Index: MsgDefs.h =================================================================== diff -u -r68000d9b13c63cf0f59d4de9f5e9888da5920fa1 -r53ba6201c60349c644bec937cd446992447c4bf7 --- MsgDefs.h (.../MsgDefs.h) (revision 68000d9b13c63cf0f59d4de9f5e9888da5920fa1) +++ MsgDefs.h (.../MsgDefs.h) (revision 53ba6201c60349c644bec937cd446992447c4bf7) @@ -1,44 +1,53 @@ /************************************************************************** * +<<<<<<< HEAD * Copyright (c) 2019-2021 Diality Inc. - All Rights Reserved. +======= +* Copyright (c) 2020-2022 Diality Inc. - All Rights Reserved. +>>>>>>> staging * * THIS CODE MAY NOT BE COPIED OR REPRODUCED IN ANY FORM, IN PART OR IN * WHOLE, WITHOUT THE EXPLICIT PERMISSION OF THE COPYRIGHT OWNER. * -* @file MsgDefs.h +* @file MsgDefs.h * +<<<<<<< HEAD * @author (last) Dara Navaei * @date (last) 30-Apr-2021 +======= +* @author (last) Dara Navaei +* @date (last) 23-May-2022 +>>>>>>> staging * -* @author (original) Sean -* @date (original) 27-Feb-2020 +* @author (original) Sean +* @date (original) 27-Feb-2020 * ***************************************************************************/ - -#ifndef __MESSAGE_DEFINITIONS_H__ -#define __MESSAGE_DEFINITIONS_H__ - + +#ifndef __MESSAGE_DEFINITIONS_H__ +#define __MESSAGE_DEFINITIONS_H__ + // ********** public definitions ********** /** * @addtogroup SystemCommMessages * @{ - */ - + */ + /// Enumeration of system message IDs -enum Msg_IDs -{ // normal CAN messages - MSG_ID_UNUSED = 0, ///< Zero is an undefined (un-used) message ID) - MSG_ID_OFF_BUTTON_PRESS = 1, ///< HD/UI off button interactions - MSG_ID_ALARM_STATUS = 2, ///< HD broadcast of system alarm state information - MSG_ID_ALARM_TRIGGERED = 3, ///< Alarm triggered event - MSG_ID_ALARM_CLEARED = 4, ///< Alarm cleared event - MSG_ID_BLOOD_FLOW_DATA = 5, ///< HD broadcast of blood flow/pump data - MSG_ID_DG_CHECK_IN = 6, ///< DG check-in with HD - MSG_ID_UI_CHECK_IN = 7, ///< UI check-in with HD - MSG_ID_DIALYSATE_FLOW_DATA = 8, ///< HD broadcast of dialysate inlet flow/pump data - MSG_ID_PRESSURE_OCCLUSION_DATA = 9, ///< HD broadcast of pressure/occlusion data +enum Msg_IDs +{ // normal CAN messages + MSG_ID_UNUSED = 0x0, ///< Zero is an undefined (un-used) message ID) + MSG_ID_OFF_BUTTON_PRESS = 0x1, ///< HD/UI off button interactions + MSG_ID_ALARM_STATUS = 0x2, ///< HD broadcast of system alarm state information + MSG_ID_ALARM_TRIGGERED = 0x3, ///< Alarm triggered event + MSG_ID_ALARM_CLEARED = 0x4, ///< Alarm cleared event + MSG_ID_BLOOD_FLOW_DATA = 0x5, ///< HD broadcast of blood flow/pump data + MSG_ID_DG_CHECK_IN = 0x6, ///< DG check-in with HD + MSG_ID_UI_CHECK_IN = 0x7, ///< UI check-in with HD + MSG_ID_DIALYSATE_FLOW_DATA = 0x8, ///< HD broadcast of dialysate inlet flow/pump data + MSG_ID_PRESSURE_OCCLUSION_DATA = 0x9, ///< HD broadcast of pressure/occlusion data MSG_ID_RTC_EPOCH = 0xA, ///< HD broadcast of current date and time from clock MSG_ID_DIALYSATE_OUT_FLOW_DATA = 0xB, ///< HD broadcast of dialysate outlet flow/pump/load cell data MSG_ID_LOAD_CELL_READINGS = 0xC, ///< DG broadcast of load cell weights @@ -55,7 +64,7 @@ MSG_ID_USER_BLOOD_DIAL_RATE_CHANGE_REQUEST = 0x17, ///< User request to change blood and dialysate rates MSG_ID_USER_BLOOD_DIAL_RATE_CHANGE_RESPONSE = 0x18, ///< HD response to user request to change blood and dialysate rates MSG_ID_SET_DG_DIALYSATE_TEMP_TARGETS = 0x19, ///< HD provides DG with dialysate temperature set points - MSG_ID_TREATMENT_PARAM_CHANGE_RANGES = 0x1A, ///< HD provides several parameter change ranges as they evolve over treatment duration + MSG_ID_TREATMENT_PARAM_CHANGE_RANGES = 0x1A, ///< HD provides several parameter change ranges as they evolve over treatment duration MSG_ID_USER_TREATMENT_TIME_CHANGE_RESPONSE = 0x1B, ///< HD response to user request to change treatment duration MSG_ID_REQUEST_FW_VERSIONS = 0x1C, ///< UI request for f/w versions MSG_ID_HD_VERSION = 0x1D, ///< HD f/w version @@ -69,20 +78,20 @@ MSG_ID_HD_OP_MODE = 0x25, ///< HD broadcast current operating mode