Index: MsgDefs.h =================================================================== diff -u -rb8639f4c96d887dd3ee24498a9f65604b7ac51b6 -r77ddb0b055467c2be91df660d8dbd81870d25663 --- MsgDefs.h (.../MsgDefs.h) (revision b8639f4c96d887dd3ee24498a9f65604b7ac51b6) +++ MsgDefs.h (.../MsgDefs.h) (revision 77ddb0b055467c2be91df660d8dbd81870d25663) @@ -8,8 +8,8 @@ * * @file MsgDefs.h * -* @author (last) Dara Navaei -* @date (last) 03-Feb-2023 +* @author (last) Michael Garthwaite +* @date (last) 09-Mar-2023 * * @author (original) Sean * @date (original) 27-Feb-2020 @@ -30,70 +30,70 @@ enum Msg_IDs { // normal CAN messages MSG_ID_UNUSED = 0x0, ///< Zero is an undefined (un-used) message ID) - MSG_ID_OFF_BUTTON_PRESS = 0x1, ///< HD/UI off button interactions - MSG_ID_ALARM_STATUS = 0x2, ///< HD broadcast of system alarm state information + MSG_ID_OFF_BUTTON_PRESS_REQUEST = 0x1, ///< UI to HD off button request + MSG_ID_ALARM_STATUS_DATA = 0x2, ///< HD broadcast of system alarm state information MSG_ID_ALARM_TRIGGERED = 0x3, ///< Alarm triggered event MSG_ID_ALARM_CLEARED = 0x4, ///< Alarm cleared event MSG_ID_BLOOD_FLOW_DATA = 0x5, ///< HD broadcast of blood flow/pump data - MSG_ID_DG_CHECK_IN = 0x6, ///< DG check-in with HD + AVAILABLE_1 = 0x6, ///< Unused MSG_ID MSG_ID_UI_CHECK_IN = 0x7, ///< UI check-in with HD MSG_ID_DIALYSATE_FLOW_DATA = 0x8, ///< HD broadcast of dialysate inlet flow/pump data MSG_ID_PRESSURE_OCCLUSION_DATA = 0x9, ///< HD broadcast of pressure/occlusion data - MSG_ID_RTC_EPOCH = 0xA, ///< HD broadcast of current date and time from clock + MSG_ID_RTC_EPOCH_DATA = 0xA, ///< HD broadcast of current date and time from clock MSG_ID_DIALYSATE_OUT_FLOW_DATA = 0xB, ///< HD broadcast of dialysate outlet flow/pump/load cell data - MSG_ID_LOAD_CELL_READINGS = 0xC, ///< DG broadcast of load cell weights - MSG_ID_TREATMENT_TIME = 0xD, ///< HD broadcast of treatment time + MSG_ID_LOAD_CELL_READINGS_DATA = 0xC, ///< DG broadcast of load cell weights + MSG_ID_TREATMENT_TIME_DATA = 0xD, ///< HD broadcast of treatment time MSG_ID_POWER_OFF_WARNING = 0xE, ///< HD broadcast power off warning - system power down is imminent - MSG_ID_TREATMENT_STATE = 0xF, ///< HD broadcast of treatment state + MSG_ID_TREATMENT_STATE_DATA = 0xF, ///< HD broadcast of treatment state MSG_ID_USER_UF_PAUSE_RESUME_REQUEST = 0x10, ///< User request to pause or resume ultrafiltration MSG_ID_USER_UF_SETTINGS_CHANGE_REQUEST = 0x11, ///< User request to change ultrafiltration settings MSG_ID_USER_SALINE_BOLUS_REQUEST = 0x12, ///< User request for a saline bolus MSG_ID_USER_UF_SETTINGS_CHANGE_RESPONSE = 0x13, ///< HD response to user request to change ultrafiltration settings MSG_ID_USER_SALINE_BOLUS_RESPONSE = 0x14, ///< HD response to user saline bolus request - MSG_ID_USER_CONFIRM_UF_SETTINGS_CHANGE = 0x15, ///< User confirmation of ultrafiltration settings change + MSG_ID_USER_CONFIRM_UF_SETTINGS_CHANGE_REQUEST = 0x15, ///< User confirmation of ultrafiltration settings change MSG_ID_USER_TREATMENT_TIME_CHANGE_REQUEST = 0x16, ///< User request to change treatment duration