Index: AlarmDefs.h =================================================================== diff -u -rffd00bc27196c79dcc640c5b0bc5ee9fe733bb88 -r2237afbec4f596661d3a2059c383955199a034e5 --- AlarmDefs.h (.../AlarmDefs.h) (revision ffd00bc27196c79dcc640c5b0bc5ee9fe733bb88) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 2237afbec4f596661d3a2059c383955199a034e5) @@ -293,7 +293,7 @@ ALARM_ID_HD_UI_COMPATIBILITY_ERROR = 255, ///< HD and UI software builds are not compatible ALARM_ID_HD_DISINFECT_CHEM_FLUSH = 256, ///< HD processor is in Disinfect Chemical Flush mode ALARM_ID_AVAILABLE_8 = 257, ///< Alarm ID available for use - ALARM_ID_AVAILABLE_9 = 258, ///< Alarm Id available + ALARM_ID_HD_UI_POST_FAILURE_OS_VERSION = 258, ///< HD UI POST OS version compatibility failure ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE = 259, ///< HD temperatures out of range ALARM_ID_HD_UI_POST_FAILURE_SHASUM = 260, ///< HD UI POST Application Integrity (Sha256Sum) failure ALARM_ID_HD_UI_POST_FAILURE_CANBUS = 261, ///< HD UI POST CANBus failure @@ -746,7 +746,7 @@ { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_COMPATIBILITY_ERROR }, { ALARM_PRIORITY_LOW, 843, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_DISINFECT_CHEM_FLUSH }, { ALARM_PRIORITY_LOW, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_8 }, - { ALARM_PRIORITY_LOW, 999, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_9 }, + { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_OS_VERSION }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_SHASUM }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_CANBUS }, @@ -833,6 +833,7 @@ { 1, ALARM_ID_HD_ACCELEROMETERS_INVALID_CAL_RECORD }, { 1, ALARM_ID_HD_HEPARIN_FORCE_SENSOR_INVALID_CAL_RECORD }, { 1, ALARM_ID_HD_SAFETY_SHUTDOWN_POST_TEST_FAILED }, + { 1, ALARM_ID_HD_UI_POST_FAILURE_OS_VERSION }, { 1, ALARM_ID_HD_UI_POST_FAILURE_SHASUM }, { 1, ALARM_ID_HD_UI_POST_FAILURE_CANBUS }, { 1, ALARM_ID_HD_UI_POST_FAILURE_TOUCH }, @@ -1422,9 +1423,9 @@ { 255 , ALARM_ID_HD_UI_COMPATIBILITY_ERROR , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI Compatibility | HD and UI software builds are not compatible | If the compatibility revision field of the UI is not equal to SW_COMPATIBILITY_REV. | "}, { 256 , ALARM_ID_HD_DISINFECT_CHEM_FLUSH , "HD | Chemical Flush in Progress | Chemical flush in progress.\n- Please wait for the process to complete. \n- You will not be able to create a treatment until the process\nis finished.\n- To end this process, press STOP on the front of the device. | Cleaning: Chem Flush In Progress | DG flush started | If DG flush successfully started from the UI. | "}, { 257 , ALARM_ID_AVAILABLE_8 , " | | | | | | "}, - { 258 , ALARM_ID_AVAILABLE_9 , " | | | | | | "}, - { 259 , ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD Fault: Temp Sensors Error | HD temperatures out of range | If thermistor reports temperature > 80.0 C or < 0.0 C for a certain period of time. | "}, - { 260 , ALARM_ID_HD_UI_POST_FAILURE_SHASUM , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI Image | UI POST Application Integrity (Sha256Sum) failure | If the UI POST reports a shasum faillure. | "}, + { 258 , ALARM_ID_HD_UI_POST_FAILURE_OS_VERSION , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: OS Version | UI POST OS Version compatibility failure | If the UI POST reports the OS Version compatibility failure. | "}, + { 259 , ALARM_ID_HD_TEMPERATURES_OUT_OF_RANGE , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD Fault: Temp Sensors Error | HD temperatures out of range | If thermistor reports temperature > 80.0 C or < 0.0 C for a certain period of time. | "}, + { 260 , ALARM_ID_HD_UI_POST_FAILURE_SHASUM , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI Image | UI POST Application Integrity (Sha256Sum) failure | If the UI POST reports a shasum failure. | "}, { 261 , ALARM_ID_HD_UI_POST_FAILURE_CANBUS , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI CAN Driver | UI POST CANBus failure | If the UI POST reports a can bus failure. | "}, { 262 , ALARM_ID_HD_UI_POST_FAILURE_DISPLAY , " | | | | UI POST Display failure | If the UI POST reports a display failure. | "}, { 263 , ALARM_ID_HD_UI_POST_FAILURE_TOUCH , "UI HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI Touch Driver | UI POST Touch failure | If the UI POST reports a touch failure. | "},