MSG_ID_STARTING_STOPPING_TREATMENT_CMD = 0x26, ///< HD request to DG to move in/out of standby mode due to treatment start/stop MSG_ID_DG_OP_MODE = 0x27, ///< DG broadcast current operating mode - MSG_ID_DG_RESERVOIR_DATA = 0x28, ///< DG broadcast reservoir data + MSG_ID_DG_RESERVOIRS_DATA = 0x28, ///< DG broadcast reservoirs data MSG_ID_DG_SAMPLE_WATER_CMD = 0x29, ///< HD request to DG to allow user to get a water sample MSG_ID_DG_VALVES_STATES = 0x2A, ///< DG broadcast valve states MSG_ID_DG_START_STOP_TRIMMER_HEATER_CMD = 0x2B, ///< HD request to DG to start/stop trimmer heater - MSG_ID_DG_HEATERS_DATA = 0x2C, ///< DG broadcast of the heaters data - MSG_ID_DG_TEMPERATURE_DATA = 0x2D, ///< DG broadcast of the temperature sensors data + MSG_ID_DG_HEATERS_DATA = 0x2C, ///< DG broadcast of the heaters data + MSG_ID_DG_TEMPERATURE_DATA = 0x2D, ///< DG broadcast of the temperature sensors data MSG_ID_USER_UF_SETTINGS_CHANGE_CONFIRMATION_RESPONSE = 0x2E, ///< HD response to user selection of ultrafiltration settings change option selection MSG_ID_SALINE_BOLUS_DATA = 0x2F, ///< HD broadcast of saline bolus data MSG_ID_DG_START_STOP_HEAT_DISINFECT = 0x30, ///< HD request to start or stop DG heat disinfection - MSG_ID_DG_CONDUCTIVITY_DATA = 0x31, ///< DG broadcast of the conductivity sensors data - MSG_ID_USER_REQUEST_ALARM_SILENCE = 0x32, ///< UI request alarm silence (or cancel) - MSG_ID_HD_ACCELEROMETER_DATA = 0x33, ///< HD broadcast of accelerometer data - MSG_ID_DG_ACCELEROMETER_DATA = 0x34, ///< DG broadcast of accelerometer data - MSG_ID_UI_NEW_TREATMENT_PARAMS = 0x35, ///< UI request to validate new treatment parameter set + MSG_ID_DG_CONDUCTIVITY_DATA = 0x31, ///< DG broadcast of the conductivity sensors data + MSG_ID_USER_REQUEST_ALARM_SILENCE = 0x32, ///< UI request alarm silence (or cancel) + MSG_ID_HD_ACCELEROMETER_DATA = 0x33, ///< HD broadcast of accelerometer data + MSG_ID_DG_ACCELEROMETER_DATA = 0x34, ///< DG broadcast of accelerometer data + MSG_ID_UI_NEW_TREATMENT_PARAMS = 0x35, ///< UI request to validate new treatment parameter set MSG_ID_HD_NEW_TREATMENT_PARAMS_RESPONSE = 0x36, ///< HD response to new treatment parameters set MSG_ID_DG_HEAT_DISINFECT_DATA = 0x37, ///< DG heat disinfect publish data MSG_ID_UI_INITIATE_TREATMENT_REQUEST = 0x38, ///< UI user request to initiate a treatment @@ -149,22 +158,74 @@ MSG_ID_UI_TREATMENT_LOG_DATA_REQUEST = 0x75, ///< UI request treatment log data message MSG_ID_HD_TREATMENT_LOG_DATA_RESPONSE = 0x76, ///< HD response to UI treatment log data request MSG_ID_HD_POST_TREATMENT_STATE = 0x77, ///< HD broadcast of post-treatment state - MSG_ID___AVAILABLE_16 = 0x78, ///< This msg ID is available for use + MSG_ID_DG_START_STOP_CHEM_DISINFECT = 0x78, ///< DG start/stop chemical disinfection MSG_ID_DG_START_STOP_FLUSH = 0x79, ///< DG start/stop flush mode MSG_ID_DG_FLUSH_DATA = 0x7A, ///< DG flush data publish MSG_ID_HD_VOLTAGES_DATA = 0x7B, ///< HD voltages data publish MSG_ID_HD_ALARM_AUDIO_VOLUME_SET_RESPONSE = 0x7C, ///< HD response to UI set alarm audio volume request MSG_ID_HD_ALARM_INFORMATION = 0x7D, ///< HD alarm information broadcast message + MSG_ID_HD_DISINFECT_STANDBY_DATA = 0x7E, ///< HD broadcast of standby disinfect data + MSG_ID_UI_DISINFECT_REQUEST = 0x7F, ///< UI disinfection selection + MSG_ID_HD_DISINFECT_RESPONSE = 0x80, ///< HD response to disinfection selection + MSG_ID_UI_CHEM_DISINFECT_CONFIRM = 0x81, ///< UI confirmation of chemical disinfection start + MSG_ID_HD_CHEM_DISINFECT_CONFIRM_RESPONSE = 0x82, ///< HD response to confirmation of chemical disinfection start + MSG_ID_DG_FLUSH_TIME_DATA = 0x83, ///< DG broadcast of flush mode time data + MSG_ID_DG_HEAT_DISINFECT_TIME_DATA = 0x84, ///< DG broadcast of heat disinfection mode time data + MSG_ID_DG_CHEM_DISINFECT_TIME_DATA = 0x85, ///< DG broadcast of chemical disinfection mode time data MSG_ID_DG_VOLTAGES_DATA = 0x86, ///< DG voltages data publish + MSG_ID_DG_CHEM_DISINFECT_DATA = 0x87, ///< DG chemical disinfect data publish + MSG_ID_DG_SERIAL_NUMBER = 0x88, ///< DG serial