Index: AlarmDefs.h =================================================================== diff -u -r454b38efdd19fea411600a37f3521ea1c32f3c2a -r47ec13687571478a506407215129d46b06a3770e --- AlarmDefs.h (.../AlarmDefs.h) (revision 454b38efdd19fea411600a37f3521ea1c32f3c2a) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 47ec13687571478a506407215129d46b06a3770e) @@ -151,7 +151,7 @@ ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE = 113, ///< DG Drain pump current out of range ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE = 114, ///< HD venous air bubble detector self-test failure ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE = 115, ///< DG temperature sensor out of range - ALARM_ID_DG___AVAILABLE_4 = 116, ///< Available for use + ALARM_ID_HD_UI_SDCARD_FAILURE = 116, ///< HD UI SD card failure ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED = 117, ///< DG CAN message not acked ALARM_ID_DG_RTC_CONFIG_ERROR = 118, ///< DG RTC config error ALARM_ID_DG_RTC_BATTERY_LOW = 119, ///< DG RTC battery low error @@ -592,7 +592,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE }, { ALARM_PRIORITY_LOW, 725, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE }, - { ALARM_PRIORITY_HIGH, 3, TRUE , TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG___AVAILABLE_4 }, + { ALARM_PRIORITY_LOW, 850, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_UI_SDCARD_FAILURE }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RTC_CONFIG_ERROR }, { ALARM_PRIORITY_LOW, 851, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_RTC_BATTERY_LOW }, @@ -616,13 +616,13 @@ { ALARM_PRIORITY_MEDIUM, 440, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_SHOCK }, { ALARM_PRIORITY_HIGH, 211, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_EXCESSIVE_TILT }, { ALARM_PRIORITY_MEDIUM, 441, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_EXCESSIVE_TILT }, - { ALARM_PRIORITY_HIGH, 852, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AC_POWER_LOST }, + { ALARM_PRIORITY_HIGH, 852, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_AC_POWER_LOST }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_COMM_TIMEOUT }, { ALARM_PRIORITY_HIGH, 205, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_AIR_TRAP_FILL_DURING_TREATMENT }, { ALARM_PRIORITY_HIGH, 206, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , ALARM_ID_OCCLUSION_BLOOD_PUMP }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 603, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_COND_TOO_HIGH }, - { ALARM_PRIORITY_MEDIUM, 410, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, + { ALARM_PRIORITY_MEDIUM, 410, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 421, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT }, { ALARM_PRIORITY_MEDIUM, 601, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_HIGH }, @@ -637,7 +637,7 @@ { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_DG_OPERATION_MODE_MESSAGE_NOT_RECEIVE }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, { ALARM_PRIORITY_MEDIUM, 433, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_TEMPERATURE_IN_LOW_RANGE }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID }, + { ALARM_PRIORITY_LOW, 751, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_BLOOD_PUMP_ROTOR_SPEED_TOO_HIGH }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_COMM_TOO_MANY_BAD_CRCS }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FPGA_CLOCK_SPEED_CHECK_FAILURE }, @@ -648,7 +648,7 @@ { ALARM_PRIORITY_HIGH, 209, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_CARTRIDGE_DOOR_OPENED }, { ALARM_PRIORITY_HIGH, 799, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID__AVAILABLE_70 }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FLOW_RATE_OUT_OF_MAX_RANGE }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { ALARM_PRIORITY_LOW, 730, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, { ALARM_PRIORITY_LOW, 716, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_OCCLUSION }, { ALARM_PRIORITY_LOW, 715, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_NOT_ENOUGH_HEPARIN_ALARM }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_RTC_CONFIG_ERROR }, @@ -698,29 +698,29 @@ { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID___AVAILABLE_10 }, { ALARM_PRIORITY_HIGH, 291, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_TREATMENT_TIMEOUT_ALARM }, { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID___AVAILABLE_11 }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_DETECTED }, + { ALARM_PRIORITY_LOW, 745, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_DETECTED }, { ALARM_PRIORITY_HIGH , 207, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_REMOVED }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_THD_SENSORS_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 204, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, ALARM_ID_EMPTY_SALINE_BAG }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_OCCLUSION_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, { ALARM_PRIORITY_MEDIUM, 300, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_BY_USER }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID - { ALARM_PRIORITY_LOW, 904, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING }, + { ALARM_PRIORITY_LOW, 739, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_END_OF_TREATMENT_WARNING }, { ALARM_PRIORITY_LOW, 729, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY }, - { ALARM_PRIORITY_LOW, 909, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_PRIME_OUT_OF_TIME }, + { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_OUT_OF_TIME }, { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRIME_SALINE_PURGE_AIR_TIME_OUT }, { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT }, { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_DRY_PRESSURE_TEST_FAILURE }, { ALARM_PRIORITY_LOW, 725, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BAROMETRIC_SENSOR_COEFFS_BAD_CRC }, { ALARM_PRIORITY_MEDIUM, 430, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , ALARM_ID_INLET_WATER_PRESSURE_IN_HIGH_RANGE }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, + { ALARM_PRIORITY_LOW, 738, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_INSTALL_NEW_CARTRIDGE }, { ALARM_PRIORITY_LOW, 720, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_NO_CARTRIDGE_LOADED }, - { ALARM_PRIORITY_LOW, 999, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, + { ALARM_PRIORITY_LOW, 746, FALSE, FALSE, TRUE , FALSE, FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, { ALARM_PRIORITY_MEDIUM, 411, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT }, @@ -731,7 +731,7 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_62 }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_COND_OUT_OF_RANGE }, - { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, + { ALARM_PRIORITY_LOW, 750, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC }, @@ -804,7 +804,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT }, { ALARM_PRIORITY_HIGH, 10, TRUE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , ALARM_ID_HD_AIR_PUMP_TIMEOUT }, { ALARM_PRIORITY_MEDIUM, 899, FALSE, FALSE, FALSE, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE }, - { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, + { ALARM_PRIORITY_LOW, 752, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY }, }; // Priority Rank Fault DFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To @@ -870,7 +870,6 @@ { 2, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD }, { 3, ALARM_ID_AVAILABLE_61 }, { 3, ALARM_ID_AVAILABLE_51 }, - { 3, ALARM_ID_DG___AVAILABLE_4 }, { 3, ALARM_ID_AVAILABLE_50 }, { 3, ALARM_ID_HD___AVAILABLE_1 }, { 3, ALARM_ID___AVAILABLE_7 }, @@ -1072,7 +1071,6 @@ { 600, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT }, { 600, ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE }, { 600, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE }, - { 600, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { 600, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT }, { 600, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, { 600, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, @@ -1098,12 +1096,21 @@ { 720, ALARM_ID_PRIME_DIALYSATE_DIALYZER_TIME_OUT }, { 720, ALARM_ID_PRIME_DIALYSATE_BYPASS_TIME_OUT }, { 720, ALARM_ID_PRIME_SALINE_DIALYZER_TIME_OUT }, + { 720, ALARM_ID_PRIME_OUT_OF_TIME }, { 725, ALARM_ID_HD_BLOOD_LEAK_SENSOR_ZERO_SEQUENCE_FAILED }, { 725, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, { 725, ALARM_ID_PRE_TREATMENT_WET_PRIME_TEST_FAILURE }, { 725, ALARM_ID_PRE_TREATMENT_WET_LC_TEST_FAILURE }, { 725, ALARM_ID_PRE_TREATMENT_WET_FLOW_TEST_FAILURE }, { 729, ALARM_ID_PRIME_COMPLETED_LOW_PRIORITY }, + { 730, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, + { 738, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, + { 739, ALARM_ID_END_OF_TREATMENT_WARNING }, + { 745, ALARM_ID_HD_SYRINGE_DETECTED }, + { 746, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, + { 750, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, + { 751, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID }, + { 752, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { 799, ALARM_ID___AVAILABLE_5 }, { 799, ALARM_ID__AVAILABLE_70 }, { 799, ALARM_ID_CREATING_DIALYSATE_PLEASE_WAIT }, @@ -1115,23 +1122,16 @@ { 850, ALARM_ID_HD_BATTERY_COMM_FAULT }, { 850, ALARM_ID_HD_RTC_BATTERY_LOW }, { 850, ALARM_ID_HD_FAN_RPM_OUT_OF_RANGE }, + { 850, ALARM_ID_HD_UI_SDCARD_FAILURE }, { 851, ALARM_ID_DG_RTC_BATTERY_LOW }, { 851, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, { 852, ALARM_ID_HD_AC_POWER_LOST }, { 899, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_FLUSH_SAMPLE }, - { 899, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_REMOVE_ACID }, - { 899, ALARM_ID_DG_CHEM_DISINFECT_INSERT_ACID }, { 899, ALARM_ID___AVAILABLE_9 }, { 899, ALARM_ID___AVAILABLE_10 }, { 899, ALARM_ID___AVAILABLE_11 }, - { 899, ALARM_ID_HD_SYRINGE_DETECTED }, { 899, ALARM_ID___AVAILABLE_6 }, { 899, ALARM_ID_AVAILABLE_63 }, - { 904, ALARM_ID_END_OF_TREATMENT_WARNING }, - { 909, ALARM_ID_PRIME_OUT_OF_TIME }, - { 999, ALARM_ID_TREATMENT_STOPPED_AFTER_RINSEBACK }, - { 999, ALARM_ID_CARTRIDGE_REMOVAL_FAILURE }, - { 999, ALARM_ID_HD_SYRINGE_PUMP_SYRINGE_EMPTY }, { 999, ALARM_ID_NO_ALARM }, }; @@ -1269,7 +1269,7 @@ { 113 , ALARM_ID_DG_DRAIN_PUMP_CURRENT_OUT_OF_RANGE , "DG | Drain Pump Error | Call service to schedule a repair. | DG drain pump current out of range | If the DG drain pump current > 2.2 A when it is in open loop or if the current > 0.1 A when it is off. | "}, { 114 , ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE , "HD | Air Bubble Detector Error | Call service to schedule a repair. | HD venous air bubble detector self-test failure | If the venous air bubble self test did not detect bubble for more than 500 msec. | "}, { 115 , ALARM_ID_DG_TEMPERATURE_SENSOR_OUT_OF_RANGE , "DG | Dialysate Temperature Error | Call service to schedule a repair. | DG temperature sensor out of range | If the measured temperature < 0 C or > 80 C for the non-fluid inline sensors and > 120 C for the fluid sensors. | "}, - { 116 , ALARM_ID_DG___AVAILABLE_4 , "NA | Not used | Call service to schedule a repair. | | | "}, + { 116 , ALARM_ID_HD_UI_SDCARD_FAILURE , "NA | Not used | Call service to schedule a repair. | | | "}, { 117 , ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED , "DG | Machine Error | Call service to schedule a repair. | System message that required acknowledgment was not acknowledged | If no retries left in the pending acknowlegement list. | "}, { 118 , ALARM_ID_DG_RTC_CONFIG_ERROR , "DG | RTC Error | Call service to schedule a repair. | DG RTC configuration error | If the RTC configuration registers report an error. | "}, { 119 , ALARM_ID_DG_RTC_BATTERY_LOW , "DG | RTC Error | Call service to schedule a repair. | DG RTC battery low | If the RTC battery bit report a low alarm. | "},