Index: AlarmDefs.h =================================================================== diff -u -r928da2fa03ce7e54df15553811caedc71ecebce1 -r5b19f35e6a9aa70aac72f4a7594181c50e4167b8 --- AlarmDefs.h (.../AlarmDefs.h) (revision 928da2fa03ce7e54df15553811caedc71ecebce1) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 5b19f35e6a9aa70aac72f4a7594181c50e4167b8) @@ -182,7 +182,7 @@ ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC = 144, ///< DG software configuration record invalid CRC. ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE = 145, ///< Concentrate conductivity after adding acid out of range alarm ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE = 146, ///< Dialysate conductivity out of range - ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT = 147, ///< DG dialysate generation conductivity fault alarm + ALARM_ID_REPLACE_CONCENTRATE_BOTTLES = 147, ///< DG dialysate generation conductivity fault alarm ALARM_ID_INLET_WATER_HIGH_TEMPERATURE = 148, ///< Inlet water temperature too high ALARM_ID_INLET_WATER_LOW_TEMPERATURE = 149, ///< Inlet water temperature too low ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_WARNING_RANGE = 150, ///< Inlet water conductivity is in warning range @@ -594,7 +594,7 @@ { ALARM_PRIORITY_LOW, 21, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 22, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 23, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 24, FALSE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 24, FALSE, FALSE, TRUE , TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, TRUE, FALSE, TRUE, ALARM_ID_REPLACE_CONCENTRATE_BOTTLES, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 26, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 28, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE, ALARM_ID_INLET_WATER_LOW_TEMPERATURE, 0, ALARM_ID_NO_ALARM }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoNew NoRcr UsrAck TxLog ID Escalate In Escalate To @@ -923,7 +923,7 @@ { 21, ALARM_ID_DG_SW_CONFIG_RECORD_INVALID_CRC }, { 22, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 23, ALARM_ID_DIALYSATE_CONDUCTIVITY_OUT_OF_RANGE }, - { 24, ALARM_ID_DIALYSATE_CONDUCTIVITY_FAULT }, + { 24, ALARM_ID_REPLACE_CONCENTRATE_BOTTLES }, { 26, ALARM_ID_INLET_WATER_HIGH_TEMPERATURE }, { 28, ALARM_ID_INLET_WATER_LOW_TEMPERATURE }, { 30, ALARM_ID_INLET_WATER_CONDUCTIVITY_IN_WARNING_RANGE },