Index: MsgDefs.h =================================================================== diff -u -r9a599408dbb9fa8cf607e1ed18d499aa59c65633 -r87782635fa31d480f1a60f2ffb2558f48940fb47 --- MsgDefs.h (.../MsgDefs.h) (revision 9a599408dbb9fa8cf607e1ed18d499aa59c65633) +++ MsgDefs.h (.../MsgDefs.h) (revision 87782635fa31d480f1a60f2ffb2558f48940fb47) @@ -149,13 +149,14 @@ MSG_ID_UI_TREATMENT_LOG_DATA_REQUEST = 0x75, ///< UI request treatment log data message MSG_ID_HD_TREATMENT_LOG_DATA_RESPONSE = 0x76, ///< HD response to UI treatment log data request MSG_ID_HD_POST_TREATMENT_STATE = 0x77, ///< HD broadcast of post-treatment state - MSG_ID___AVAILABLE_16 = 0x78, ///< This msg ID is available for use + MSG_ID_DG_START_STOP_CHEM_DISINFECT = 0x78, ///< DG start/stop chemical disinfect MSG_ID_DG_START_STOP_FLUSH = 0x79, ///< DG start/stop flush mode MSG_ID_DG_FLUSH_DATA = 0x7A, ///< DG flush data publish MSG_ID_HD_VOLTAGES_DATA = 0x7B, ///< HD voltages data publish MSG_ID_HD_ALARM_AUDIO_VOLUME_SET_RESPONSE = 0x7C, ///< HD response to UI set alarm audio volume request MSG_ID_HD_ALARM_INFORMATION = 0x7D, ///< HD alarm information broadcast message MSG_ID_DG_VOLTAGES_DATA = 0x86, ///< DG voltages data publish + MSG_ID_DG_CHEM_DISINFECT_DATA = 0x87, ///< DG chemical disinfect data publish #ifdef EMC_TEST_BUILD MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing @@ -249,6 +250,8 @@ MSG_ID_HD_ALARM_AUDIO_CURRENT_HG_OVERRIDE = 0x8054, ///< HD primary alarm audio (high gain) current override request MSG_ID_HD_ALARM_AUDIO_CURRENT_LG_OVERRIDE = 0x8055, ///< HD primary alarm audio (low gain) current override request MSG_ID_HD_ALARM_BACKUP_AUDIO_CURRENT_OVERRIDE = 0x8056, ///< HD backup alarm audio current override request + MSG_ID_HD_VALVES_CURRENT_OVERRIDE = 0x8057, ///< HD valves current override request + MSD_ID_HD_VALVES_POSITION_COUNT_OVERRIDE = 0x8058, ///< HD valves position counts override request MSG_ID_HD_SYRINGE_PUMP_STATUS_OVERRIDE = 0x8059, ///< HD syringe pump status override request MSG_ID_HD_SYRINGE_PUMP_ENCODER_STATUS_OVERRIDE = 0x805A, ///< HD syringe pump encoder status override request MSG_ID_HD_SYRINGE_PUMP_ADC_DAC_STATUS_OVERRIDE = 0x805B, ///< HD syringe pump ADC and DAC status override request @@ -286,7 +289,7 @@ MSG_ID___AVAILABLE_13 = 0xA01E, ///< This msg ID is available for use MSG_ID___AVAILABLE_14 = 0xA01F, ///< This msg ID is available for use MSG_ID___AVAILABLE_15 = 0xA020, ///< This msg ID is available for use - MSG_ID_HEAT_DISINFECT_PUBLISH_INTERVAL_OVERRIDE = 0xA021, ///< Heat disinfection data publish interval override request + MSG_ID___AVAILABLE_16 = 0xA021, ///< This msg ID is available for use MSG_ID_DG_SOFTWARE_RESET_REQUEST = 0xA022, ///< DG reset request MSG_ID_DG_CONCENTRATE_PUMP_MEASURED_SPEED_OVERRIDE = 0xA023, ///< DG concentrate pump measured speed override request MSG_ID_CONCENTRATE_PUMP_TARGET_SPEED_OVERRIDE = 0xA024, ///< Concentrate pumps' target speed override request