number + MSG_ID_UI_REQUEST_SERVICE_INFO = 0x89, ///< UI request for service schedule information + MSG_ID_HD_SERVICE_SCHEDULE_DATA = 0x8A, ///< HD service schedule data + MSG_ID_HD_USAGE_DATA = 0x8B, ///< HD usage data TODO is this needed? + MSG_ID_DG_SERVICE_SCHEDULE_DATA = 0x8C, ///< DG service schedule data + MSG_ID_DG_USAGE_DATA = 0x8D, ///< DG usage data TODO is this needed? + MSG_ID_HD_POST_SINGLE_TEST_RESULT = 0x8E, ///< HD POST single test result + MSG_ID_HD_POST_FINAL_TEST_RESULT = 0x8F, ///< HD POST final test result + MSG_ID_DG_POST_SINGLE_TEST_RESULT = 0x90, ///< DG POST single test result + MSG_ID_DG_POST_FINAL_TEST_RESULT = 0x91, ///< DG POST final test result + MSG_ID_UI_POST_FINAL_TEST_RESULT = 0x92, ///< UI POST final test result + MSG_ID_HD_BUBBLES_DATA = 0x93, ///< HD broadcast of air bubble detectors data + MSG_ID_HD_TREATMENT_LOG_PERIODIC_DATA = 0x94, ///< HD broadcast of treatment log period data + MSG_ID_HD_TREATMENT_LOG_ALARM_EVENT = 0x95, ///< HD treatment log alarm event + MSG_ID_HD_TREATMENT_LOG_EVENT = 0x96, ///< HD treatment log event + MSG_ID_UI_ACTIVE_ALARMS_LIST_REQUEST = 0x97, ///< UI active alarms list request + MSG_ID_HD_ACTIVE_ALARMS_LIST_REQUEST_RESPONSE = 0x98, ///< HD active alarms list request response + MSG_ID_HD_SERIAL_NUMBER = 0x99, ///< HD serial number + MSG_ID_HD_SET_STANDBY_DISINFECT_SUB_MODE_REQUEST = 0x9A, ///< HD set standby disinfect submode request + MSG_ID_HD_SET_STANDBY_DISINFECT_SUB_MODE_RESPONSE = 0x9B, ///< HD set standby disinfect submode response + MSG_ID_HD_DG_POST_RESULT_REQUEST = 0x9C, ///< HD request for DG POST final result (reported back on msg 0x91) + MSG_ID_HD_TEMPERATURES_DATA = 0x9D, ///< HD temperatures data + MSG_ID_HD_UI_VERSION_INFO_REQUEST = 0x9E, ///< HD request for UI version information + MSG_ID_HD_UI_VERSION_INFO_RESPONSE = 0x9F, ///< UI response to HD request for version information + MSG_ID_REQUEST_HD_USAGE_INFO = 0xA0, ///< HD request usage information + MSG_ID_DG_SWITCHES_DATA = 0xA1, ///< DG switches data publish + MSG_ID_HD_SWITCHES_DATA = 0xA2, ///< HD switches data publish + MSG_ID_HD_FANS_DATA = 0xA3, ///< HD fans data publish + MSG_ID_HD_EVENT = 0xA4, ///< HD general event + MSG_ID_DG_EVENT = 0xA5, ///< DG general event + MSG_ID_DG_DIALYSATE_FLOW_METER_DATA = 0xA6, ///< DG dialysate flow meter data (liter/minute) + MSG_ID_DG_ALARM_INFO = 0xA7, ///< DG alarm information data publish + MSG_ID_HD_RESERVOIRS_DATA = 0xA8, ///< HD reservoirs data publish + MSG_ID_HD_REQUEST_DG_CONCENTRATE_MIXING_RATIOS = 0xA9, ///< HD request DG concentrate ratios + MSG_ID_DG_CONCENTRATE_MIXING_RATIOS_DATA = 0xAA, ///< DG concentrate mixing ratios data + MSG_ID_DG_SCHEDULED_RUNS_DATA = 0xAB, ///< DG scheduled runs data + MSG_ID_DG_SCHEDULED_RUNS_INFO = 0xAC, ///< DG scheduled runs info to be sent to the UI and Dialin + MSG_ID_UI_INSTALLATION_CONFIRM_RESPONSE = 0xAD, ///< HD Confirm installation response + MSG_ID_DG_FILL_MODE_DATA = 0xAE, ///< DG broadcast of fill mode data such as used acid & bicarb volume + MSG_ID_DG_BAD_FILL_SUB_STATE = 0xAF, ///< DG broadcast of idle mode bad fill sub-state + MSG_ID_UI_REQUEST_SERVICE_MODE = 0xB0, ///< UI request to HD to go to service mode + MSG_ID_HD_RESPONSE_SERVICE_MODE_REQUEST = 0xB1, ///< HD response to UI request to go to service mode + MSG_ID_AVAILABLE = 0xB2, ///< Message ID is available for use -#ifdef EMC_TEST_BUILD - MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing -#endif - - // service/test CAN messages +#ifdef EMC_TEST_BUILD + MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing +#endif + + // service/test CAN messages MSG_ID_FIRST_TESTER_MESSAGE = 0x8000, ///< First HD test message ID MSG_ID_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_TESTER_MESSAGE, ///< HD tester log-in - MSG_ID_DIAL_OUT_FLOW_SET_PT_OVERRIDE = 0x8001, ///< Dialysate outlet flow set point override request + MSG_ID_DIAL_OUT_FLOW_SET_PT_OVERRIDE = 0x8001, ///< Dialysate outlet flow set point override request MSG_ID_OFF_BUTTON_STATE_OVERRIDE = 0x8002, ///< Off button override