Index: MsgDefs.h =================================================================== diff -u -rab31e00d2dcd65b55b1934d7178fcd1e20be56e4 -r5240dd31524f1c2aecb60013a3c5e117898eb746 --- MsgDefs.h (.../MsgDefs.h) (revision ab31e00d2dcd65b55b1934d7178fcd1e20be56e4) +++ MsgDefs.h (.../MsgDefs.h) (revision 5240dd31524f1c2aecb60013a3c5e117898eb746) @@ -86,12 +86,11 @@ MSG_ID_DG_HEAT_DISINFECT_DATA = 0x37, ///< DG heat disinfection publish data MSG_ID_UI_START_TREATMENT = 0x38, ///< UI user request to initiate a treatment MSG_ID_HD_START_TREATMENT_RESPONSE = 0x39, ///< HD response to user request to initiate a treatment - MSG_ID_HD_VALVES_DATA = 0x3A, ///< HD broadcast of valves + MSG_ID_HD_VALVES_DATA = 0x3A, ///< HD broadcast of valves data MSG_ID_UI_USER_CONFIRM_TREATMENT_PARAMS = 0x3B, ///< UI user confirmation of treatment parameters MSG_ID_UI_TREATMENT_END_REQUEST = 0x3C, ///< UI user treatment end request MSG_ID_HD_TREATMENT_END_RESPONSE = 0x3D, ///< HD response to user request to end treatment - - MSG_ID_TEMP_FAST_HD_VALVES_REMOVE_LATER = 0x6D, ///< TODO REMOVE FOR FAST TESING ONLY + MSG_ID_HD_AIR_TRAP_DATA = 0x3E, ///< HD broadcase of air trap data #ifdef EMC_TEST_BUILD MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing #endif @@ -147,8 +146,11 @@ MSG_ID_HD_SET_PARAMETER_TREATMENT_PARAMETER = 0x802D, ///< Set a treatment parameter (will change actual setting, not an override) MSG_ID_HD_VALVES_HOME = 0x802E, ///< Home an HD Valve MSG_ID_HD_VALVES_POSITION_OVERRIDE = 0x802F, ///< Set an HD valve to a position in counts - MSG_ID_HD_VALVES_SET_AIR_TRAP_VALVE = 0x8030, ///< Set the HD blood trap valve status + MSG_ID_HD_VALVES_SET_AIR_TRAP_VALVE = 0x8030, ///< Set the HD blood trap valve status MSG_ID_HD_VALVES_SET_PWM_OVERRIDE = 0x8031, ///< Set an HD valve PWM + MSG_ID_HD_AIR_TRAP_SEND_INTERVAL_OVERRIDE = 0x8032, ///< HD air trap data broadcast interval override request + MSG_ID_HD_AIR_TRAP_LEVEL_SENSOR_OVERRIDE = 0x8033, ///< HD air trap level sensor override request + MSG_ID_HD_SOFTWARE_RESET_REQUEST = 0x8034, ///< HD reset request MSG_ID_FIRST_DG_TESTER_MESSAGE = 0xA000, ///< First DG test message ID MSG_ID_DG_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DG_TESTER_MESSAGE, ///< DG tester log-in @@ -184,6 +186,7 @@ MSG_ID_HEAT_DISINFECT_R2_TO_R1_DURATION_MINS = 0xA01F, ///< Heat disinfection reservoir 2 to reservoir 1 duration in minutes MSG_ID_HEAT_DISINFECT_NO_OF_CYCLES_TO_RUN = 0xA020, ///< Heat disinfection number of cycles to run MSG_ID_HEAT_DISINFECT_PUBLISH_INTERVAL_OVERRIDE = 0xA021, ///< Heat disinfection data publish interval override request + MSG_ID_DG_SOFTWARE_RESET_REQUEST = 0xA022, ///< DG reset request MSG_ID_HD_DEBUG_EVENT = 0xFFF1, ///< HD debug event text to be logged in event log MSG_ID_DG_DEBUG_EVENT = 0xFFF2, ///< DG debug event text to be logged in event log