MSG_ID_USER_BLOOD_DIAL_RATE_CHANGE_REQUEST = 0x17, ///< User request to change blood and dialysate rates MSG_ID_USER_BLOOD_DIAL_RATE_CHANGE_RESPONSE = 0x18, ///< HD response to user request to change blood and dialysate rates MSG_ID_SET_DG_DIALYSATE_TEMP_TARGETS = 0x19, ///< HD provides DG with dialysate temperature set points - MSG_ID_TREATMENT_PARAM_CHANGE_RANGES = 0x1A, ///< HD provides several parameter change ranges as they evolve over treatment duration + MSG_ID_TREATMENT_PARAM_CHANGE_RANGES_DATA = 0x1A, ///< HD provides several parameter change ranges as they evolve over treatment duration MSG_ID_USER_TREATMENT_TIME_CHANGE_RESPONSE = 0x1B, ///< HD response to user request to change treatment duration - MSG_ID_REQUEST_FW_VERSIONS = 0x1C, ///< UI request for f/w versions - MSG_ID_HD_VERSION = 0x1D, ///< HD f/w version - MSG_ID_DG_VERSION = 0x1E, ///< DG f/w version + MSG_ID_FW_VERSIONS_REQUEST = 0x1C, ///< UI request for f/w versions + MSG_ID_HD_VERSION_REPONSE = 0x1D, ///< HD f/w version response + MSG_ID_DG_VERSION_REPONSE = 0x1E, ///< DG f/w version response MSG_ID_RO_PUMP_DATA = 0x1F, ///< DG broadcast of RO pump data MSG_ID_DG_PRESSURES_DATA = 0x20, ///< DG broadcast of pressure sensors data - MSG_ID_DG_SWITCH_RESERVOIR_CMD = 0x21, ///< HD request to DG to switch reservoirs (A->B or B->A) - MSG_ID_DG_FILL_CMD = 0x22, ///< HD request to DG to fill inactive reservoir - MSG_ID_DG_DRAIN_CMD = 0x23, ///< HD request to DG to drain inactive reservoir + MSG_ID_DG_SWITCH_RESERVOIR_CMD_REQUEST = 0x21, ///< HD request to DG to switch reservoirs (A->B or B->A) + MSG_ID_DG_FILL_CMD_REQUEST = 0x22, ///< HD request to DG to fill inactive reservoir + MSG_ID_DG_DRAIN_CMD_REQUEST = 0x23, ///< HD request to DG to drain inactive reservoir MSG_ID_DRAIN_PUMP_DATA = 0x24, ///< DG broadcast of drain pump data - MSG_ID_HD_OP_MODE = 0x25, ///< HD broadcast current operating mode - MSG_ID_STARTING_STOPPING_TREATMENT_CMD = 0x26, ///< HD request to DG to move in/out of standby mode due to treatment start/stop - MSG_ID_DG_OP_MODE = 0x27, ///< DG broadcast current operating mode + MSG_ID_HD_OP_MODE_DATA = 0x25, ///< HD broadcast current operating mode + MSG_ID_STARTING_STOPPING_TREATMENT_CMD_REQUEST = 0x26, ///< HD request to DG to move in/out of standby mode due to treatment start/stop + MSG_ID_DG_OP_MODE_DATA = 0x27, ///< DG broadcast current operating mode MSG_ID_DG_RESERVOIRS_DATA = 0x28, ///< DG broadcast reservoirs data - MSG_ID_DG_SAMPLE_WATER_CMD = 0x29, ///< HD request to DG to allow user to get a water sample - MSG_ID_DG_VALVES_STATES = 0x2A, ///< DG broadcast valve states - MSG_ID_HD_START_STOP_TRIMMER_HEATER_CMD = 0x2B, ///< HD request to DG to start/stop trimmer heater + MSG_ID_DG_SAMPLE_WATER_CMD_REQUEST = 0x29, ///< HD request to DG to allow user to get a water sample + MSG_ID_DG_VALVES_STATES_DATA = 0x2A, ///< DG broadcast valve states + MSG_ID_HD_START_STOP_TRIMMER_HEATER_CMD_REQUEST = 0x2B, ///< HD request to DG to start/stop trimmer heater MSG_ID_DG_HEATERS_DATA = 0x2C, ///< DG broadcast of the heaters data MSG_ID_DG_TEMPERATURE_DATA = 0x2D, ///< DG broadcast of