Index: AlarmDefs.h =================================================================== diff -u -re887d8a4f81f546eef9ba436814c39bfde995ffc -r10f3e3d426cd8fd4fc9f8e90a4bf318e672b27e3 --- AlarmDefs.h (.../AlarmDefs.h) (revision e887d8a4f81f546eef9ba436814c39bfde995ffc) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 10f3e3d426cd8fd4fc9f8e90a4bf318e672b27e3) @@ -189,7 +189,7 @@ ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE = 151, ///< Inlet water conductivity in low range ALARM_ID_INLET_WATER_PRESSURE_IN_LOW_RANGE = 152, ///< Inlet water pressure in low range ALARM_ID_PRIME_COMPLETED_HIGH = 153, ///< HD prime completed high priority alarm - ALARM_ID_NVDATA_EEPROM_OPS_FAILURE = 154, ///< EEPROM operations (read, write, erase) failure + ALARM_ID_AVAILABLE_1 = 154, ///< Alarm ID available for use ALARM_ID_HD_NEW_RESERVOIRS_DATA_MESSAGE_NOT_RECEIVE = 155, ///< HD No reservoirs data message receive at least once every 2 seconds ALARM_ID_HD_NEW_DG_OPERATION_MODE_MESSAGE_NOT_RECEIVE = 156, ///< HD No DG operation mode message receive at least once every 2 seconds ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT = 157, ///< DG chemical disinfect prime acid line timeout. @@ -269,7 +269,7 @@ ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE = 231, ///< HD pre-treatment mode dry pressure self-test failure ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE = 232, ///< HD pre-treatment mode wet self-test LC vs. LC failure ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC = 233, ///< DG barometric sensor coefficients bad CRC - ALARM_ID_RTC_RAM_OPS_ERROR = 234, ///< RTC (i.e read time) or RAM operations failure (read or write) + ALARM_ID_AVIALBLE_2 = 234, ///< Alarm ID availble for use ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK = 235, ///< HD in treatment stopped sub-mode after rinseback completed (no escalation) ALARM_ID_INSTALL_NEW_CARTRIDGE = 236, ///< HD needs new cartridge to be installed ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT = 237, ///< HD prime saline dialyzer time out alarm @@ -627,7 +627,7 @@ { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_MEDIUM, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_PRESSURE_IN_LOW_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 36, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_COMPLETED_HIGH, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_1, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NEW_RESERVOIRS_DATA_MESSAGE_NOT_RECEIVE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NEW_DG_OPERATION_MODE_MESSAGE_NOT_RECEIVE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT, 0, ALARM_ID_NO_ALARM }, @@ -710,7 +710,7 @@ { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_RTC_RAM_OPS_ERROR, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVIALBLE_2, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, @@ -1038,7 +1038,7 @@ { 21, ALARM_ID_OCCLUSION_BLOOD_PUMP }, { 36, ALARM_ID_PRIME_COMPLETED_HIGH }, { 799, ALARM_ID_HD_VENOUS_LINE_OCCLUSION }, - { 799, ALARM_ID_NVDATA_EEPROM_OPS_FAILURE }, + { 799, ALARM_ID_AVAILABLE_1 }, { 799, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_1_ALARM }, { 799, ALARM_ID_HD_LOAD_CELL_ACCELERATION_RES_2_ALARM }, { 799, ALARM_ID_TREATMENT_RINSEBACK_TIMEOUT_ALARM }, @@ -1092,7 +1092,7 @@ { 910, ALARM_ID_PRE_TREATMENT_WET_PRIME_TEST_FAILURE }, { 999, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, { 999, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, - { 999, ALARM_ID_RTC_RAM_OPS_ERROR }, + { 999, ALARM_ID_AVIALBLE_2 }, { 999, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, { 999, ALARM_ID_INSTALL_NEW_CARTRIDGE }, { 999, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT }, @@ -1283,7 +1283,7 @@ { 151 , ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_LOW_RANGE , "DG | Inlet Water Conductivity Low | Inlet water conductivity is low.