Index: AlarmDefs.h =================================================================== diff -u -r9ebd6c3ebfbbf2fad65c7cb007bee9ab481eb21e -r366dc10cc5265ee299ccbf8202db5c6f8f8816ca --- AlarmDefs.h (.../AlarmDefs.h) (revision 9ebd6c3ebfbbf2fad65c7cb007bee9ab481eb21e) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 366dc10cc5265ee299ccbf8202db5c6f8f8816ca) @@ -228,7 +228,7 @@ ALARM_ID_DG_DRAIN_PUMP_OFF_FAULT = 190, ///< DG drain pump off fault ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE = 191, ///< DG flow rate out of upper range ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE = 192, ///< DG flow rate out of lower range - ALARM_ID_AVAILABLE_5 = 193, ///< HD dialysate temperature out of low safety range. + ALARM_ID_HD_PARTIAL_OCCLUSION_BLOOD_PUMP = 193, ///< HD blood pump partial occlusion detected. ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE = 194, ///< DG RO pump duty cycle out of range ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE = 195, ///< DG RO pump pressure out of range ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT = 196, ///< DG CPi/CPo sensors FPGA fault @@ -678,7 +678,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_OFF_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_AVAILABLE_5 }, + { ALARM_PRIORITY_HIGH, 17, FALSE, FALSE, TRUE , TRUE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_HD_PARTIAL_OCCLUSION_BLOOD_PUMP }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT }, @@ -858,6 +858,7 @@ { 1, ALARM_ID_HD_UI_POST_FAILURE_ETHERNET }, { 1, ALARM_ID_HD_UI_POST_FAILURE_SOUND }, { 1, ALARM_ID_HD_INVALID_INSTITUTIONAL_RECORD_CRC }, + { 1, ALARM_ID_HD_PARTIAL_OCCLUSION_BLOOD_PUMP }, { 2, ALARM_ID_DG_INTEGRITY_POST_TEST_FAILED }, { 2, ALARM_ID_DG_ACCELEROMETER_SELF_TEST_FAILURE }, { 2, ALARM_ID_DG_WATCHDOG_POST_TEST_FAILED }, @@ -1132,7 +1133,6 @@ { 852, ALARM_ID_HD_AC_POWER_LOST }, { 999, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, { 999, ALARM_ID_AVAILABLE_2 }, - { 999, ALARM_ID_AVAILABLE_5 }, { 999, ALARM_ID_AVAILABLE_7 }, { 999, ALARM_ID_AVAILABLE_10 }, { 999, ALARM_ID_AVAILABLE_13 }, @@ -1357,7 +1357,7 @@ { 190 , ALARM_ID_DG_DRAIN_PUMP_OFF_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: DRP Speed Not Off | DG drain pump off fault | If the pump is in off state and the RPM is greater than the minimum RPM of 300.0 RPM. | "}, { 191 , ALARM_ID_DG_FLOW_RATE_OUT_OF_UPPER_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Flow High | DG flow rate out of upper range | If the RO flow rate > 10% from the target flow rate. | "}, { 192 , ALARM_ID_DG_FLOW_RATE_OUT_OF_LOWER_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Flow Low | DG flow rate out of lower range | If the RO flow rate < 10% from the target flow rate. | "}, - { 193 , ALARM_ID_AVAILABLE_5 , " | | | | | | "}, + { 193 , ALARM_ID_HD_PARTIAL_OCCLUSION_BLOOD_PUMP , "HD | Blood Pump Stopped: Partial Occlusion | Partial Occlusion detected after the blood pump.\n- Inspect bloodlines for kinks or clamps.\n- Check needle placement or access position.\n- Resolve access issues, if applicable.\n- If clots are present, end treatment without rinseback. | Blood Stop: Blood Pump Partial Occlusion | Blood pump partial occlusion detected | If blood occlusion is detected > PARTIAL_OCCLUSION_THRESHOLD_OFFSET + bloodPumpOcclusionDuringTreatement | "}, { 194 , ALARM_ID_DG_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Driver Feedback | DG RO pump duty cycle out of range | If the DG RO pump duty cycle is out of range by 5% of the target duty cycle for a certain period of time. | "}, { 195 , ALARM_ID_DG_RO_PUMP_PRESSURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Pump High Pressure | DG RO pump pressure out of range | If the DG RO pump pressure > 135 psi for a certain period of time. | "}, { 196 , ALARM_ID_DG_CPI_CPO_SENSORS_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: CPi/CPo Comm | DG CPi/CPo conductivity sensors FPGA fault | If the FPGA reports error for a certain period of time. | "},