Index: MsgDefs.h =================================================================== diff -u -rdabc6da0de0a2a4c7d92384a95032573f9965aee -r0be4645ebc81baa6f1553473185ff06ee42d06f8 --- MsgDefs.h (.../MsgDefs.h) (revision dabc6da0de0a2a4c7d92384a95032573f9965aee) +++ MsgDefs.h (.../MsgDefs.h) (revision 0be4645ebc81baa6f1553473185ff06ee42d06f8) @@ -137,15 +137,15 @@ MSG_ID_HD_SYRINGE_PUMP_DATA = 0x69, ///< HD broadcast of syringe pump data MSG_ID_HD_FLUID_LEAK_STATE = 0x6A, ///< HD broadcast of fluid leak state MSG_ID_DG_FLUID_LEAK_STATE = 0x6B, ///< DG broadcast of fluid leak state - MSG_ID_HD_BLOOD_LEAK_STATUS = 0x6C, ///< HD broadcast of blood leak status + MSG_ID_HD_BLOOD_LEAK_DATA = 0x6C, ///< HD broadcast of blood leak data MSG_ID_UI_START_TREATMENT_REQUEST = 0x71, ///< UI user has requested to start treatment MSG_ID_HD_START_TREATMENT_RESPONSE = 0x72, ///< HD response to user request to start treatment MSG_ID_UI_DISPOSABLE_REMOVAL_CONFIRM = 0x73, ///< UI user has confirmed disposable removal MSG_ID_HD_DISPOSABLE_REMOVAL_CONFIRM_RESPONSE = 0x74, ///< HD response to user confirmation of disposable removal MSG_ID_UI_TREATMENT_LOG_DATA_REQUEST = 0x75, ///< UI request treatment log data message MSG_ID_HD_TREATMENT_LOG_DATA_RESPONSE = 0x76, ///< HD response to UI treatment log data request MSG_ID_HD_POST_TREATMENT_STATE = 0x77, ///< HD broadcast of post-treatment state - MSG_ID_HD_BLOOD_LEAK_STATE = 0x78, ///< HD broadcast of blood leak state + MSG_ID___AVAILABLE_16 = 0x78, ///< This msg ID is available for use MSG_ID_DG_START_STOP_FLUSH = 0x79, ///< DG start/stop flush mode MSG_ID_DG_FLUSH_DATA = 0x7A, ///< DG flush data publish @@ -226,15 +226,14 @@ MSG_ID_HD_SET_SERVICE_RECORD = 0x8044, ///< HD set service record that is received from Dialin MSG_ID_HD_SEND_SERVICE_RECORD = 0x8045, ///< HD send service record to CAN bus to be received in Dialin (equivalent to publish) MSG_ID_HD_SET_OP_MODE_REQUEST = 0x8046, ///< HD set operation mode request - MSG_ID_HD_FLUID_LEAK_SEND_INTERVAL_OVERRIDE = 0x8047, ///< HD fluid leak state broadcast interval override request - MSG_ID_HD_FLUID_LEAK_STATE_DETECTOR_OVERRIDE = 0x8048, ///< HD fluid leak state detector override request + MSG_ID_HD_FLUID_LEAK_SEND_INTERVAL_OVERRIDE = 0x8047, ///< HD fluid leak detector state broadcast interval override request + MSG_ID_HD_FLUID_LEAK_STATE_OVERRIDE = 0x8048, ///< HD fluid leak detector state override request MSG_ID_HD_SYRINGE_PUMP_MEASURED_HOME_OVERRIDE = 0x8049, ///< HD syringe pump measured home override request MSG_ID_HD_SYRINGE_PUMP_MEASURED_POSITION_OVERRIDE = 0x804A, ///< HD syringe pump measured position override request MSG_ID_HD_SYRINGE_PUMP_MEASURED_VOLUME_OVERRIDE = 0x804B, ///< HD syringe pump measured volume delivered override request - MSG_ID_HD_BLOOD_LEAK_STATUS_SEND_INTERVAL_OVERRIDE = 0x804C, ///< HD blood leak status broadcast interval override request - MSG_ID_HD_BLOOD_LEAK_STATUS_DETECTOR_OVERRIDE = 0x804D, ///< HD blood leak status detector override request - MSG_ID_HD_BLOOD_LEAK_STATE_SEND_INTERVAL_OVERRIDE = 0x804E, ///< HD blood leak state broadcast interval override request - MSG_ID_HD_BLOOD_LEAK_STATE_DETECTOR_OVERRIDE = 0x804F, ///< HD blood leak state detector override request + MSG_ID_HD_BLOOD_LEAK_DATA_SEND_INTERVAL_OVERRIDE = 0x804C, ///< HD blood leak detector data broadcast interval override request + MSG_ID_HD_BLOOD_LEAK_STATUS_OVERRIDE = 0x804D, ///< HD blood leak detector status override request + MSG_ID_HD_BLOOD_LEAK_STATE_OVERRIDE = 0x804E, ///< HD blood leak detector state override request MSG_ID_FIRST_DG_TESTER_MESSAGE = 0xA000, ///< First DG test message ID MSG_ID_DG_TESTER_LOGIN_REQUEST = MSG_ID_FIRST_DG_TESTER_MESSAGE, ///< DG tester log-in