Index: AlarmDefs.h =================================================================== diff -u -rf96f7c7b7c048f0d49eb7ccf476fd69378a1fafe -r90961069b30c0188cdaae90923e22f16ca78e3d5 --- AlarmDefs.h (.../AlarmDefs.h) (revision f96f7c7b7c048f0d49eb7ccf476fd69378a1fafe) +++ AlarmDefs.h (.../AlarmDefs.h) (revision 90961069b30c0188cdaae90923e22f16ca78e3d5) @@ -279,13 +279,13 @@ ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT = 241, ///< DG reservoir drain time out ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT = 242, ///< DG reservoir fill time out ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT = 243, ///< DG reservoir leak time out - ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE = 244, ///< DG temperature sensors difference out of range + ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE = 244, ///< DG cleaning mode temperature sensors difference out of range ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT = 245, ///< DG heat disinfect target temperature time out (could not reach to temperature) - ALARM_ID_AVAILABLE_3 = 246, ///< Alarm ID available for use + ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE = 246, ///< DG cleaning mode conductivity sensors out of range ALARM_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_TIME_OUT = 247, ///< DG heat disinfect active cool time tour ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT = 248, ///< DG chemical disinfect could not reach to target temperature - ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT = 249, ///< DG chemical disinfect inlet pressure and temperature sensors out of range - ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT = 250, ///< DG chemical disinfect inlet conductivity and temperature out of range + ALARM_ID_AVAILABLE_4 = 249, ///< Alarm ID available for use + ALARM_ID_AVAILABLE_5 = 250, ///< Alarm ID available for use ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC = 251, ///< HD invalid system record ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC = 252, ///< HD invalid service record ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC = 253, ///< DG invalid system record @@ -725,13 +725,13 @@ { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 799, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_3, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_TIME_OUT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_4, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_5, 0, ALARM_ID_NO_ALARM }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd NoBRcr NoDRcr ClrOnly TxLog ID Escalate In Escalate To { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC, 0, ALARM_ID_NO_ALARM }, @@ -956,10 +956,10 @@ { 3, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE }, { 3, ALARM_ID_HD_FPGA_CLOCK_SPEED_CHECK_FAILURE }, { 3, ALARM_ID_RO_PUMP_DUTY_CYCLE_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT }, + { 3, ALARM_ID_AVAILABLE_4 }, { 3, ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT }, - { 3, ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT }, - { 3, ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE }, + { 3, ALARM_ID_AVAILABLE_5 }, + { 3, ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE }, { 3, ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT }, { 3, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, { 3, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, @@ -993,7 +993,7 @@ { 3, ALARM_ID_DG_CD1_CD2_SENSORS_FPGA_FAULT }, { 3, ALARM_ID_HD_RTC_CONFIG_ERROR }, { 3, ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT }, - { 3, ALARM_ID_AVAILABLE_3 }, + { 3, ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE }, { 3, ALARM_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_TIME_OUT }, { 3, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT }, { 3, ALARM_ID_DG_LOAD_CELLS_TARE_WEIGHT_OUT_OF_RANGE }, @@ -1390,13 +1390,13 @@ { 241 , ALARM_ID_DG_RESERVOIR_DRAIN_TIMEOUT , "DG | Cleaning Mode Error | Call service to schedule a repair. | DG reservoir drain time out | If the DG reservoir drain is not complete in 120 secs. | "}, { 242 , ALARM_ID_DG_RESERVOIR_FILL_TIMEOUT , "DG | Cleaning Mode Error | Call service to schedule a repair. | DG reservoir fill time out | If the DG reservoir fill is not complete in 120 secs. | "}, { 243 , ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT , "DG | Heat Disinfection Error | Call service to schedule a repair. | DG reservoir leak time out | If the reservoir level is drifted by 100 mL for more than 30 seconds. | "}, - { 244 , ALARM_ID_DG_TEMP_SENSORS_DIFF_OUT_OF_RANGE , "DG | Heat Disinfection Error | Call service to schedule a repair. | DG temperature sensors difference out of range | If any of the temperature sensors are out of the average of the sensors by more than 3 C. | "}, + { 244 , ALARM_ID_DG_CLEANING_MODE_TEMP_SENSORS_DIFF_OUT_OF_RANGE , "DG | Cleaning Mode Error | Call service to schedule a repair. | DG temperature sensors difference out of range | If any of the temperature sensors are out of the average of the sensors by more than 3 C. | "}, { 245 , ALARM_ID_DG_HEAT_DISINFECT_TARGET_TEMP_TIMEOUT , "DG | Heat Disinfection Error | Call service to schedule a repair. | DG heat disinfect target temperature time out (could not reach to temperature) | If heating up to minimum temperature for heat disinfect failed after 4 hours. | "}, - { 246 , ALARM_ID_AVAILABLE_3 , "N/A | N/A | N/A | N/A | N/A | "}, + { 246 , ALARM_ID_DG_CLEANING_MODE_COND_SENSORS_OUT_OF_RANGE , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect inlet conducitivty out of range | If CPo and CD2 conductivity values are above 100 uS/cm. | "}, { 247 , ALARM_ID_DG_HEAT_DISINFECT_ACTIVE_COOL_TIME_OUT , "DG | Heat Disinfection Active Cool Error | Call service to schedule a repair. | DG heat disinfect active cool time out | If THd > 44 C after 90 minutes of cooling. | "}, { 248 , ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_TIMEOUT , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect could not reach to target temperature | If heating up to minimum temperature for chemical disinfect failed | "}, - { 249 , ALARM_ID_DG_CHEM_DISINFECT_INLET_PRES_AND_TEMP_SNSRS_OUT , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect inlet pressure and temperature sensors out of range | If the inlet pressure is less than the threshold of 30.0 PSI and TDi and TRo difference is greater than 3 C | "}, - { 250 , ALARM_ID_DG_CHEM_DISINFECT_INLET_COND_AND_TEMP_OUT , "DG | Chemical Disinfection Error | Call service to schedule a repair. | DG chemical disinfect inlet conductivity and temperature out of range | If couldn't get a good water sample after a couple of trials and the disinfect cycle failed | "}, + { 249 , ALARM_ID_AVAILABLE_4 , "N/A | N/A | N/A | N/A | N/A | "}, + { 250 , ALARM_ID_AVAILABLE_5 , "N/A | N/A | N/A | N/A | N/A | "}, { 251 , ALARM_ID_HD_INVALID_SYSTEM_RECORD_CRC , "HD | Machine Error | Call service to schedule a repair. | HD invalid system record | If the calculated CRC of the HD system record image does not match the expected CRC. | "}, { 252 , ALARM_ID_HD_INVALID_SERVICE_RECORD_CRC , "HD | Machine Error | Call service to schedule a repair. | HD invalid service record | If the calculated CRC of the HD service record image does not match the expected CRC. | "}, { 253 , ALARM_ID_DG_INVALID_SYSTEM_RECORD_CRC , "DG | Machine Error | Call service to schedule a repair. | DG invalid system record | If the calculated CRC of the DG system record image does not match the expected CRC. | "},