request MSG_ID_STOP_BUTTON_STATE_OVERRIDE = 0x8003, ///< Stop button override request MSG_ID_ALARM_LAMP_PATTERN_OVERRIDE = 0x8004, ///< Alarm lamp pattern override request @@ -189,8 +250,8 @@ MSG_ID_PRESSURE_ARTERIAL_OVERRIDE = 0x8017, ///< Arterial pressure measured override request MSG_ID_PRESSURE_VENOUS_OVERRIDE = 0x8018, ///< Venous pressure measured override request MSG_ID_OCCLUSION_BLOOD_PUMP_OVERRIDE = 0x8019, ///< Blood pump occlusion pressure measured override request - MSG_ID_OCCLUSION_DIAL_IN_PUMP_OVERRIDE = 0x801A, ///< Dialysate inlet pump occlusion pressure measured override request - MSG_ID_OCCLUSION_DIAL_OUT_PUMP_OVERRIDE = 0x801B, ///< Dialysate outlet pump occlusion pressure measured override request + MSG_ID_BLOOD_ROTOR_COUNT_OVERRIDE = 0x801A, ///< Blood pump rotor count override request + MSG_ID_SET_ARTERIAL_PRESSURE_OFFSET = 0x801B, ///< Set arterial pressure offset request MSG_ID_PRES_OCCL_SEND_INTERVAL_OVERRIDE = 0x801C, ///< Pressure and occlusion broadcast interval override request MSG_ID_SET_RTC_DATE_TIME = 0x801D, ///< RTC set date/time request MSG_ID_DIAL_OUT_FLOW_SEND_INTERVAL_OVERRIDE = 0x801E, ///< Dialysate outlet flow broadcast interval override request @@ -201,12 +262,12 @@ MSG_ID_DIAL_OUT_PUMP_MEAS_SPEED_OVERRIDE = 0x8023, ///< Dialysate outlet pump measured motor speed override request MSG_ID_DIAL_OUT_PUMP_MEAS_ROTOR_SPEED_OVERRIDE = 0x8024, ///< Dialysate outlet pump measured rotor speed override request MSG_ID_DIAL_OUT_LOAD_CELL_WEIGHT_OVERRIDE = 0x8025, ///< Load cell measured weight override request - MSG_ID_HD_SAFETY_SHUTDOWN_OVERRIDE = 0x8026, ///< HD safety shutdown override request - MSG_ID_HD_ACCEL_OVERRIDE = 0x8027, ///< HD accelerometer sensor override request - MSG_ID_HD_ACCEL_MAX_OVERRIDE = 0x8028, ///< HD accelerometer sensor max. override request - MSG_ID_HD_ACCEL_SEND_INTERVAL_OVERRIDE = 0x8029, ///< HD accelerometer data broadcast interval override request - MSG_ID_HD_SYRINGE_PUMP_SEND_INTERVAL_OVERRIDE = 0x802A, ///< HD syringe pump data broadcast interval override request - MSG_ID_HD_SYRINGE_PUMP_OPERATION_REQUEST = 0x802B, ///< HD syringe pump operation request + MSG_ID_HD_SAFETY_SHUTDOWN_OVERRIDE = 0x8026, ///< HD safety shutdown override request + MSG_ID_HD_ACCEL_OVERRIDE = 0x8027, ///< HD accelerometer sensor override request + MSG_ID_HD_ACCEL_MAX_OVERRIDE = 0x8028, ///< HD accelerometer sensor max. override request + MSG_ID_HD_ACCEL_SEND_INTERVAL_OVERRIDE = 0x8029, ///< HD accelerometer data broadcast interval override request + MSG_ID_HD_SYRINGE_PUMP_SEND_INTERVAL_OVERRIDE = 0x802A, ///< HD syringe pump data broadcast interval override request + MSG_ID_HD_SYRINGE_PUMP_OPERATION_REQUEST = 0x802B, ///< HD syringe pump operation request MSG_ID_HD_SYRINGE_PUMP_MEASURED_RATE_OVERRIDE = 0x802C, ///< HD syringe pump measured rate override request MSG_ID_HD_SET_PARAMETER_TREATMENT_PARAMETER = 0x802D, ///< Set a treatment parameter (will change actual setting, not an override) MSG_ID_HD_VALVES_HOME = 0x802E, ///< Home an HD Valve @@ -216,8 +277,8 @@ MSG_ID_HD_AIR_TRAP_SEND_INTERVAL_OVERRIDE = 0x8032, ///< HD air trap data broadcast interval override request MSG_ID_HD_AIR_TRAP_LEVEL_SENSOR_OVERRIDE = 0x8033, ///< HD air trap level sensor override request MSG_ID_HD_SOFTWARE_RESET_REQUEST = 0x8034, ///< HD reset request - MSG_ID_BLOOD_FLOW_SIG_STRENGTH_OVERRIDE = 0x8035, ///< Blood flow signal strength override request - MSG_ID_DIAL_IN_FLOW_SIG_STRENGTH_OVERRIDE = 0x8036, ///< Dialysate flow signal strength override request + MSG_ID_HD_GET_SW_CONFIG_RECORD = 0x8035, ///< HD get software configuration record. + MSG_ID_HD_SET_SW_CONFIG_RECORD = 0x8036, ///< HD set software configuration record. MSG_ID_BLOOD_PUMP_HOME_CMD = 0x8037, ///< Blood pump home command MSG_ID_DIAL_IN_PUMP_HOME_CMD = 0x8038, ///< Dialysate inlet pump home command MSG_ID_DIAL_OUT_PUMP_HOME_CMD = 0x8039, ///< Dialysate outlet pump home command @@ -250,8 +311,51 @@ MSG_ID_HD_ALARM_AUDIO_CURRENT_LG_OVERRIDE = 0x8055, ///< HD primary alarm audio (low gain) current