Index: MsgDefs.h =================================================================== diff -u -r67b0a5bedb7b1d1268845668a202a7ff0a5cf253 -red438a9468bc8d977dd6c02403438010d39c23f8 --- MsgDefs.h (.../MsgDefs.h) (revision 67b0a5bedb7b1d1268845668a202a7ff0a5cf253) +++ MsgDefs.h (.../MsgDefs.h) (revision ed438a9468bc8d977dd6c02403438010d39c23f8) @@ -9,7 +9,7 @@ * @file MsgDefs.h * * @author (last) Dara Navaei -* @date (last) 26-Apr-2023 +* @date (last) 15-May-2023 * * @author (original) Sean * @date (original) 27-Feb-2020 @@ -230,6 +230,8 @@ MSG_ID_DG_START_STOP_HEAT_DISINFECT_ACTIVE_COOL = 0xC6, ///< DG heat disinfect active cool start/stop command MSG_ID_HD_AIR_PUMP_DATA = 0xC7, ///< HD air pump data publish MSG_ID_HD_SEND_CHEM_FLUSH_SAMPLE_PASS_FAIL_TO_DG = 0xC8, ///< HD send chemical disinfect flush sample pass/fail to DG + MSG_ID_DG_START_STOP_RO_PERMEATE_SAMPLE_MODE_CMD_REQUEST = 0xC9, ///< DG start/stop RO permeate sample mode command request + MSG_ID_DG_RO_PERMEATE_SAMPLE_DATA = 0xCA, ///< DG RO permeate sample mode data broadcast #ifdef EMC_TEST_BUILD MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing @@ -383,6 +385,12 @@ MSG_ID_HD_DIAL_OUT_PUMP_HARD_STOP = 0x8090, ///< HD dialysate outlet pump hard stop command MSG_ID_HD_BLOOD_PUMP_HARD_STOP = 0x8091, ///< HD blood pump hard stop command MSG_ID_HD_DIALIN_CHECK_IN = 0x8092, ///< HD dialin check in + MSG_ID_HD_ENABLE_VENOUS_BUBBLE_ALARM_DETECTION = 0x8093, ///< HD enable venous bubble alarm detection + MSG_ID_HD_GET_TEST_CONFIGURATION = 0x8094, ///< HD get test configuration + MSG_ID_HD_SEND_TEST_CONFIGURATION = 0x8095, ///< HD send test configuration + MSG_ID_HD_RESET_ALL_TEST_CONFIGURATIONS = 0x8096, ///< HD reset all the configurations + MSG_ID_HD_SET_TEST_CONFIGURATION = 0x8097, ///< HD set test configuration + MSG_ID_HD_SIGNAL_RECOVER_FROM_FAULT_MODE = 0x8098, ///< HD signal recover from fault mode MSG_ID_FIRST_DG_TESTER_MESSAGE = 0xA000, ///< First DG test message ID MSG_ID_DG_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DG_TESTER_MESSAGE, ///< DG tester log-in @@ -490,6 +498,11 @@ MSG_ID_DG_SEND_TEST_CONFIGURATION = 0xA068, ///< DG send test configuration MSG_ID_DG_RESET_ALL_TEST_CONFIGURATIONS = 0xA069, ///< DG reset all the configurations MSG_ID_DG_DIALIN_CHECK_IN = 0xA06A, ///< DG Dialin check in + MSG_ID_DG_GET_LOAD_CELLS_TARE_VALUES = 0xA06B, ///< DG get load cells tare values + MSG_ID_DG_SET_LOAD_CELLS_TARE_VALUES = 0xA06C, ///< DG set load cells tare values + MSG_ID_DG_SEND_LOAD_CELLS_TARE_VALUES = 0xA06D, ///< DG send load cells tare values to dialin + MSG_ID_DG_SET_COND_SENSOR_CAL_TABLE = 0xA06E, ///< DG set conductivity sensor's calibration table + MSG_ID_DG_SIGNAL_RECOVER_FROM_FAULT_MODE = 0xA06F, ///< DG signal recover from fault mode MSG_ID_HD_DEBUG_EVENT = 0xFFF1, ///< HD debug event text to be logged in event log MSG_ID_DG_DEBUG_EVENT = 0xFFF2, ///< DG debug event text to be logged in event log @@ -522,8 +535,8 @@ REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS = 16, ///< A saline bolus is in progress REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE = 17, ///< A treatment parameter is out of range REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION = 18, ///< The Heparin pre-stop setting is greater than the treatment duration - REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH = 19, ///< Arterial pressure low and high alarm limits are not inconsistent - REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH = 20, ///< Venous pressure low and high alarm limits are inconsistent + REQUEST_REJECT_REASON_AVAILABLE_1 = 19, ///< Not used + REQUEST_REJECT_REASON_AVAILABLE_2 = 20, ///< Not used REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED = 21, ///< Saline bolus volume maximum has been reached - no more saline allowed REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS = 22, ///< A saline bolus is not in progress REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE = 23, ///< Requested user action is disabled in current state