Index: AlarmDefs.h =================================================================== diff -u -rffd00bc27196c79dcc640c5b0bc5ee9fe733bb88 -rb3a68f34b3ea0089a7b1d6bfb130badac90a176a --- AlarmDefs.h (.../AlarmDefs.h) (revision ffd00bc27196c79dcc640c5b0bc5ee9fe733bb88) +++ AlarmDefs.h (.../AlarmDefs.h) (revision b3a68f34b3ea0089a7b1d6bfb130badac90a176a) @@ -543,7 +543,7 @@ { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_NOT_FUNCTIONAL }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_CURRENT_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_VALVE_POSITION_OUT_OF_RANGE }, - { ALARM_PRIORITY_LOW, 716, FALSE, FALSE, TRUE , TRUE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_PRIME_TIMEOUT }, + { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_PRIME_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BARO_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_DG_COMMAND_INVALID_PARAMETER_FAULT }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, @@ -911,6 +911,7 @@ { 10, ALARM_ID_HD_SYRINGE_PUMP_ENCODER_DIRECTION_ERROR }, { 10, ALARM_ID_HD_SYRINGE_PUMP_CONTROLLER_DIRECTION_ERROR }, { 10, ALARM_ID_HD_SYRINGE_PUMP_STALL }, + { 10, ALARM_ID_HD_SYRINGE_PUMP_PRIME_TIMEOUT }, { 10, ALARM_ID_HD_AIR_TRAP_ILLEGAL_LEVELS }, { 10, ALARM_ID_HD_SYRINGE_PUMP_FPGA_ADC_FAULT }, { 10, ALARM_ID_HD_SYRINGE_PUMP_VOLUME_ERROR }, @@ -1093,7 +1094,6 @@ { 710, ALARM_ID_HD_NO_CARTRIDGE_LOADED }, { 715, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { 716, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION }, - { 716, ALARM_ID_HD_SYRINGE_PUMP_PRIME_TIMEOUT }, { 720, ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT }, { 720, ALARM_ID_HD_PRIME_DIALYSATE_DIALYZER_TIME_OUT }, { 720, ALARM_ID_HD_PRIME_DIALYSATE_BYPASS_TIME_OUT },