override request MSG_ID_HD_ALARM_BACKUP_AUDIO_CURRENT_OVERRIDE = 0x8056, ///< HD backup alarm audio current override request MSG_ID_HD_VALVES_CURRENT_OVERRIDE = 0x8057, ///< HD valves current override request - MSD_ID_HD_VALVES_POSITION_COUNT_OVERRIDE = 0x8058, ///< HD valves position counts override request - + MSG_ID_HD_VALVES_POSITION_COUNT_OVERRIDE = 0x8058, ///< HD valves position counts override request + MSG_ID_HD_SYRINGE_PUMP_STATUS_OVERRIDE = 0x8059, ///< HD syringe pump status override request + MSG_ID_HD_SYRINGE_PUMP_ENCODER_STATUS_OVERRIDE = 0x805A, ///< HD syringe pump encoder status override request + MSG_ID_HD_SYRINGE_PUMP_ADC_DAC_STATUS_OVERRIDE = 0x805B, ///< HD syringe pump ADC and DAC status override request + MSG_ID_HD_SYRINGE_PUMP_ADC_READ_COUNTER_OVERRIDE = 0x805C, ///< HD syringe pump ADC read counter override request + MSG_ID_HD_BUBBLES_DATA_SEND_INTERVAL_OVERRIDE = 0x805D, ///< HD air bubble detectors data broadcast interval override request + MSG_ID_HD_BUBBLE_STATUS_OVERRIDE = 0x805E, ///< HD air bubble detector status override request + MSG_ID_HD_BLOOD_PRIME_VOLUME_OVERRIDE = 0x805F, ///< HD blood prime volume override request + MSG_ID_HD_BUBBLE_SELF_TEST_REQUEST = 0x8060, ///< HD air bubble detector self-test request + MSG_ID_HD_FAN_RPM_ALARM_START_TIME_OFFSET_OVERRIDE = 0x8061, ///< HD fan RPM alarm start time override request TODO remove once DEN-12224 merged into staging + MSG_ID_HD_SWITCHES_STATUS_OVERRIDE = 0x8062, ///< HD switches status override request + MSG_ID_HD_SWITCHES_PUBLISH_INTERVAL_OVERRIDE = 0x8063, ///< HD switches data publish override request + MSG_ID_HD_BATTERY_REMAINING_PERCENT_OVERRIDE = 0x8064, ///< HD battery remaining percent override request + MSG_ID_HD_TEMPERATURES_VALUE_OVERRIDE = 0x8065, ///< HD temperatures value override request + MSG_ID_HD_TEMPERATURES_PUBLISH_INTERVAL_OVERRIDE = 0x8066, ///< HD temperatures data publish override request + MSG_ID_HD_FANS_PUBLISH_INTERVAL_OVERRIDE = 0x8067, ///< HD fans data publish override request + MSG_ID_HD_FANS_RPM_OVERRIDE = 0x8068, ///< HD fans RPM override request + MSG_ID_HD_RINSEBACK_VOLUME_OVERRIDE = 0x8069, ///< HD rinseback volume override request + MSG_ID_HD_SEND_SW_CONFIG_RECORD = 0x806A, ///< HD send software configuration record. + MSG_ID_HD_ALARM_STATUS_PUBLISH_INTERVAL_OVERRIDE = 0x806B, ///< HD alarm status publish interval override request + MSG_ID_HD_TREATMENT_TIME_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x806C, ///< HD treatment time data publish interval override request + MSG_ID_HD_TREATMENT_RANGES_PUBLISH_INTERVAL_OVERRIDE = 0x806D, ///< HD treatment param adjustment ranges publish interval override request + MSG_ID_HD_TREATMENT_STOP_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x806E, ///< HD treatment stop sub-mode data publish interval override request + MSG_ID_HD_BLOOD_PRIME_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x806F, ///< HD treatment blood prime sub-mode data publish interval override request + MSG_ID_HD_RINSEBACK_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8070, ///< HD treatment rinseback sub-mode data publish interval override request + MSG_ID_HD_STANDBY_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8071, ///< HD standby mode data publish interval override request + MSG_ID_HD_OP_MODE_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8072, ///< HD operation mode data publish interval override request + MSG_ID_HD_PRE_TREATMENT_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8073, ///< HD pre-treatment mode data publish interval override request + MSG_ID_HD_TREATMENT_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8074, ///< HD treatment mode data publish interval override request + MSG_ID_HD_POST_TREATMENT_DATA_PUBLISH_INTERVAL_OVERRIDE = 0x8075, ///< HD post treatment mode data publish interval override request + MSG_ID_HD_BLOCK_MESSAGE_TRANSMISSION = 0x8076, ///< HD prevent transmission of given message(s) + MSG_ID_HD_SYRINGE_PUMP_FORCE_SENSOR_DAC_CALIBRATE = 0x8077, ///< HD set syringe pump force