the temperature sensors data MSG_ID_USER_UF_SETTINGS_CHANGE_CONFIRMATION_RESPONSE = 0x2E, ///< HD response to user selection of ultrafiltration settings change option selection MSG_ID_SALINE_BOLUS_DATA = 0x2F, ///< HD broadcast of saline bolus data - MSG_ID_DG_START_STOP_HEAT_DISINFECT = 0x30, ///< HD request to start or stop DG heat disinfection + MSG_ID_DG_START_STOP_HEAT_DISINFECT_CMD_REQUEST = 0x30, ///< HD request to start or stop DG heat disinfection MSG_ID_DG_CONDUCTIVITY_DATA = 0x31, ///< DG broadcast of the conductivity sensors data - MSG_ID_USER_REQUEST_ALARM_SILENCE = 0x32, ///< UI request alarm silence (or cancel) + MSG_ID_USER_ALARM_SILENCE_REQUEST = 0x32, ///< UI request alarm silence (or cancel) MSG_ID_HD_ACCELEROMETER_DATA = 0x33, ///< HD broadcast of accelerometer data MSG_ID_DG_ACCELEROMETER_DATA = 0x34, ///< DG broadcast of accelerometer data - MSG_ID_UI_NEW_TREATMENT_PARAMS = 0x35, ///< UI request to validate new treatment parameter set + MSG_ID_UI_NEW_TREATMENT_PARAMS_REQUEST = 0x35, ///< UI request to validate new treatment parameter set MSG_ID_HD_NEW_TREATMENT_PARAMS_RESPONSE = 0x36, ///< HD response to new treatment parameters set MSG_ID_DG_HEAT_DISINFECT_DATA = 0x37, ///< DG heat disinfect publish data MSG_ID_UI_INITIATE_TREATMENT_REQUEST = 0x38, ///< UI user request to initiate a treatment MSG_ID_HD_INITIATE_TREATMENT_RESPONSE = 0x39, ///< HD response to user request to initiate a treatment MSG_ID_HD_VALVES_DATA = 0x3A, ///< HD broadcast of valves data - MSG_ID_UI_USER_CONFIRM_TREATMENT_PARAMS = 0x3B, ///< UI user confirmation of treatment parameters + MSG_ID_UI_USER_CONFIRM_TREATMENT_PARAMS_REQUEST = 0x3B, ///< UI user confirmation of treatment parameters MSG_ID_UI_START_PRIME_REQUEST = 0x3C, ///< UI user has requested to start priming MSG_ID_HD_START_PRIME_RESPONSE = 0x3D, ///< HD response to user request to start priming MSG_ID_HD_AIR_TRAP_DATA = 0x3E, ///< HD broadcast of air trap data MSG_ID_ALARM_CONDITION_CLEARED = 0x3F, ///< Alarm condition cleared event - MSG_ID_UI_ALARM_USER_ACTION = 0x40, ///< UI user has requested an alarm action + MSG_ID_UI_ALARM_USER_ACTION_REQUEST = 0x40, ///< UI user has requested an alarm action MSG_ID_USER_UF_PAUSE_RESUME_RESPONSE = 0x41, ///< HD response to user request to pause or resume ultrafiltration MSG_ID_DG_CONCENTRATE_PUMP_DATA = 0x42, ///< DG broadcast of concentrate pump data MSG_ID_HD_PRIMING_STATUS_DATA = 0x43, ///< HD priming status during cartridge prime @@ -103,70 +103,70 @@ MSG_ID_HD_PRESSURE_LIMITS_CHANGE_RESPONSE = 0x47, ///< HD response to change pressure limits request MSG_ID_DG_FANS_DATA = 0x48, ///< DG broadcast fans data MSG_ID_HD_TREATMENT_STOP_TIMER_DATA = 0x49, ///< HD broadcast of treatment stop timer (countdown to treatment stop - no rinseback alarm) - MSG_ID_UI_PATIENT_DISCONNECTION_CONFIRM = 0x4A, ///< UI patient disconnection confirm + MSG_ID_UI_PATIENT_DISCONNECTION_CONFIRM_REQUEST = 0x4A, ///< UI patient disconnection confirm MSG_ID_UI_HEPARIN_PAUSE_RESUME_REQUEST = 0x4B, ///< UI request to pause/resume Heparin delivery MSG_ID_HD_HEPARIN_PAUSE_RESUME_RESPONSE = 0x4C, ///< HD response to pause/resume Heparing delivery request - MSG_ID_HD_HEPARIN_DATA_BROADCAST = 0x4D, ///< HD broadcast of Heparin delivery data - MSG_ID_UI_SET_ALARM_AUDIO_VOLUME_LEVEL_CMD = 0x4E, ///< UI command to set alarm audio volume level - MSG_ID_UI_SET_UF_VOLUME_PARAMETER = 0x4F, ///< UI request to validate new ultrafiltration volume treatment parameter + MSG_ID_HD_HEPARIN_DATA = 0x4D, ///< HD broadcast of Heparin delivery data + MSG_ID_UI_SET_ALARM_AUDIO_VOLUME_LEVEL_CMD_REQUEST = 0x4E, ///< UI command to set alarm audio volume level + MSG_ID_UI_SET_UF_VOLUME_PARAMETER_REQUEST = 0x4F, ///< UI request to validate new ultrafiltration volume treatment parameter MSG_ID_HD_SET_UF_VOLUME_PARAMETER_RESPONSE = 0x50, ///< HD response to new treatment parameters set MSG_ID_DG_COMMAND_RESPONSE = 0x51, ///< DG response to command from HD - MSG_ID_UI_RINSEBACK_CMD = 0x52, ///< UI rinseback sub-mode user request + MSG_ID_UI_RINSEBACK_CMD_REQUEST = 0x52, ///< UI rinseback sub-mode user request MSG_ID_HD_RINSEBACK_CMD_RESPONSE = 0x53, ///< HD rinseback sub-mode user request response - MSG_ID_UI_RECIRC_CMD = 0x54, ///< UI re-circ sub-mode user request + MSG_ID_UI_RECIRC_CMD_REQUEST = 0x54, ///< UI re-circ sub-mode user request MSG_ID_HD_RECIRC_CMD_RESPONSE = 0x55, ///< HD re-circ sub-mode request response MSG_ID_HD_RINSEBACK_PROGRESS = 0x56, ///< HD broadcast of rinseback progress - MSG_ID_UI_TX_END_CMD = 0x57, ///< UI end treatment sub-mode user request + MSG_ID_UI_TX_END_CMD_REQUEST = 0x57, ///< UI end treatment sub-mode user request MSG_ID_HD_TX_END_CMD_RESPONSE = 0x58, ///< HD end treatment sub-mode user request response - MSG_ID_HD_BLOOD_PRIME_PROGRESS = 0x59, ///< HD broadcast of blood prime progress - MSG_ID_HD_RECIRC_PROGRESS = 0x5A, ///< HD broadcast of treatment re-circulate progress - MSG_ID_DG_CHANGE_VALVE_SETTING_CMD = 0x5B, ///< HD request to DG to change valve setting - MSG_ID_PRE_TREATMENT_STATE = 0x5C, ///< HD broadcast of pre-treatment state - MSG_ID_UI_SAMPLE_WATER_CMD = 0x5D, ///< UI sample water sub-mode user request + MSG_ID_HD_BLOOD_PRIME_PROGRESS_DATA = 0x59, ///< HD broadcast of blood prime progress + MSG_ID_HD_RECIRC_PROGRESS_DATA = 0x5A, ///< HD broadcast of treatment re-circulate progress + MSG_ID_DG_CHANGE_VALVE_SETTING_CMD_REQUEST = 0x5B, ///< HD request to DG to change valve setting + MSG_ID_PRE_TREATMENT_STATE_DATA = 0x5C, ///< HD broadcast of pre-treatment state + MSG_ID_UI_SAMPLE_WATER_CMD_REQUEST = 0x5D, ///< UI sample water sub-mode user request MSG_ID_HD_SAMPLE_WATER_CMD_RESPONSE = 0x5E, ///< HD sample water sub-mode request response MSG_ID_UI_SAMPLE_WATER_RESULT = 0x5F, ///< UI sample water result message - MSG_ID_DG_FILTER_FLUSH_PROGRESS = 0x60, ///< DG broadcast of filter flush progress - MSG_ID_HD_NO_CART_SELF_TEST_PROGRESS = 0x61, ///< HD broadcast of no cartridge self-tests progress - MSG_ID_UI_INSTALLATION_CONFIRM = 0x62, ///< UI disposable installation user confirmation - MSG_ID_HD_DRY_SELF_TEST_PROGRESS = 0x63, ///< HD broadcast of dry self-tests progress + MSG_ID_DG_FILTER_FLUSH_PROGRESS_DATA = 