Index: AlarmDefs.h =================================================================== diff -u -r841ad6d36173bb672c72780746d37b3b04b1f165 -r20858276117cbb9d27fd58f45819d89ee0d16f3a --- AlarmDefs.h (.../AlarmDefs.h) (revision 841ad6d36173bb672c72780746d37b3b04b1f165) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 20858276117cbb9d27fd58f45819d89ee0d16f3a) @@ -695,7 +695,7 @@ { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_CIRCULATION_LINE_TIMEOUT }, { ALARM_PRIORITY_LOW, 850, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BATTERY_PACK_ERROR_DETECTED }, { ALARM_PRIORITY_HIGH, 290, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_BLOOD_SITTING_WARNING }, - { ALARM_PRIORITY_HIGH, 290, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_END_OF_TREATMENT_ALARM }, + { ALARM_PRIORITY_HIGH, 290, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_END_OF_TREATMENT_ALARM }, { ALARM_PRIORITY_MEDIUM, 590, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_PRIME_COMPLETED_MEDIUM }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_30 }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_31 }, @@ -709,7 +709,7 @@ { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_MEDIUM, 300, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_TREATMENT_STOPPED_BY_USER }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID - { ALARM_PRIORITY_LOW, 739, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_END_OF_TREATMENT_WARNING }, + { ALARM_PRIORITY_LOW, 739, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_END_OF_TREATMENT_WARNING }, { ALARM_PRIORITY_LOW, 729, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_PRIME_COMPLETED_LOW_PRIORITY }, { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_15 }, { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT }, @@ -1383,7 +1383,7 @@ { 222 , ALARM_ID_HD_OCCLUSION_SENSOR_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nHD Fault: BP Occ Com | HD occlusion sensor FPGA fault | If the FPGA does not report fresh data or indicates an error for a certain period of time. | "}, { 223 , ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair.\n\nHD Fault: Art. Pres. Com | HD arterial sensor FPGA fault | If the FPGA does not report fresh data for a certain period of time | "}, { 224 , ALARM_ID_HD_TREATMENT_STOPPED_BY_USER , "HD | Blood Pump Stopped: Treatment Paused | Treatment has been stopped by user.\n- Press OK to resume treatment. \n- If treatment is not resumed within five minutes,\ntreatment will be terminated without rinseback. \n\nBlood Stopped: Treatment Pause | Treatment stopped by user action - pressed stop button | If the user has pressed the stop button. | "}, - { 225 , ALARM_ID_HD_END_OF_TREATMENT_WARNING , "HD | Treatment Complete | Dialysis treatment is complete.\n- Press OK to end treatment and rinseback.\n\nProcess: End of Treatment | HD end of treatment warning | If the treatment duration has exceeded the prescribed treatment time entered by the user. | "}, + { 225 , ALARM_ID_HD_END_OF_TREATMENT_WARNING , "HD | Treatment Complete | Dialysis treatment is complete.\n- If blood sampling is required, draw blood at\n the arterial sample port\n- Press RINSEBACK to end treatment and rinseback.\n\nProcess: End of Treatment | HD end of treatment warning | If the treatment duration has exceeded the prescribed treatment time entered by the user. | "}, { 226 , ALARM_ID_HD_PRIME_COMPLETED_LOW_PRIORITY , "HD | Priming Complete | Priming is complete. \n- Treatment must begin within 120 minutes \nor the pre- treatment process will be terminated.\n- Press OK to continue. \n\nProcess: Pre- Tx Priming Complete | HD prime completed low priority alarm | Start of Pre-Treatment Recirculation - notifiy user to proceed to patient connection | "}, { 227 , ALARM_ID_AVAILABLE_15 , " | | \n\n | | | "}, { 228 , ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT , "HD | Priming Error | A problem has been detected during prime. \n- Prime was unable to complete. \n - Check blood and dialysate lines for clamps, kinks or leaks. \n\nProcess: Pre- Tx Prime Timeout | HD time out on prime sub-mode purge air state. | During the pre-treatment prime state, if the prime saline purge air state exceeded 60 secs. | "},