sensor DAC calibration + MSG_ID_HD_STOP_RTC_CLOCK = 0x8078, ///< HD stop RTC clock + MSG_ID_HD_FANS_DUTY_CYCLE_OVERRIDE = 0x8079, ///< HD fans duty cycle override request + MSG_ID_HD_SYRINGE_PUMP_HEPRIN_BOLUS_TARGET_RATE_OVERRIDE = 0x807A, ///< HD heprin bolus target rate override request + MSG_ID_HD_REQ_CURRENT_TREATMENT_PARAMETERS = 0x807B, ///< HD request current treatment parameters + MSG_ID_HD_RES_CURRENT_TREATMENT_PARAMETERS = 0x807C, ///< HD current treatment paramaters response + MSG_ID_HD_SET_FANS_RPM_ALARM_START_TIME_OFFSET = 0x807D, ///< HD set fans RPM alarm start time offset + MSG_ID_HD_GET_USAGE_INFO_RECORD = 0x807E, ///< HD get usage information record + MSG_ID_HD_SET_USAGE_INFO_RECORD = 0x807F, ///< HD set usage information record + MSG_ID_HD_SEND_USAGE_INFO_RECORD = 0x8080, ///< HD send usage information record + MSG_ID_HD_SET_BLOOD_LEAK_2_EMB_MODE = 0x8081, ///< HD set blood leak sensor to embedded mode + MSG_ID_HD_SET_BLOOD_LEAK_EMB_MODE_COMMAND = 0x8082, ///< HD set blood leak embedded mode command + MSG_ID_HD_SEND_BLOOD_LEAK_EMB_MODE_RESPONSE = 0x8083, ///< HD send blood leak embedded mode response + MSG_ID_FIRST_DG_TESTER_MESSAGE = 0xA000, ///< First DG test message ID MSG_ID_DG_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DG_TESTER_MESSAGE, ///< DG tester log-in MSG_ID_DG_ALARM_STATE_OVERRIDE = 0xA001, ///< DG alarm state override message ID @@ -260,31 +364,32 @@ MSG_ID_LOAD_CELL_OVERRIDE = 0xA005, ///< Load cell sensor override request MSG_ID_PRESSURE_OVERRIDE = 0xA006, ///< Pressure sensor override request MSG_ID_PRESSURE_SEND_INTERVAL_OVERRIDE = 0xA007, ///< Pressure data broadcast interval override request + MSG_ID_DG_HD_COMMUNICATION_STATUS_OVERRIDE = 0xA008, ///< DG HD Communication Status override MSG_ID_RO_MEASURED_FLOW_OVERRIDE = 0xA009, ///< RO measured flow rate override request MSG_ID_RO_PUMP_SEND_INTERVAL_OVERRIDE = 0xA00A, ///< RO pump data broadcast interval override request - MSG_ID_DRAIN_PUMP_SET_RPM_OVERRIDE = 0xA00B, ///< Drain pump set RPM override request + MSG_ID_DRAIN_PUMP_SET_RPM = 0xA00B, ///< Drain pump set RPM override request MSG_ID_DRAIN_PUMP_SEND_INTERVAL_OVERRIDE = 0xA00C, ///< Drain pump data broadcast interval override request MSG_ID_LOAD_CELLL_SEND_INTERVAL_OVERRIDE = 0xA00D, ///< Load cell data broadcast interval override request MSG_ID_VALVE_STATE_OVERRIDE = 0xA00E, ///< Valve state override request MSG_ID_VALVES_STATES_PUBLISH_INTERVAL_OVERRIDE = 0xA00F, ///< Valve data broadcast interval override request MSG_ID_TEMPERATURE_SENSORS_VALUE_OVERRIDE = 0xA010, ///< Temperature sensor override request - MSG_ID_START_STOP_PRIMARY_HEATER = 0xA011, ///< Start/stop primary heaters - MSG_ID_TEMPERATURE_SENSORS_PUBLISH_INTERVAL_OVERRIDE = 0xA012, ///< Temperature sensors data publish override - MSG_ID_HEATERS_PUBLISH_INTERVAL_ORVERRIDE = 0xA013, ///< Heaters data publish override + MSG_ID_START_STOP_PRIMARY_HEATER = 0xA011, ///< Start/stop primary heaters + MSG_ID_TEMPERATURE_SENSORS_PUBLISH_INTERVAL_OVERRIDE = 0xA012, ///< Temperature sensors data publish override + MSG_ID_HEATERS_PUBLISH_INTERVAL_ORVERRIDE = 0xA013, ///< Heaters data publish override MSG_ID_DG_SAFETY_SHUTDOWN_OVERRIDE = 0xA014, ///< DG safety shutdown override request MSG_ID_CONDUCTIVITY_OVERRIDE = 0xA015, ///< Conductivity sensor override request - MSG_ID_CONDUCTIVITY_PUBLISH_INTERVAL_OVERRIDE = 0xA016, ///< Conductivity sensors data publish override - MSG_ID_DG_ACCEL_OVERRIDE = 0xA017, ///< DG accelerometer sensor override request - MSG_ID_DG_ACCEL_MAX_OVERRIDE = 0xA018, ///< DG accelerometer sensor max. override request - MSG_ID_DG_ACCEL_SEND_INTERVAL_OVERRIDE = 0xA019, ///< DG accelerometer data broadcast interval override request + MSG_ID_CONDUCTIVITY_PUBLISH_INTERVAL_OVERRIDE = 0xA016, ///< Conductivity sensors data publish override + MSG_ID_DG_ACCEL_OVERRIDE = 0xA017, ///< DG accelerometer sensor override request + MSG_ID_DG_ACCEL_MAX_OVERRIDE = 0xA018, ///< DG accelerometer sensor max. override request + MSG_ID_DG_ACCEL_SEND_INTERVAL_OVERRIDE = 