0x60, ///< DG broadcast of filter flush progress + MSG_ID_HD_NO_CART_SELF_TEST_PROGRESS_DATA = 0x61, ///< HD broadcast of no cartridge self-tests progress + MSG_ID_UI_INSTALLATION_CONFIRM_REQUEST = 0x62, ///< UI disposable installation user confirmation + MSG_ID_HD_DRY_SELF_TEST_PROGRESS_DATA = 0x63, ///< HD broadcast of dry self-tests progress MSG_ID_UI_PATIENT_CONNECTION_BEGIN_REQUEST = 0x64, ///< UI user has requested to begin patient connection MSG_ID_HD_PATIENT_CONNECTION_BEGIN_RESPONSE = 0x65, ///< HD response to user request to begin patient connection - MSG_ID_UI_PATIENT_CONNECTION_CONFIRM = 0x66, ///< UI user has confirmed patient connection completed + MSG_ID_UI_PATIENT_CONNECTION_CONFIRM_REQUEST = 0x66, ///< UI user has confirmed patient connection completed MSG_ID_HD_PATIENT_CONNECTION_CONFIRM_RESPONSE = 0x67, ///< HD response to user confirmation of patient connection - MSG_ID_UI_CONSUMABLE_INSTALL_CONFIRM = 0x68, ///< UI user has confirmed consumable install + MSG_ID_UI_CONSUMABLE_INSTALL_CONFIRM_REQUEST = 0x68, ///< UI user has confirmed consumable install MSG_ID_HD_SYRINGE_PUMP_DATA = 0x69, ///< HD broadcast of syringe pump data - MSG_ID_HD_FLUID_LEAK_STATE = 0x6A, ///< HD broadcast of fluid leak state - MSG_ID_DG_FLUID_LEAK_STATE = 0x6B, ///< DG broadcast of fluid leak state + MSG_ID_HD_FLUID_LEAK_STATE_DATA = 0x6A, ///< HD broadcast of fluid leak state + MSG_ID_DG_FLUID_LEAK_STATE_DATA = 0x6B, ///< DG broadcast of fluid leak state MSG_ID_HD_BLOOD_LEAK_DATA = 0x6C, ///< HD broadcast of blood leak data MSG_ID_UI_HD_SET_RTC_REQUEST = 0x6D, ///< UI requests HD to set RTC MSG_ID_HD_UI_SET_RTC_RESPONSE = 0x6E, ///< HD response for RTC set request MSG_ID_UI_DG_SET_RTC_REQUEST = 0x6F, ///< UI requests DG to set RTC MSG_ID_DG_UI_SET_RTC_RESPONSE = 0x70, ///< DG response for RTC set request MSG_ID_UI_START_TREATMENT_REQUEST = 0x71, ///< UI user has requested to start treatment MSG_ID_HD_START_TREATMENT_RESPONSE = 0x72, ///< HD response to user request to start treatment - MSG_ID_UI_DISPOSABLE_REMOVAL_CONFIRM = 0x73, ///< UI user has confirmed disposable removal + MSG_ID_UI_DISPOSABLE_REMOVAL_CONFIRM_REQUEST = 0x73, ///< UI user has confirmed disposable removal MSG_ID_HD_DISPOSABLE_REMOVAL_CONFIRM_RESPONSE = 0x74, ///< HD response to user confirmation of disposable removal MSG_ID_UI_TREATMENT_LOG_DATA_REQUEST = 0x75, ///< UI request treatment log data message MSG_ID_HD_TREATMENT_LOG_DATA_RESPONSE = 0x76, ///< HD response to UI treatment log data request - MSG_ID_HD_POST_TREATMENT_STATE = 0x77, ///< HD broadcast of post-treatment state + MSG_ID_HD_POST_TREATMENT_STATE_DATA = 0x77, ///< HD broadcast of post-treatment state MSG_ID_DG_START_STOP_CHEM_DISINFECT = 0x78, ///< DG start/stop chemical disinfection - MSG_ID_DG_START_STOP_FLUSH = 0x79, ///< DG start/stop flush mode + MSG_ID_DG_START_STOP_FLUSH_CMD_REQUEST = 0x79, ///< DG start/stop flush mode MSG_ID_DG_FLUSH_DATA = 0x7A, ///< DG flush data publish MSG_ID_HD_VOLTAGES_DATA = 0x7B, ///< HD voltages data publish MSG_ID_HD_ALARM_AUDIO_VOLUME_SET_RESPONSE = 0x7C, ///< HD response to UI set alarm