\n- Check the incoming water for issues. | Inlet water conductivity too low | Inlet water conductivity < 100 uS/cm. | "}, { 152 , ALARM_ID_INLET_WATER_PRESSURE_IN_LOW_RANGE , "DG | Inlet Water Pressure Low | Inlet water pressure is low.\n- Check the incoming water supply. | Inlet water pressure too low | Inlet water pressure < 25 PSI. | "}, { 153 , ALARM_ID_PRIME_COMPLETED_HIGH , "HD | Prime Complete | Prime of the bloodlines is complete. | HD prime completed high priority alarm | If alarm 213 is not cleared by user within 30 minutes. | "}, - { 154 , ALARM_ID_NVDATA_EEPROM_OPS_FAILURE , "HD/DG | Non-volatile Data Error | Call service to schedule a repair. | EEPROM operations (read write erase) failure write erase) failure | If the RTC RAM or the EEPROMcommunication has timeout. | "}, + { 154 , ALARM_ID_AVAILABLE_1 , "N/A | N/A | N/A | N/A | N/A | "}, { 155 , ALARM_ID_HD_NEW_RESERVOIRS_DATA_MESSAGE_NOT_RECEIVE , "HD | No reservoir data received | Call service to schedule a repair. | HD No reservoir data message receive at least once every 2 seconds | No new reservoir data for 2 seconds. | "}, { 156 , ALARM_ID_HD_NEW_DG_OPERATION_MODE_MESSAGE_NOT_RECEIVE , "HD | No DG op mode received | Call service to schedule a repair. | HD No DG op mode message receive at least once every 2 seconds | No DG op mode for 2 seconds. | "}, { 157 , ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT , "DG | Chemical Disinfection Error | Ensure the acid is connected to the bicarb line | Chemical disinfect priming the acid line timeout | If the disinfectant acid line is not primed within a certain period of time. | "}, @@ -1363,7 +1363,7 @@ { 231 , ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE , "HD | Self Test Error | Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. | HD pre-treatment mode dry self-tests failure | If the following dry self tests have failed: 1. handleDrySelfTestPressureSensorsState 2. handleDrySelfTestPressureSensorsNormalState | "}, { 232 , ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE , "HD | Self Test Error | Self Test Failure. Please ensure the disposable cartridge is completely installed and the handle moved to the down position. Check for closed clamps or kinks in the tubing. | HD pre-treatment mode wet self-tests failure | If the following wet self tests have failed: 1. handleWetSelfTestPrimeCheckState 2. handleWetSelfTestFirstDisplacementVerifyState 3. handleWetSelfTestSecondDisplacementVerifyState | "}, { 233 , ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC , "DG | Pressure Sensors Error | Call service to schedule a repair. | DG barometric pressure sensor bad coefficients CRC | If the following happens: 1. The stored CRC in the sensor does not match the calculated CRC. 2. The CRC and coefficients have not been received from the sensor after 20 seconds from the power up. | "}, - { 234 , ALARM_ID_RTC_RAM_OPS_ERROR , "HD/DG | Communication Failure | Communication failure.\n- Ensure all cords are securely connected. | RTC (i.e read time) or RAM operations failure (read or write) | If the status of the RTC write to register is NOT successful. | "}, + { 234 , ALARM_ID_AVIALBLE_2 , "N/A | N/A | N/A | N/A | N/A | "}, { 235 , ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK , "HD | Rinseback Complete | Rinseback has been completed. | HD in treatment stopped sub-mode after rinseback completed (no escalation) | If there is no active alarm and rinseback has completed. | "}, { 236 , ALARM_ID_INSTALL_NEW_CARTRIDGE , "HD | New Cartridge Needed | New cartridge needs to be installed. | HD needs new cartridge to be installed | If the air trap sensor reported AIR and bubble sensor detected bubbles. | "}, { 237 , ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Prime Error | Call service to schedule a repair. | HD prime saline dialyzer time out alarm | This alarm is available. If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "},