Index: AlarmDefs.h =================================================================== diff -u -r756b67730cf654e5ed0fd17964f6b23f57177401 -r09d51d1cc6fb19f793893bfdef543f1bd264dbf4 --- AlarmDefs.h (.../AlarmDefs.h) (revision 756b67730cf654e5ed0fd17964f6b23f57177401) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 09d51d1cc6fb19f793893bfdef543f1bd264dbf4) @@ -124,8 +124,8 @@ ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT = 86, ///< Air trap fill timeout during treatment ALARM_ID_BLOOD_FLOW_SIGNAL_STRENGTH_TOO_LOW = 87, ///< Blood flow sensor signal strength too low ALARM_ID_DIALYSATE_FLOW_SIGNAL_STRENGTH_TOO_LOW = 88, ///< Dialysate flow sensor signal strength too low - ALARM_ID_EMPTY_SALINE_BAG = 89, ///< Saline bag is empty - ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE = 90, ///< Saline bolus volume check failure + ALARM_ID_EMPTY_SALINE_BAG = 89, ///< HD Saline bag is empty + ALARM_ID_SALINE_BOLUS_VOLUME_CHECK_FAILURE = 90, ///< HD Saline bolus volume check failure ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT = 91, ///< FPGA reports failure reading arterial pressure sensor ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT = 92, ///< FPGA reports failure reading venous pressure sensor ALARM_ID_UV_REACTOR_NOT_HEALTHY = 93, ///< UV reactor not healthy (either inlet or outlet) @@ -166,6 +166,7 @@ ALARM_ID_PRE_TREATMENT_SELF_TEST_FAILURE = 128, ///< HD pre-treatment mode self-tests failure ALARM_ID_INSTALL_NEW_CARTRIDGE = 129, ///< HD needs new cartridge to be installed ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY = 130, ///< HD cartridge installed improperly alarm + ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE = 131, ///< HD rinseback volume check failure NUM_OF_ALARM_IDS ///< Total number of alarms }; typedef enum Alarm_List ALARM_ID_T; ///< Type for alarm list enumeration @@ -396,6 +397,7 @@ { ALARM_PRIORITY_HIGH, 4, 0, ALARM_ID_NO_ALARM, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE }, // ALARM_ID_PRETREATMENT_SELF_TEST_FAILURE { ALARM_PRIORITY_LOW, 4, 0, ALARM_ID_NO_ALARM, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE }, // ALARM_ID_INSTALL_NEW_CARTRIDGE { ALARM_PRIORITY_LOW, 4, 0, ALARM_ID_NO_ALARM, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE }, // ALARM_ID_CARTRIDGE_INSTALLED_IMPROPERLY + { ALARM_PRIORITY_MEDIUM, 3, ALM_ESC_4_MIN, ALARM_ID_BLOOD_SITTING_WARNING, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE }, // ALARM_ID_RINSEBACK_VOLUME_CHECK_FAILURE // Priority Rank Escalate In Escalate To Fault Stops ClrIm NoClr NoRes NoRin NoEnd NoNew UsrAck };