OF_ALARM_STATE_FLAG_BIT_POS = 16 ///< The number of alarm state flag bit positions @@ -403,9 +420,8 @@ BOOL alarmNoResume; ///< Alarm prevents treatment resume BOOL alarmNoRinseback; ///< Alarm prevents rinseback BOOL alarmNoEndTreatment; ///< Alarm prevents ending treatment - BOOL alarmNoNewTreatment; ///< Alarm prevents any new treatments BOOL alarmNoDialysateRecirc; ///< Alarm prevents dialysate re-circulation - BOOL alarmUserAckRequired; ///< Alarm requires user acknowledgment + BOOL alarmClearOnly; ///< Clear only this alarm on user acknowledgment BOOL alarmTreatmentLog; ///< Log alarm to treatment log if active during treatment ALARM_ID_T alarmID; ///< Alarm ID U32 alarmEscalatesAfter; ///< Time (s) after start when alarm will escalate if not cleared (zero indicates no escalation) @@ -425,289 +441,317 @@ /// Table of alarms and their static properties. const ALARM_T ALARM_TABLE[] = -{ // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoNew NoRcr UsrAck TxLog ID Escalate In Escalate To - { ALARM_PRIORITY_NONE, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NO_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_STUCK_BUTTON_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_WATCHDOG_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_COMM_POST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_CONFIG_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_RTC_OR_TIMER_ACCURACY_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_PRESSURE_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACID_CONCENTRATE_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETERS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SOFTWARE_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_WATCHDOG_EXPIRED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_COMM_TOO_MANY_BAD_CRCS, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_CAN_MESSAGE_NOT_ACKED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_UF_RATE_TOO_HIGH_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_UF_VOLUME_ACCURACY_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_VALVE_CONTROL_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_CRITICAL_DATA_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CRITICAL_DATA_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETER_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETER_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_HOMING_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_NOT_FUNCTIONAL, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_FLOW_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DP_FLOW_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BATTERY_COMM_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_STALL, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_COMM_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE, ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESTARTED_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_BUBBLE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_PRIMARY_HEATER_INTERNAL_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_PRIMARY_HEATER_CJ_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_TRIMMER_HEATER_CJ_TEMP_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 4, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 5, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 6, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE, TRUE, FALSE, FALSE, TRUE, FALSE, TRUE, ALARM_ID_HD_BLOOD_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 8, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_VENOUS_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 9, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 10, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_VENOUS_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 12, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ARTERIAL_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 13, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ARTERIAL_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 14, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_FLUID_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 15, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_FLUID_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 16, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SHOCK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 16, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_SHOCK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_EXCESSIVE_TILT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_EXCESSIVE_TILT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 18, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_AC_POWER_LOST, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 19, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 20, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_OCCLUSION_BLOOD_PUMP, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_OCCLUSION_DIAL_IN_PUMP, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_OCCLUSION_DIAL_OUT_PUMP, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 22, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 23, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 24, FALSE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 26, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 28, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 30, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 32, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 34, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_PRESSURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 36, FALSE, FALSE, FALSE, TRUE, FALSE, TRUE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_DOOR_OPENED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_SOFTWARE_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_ADC_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UV_REACTOR_NOT_HEALTHY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONCENTRATE_PUMP_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CP1_SPEED_CONTROL_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CP2_SPEED_CONTROL_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DRAIN_PUMP_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DRAIN_PUMP_OFF_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_OFF_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_BAD_INLET_WATER_QUALITY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INLET_WATER_PRESSURE_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 800, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_SITTING_WARNING, ALM_ESC_1_MIN, ALARM_NO_RINSEBACK }, - { ALARM_PRIORITY_MEDIUM, 801, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_ALARM, ALM_ESC_5_MIN, ALARM_ID_END_OF_TREATMENT_HIGH }, - { ALARM_PRIORITY_MEDIUM, 802, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_MEDIUM, ALM_ESC_30_MIN, ALARM_ID_PRIME_COMPLETED_HIGH }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_END_TREATMENT_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_DETECTED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_CHARGE_TOO_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 900, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_EMPTY_SALINE_BAG, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 901, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIALYSATE_TEMPERATURE_HIGH, ALM_ESC_5_MIN, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH }, - { ALARM_PRIORITY_LOW, 902, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIALYSATE_TEMPERATURE_LOW, ALM_ESC_5_MIN, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW }, - { ALARM_PRIORITY_LOW, 903, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_BY_USER, ALM_ESC_4_MIN, ALARM_ID_BLOOD_SITTING_WARNING }, - { ALARM_PRIORITY_LOW, 904, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING, ALM_ESC_5_MIN, ALARM_ID_END_OF_TREATMENT_ALARM }, - { ALARM_PRIORITY_LOW, 905, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY, ALM_ESC_90_MIN, ALARM_ID_PRIME_COMPLETED_MEDIUM }, - { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRIME_PURGE_AIR_TIME_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, FALSE, FALSE, FALSE, ALARM_ID_RTC_BATTERY_LOW, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_RTC_RAM_OPS_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_NO_CARTRIDGE_LOADED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_INVALID_SYSTEM_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_INVALID_SERVICE_RECORD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_COMPATIBILITY_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DG_COMPATIBILITY_ERROR, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_POWER_OUT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_POWER_OUT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_FILESYSTEM, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CANBUS, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_DISPLAY, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_TOUCH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SDCARD, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_RTC, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_WIFI, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_BLUETOOTH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_ETHERNET, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_SOUND, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, -}; // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoNew NoRcr UsrAck TxLog ID Escalate In Escalate To +{ // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_NONE, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NO_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_STUCK_BUTTON_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_WATCHDOG_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_COMM_POST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_CONFIG_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETER_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_RTC_OR_TIMER_ACCURACY_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_INTEGRITY_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_ALARM_AUDIO_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_PRESSURE_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_COND_SENSORS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_LINE_VOLUME_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIRS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACID_CONCENTRATE_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BICARB_CONCENTRATE_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETERS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SOFTWARE_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MC_CURRENT_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_OFF_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MC_DIRECTION_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_ROTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_WATCHDOG_EXPIRED, 0, ALARM_ID_NO_ALARM },//add DG version + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_COMM_TOO_MANY_BAD_CRCS, 0, ALARM_ID_NO_ALARM },//add DG version + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_CAN_MESSAGE_NOT_ACKED, 0, ALARM_ID_NO_ALARM },//add DG version + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_UF_RATE_TOO_HIGH_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_UF_VOLUME_ACCURACY_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_VALVE_CONTROL_FAILURE, 0, ALARM_ID_NO_ALARM },//add DG version + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIAL_OUT_PUMP_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_CRITICAL_DATA_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CRITICAL_DATA_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ACCELEROMETER_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_ACCELEROMETER_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_HOMING_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_TRANSITION_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_NOT_FUNCTIONAL, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_STATUS_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_OVER_TRAVEL_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_PUMP_TRACK_LATCH_OPENED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_15, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_16, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_17, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_18, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_19, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BATTERY_COMM_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_STALL, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_COMM_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE, TRUE, TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE, ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_20, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESTARTED_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SPEED_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_NOT_STOPPED_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_BUBBLE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID____AVAILABLE_28, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID____AVAILABLE_29, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID____AVAILABLE_30, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID____AVAILABLE_31, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, FALSE, ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 4, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_HIGH, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 5, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 6, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE, TRUE, FALSE, TRUE, FALSE, TRUE, ALARM_ID_HD_BLOOD_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 8, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_VENOUS_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 9, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 10, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_VENOUS_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 11, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_VENOUS_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 12, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ARTERIAL_PRESSURE_LOW, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 13, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ARTERIAL_PRESSURE_HIGH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 14, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_FLUID_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 15, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_FLUID_LEAK_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 16, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_SHOCK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 16, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_SHOCK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_EXCESSIVE_TILT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_EXCESSIVE_TILT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 18, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_HD_AC_POWER_LOST, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 19, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 20, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 21, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_OCCLUSION_BLOOD_PUMP, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 21, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 21, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 22, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 23, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 24, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_PRESSURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 36, FALSE, FALSE, FALSE, TRUE, FALSE, TRUE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_HIGH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID____AVAILABLE_24, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID____AVAILABLE_26, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID____AVAILABLE_27, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_DOOR_OPENED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_ACTIVE_RESERVOIR_DEPLETION_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DIALYSATE_FLOW_RATE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_HD_ARTERIAL_BUBBLE_DETECTED_RINSEBACK, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PUMP_DIRECTION_STATUS_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_RESERVOIR_FULL_AND_DG_NOT_READY_TO_SWITCH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_SOFTWARE_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_COMM_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_ADC_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UV_REACTOR_NOT_HEALTHY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CONCENTRATE_PUMP_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CP1_SPEED_CONTROL_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CP2_SPEED_CONTROL_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DRAIN_PUMP_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DRAIN_PUMP_OFF_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEATERS_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_BAD_INLET_WATER_QUALITY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INLET_WATER_PRESSURE_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE, TRUE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_PRIMARY_HEATER_ON_WITH_NO_FLOW_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 800, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_SITTING_WARNING, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 801, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 802, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_MEDIUM, ALM_ESC_30_MIN, ALARM_ID_PRIME_COMPLETED_HIGH }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_TREATMENT_TIMEOUT_ALARM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_DETECTED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH , 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_CHARGE_TOO_LOW, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 900, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_EMPTY_SALINE_BAG, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 901, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIALYSATE_TEMPERATURE_HIGH, ALM_ESC_5_MIN, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, + { ALARM_PRIORITY_LOW, 902, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DIALYSATE_TEMPERATURE_LOW, ALM_ESC_5_MIN, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, + { ALARM_PRIORITY_LOW, 903, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_BY_USER, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_LOW, 904, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 905, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY, ALM_ESC_90_MIN, ALARM_ID_PRIME_COMPLETED_MEDIUM }, + { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRIME_PURGE_AIR_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_RTC_BATTERY_LOW, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_RTC_RAM_OPS_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_NO_CARTRIDGE_LOADED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_COMPATIBILITY_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DG_COMPATIBILITY_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_POWER_OUT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_POWER_OUT_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SHASUM, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_CANBUS, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_DISPLAY, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_TOUCH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_SDCARD, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_FAILURE_RTC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_WIFI, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_BLUETOOTH, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_ETHERNET, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_UI_POST_FAILURE_SOUND, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_FLOW_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_DIAL_IN_FLOW_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_ACTIVE_RESERVOIR_WEIGHT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_DRAIN_TIME_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_PRESSURE_READ_TIMEOUT_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_ACID_BOTTLE_LOW_VOLUME, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_HD_TREATMENT_RECIRC_TIMEOUT_WARNING, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, ALARM_ID_HD_TREATMENT_RINSEBACK_TIMEOUT_WARNING, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_TRIMMER_HEATER_ON_WITH_NO_FLOW_TIMEOUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_OR_CONC_CAP_NOT_IN_PROPER_POSITION, 0, ALARM_ID_NO_ALARM }, +}; // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoRcr ClrOnly TxLog ID Escalate In Escalate To /// Table of alarms and their rank. const ALARM_RANK_T ALARM_RANK_TABLE[] = { { 1, ALARM_ID_STUCK_BUTTON_TEST_FAILED }, { 1, ALARM_ID_HD_FPGA_POST_TEST_FAILED }, { 1, ALARM_ID_DG_FPGA_POST_TEST_FAILED }, - { 1, ALARM_ID_WATCHDOG_POST_TEST_FAILED }, + { 1, ALARM_ID_HD_WATCHDOG_POST_TEST_FAILED }, { 1, ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED }, { 1, ALARM_ID_UI_COMM_POST_FAILED }, { 1, ALARM_ID_RTC_CONFIG_ERROR }, @@ -733,12 +777,19 @@ { 1, ALARM_ID_HD_BLOOD_FLOW_INVALID_CAL_RECORD }, { 1, ALARM_ID_HD_DIALYSATE_FLOW_INVALID_CAL_RECORD }, { 1, ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD }, - { 1, ALARM_ID_HD_INVALID_SYSTEM_RECORD }, - { 1, ALARM_ID_HD_INVALID_SERVICE_RECORD }, - { 1, ALARM_ID_DG_INVALID_SYSTEM_RECORD }, - { 1, ALARM_ID_DG_INVALID_SERVICE_RECORD }, { 1, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, { 1, ALARM_ID_DG_SAFETY_SHUTDOWN_POST_TEST_FAILED }, + { 1, ALARM_ID_UI_POST_FAILURE_SHASUM }, + { 1, ALARM_ID_UI_POST_FAILURE_CANBUS }, + { 1, ALARM_ID_UI_POST_FAILURE_DISPLAY }, + { 1, ALARM_ID_UI_POST_FAILURE_TOUCH }, + { 1, ALARM_ID_UI_POST_FAILURE_SDCARD }, + { 1, ALARM_ID_UI_POST_FAILURE_RTC }, + { 1, ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD }, + { 3, ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC }, + { 3, ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC }, + { 3, ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC }, + { 3, ALARM_ID_DG_INVALID_SERVICE_RECORD_CRC }, { 3, ALARM_ID_HD_SOFTWARE_FAULT }, { 3, ALARM_ID_BLOOD_PUMP_MC_CURRENT_CHECK }, { 3, ALARM_ID_BLOOD_PUMP_OFF_CHECK }, @@ -775,10 +826,9 @@ { 3, ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT }, { 3, ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT }, { 3, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT }, - { 3, ALARM_ID_NVDATAMGMT_GROUP_RECORD_CRC_INVALID }, + { 3, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, { 3, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE }, - { 3, ALARM_ID_HD_DIP_OCCLUSION_SELF_TEST_FAILURE }, - { 3, ALARM_ID_HD_DOP_OCCLUSION_SELF_TEST_FAILURE }, + { 3, ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE }, { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_BLOOD_FLOW_STATUS_SELF_TEST_FAILURE }, @@ -794,28 +844,27 @@ { 3, ALARM_ID_HD_SYRINGE_PUMP_DAC_WRITE_ERROR }, { 3, ALARM_ID_HD_SYRINGE_PUMP_RUNNING_WHILE_BP_OFF_ERROR }, { 3, ALARM_ID_HD_VENOUS_PRESSURE_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_VENOUS_PRESSURE_SENSOR_TEMP_OUT_OF_RANGE }, { 3, ALARM_ID_HD_BP_OCCLUSION_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_DPI_OCCLUSON_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_DPO_OCCLUSION_READ_TIMEOUT_ERROR }, + { 3, ALARM_ID_DG_HEATING_INVALID_CAL_RECORD }, + { 3, ALARM_ID_DG_CONC_PUMP_HALL_SENSOR_OUT_OF_RANGE }, { 3, ALARM_ID_HD_BP_OCCLUSION_SENSOR_ERROR }, - { 3, ALARM_ID_HD_DPI_OCCLUSION_SENSOR_ERROR }, - { 3, ALARM_ID_HD_DPO_OCCLUSION_SENSOR_ERROR }, - { 3, ALARM_ID_HD_BP_FLOW_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_BP_FLOW_SENSOR_ERROR }, - { 3, ALARM_ID_HD_DP_FLOW_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_DP_FLOW_SENSOR_ERROR }, - { 3, ALARM_ID_HD_BP_FLOW_SLOW_READ_TIMEOUT_ERROR }, - { 3, ALARM_ID_HD_DP_FLOW_SLOW_READ_TIMEOUT_ERROR }, + { 3, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRFIT_TIMEOUT }, + { 3, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE }, + { 3, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS }, + { 3, ALARM_ID____AVAILABLE_15 }, + { 3, ALARM_ID____AVAILABLE_16 }, + { 3, ALARM_ID____AVAILABLE_17 }, + { 3, ALARM_ID____AVAILABLE_18 }, + { 3, ALARM_ID____AVAILABLE_19 }, { 3, ALARM_ID_HD_BATTERY_COMM_FAULT }, { 3, ALARM_ID_HD_SYRINGE_PUMP_STALL }, { 3, ALARM_ID_HD_NO_CART_SELF_TEST_TIMEOUT }, { 3, ALARM_ID_HD_DRY_SELF_TEST_TIMEOUT }, { 3, ALARM_ID_RTC_COMM_ERROR }, - { 3, ALARM_ID_NVDATA_MFG_RECORD_CRC_ERROR }, + { 3, ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID }, { 3, ALARM_ID_AIR_TRAP_ILLEGAL_LEVELS }, - { 3, ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_CRC_INVALID }, - { 3, ALARM_ID_NVDATAMGMT_INDIVIDUAL_RECORD_TIME_INVALID }, + { 3, ALARM_ID_DG_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID }, + { 3, ALARM_ID____AVAILABLE_20 }, { 3, ALARM_ID_DG_RESTARTED_FAULT }, { 3, ALARM_ID_HD_SYRINGE_PUMP_ADC_ERROR }, { 3, ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR }, @@ -826,25 +875,47 @@ { 3, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 3, ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE }, { 3, ALARM_ID_DG_TEMPERATURE_SENSOR_ADC_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_PRIMARY_HEATER_INTERNAL_TEMP_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_PRIMARY_HEATER_CJ_TEMP_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_TRIMMER_HEATER_INTERNAL_TEMP_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_TRIMMER_HEATER_CJ_TEMP_OUT_OF_RANGE }, + { 3, ALARM_ID____AVAILABLE_28 }, + { 3, ALARM_ID____AVAILABLE_29 }, + { 3, ALARM_ID____AVAILABLE_30 }, + { 3, ALARM_ID____AVAILABLE_31 }, { 3, ALARM_ID_DG_MAIN_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE }, { 3, ALARM_ID_DG_SMALL_PRIMARY_HEATER_VOLTAGE_OUT_OF_RANGE }, { 3, ALARM_ID_DG_TRIMMER_HEATER_VOLTAGE_OUT_OF_RANGE }, { 3, ALARM_ID_HD_UI_COMPATIBILITY_ERROR }, { 3, ALARM_ID_HD_DG_COMPATIBILITY_ERROR }, { 3, ALARM_ID_DG_FPGA_POWER_OUT_TIMEOUT }, { 3, ALARM_ID_HD_FPGA_POWER_OUT_TIMEOUT }, - { 3, ALARM_ID_UI_POST_FAILURE_FILESYSTEM }, - { 3, ALARM_ID_UI_POST_FAILURE_CANBUS }, - { 3, ALARM_ID_UI_POST_FAILURE_DISPLAY }, - { 3, ALARM_ID_UI_POST_FAILURE_TOUCH }, - { 3, ALARM_ID_UI_POST_FAILURE_SDCARD }, - { 3, ALARM_ID_UI_POST_FAILURE_RTC }, - { 3, ALARM_ID_UI_POST_FAILURE_WIFI }, { 3, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_BLOOD_FLOW_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_DIAL_IN_FLOW_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_VENOUS_PRESSURE_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_BP_OCCLUSION_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_ACTIVE_RESERVOIR_WEIGHT_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_DIALYSATE_DRAIN_TIME_OUT }, + { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_READ_TIMEOUT_ERROR }, + { 3, ALARM_ID_DG_LOAD_CELL_WEIGHT_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_LOAD_CELL_PRIMARY_BACKUP_DRIFT_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE }, + { 3, ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE }, + { 3, ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT }, + { 3, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT }, + { 3, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT }, + { 3, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT }, + { 3, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, + { 3, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, + { 3, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT }, + { 3, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT }, + { 3, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY }, + { 3, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY }, + { 3, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, + { 3, ALARM_ID_INLET_WATER_LOW_TEMPERATURE }, + { 3, ALARM_ID_INLET_WATER_LOW_PRESSURE }, + { 3, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, + { 3, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, { 4, ALARM_ID_END_OF_TREATMENT_HIGH }, { 5, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 6, ALARM_ID_HD_BLOOD_LEAK_DETECTED }, @@ -864,33 +935,28 @@ { 19, ALARM_ID_DG_COMM_TIMEOUT }, { 20, ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT }, { 21, ALARM_ID_OCCLUSION_BLOOD_PUMP }, - { 21, ALARM_ID_OCCLUSION_DIAL_IN_PUMP }, - { 21, ALARM_ID_OCCLUSION_DIAL_OUT_PUMP }, + { 21, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_DRIFT_TIMEOUT }, + { 21, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC }, { 22, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 23, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE }, { 24, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT }, - { 26, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, - { 28, ALARM_ID_INLET_WATER_LOW_TEMPERATURE }, - { 30, ALARM_ID_INLET_WATER_HIGH_CONDUCTIVITY }, - { 32, ALARM_ID_INLET_WATER_LOW_CONDUCTIVITY }, - { 34, ALARM_ID_INLET_WATER_LOW_PRESSURE }, { 36, ALARM_ID_PRIME_COMPLETED_HIGH }, { 799, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE }, - { 799, ALARM_ID_NVDATA_SRVC_RECORD_CRC_ERROR }, + { 799, ALARM_ID_HD_SW_CONFIG_RECORD_INVALID_CRC }, { 799, ALARM_ID_NVDATA_HW_USAGE_DATA_CRC_ERROR }, - { 799, ALARM_ID_NVDATA_CAL_RECORD_CRC_ERROR }, - { 799, ALARM_ID_BLOOD_PUMP_FLOW_VS_MOTOR_SPEED_CHECK }, + { 799, ALARM_ID____AVAILABLE_24 }, { 799, ALARM_ID_DIAL_IN_PUMP_FLOW_VS_MOTOR_SPEED_CHECK }, { 799, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH }, - { 799, ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW }, - { 799, ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW }, + { 799, ALARM_ID____AVAILABLE_26 }, + { 799, ALARM_ID____AVAILABLE_27 }, { 799, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM }, { 799, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM }, { 799, ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM }, { 799, ALARM_ID_TREATMENT_RECIRC_TIMEOUT_ALARM }, + { 799, ALARM_ID_PUMP_TRACK_LATCH_OPENED }, { 799, ALARM_ID_CARTRIDGE_DOOR_OPENED }, - { 799, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_HIGH }, - { 799, ALARM_ID_DIALYSATE_TEMPERATURE_TOO_LOW }, + { 799, ALARM_ID_HD_ACTIVE_RESERVOIR_DEPLETION_TIME_OUT }, + { 799, ALARM_ID_DIALYSATE_FLOW_RATE_OUT_OF_RANGE }, { 799, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, { 799, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION }, { 799, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, @@ -904,9 +970,7 @@ { 799, ALARM_ID_DG_LOAD_CELL_ADC_ERROR }, { 799, ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE }, { 799, ALARM_ID_DG_LOAD_CELLS_INVALID_CALIBRATION }, - { 799, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, { 799, ALARM_ID_UV_REACTOR_NOT_HEALTHY }, - { 799, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, { 799, ALARM_ID_DG_CONCENTRATE_PUMP_FAULT }, { 799, ALARM_ID_CP1_SPEED_CONTROL_ERROR }, { 799, ALARM_ID_CP2_SPEED_CONTROL_ERROR }, @@ -915,24 +979,22 @@ { 799, ALARM_ID_FLOW_RATE_OUT_OF_UPPER_RANGE }, { 799, ALARM_ID_FLOW_RATE_OUT_OF_LOWER_RANGE }, { 799, ALARM_ID_RO_PUMP_FLOW_RATE_OUT_OF_RANGE }, - { 799, ALARM_ID_RO_PUMP_OFF_FAULT }, { 799, ALARM_ID_RO_PUMP_PRESSURE_OUT_OF_RANGE }, { 799, ALARM_ID_DG_TEMPERATURE_SENSOR_FAULT }, { 799, ALARM_ID_DG_TEMPERATURE_SENSORS_ADC_FAULT }, { 799, ALARM_ID_DG_HEATERS_NEGATIVE_COLD_JUNCTION_TEMPERATURE }, { 799, ALARM_ID_DG_HEATERS_FAULT }, - { 799, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE }, { 799, ALARM_ID_DG_BAD_INLET_WATER_QUALITY }, { 799, ALARM_ID_INLET_WATER_PRESSURE_FAULT }, { 799, ALARM_ID_PRESSURE_SENSOR_FAULT }, - { 799, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, { 799, ALARM_ID_CONDUCTIVITY_SENSOR_FAULT }, - { 799, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, { 799, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE }, - { 799, ALARM_ID_DG_HEATERS_ON_WITH_NO_FLOW_TIMEOUT }, + { 799, ALARM_ID_DG_PRIMARY_HEATER_ON_WITH_NO_FLOW_TIMEOUT }, { 799, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT }, { 799, ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED }, - { 799, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, + { 799, ALARM_ID_DG_TRIMMER_HEATER_ON_WITH_NO_FLOW_TIMEOUT }, + { 799, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED }, + { 799, ALARM_ID_DG_DIALYSATE_OR_CONC_CAP_NOT_IN_PROPER_POSITION }, { 800, ALARM_ID_BLOOD_SITTING_WARNING }, { 801, ALARM_ID_END_OF_TREATMENT_ALARM }, { 802, ALARM_ID_PRIME_COMPLETED_MEDIUM }, @@ -941,8 +1003,9 @@ { 899, ALARM_ID_END_TREATMENT_TIMEOUT_ALARM }, { 899, ALARM_ID_BLOOD_PRIME_VOLUME_CHECK_FAILURE }, { 899, ALARM_ID_HD_SYRINGE_DETECTED }, - { 899, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED }, { 899, ALARM_ID_HD_BATTERY_PACK_CHARGE_TOO_LOW }, + { 899, ALARM_ID_HD_TREATMENT_RECIRC_TIMEOUT_WARNING }, + { 899, ALARM_ID_HD_TREATMENT_RINSEBACK_TIMEOUT_WARNING }, { 900, ALARM_ID_EMPTY_SALINE_BAG }, { 901, ALARM_ID_DIALYSATE_TEMPERATURE_HIGH }, { 902, ALARM_ID_DIALYSATE_TEMPERATURE_LOW }, @@ -955,27 +1018,25 @@ { 909, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT }, { 910, ALARM_ID_PRE_TREATMENT_DRY_SELF_TEST_FAILURE }, { 910, ALARM_ID_PRE_TREATMENT_WET_SELF_TEST_FAILURE }, + { 999, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, + { 999, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, { 999, ALARM_ID_RTC_BATTERY_LOW }, { 999, ALARM_ID_RTC_RAM_OPS_ERROR }, { 999, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, { 999, ALARM_ID_INSTALL_NEW_CARTRIDGE }, - { 999, ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY }, + { 999, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT }, { 999, ALARM_ID_NO_CARTRIDGE_LOADED }, { 999, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, { 999, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, - { 999, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT }, - { 999, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT }, - { 999, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT }, - { 999, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE }, { 999, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT }, { 999, ALARM_ID_DG_HEAT_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT }, { 999, ALARM_ID_DG_HEAT_DISINFECT_INLET_COND_AND_TEMP_OUT }, - { 999, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT }, - { 999, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT }, - { 999, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT }, + { 999, ALARM_ID_UI_POST_FAILURE_WIFI }, { 999, ALARM_ID_UI_POST_FAILURE_BLUETOOTH }, { 999, ALARM_ID_UI_POST_FAILURE_ETHERNET }, { 999, ALARM_ID_UI_POST_FAILURE_SOUND }, + { 999, ALARM_ID_DG_ACID_BOTTLE_LOW_VOLUME }, + { 999, ALARM_ID_DG_BICARB_BOTTLE_LOW_VOLUME }, { 999, ALARM_ID_NO_ALARM }, };