audio volume request - MSG_ID_HD_ALARM_INFORMATION = 0x7D, ///< HD alarm information broadcast message + MSG_ID_HD_ALARM_INFORMATION_DATA = 0x7D, ///< HD alarm information broadcast message MSG_ID_HD_DISINFECT_STANDBY_DATA = 0x7E, ///< HD broadcast of standby disinfect data MSG_ID_UI_DISINFECT_REQUEST = 0x7F, ///< UI disinfection selection MSG_ID_HD_DISINFECT_RESPONSE = 0x80, ///< HD response to disinfection selection - MSG_ID_UI_CHEM_DISINFECT_CONFIRM = 0x81, ///< UI confirmation of chemical disinfection start + MSG_ID_UI_CHEM_DISINFECT_CONFIRM_REQUEST = 0x81, ///< UI confirmation of chemical disinfection start MSG_ID_HD_CHEM_DISINFECT_CONFIRM_RESPONSE = 0x82, ///< HD response to confirmation of chemical disinfection start MSG_ID_DG_FLUSH_TIME_DATA = 0x83, ///< DG broadcast of flush mode time data MSG_ID_DG_HEAT_DISINFECT_TIME_DATA = 0x84, ///< DG broadcast of heat disinfection mode time data MSG_ID_DG_CHEM_DISINFECT_TIME_DATA = 0x85, ///< DG broadcast of chemical disinfection mode time data MSG_ID_DG_VOLTAGES_DATA = 0x86, ///< DG voltages data publish MSG_ID_DG_CHEM_DISINFECT_DATA = 0x87, ///< DG chemical disinfect data publish - MSG_ID_DG_SERIAL_NUMBER = 0x88, ///< DG serial number - MSG_ID_UI_REQUEST_SERVICE_INFO = 0x89, ///< UI request for service schedule information + MSG_ID_DG_SERIAL_NUMBER_RESPONSE = 0x88, ///< DG serial number + MSG_ID_UI_SERVICE_INFO_REQUEST = 0x89, ///< UI request for service schedule information MSG_ID_HD_SERVICE_SCHEDULE_DATA = 0x8A, ///< HD service schedule data MSG_ID_HD_USAGE_DATA = 0x8B, ///< HD usage data MSG_ID_DG_SERVICE_SCHEDULE_DATA = 0x8C, ///< DG service schedule data @@ -182,53 +182,54 @@ MSG_ID_HD_TREATMENT_LOG_EVENT = 0x96, ///< HD treatment log event MSG_ID_UI_ACTIVE_ALARMS_LIST_REQUEST = 0x97, ///< UI active alarms list request MSG_ID_HD_ACTIVE_ALARMS_LIST_REQUEST_RESPONSE = 0x98, ///< HD active alarms list request response - MSG_ID_HD_SERIAL_NUMBER = 0x99, ///< HD serial number + MSG_ID_HD_SERIAL_NUMBER_RESPONSE = 0x99, ///< HD serial number MSG_ID_HD_SET_STANDBY_DISINFECT_SUB_MODE_REQUEST = 0x9A, ///< HD set standby disinfect submode request MSG_ID_HD_SET_STANDBY_DISINFECT_SUB_MODE_RESPONSE = 0x9B, ///< HD set standby disinfect submode response MSG_ID_HD_DG_POST_RESULT_REQUEST = 0x9C, ///< HD request for DG POST final result (reported back on msg 0x91) MSG_ID_HD_TEMPERATURES_DATA = 0x9D, ///< HD temperatures data MSG_ID_HD_UI_VERSION_INFO_REQUEST = 0x9E, ///< HD request for UI version information - MSG_ID_HD_UI_VERSION_INFO_RESPONSE = 0x9F, ///< UI response to HD request for version information - MSG_ID_REQUEST_HD_USAGE_INFO = 0xA0, ///< HD request usage information + MSG_ID_UI_VERSION_INFO_RESPONSE = 0x9F, ///< UI response to HD request for version information + MSG_ID_HD_USAGE_INFO_REQUEST = 0xA0, ///< HD request usage information MSG_ID_DG_SWITCHES_DATA = 0xA1, ///< DG switches data publish MSG_ID_HD_SWITCHES_DATA = 0xA2, ///< HD switches data publish MSG_ID_HD_FANS_DATA = 0xA3, ///< HD fans data publish MSG_ID_HD_EVENT = 0xA4, ///< HD general event MSG_ID_DG_EVENT = 0xA5, ///< DG general event - MSG_ID_HD_SET_SERVICE_TIME = 0xA6, ///< HD set service time - MSG_ID_DG_ALARM_INFO = 0xA7, ///< DG alarm information data publish + MSG_ID_HD_SET_SERVICE_TIME_REQUEST = 0xA6, ///< HD set service time + MSG_ID_DG_ALARM_INFO_DATA = 0xA7, ///< DG alarm information data publish MSG_ID_HD_RESERVOIRS_DATA = 0xA8, ///< HD reservoirs data publish - MSG_ID_HD_REQUEST_DG_CONCENTRATE_MIXING_RATIOS = 0xA9, ///< HD request DG concentrate ratios + MSG_ID_HD_DG_CONCENTRATE_MIXING_RATIOS_REQUEST = 0xA9, ///< HD request DG concentrate ratios MSG_ID_DG_CONCENTRATE_MIXING_RATIOS_DATA = 0xAA, ///< DG concentrate mixing ratios data MSG_ID_DG_SCHEDULED_RUNS_DATA = 0xAB, ///< DG scheduled runs data - MSG_ID_DG_SET_SERVICE_TIME = 0xAC, ///< DG set service time + MSG_ID_DG_SET_SERVICE_TIME_REQUEST = 0xAC, ///< DG set service time MSG_ID_UI_INSTALLATION_CONFIRM_RESPONSE = 0xAD, ///< HD Confirm installation response MSG_ID_DG_FILL_MODE_DATA = 0xAE, ///< DG broadcast of fill mode data such as used acid & bicarb volume MSG_ID_DG_GEN_IDLE_DATA = 0xAF, ///< DG broadcast of Gen idle mode sub-state - MSG_ID_UI_REQUEST_SERVICE_MODE = 0xB0, ///< UI request to HD to go to service mode + MSG_ID_UI_SERVICE_MODE_REQUEST = 0xB0, ///< UI request to HD to go to service mode MSG_ID_HD_RESPONSE_SERVICE_MODE_REQUEST = 0xB1, ///< HD response to UI request to go to service mode MSG_ID_HD_REQUEST_UI_FINAL_POST_RESULT = 0xB2, ///< HD request to UI for final POST result MSG_ID_DG_FLOW_SENSORS_DATA = 0xB3, ///< DG flow sensors data publish MSG_ID_DG_RESPONSE_SERVICE_MODE_REQUEST = 0xB4, ///< DG response to HD request to go to service mode - MSG_ID_HD_REQUEST_DG_ALARMS = 0xB5, ///< HD request for DG to re-send trigger messages for each active alarm - MSG_ID_HD_REQUEST_DG_SERVICE_MODE = 0xB6, ///< HD request for DG to to go to service mode - MSG_ID_DG_RTC_EPOCH = 0xB7, ///< DG RTC epoch broadcast message - MSG_ID_HD_REQUEST_DG_USAGE_INFO = 0xB8, ///< HD request DG usage info - MSG_ID_HD_REQUEST_DG_SERVICE_RECORD = 0xB9, ///< HD request DG service record - MSG_ID_HD_REQUEST_UI_CONFIRMATION = 0xBA, ///< HD request UI confirmation - MSG_ID_UI_CONFIRMATION_RESULT = 0xBB, ///< UI confirmation result response - MSG_ID_REQUEST_CPLD_STATUS = 0xBC, ///< Dialin request for CPLD Status - MSG_ID_DG_CPLD_STATUS = 0xBD, ///< DG CPLD Status + MSG_ID_HD_DG_ALARMS_REQUEST = 0xB5, ///< HD request for DG to re-send trigger messages for each active alarm + MSG_ID_HD_DG_SERVICE_MODE_REQUEST = 0xB6, ///< HD request for DG to to go to service mode + MSG_ID_DG_RTC_EPOCH_DATA = 0xB7, ///< DG RTC epoch broadcast message + MSG_ID_HD_DG_USAGE_INFO_REQUEST = 0xB8, ///< HD request DG usage info + MSG_ID_HD_DG_SERVICE_RECORD_REQUEST = 0xB9, ///< HD request DG service record + MSG_ID_HD_UI_CONFIRMATION_REQUEST = 0xBA, ///< HD request UI confirmation + MSG_ID_UI_CONFIRMATION_RESULT_RESPONSE = 0xBB, ///< UI confirmation result response + MSG_ID_CPLD_STATUS_REQUEST = 0xBC, ///< Dialin request for CPLD Status + MSG_ID_DG_CPLD_STATUS_DATA = 0xBD, ///< DG CPLD Status MSG_ID_HD_BATTERY_MANAGEMENT_DATA = 0xBE, ///< HD battery management