Index: AlarmDefs.h =================================================================== diff -u -r777794399cf1f6e44edeacd16c9b81012dad9e7d -r11a383d49ccfd914a48d63e4cc4deb9c60be595e --- AlarmDefs.h (.../AlarmDefs.h) (revision 777794399cf1f6e44edeacd16c9b81012dad9e7d) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 11a383d49ccfd914a48d63e4cc4deb9c60be595e) @@ -7,8 +7,8 @@ * * @file AlarmDefs.h * -* @author (last) Dara Navaei -* @date (last) 18-Mar-2023 +* @author (last) James Walter Taylor +* @date (last) 27-Mar-2023 * * @author (original) Sean * @date (original) 11-Feb-2020 @@ -711,15 +711,15 @@ { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_MEDIUM, 803, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_BY_USER, 0, ALARM_ID_NO_ALARM }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To - { ALARM_PRIORITY_LOW, 904, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_LOW, 904, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 905, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_OUT_OF_TIME, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 910, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_PRESSURE_IN_HIGH_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE, 0, ALARM_ID_NO_ALARM },