Index: AlarmDefs.h =================================================================== diff -u -r304d176a2005bf00493965f1ccff21f4984a240b -r8c80f65e68a41837e91854ff5d155153e91f68aa --- AlarmDefs.h (.../AlarmDefs.h) (revision 304d176a2005bf00493965f1ccff21f4984a240b) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 8c80f65e68a41837e91854ff5d155153e91f68aa) @@ -127,7 +127,7 @@ ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW = 89, ///< DG outlet UV reactor on with no flow ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT = 90, ///< DG load cells A1/B1 FPGA fault ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE = 91, ///< HD No dialysate flow data receive in the last 3 seconds - ALARM_ID_AVAILABLE_1 = 92, ///< Available for use + ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD = 92, ///< DG temperature sensors invalid calibration record ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE = 93, ///< DG outlet primary conductivity out of range ALARM_ID_DG_PRESSURE_OUT_OF_RANGE = 94, ///< DG pressure out of range ALARM_ID_DG_WATCHDOG_EXPIRED = 95, ///< DG watchdog expired @@ -573,7 +573,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT }, { ALARM_PRIORITY_HIGH, 111, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE }, - { ALARM_PRIORITY_LOW, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_1 }, + { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_PRESSURE_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_WATCHDOG_EXPIRED }, @@ -813,7 +813,7 @@ { ALARM_PRIORITY_LOW, 752, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_INVALID_YEAR }, - // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID + // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_UI_POST_FAILURE_SETTINGS_BAD }, }; // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID @@ -878,6 +878,7 @@ { 2, ALARM_ID_DG_INVALID_SERIAL_NUMBER }, { 2, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD }, { 2, ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE }, + { 2, ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD }, { 10, ALARM_ID_HD_SOFTWARE_FAULT }, { 10, ALARM_ID_HD_BLOOD_PUMP_MC_CURRENT_CHECK }, { 10, ALARM_ID_HD_BLOOD_PUMP_OFF_CHECK }, @@ -1131,7 +1132,6 @@ { 851, ALARM_ID_DG_FAN_RPM_OUT_OF_RANGE }, { 852, ALARM_ID_HD_AC_POWER_LOST }, { 999, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, - { 999, ALARM_ID_AVAILABLE_1 }, { 999, ALARM_ID_AVAILABLE_5 }, { 999, ALARM_ID_AVAILABLE_6 }, { 999, ALARM_ID_AVAILABLE_7 }, @@ -1256,7 +1256,7 @@ { 89 , ALARM_ID_DG_OUTLET_UV_REACTOR_ON_WITH_NO_FLOW , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: UVo On No Flow | DG outlet UV reactor is on while there is no flow | If the outlet UV reactor is on while the RO flow is less than 200 mL/min. | "}, { 90 , ALARM_ID_DG_LOAD_CELL_A1_B1_FPGA_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: LC A1/B1 Comm | DG load cells A1/B1 FPGA fault | If the FPGA does not report fresh data for a certain period of time. | "}, { 91 , ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE , "HD | Communication Error | A communication problem has been detected.\n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | Loss of DG Comm (FMD) | HD No dialysate flow data received in the last 3 seconds | If not receiving new dialysate flow readings in expected interval (3 seconds) | "}, - { 92 , ALARM_ID_AVAILABLE_1 , " | | | | | | "}, + { 92 , ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG POST: Temp Snsr Cal | DG temperature sensors invalid calibration | If the calibration date of the temperature sensors is 0. | "}, { 93 , ALARM_ID_DG_OUTLET_PRIMARY_CONDUCTIVITY_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Permeate Cond High | DG outlet primary conductivity sensor out of range | If the outlet primary conductivity sensor, CPo is greater than 30 uS/cm for a certain period of time. | "}, { 94 , ALARM_ID_DG_PRESSURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Pressure Sensor Range | DG pressure sensor out of range | If either of the pressure sensors is < 0 psia or > 200 psia for DG pressure sensors. | "}, { 95 , ALARM_ID_DG_WATCHDOG_EXPIRED , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: WD Error | DG watchdog expired | If the watchdog signal is low while not in POST. | "},