logging data MSG_ID_HD_BATTERY_STATUS_DATA = 0xBF, ///< HD battery status logging data MSG_ID_DG_CHEM_DISINFECT_FLUSH_DATA = 0xC0, ///< DG chemical disinfect flush logging data MSG_ID_DG_CHEM_DISINFECT_FLUSH_TIME_DATA = 0xC1, ///< DG broadcast of chemical disinfect flush mode time data MSG_ID_DG_START_STOP_CHEM_DISINFECT_FLUSH = 0xC2, ///< DG start/stop chemical disinfect flush - MSG_ID_UI_CHEM_DISINFECT_FLUSH_CONFIRM = 0xC3, ///< UI confirmation of chemical disinfect flush start + MSG_ID_UI_CHEM_DISINFECT_FLUSH_CONFIRM_REQUEST = 0xC3, ///< UI confirmation of chemical disinfect flush start MSG_ID_HD_CHEM_DISINFECT_FLUSH_CONFIRM_RESPONSE = 0xC4, ///< HD response to confirmation of chemical disinfect flush start MSG_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_DATA = 0xC5, ///< DG heat disinfect active cool data broadcast MSG_ID_DG_START_STOP_HEAT_DISINFECT_ACTIVE_COOL = 0xC6, ///< DG heat disinfect active cool start/stop command MSG_ID_HD_AIR_PUMP_DATA = 0xC7, ///< HD air pump data publish + MSG_ID_HD_SEND_CHEM_FLUSH_SAMPLE_PASS_FAIL_TO_DG = 0xC8, ///< HD send chemical disinfect flush sample pass/fail to DG #ifdef EMC_TEST_BUILD MSG_ID_CAN_ERROR_COUNT = 0x999, // test code in support of EMC testing @@ -459,7 +460,7 @@ MSG_ID_DG_USED_ACID_VOLUME_ML_OVERRIDE = 0xA04E, ///< DG used acid volume override in mL MSG_ID_DG_SET_FANS_RPM_ALARM_START_TIME_OFFSET = 0xA04F, ///< DG set fans RPM alarm start time offset MSG_ID_DG_USED_BICARB_VOLUME_ML_OVERRIDE = 0xA050, ///< DG used bicarb volume override in mL - MSG_ID_FILL_MODE_DATA_PUBLISH_INTERVAL_OVERRIDE = 0xA051, ///< DG used concentrate publish interval override request + MSG_ID_FILL_MODE_DATA_PUBLISH_INTERVAL_OVERRIDE = 0xA051, ///< DG used fill publish interval override request MSG_ID_DG_GEN_IDLE_PUBLISH_INTERVAL_OVERRIDE = 0xA052, ///< DG gen idle sub-states publish interval override request MSG_ID_DG_GET_USAGE_INFO_RECORD = 0xA053, ///< DG get usage information record MSG_ID_DG_SET_USAGE_INFO_RECORD = 0xA054, ///< DG set usage information record @@ -479,6 +480,7 @@ MSD_ID_DG_RTC_CTL_REG1_STATUS_OVERRIDE = 0xA062, ///< DG RTC control register 1 status override MSD_ID_DG_RTC_CTL_REG3_STATUS_OVERRIDE = 0xA063, ///< DG RTC control register 3 status override MSG_ID_DG_NELSON_DISINFECT_SUPPORT = 0xA064, ///< DG Nelson labs disinfect support message + MSG_ID_DG_SET_DIALYSATE_MIXING_RATIOS = 0xA065, ///< DG set dialysate mixing ratios MSG_ID_HD_DEBUG_EVENT = 0xFFF1, ///< HD debug event text to be logged in event log MSG_ID_DG_DEBUG_EVENT = 0xFFF2, ///< DG debug event text to be logged in event log @@ -544,6 +546,7 @@ REQUEST_REJECT_REASON_DG_CHEM_FLUSH_NOT_COMPLETED = 49, ///< DG chemical flush is not complete REQUEST_REJECT_REASON_DG_RO_FILTER_TEMPERATURE_OUT_OF_RANGE = 50, ///< DG RO filter temperature out of range REQUEST_REJECT_REASON_DG_INCOMPATIBLE = 51, ///< DG firmware version is not compatible with HD firmware + REQUEST_REJECT_REASON_HEPARIN_PRESTOP_WITH_NO_DISPENSE = 52, ///< Heparin settings are zero but pre-stop setting is non-zero NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration