Index: AlarmDefs.h =================================================================== diff -u -rf2fc7cdd53e592f34a41e177e5a1b3fd009f99b9 -rcb4e5be0ef260f2ceb1a97de18cce2bfb3830090 --- AlarmDefs.h (.../AlarmDefs.h) (revision f2fc7cdd53e592f34a41e177e5a1b3fd009f99b9) +++ AlarmDefs.h (.../AlarmDefs.h) (revision cb4e5be0ef260f2ceb1a97de18cce2bfb3830090) @@ -272,7 +272,7 @@ ALARM_ID_DG_INLET_WATER_PRESSURE_IN_HIGH_RANGE = 234, ///< DG inlet water pressure in high range. ALARM_ID_HD_TREATMENT_STOPPED_AFTER_RINSEBACK = 235, ///< HD in treatment stopped sub-mode after rinseback completed (no escalation) ALARM_ID_HD_INSTALL_NEW_CARTRIDGE = 236, ///< HD needs new cartridge to be installed - ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT = 237, ///< HD prime saline dialyzer time out alarm + ALARM_ID_AVAILABLE_13 = 237, ///< Available for useALARM_ID_AVAILABLE_13 ALARM_ID_HD_NO_CARTRIDGE_LOADED = 238, ///< HD no cartridge loaded or installed improperly alarm ALARM_ID_HD_CARTRIDGE_REMOVAL_FAILURE = 239, ///< HD fail to remove cartridge alarm ALARM_ID_DG_BICARB_CONDUCTIVITY_OUT_OF_RANGE = 240, ///< DG bicarb conductivity out of range during bicarb pump check alarm @@ -721,7 +721,7 @@ { ALARM_PRIORITY_MEDIUM, 430, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_HIGH_RANGE }, { ALARM_PRIORITY_LOW, 738, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_HD_TREATMENT_STOPPED_AFTER_RINSEBACK }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_INSTALL_NEW_CARTRIDGE }, - { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT }, + { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_13 }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_NO_CARTRIDGE_LOADED }, { ALARM_PRIORITY_LOW, 746, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_CARTRIDGE_REMOVAL_FAILURE }, { ALARM_PRIORITY_MEDIUM, 411, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , ALARM_ID_DG_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, @@ -1087,7 +1087,6 @@ { 720, ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT }, { 720, ALARM_ID_HD_PRIME_DIALYSATE_DIALYZER_TIME_OUT }, { 720, ALARM_ID_HD_PRIME_DIALYSATE_BYPASS_TIME_OUT }, - { 720, ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT }, { 725, ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED }, { 725, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 725, ALARM_ID_HD_PRE_TREATMENT_WET_PRIME_TEST_FAILURE }, @@ -1130,6 +1129,7 @@ { 999, ALARM_ID_AVAILABLE_10 }, { 999, ALARM_ID_AVAILABLE_11 }, { 999, ALARM_ID_AVAILABLE_12 }, + { 999, ALARM_ID_AVAILABLE_13 }, { 999, ALARM_ID_AVAILABLE_15 }, { 999, ALARM_ID_AVAILABLE_16 }, { 999, ALARM_ID_AVAILABLE_17 }, @@ -1395,7 +1395,7 @@ { 234 , ALARM_ID_DG_INLET_WATER_PRESSURE_IN_HIGH_RANGE , "DG | Incoming Water Pressure High | Incoming water pressure is high.\n- Treatment is currently paused.\n- Check the incoming water supply.\n- When the pressure is within target range\nRESUME button will be available.\n- Press RESUME to continue treatment.\n\nDial. Gen: Inlet Water Pres High | DG inlet water pressure is too high | If the inlet water pressure is > 80 psig. | "}, { 235 , ALARM_ID_HD_TREATMENT_STOPPED_AFTER_RINSEBACK , "HD | Rinseback Complete | Rinseback is complete. \n- Follow facililty policy prior to disconnecting patient. \n- Press OK to continue. \n\nProcess: Rinseback Complete | HD in treatment stopped sub-mode after rinseback completed (no escalation) | If there is no active alarm and rinseback has completed. | "}, { 236 , ALARM_ID_HD_INSTALL_NEW_CARTRIDGE , "HD | Self Test: Fluid Present | A problem has been detected during self- test. \n- Cartridges are single- use only and fluid is present.\n- Install new cartridge to resume.\n\nProcess: Pre- Tx Dry Self- Test | HD needs new cartridge to be installed | If the air trap sensor reported AIR and bubble sensor detected bubbles. | "}, - { 237 , ALARM_ID_HD_PRIME_SALINE_DIALYZER_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n - Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre- Tx Prime Timeout | HD prime saline dialyzer time out alarm | If timeout, just transition to HD_PRIME_RESERVOIR_TWO_FILL_COMPLETE_STATE | "}, + { 237 , ALARM_ID_AVAILABLE_13 , " | | \n\n | | | "}, { 238 , ALARM_ID_HD_NO_CARTRIDGE_LOADED , "HD | Cartridge Not Dectected | A problem has been detected during self- test. \n- Cartridge is not detected.\n- Confirm cartridge is properly installed.\n\nProcess: Pre- Tx Dry Self- Test | HD no cartridge loaded or installed improperly alarm | If the measured blood pump occlucsion pressure reading is < 5000 or > 24500. | "}, { 239 , ALARM_ID_HD_CARTRIDGE_REMOVAL_FAILURE , "HD | Cartridge Still Detected | A problem has been detected during self- test. \n- Cartridge is still present or was unloaded incorrectly.\n- Confirm the cartridge has been fully removed.\n\nProcess: Post- Tx Remove Cartridge | HD fail to remove cartridge alarm | In the post treatment state, if the cartridge has not been removed. | "}, { 240 , ALARM_ID_DG_BICARB_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Error During Prime | Conductivity out of range during prime.\n- Confirm that acid and bicarbonate concentrates\nare securely connected.\n- If empty, replace. \n- Treatment will need to be resumed when conductivity\nis within target range.\n\nDial. Gen: Bicarb Conc. Cond. | Bicarb conductivity out of range during bicarb pump check alarm | If the conductivity value for bicarbonate concentrate is out of range for more than 45 secs. | "},