0xA019, ///< DG accelerometer data broadcast interval override request MSG_ID_DG_MONITORED_VOLTAGES_SEND_INTERVAL_OVERRIDE = 0xA01A, ///< DG monitored voltages publish interval override request MSG_ID_DG_MONITORED_VOLTAGES_OVERRIDE = 0xA01B, ///< DG monitored voltage override request - MSG_ID_DRAIN_PUMP_SET_DELTA_PRESSURE_OVERRIDE = 0xA01C, ///< Drain pump set delta pressure override - MSG_ID___AVAILABLE_12 = 0xA01D, ///< This msg ID is available for use - MSG_ID___AVAILABLE_13 = 0xA01E, ///< This msg ID is available for use - MSG_ID___AVAILABLE_14 = 0xA01F, ///< This msg ID is available for use - MSG_ID___AVAILABLE_15 = 0xA020, ///< This msg ID is available for use - MSG_ID_HEAT_DISINFECT_PUBLISH_INTERVAL_OVERRIDE = 0xA021, ///< Heat disinfection data publish interval override request + MSG_ID_DRAIN_PUMP_TARGET_OUTLET_PRESSURE = 0xA01C, ///< Drain pump target outlet pressure. + MSG_ID_DG_SWITCHES_STATUS_OVERRIDE = 0xA01D, ///< DG switches status override + MSG_ID_DG_SWITCHES_PUBLISH_INTERVAL_OVERRIDE = 0xA01E, ///< DG switches data publish interval override + MSG_ID_DG_OP_MODE_PUBLISH_INTERVAL_OVERRIDE = 0xA01F, ///< DG operation mode publish interval override + MSG_ID_DG_BLOCK_MESSAGE_TRANSMISSION = 0xA020, ///< HD prevent transmission of given message(s) + MSG_ID_DIALYSATE_MEASURED_FLOW_OVERRIDE = 0xA021, ///< DG dialysate measured flow rate override request MSG_ID_DG_SOFTWARE_RESET_REQUEST = 0xA022, ///< DG reset request MSG_ID_DG_CONCENTRATE_PUMP_MEASURED_SPEED_OVERRIDE = 0xA023, ///< DG concentrate pump measured speed override request MSG_ID_CONCENTRATE_PUMP_TARGET_SPEED_OVERRIDE = 0xA024, ///< Concentrate pumps' target speed override request @@ -299,7 +404,7 @@ MSG_ID_DG_THERMISTORS_VALUE_OVERRIDE = 0xA02E, ///< DG thermistors value override MSG_ID_DG_RO_PUMP_DUTY_CYCLE_OVERRIDE = 0xA02F, ///< DG RO pump duty cycle override MSG_ID_DG_RO_FLOW_RATE_OVERRIDE = 0xA030, ///< DG RO flow rate override - MSG_ID_DG_RO_PUMP_TARGET_FLOW_OVERRIDE = 0xA031, ///< DG RO pump target flow rate override + MSG_ID_DG_SET_RO_PUMP_TARGET_FLOW = 0xA031, ///< DG set RO pump target flow rate MSG_ID_DG_RO_PUMP_TARGET_PRESSURE_OVERRIDE = 0xA032, ///< DG RO pump target pressure override MSG_ID_DG_SET_CALIBRATION_RECORD = 0xA033, ///< DG set calibration record that is received from Dialin MSG_ID_DG_GET_CALIBRATION_RECORD = 0xA034, ///< DG get calibration record that is requested from Dialin @@ -316,19 +421,39 @@ MSG_ID_DG_FLUID_LEAK_SEND_INTERVAL_OVERRIDE = 0xA03F, ///< DG fluid leak state broadcast interval override request MSG_ID_DG_FLUID_LEAK_STATE_DETECTOR_OVERRIDE = 0xA040, ///< DG fluid leak state detector override request MSG_ID_DG_FLUSH_PUBLISH_INTERVAL_OVERRIDE = 0xA041, ///< DG flush mode data publish interval override - + MSG_ID_FILTER_FLUSH_TIME_PERIOD_OVERRIDE = 0xA042, ///< DG filter flush time period override + MSG_ID_DG_FANS_RPM_OVERRIDE = 0xA043, ///< DG fans RPM override + MSG_ID_DIALYSATE_FLOW_SEND_INTERVAL_OVERRIDE = 0xA044, ///< Dialysate flow data broadcast interval override request + MSG_ID_DG_STOP_RTC_CLOCK = 0xA045, ///< DG stop RTC clock + MSG_ID_DG_DRAIN_PUMP_MEASURED_RPM_OVERRIDE = 0xA046, ///< DG drain pump measured RPM override + MSG_ID_DG_SUPER_CLEAR_ALARMS_CMD = 0xA047, ///< Clears all DG alarms (even if non-recoverable or fault) + MSG_ID_DG_ALARM_INFO_SEND_INTERVAL_OVERRIDE = 0xA048, ///< DG alarm information broadcast interval override request + MSG_ID_DG_FAN_RPM_ALARM_START_TIME_OFFSET_OVERRIDE = 0xA049, ///< DG fan RPM alarm start time offset override request // TODO remove once DEN-12224 is implemented + MSG_ID_DG_GET_SW_CONFIG_RECORD = 0xA04A, ///< DG get software configuration record request + MSG_ID_DG_SET_SW_CONFIG_RECORD = 0xA04B, ///< DG set software configuration record + MSG_ID_DG_SEND_SW_CONFIG_RECORD = 0xA04C, ///< DG send software configuration record + MSG_ID_DG_FANS_DUTY_CYCLE_OVERRIDE = 0xA04D, ///< DG fans duty cycle override request + MSG_ID_DG_USED_ACID_VOLUME_ML_OVERRIDE = 0xA04E, ///< DG used acid volume override in mL + MSG_ID_DG_SET_FANS_RPM_ALARM_START_TIME_OFFSET = 0xA04F, ///< DG set fans RPM alarm start time offset + MSG_ID_DG_USED_BICARB_VOLUME_ML_OVERRIDE = 0xA050, ///< DG used bicarb volume override in mL + MSG_ID_FILL_MODE_DATA_PUBLISH_INTERVAL_OVERRIDE = 0xA051, ///< DG used concentrate publish interval override request + MSG_ID_BAD_FILL_STATES_PUBLISH_INTERVAL_OVERRIDE = 0xA052, ///< DG bad fill sub-states publish interval override request + MSG_ID_DG_GET_USAGE_INFO_RECORD = 0xA053, ///< DG get usage information record + MSG_ID_DG_SET_USAGE_INFO_RECORD = 0xA054, ///< DG set usage information record + MSG_ID_DG_SEND_USAGE_INFO_RECORD = 0xA055, ///< DG send usage information record + MSG_ID_HD_DEBUG_EVENT = 0xFFF1, ///< HD debug event text to be logged in event log MSG_ID_DG_DEBUG_EVENT = 0xFFF2, ///< DG debug event text to be logged in event log MSG_ID_ACK_MESSAGE_THAT_REQUIRES_ACK = 0xFFFF, ///< Acknowledgment of message that requires acknowledgment - + END_OF_MSG_IDS ///< End of system message IDs }; typedef enum Msg_IDs MSG_ID_T; ///< Type for message IDs enumeration /// Enumeration of settings change rejection reason codes -enum Request_Reject_Reasons -{ +enum Request_Reject_Reasons +{ REQUEST_REJECT_REASON_NONE = 0, ///< Used when there is no rejection REQUEST_REJECT_REASON_NOT_ALLOWED_IN_CURRENT_MODE = 1, ///< Request is not allowed in the current operating mode REQUEST_REJECT_REASON_TIMEOUT_WAITING_FOR_USER_CONFIRM = 2, ///< Validated request was not confirmed by user in reasonable time @@ -356,13 +481,25 @@ REQUEST_REJECT_REASON_ALARM_IS_ACTIVE = 24, ///< Requested user action not allowed while alarm is active REQUEST_REJECT_REASON_INVALID_COMMAND = 25, ///< Requested user action invalid REQUEST_REJECT_REASON_TREATMENT_IS_COMPLETED = 26, ///< The treatment has been completed - REQUEST_REJECT_REASON_RINSEBACK_MAX_VOLUME_REACHED = 27, ///< Rinseback volume maximum has been reached - no more additional rinsebacks allowed + REQUEST_REJECT_REASON_ADDL_RINSEBACK_MAX_VOLUME_REACHED = 27, ///< Rinseback additional volume maximum has been reached - no more additional rinsebacks allowed REQUEST_REJECT_REASON_UF_VOLUME_NOT_SET = 28, ///< Ultrafiltration volume is not set yet REQUEST_REJECT_REASON_NO_PATIENT_CONNECTION_CONFIRM = 29, ///< The user has not confirmed patient connection REQUEST_REJECT_REASON_HEPARIN_PAUSE_INVALID_IN_THIS_STATE = 30, ///< Heparin cannot be paused if not currently deliverying Heparin REQUEST_REJECT_REASON_HEPARIN_NOT_PAUSED = 31, ///< Heparin cannot be resumed if not paused REQUEST_REJECT_REASON_DG_COMM_LOST = 32, ///< Treatment cannot initiate if DG comm is lost REQUEST_REJECT_REASON_DRAIN_NOT_COMPLETE = 33, ///< Post-treatment reservoirs drain not complete + REQUEST_REJECT_REASON_DG_NOT_IN_STANDBY_IDLE_STATE = 34, ///< Treatment cannot initiate if DG is not in standby idle state + REQUEST_REJECT_REASON_INVALID_REQUEST_FORMAT = 35, ///< Request message not formatted properly + REQUEST_REJECT_REASON_INVALID_DATE_OR_TIME = 36, ///< Given date/time is invalid + REQUEST_REJECT_REASON_TREATMENT_IN_PROGRESS = 37, ///< Treatment is in progress + REQUEST_REJECT_REASON_BATTERY_IS_NOT_CHARGED = 38, ///< Battery does not have enough charge to start treatment + REQUEST_REJECT_REASON_RINSEBACK_NOT_COMPLETED = 39, ///< Cannot move on to recirculate without completing full rinseback. + REQUEST_REJECT_REASON_RESERVOIR_ONE_IS_NOT_READY = 40, ///< Reservoir one fill is not complete + REQUEST_REJECT_REASON_PUMP_TRACK_NOT_CLOSED = 41, ///< Pump track is not ready / closed + REQUEST_REJECT_REASON_DOOR_NOT_CLOSED = 42, ///< Door is not closed + REQUEST_REJECT_REASON_SYRINGE_NOT_PRESENT = 43, ///< Syringe is not present + REQUEST_REJECT_REASON_DG_DIALYSATE_CAP_OPEN = 44, ///< Dialysate cap open + REQUEST_REJECT_REASON_DG_CONCENTRATE_CAP_OPEN = 45, ///< Concentrate cap open NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration @@ -378,5 +515,5 @@ typedef enum Cmd_Request_Reject_Reasons CMD_REQUEST_REJECT_REASON_CODE_T; ///< Type for command request rejection reason codes enumeration /**@}*/ - -#endif + +#endif