Index: MsgDefs.h =================================================================== diff -u -rbaad6be9e4a7191e5cb1ba65d819816482aade70 -re52a734267f68afe0147f7114965a1847c3c6dc2 --- MsgDefs.h (.../MsgDefs.h) (revision baad6be9e4a7191e5cb1ba65d819816482aade70) +++ MsgDefs.h (.../MsgDefs.h) (revision e52a734267f68afe0147f7114965a1847c3c6dc2) @@ -9,7 +9,7 @@ * @file MsgDefs.h * * @author (last) Sean Nash -* @date (last) 14-Apr-2023 +* @date (last) 24-May-2023 * * @author (original) Sean * @date (original) 27-Feb-2020 @@ -383,6 +383,11 @@ MSG_ID_HD_DIAL_OUT_PUMP_HARD_STOP = 0x8090, ///< HD dialysate outlet pump hard stop command MSG_ID_HD_BLOOD_PUMP_HARD_STOP = 0x8091, ///< HD blood pump hard stop command MSG_ID_HD_DIALIN_CHECK_IN = 0x8092, ///< HD dialin check in + MSG_ID_HD_ENABLE_VENOUS_BUBBLE_ALARM_DETECTION = 0x8093, ///< HD enable venous bubble alarm detection + MSG_ID_HD_GET_TEST_CONFIGURATION = 0x8094, ///< HD get test configuration + MSG_ID_HD_SEND_TEST_CONFIGURATION = 0x8095, ///< HD send test configuration + MSG_ID_HD_RESET_ALL_TEST_CONFIGURATIONS = 0x8096, ///< HD reset all the configurations + MSG_ID_HD_SET_TEST_CONFIGURATION = 0x8097, ///< HD set test configuration MSG_ID_FIRST_DG_TESTER_MESSAGE = 0xA000, ///< First DG test message ID MSG_ID_DG_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DG_TESTER_MESSAGE, ///< DG tester log-in @@ -490,6 +495,10 @@ MSG_ID_DG_SEND_TEST_CONFIGURATION = 0xA068, ///< DG send test configuration MSG_ID_DG_RESET_ALL_TEST_CONFIGURATIONS = 0xA069, ///< DG reset all the configurations MSG_ID_DG_DIALIN_CHECK_IN = 0xA06A, ///< DG Dialin check in + MSG_ID_DG_GET_LOAD_CELLS_TARE_VALUES = 0xA06B, ///< DG get load cells tare values + MSG_ID_DG_SET_LOAD_CELLS_TARE_VALUES = 0xA06C, ///< DG set load cells tare values + MSG_ID_DG_SEND_LOAD_CELLS_TARE_VALUES = 0xA06D, ///< DG send load cells tare values to dialin + MSG_ID_DG_SET_COND_SENSOR_CAL_TABLE = 0xA06E, ///< DG set conductivity sensor's calibration table MSG_ID_HD_DEBUG_EVENT = 0xFFF1, ///< HD debug event text to be logged in event log MSG_ID_DG_DEBUG_EVENT = 0xFFF2, ///< DG debug event text to be logged in event log @@ -522,8 +531,8 @@ REQUEST_REJECT_REASON_SALINE_BOLUS_IN_PROGRESS = 16, ///< A saline bolus is in progress REQUEST_REJECT_REASON_PARAM_OUT_OF_RANGE = 17, ///< A treatment parameter is out of range REQUEST_REJECT_REASON_HEPARIN_PRESTOP_EXCEEDS_DURATION = 18, ///< The Heparin pre-stop setting is greater than the treatment duration - REQUEST_REJECT_REASON_ARTERIAL_PRESSURE_LOW_VS_HIGH = 19, ///< Arterial pressure low and high alarm limits are not inconsistent - REQUEST_REJECT_REASON_VENOUS_PRESSURE_LOW_VS_HIGH = 20, ///< Venous pressure low and high alarm limits are inconsistent + REQUEST_REJECT_REASON_AVAILABLE_1 = 19, ///< Not used + REQUEST_REJECT_REASON_AVAILABLE_2 = 20, ///< Not used REQUEST_REJECT_REASON_SALINE_MAX_VOLUME_REACHED = 21, ///< Saline bolus volume maximum has been reached - no more saline allowed REQUEST_REJECT_REASON_SALINE_BOLUS_NOT_IN_PROGRESS = 22, ///< A saline bolus is not in progress REQUEST_REJECT_REASON_ACTION_DISABLED_IN_CURRENT_STATE = 23, ///< Requested user action is disabled in current state @@ -561,6 +570,7 @@ REQUEST_REJECT_REASON_DG_RO_ONLY_MODE_INVALID_PARAMETER = 55, ///< DG RO only mode invalid parameter REQUEST_REJECT_REASON_DG_RO_ONLY_MODE_INVALID_PAYLOAD_LENGTH = 56, ///< DG RO only mode invalid payload length REQUEST_REJECT_REASON_TREATMENT_CANNOT_BE_RESUMED = 57, ///< Cannot resume treatment per alarm + REQUEST_REJECT_REASON_EXCEEDS_MAXIMUM_HEPARIN_VOLUME = 58, ///< Cannot continue due to maximum herparin volume NUM_OF_REQUEST_REJECT_REASONS ///< Number of settings change reject codes }; typedef enum Request_Reject_Reasons REQUEST_REJECT_REASON_CODE_T; ///< Type for settings change rejection reason codes enumeration