Index: AlarmDefs.h =================================================================== diff -u -rf783b22c8695c773d2bf10be976a0142a39f9acf -ra5833d527d43d7129b8fb60a5fceab0a3c44188b --- AlarmDefs.h (.../AlarmDefs.h) (revision f783b22c8695c773d2bf10be976a0142a39f9acf) +++ AlarmDefs.h (.../AlarmDefs.h) (revision a5833d527d43d7129b8fb60a5fceab0a3c44188b) @@ -238,7 +238,7 @@ ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE = 200, ///< DG thermistors/sensors temperature out of range ALARM_ID_HD_PRE_TREATMENT_WET_FLOW_TEST_FAILURE = 201, ///< HD pre-treatment mode wet self-test lc vs FMD failure ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE = 202, ///< HD pre-treatment mode dry pressure normal self-test failure - ALARM_ID_AVAILABLE_6 = 203, ///< Available for use + ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD = 203, ///< DG fill conductivities acid/bicarb invalid calibration record ALARM_ID_DG_RO_REJECTION_RATIO_OUT_OF_RANGE = 204, ///< DG RO rejection ratio out of range ALARM_ID_DG_CONDUCTIVITY_SENSOR_FAULT = 205, ///< DG conductivity sensor fault ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME = 206, ///< DG dialysate fill runs out of time @@ -689,7 +689,7 @@ { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE }, { ALARM_PRIORITY_LOW, 725, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRE_TREATMENT_WET_FLOW_TEST_FAILURE }, { ALARM_PRIORITY_LOW, 710, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE }, - { ALARM_PRIORITY_LOW, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_6 }, + { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_RO_REJECTION_RATIO_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_CONDUCTIVITY_SENSOR_FAULT }, { ALARM_PRIORITY_HIGH, 110, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, @@ -880,6 +880,7 @@ { 2, ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE }, { 2, ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD }, { 2, ALARM_ID_DG_COND_SENSORS_INVALID_TEMP_COMP_CAL_RECORD }, + { 2, ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD }, { 10, ALARM_ID_HD_SOFTWARE_FAULT }, { 10, ALARM_ID_HD_BLOOD_PUMP_MC_CURRENT_CHECK }, { 10, ALARM_ID_HD_BLOOD_PUMP_OFF_CHECK }, @@ -1134,7 +1135,6 @@ { 852, ALARM_ID_HD_AC_POWER_LOST }, { 999, ALARM_ID_HD_UI_POST_FAILURE_DISPLAY }, { 999, ALARM_ID_AVAILABLE_5 }, - { 999, ALARM_ID_AVAILABLE_6 }, { 999, ALARM_ID_AVAILABLE_7 }, { 999, ALARM_ID_AVAILABLE_8 }, { 999, ALARM_ID_AVAILABLE_10 }, @@ -1367,7 +1367,7 @@ { 200 , ALARM_ID_DG_THERMISTORS_TEMPERATURE_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Thermistor Range | DG thermistor or temperature sensor out of range | If thermistor > 80.0 C or < 0.0 C. | "}, { 201 , ALARM_ID_HD_PRE_TREATMENT_WET_FLOW_TEST_FAILURE , "HD | Self Test: Dialysate Flow Rate | A problem has been detected when measuring dialysate flow.\n- Confirm cartridge is properly installed and primed.\n- If problem persists, terminate treatment preparation and \n start over using a new cartridge. | Process: Pre- Tx Wet Self- Test | HD pre-treatment wet flow test failure | If the pre-treatment wet flow test has failed. | "}, { 202 , ALARM_ID_HD_PRE_TREATMENT_DRY_PRESSURE_NORMAL_TEST_FAILURE , "HD | Self Test: Pressure | A problem has been detected during self- test. \n- Confirm the cartridge is properly installed. \n- Ensure arterial and venous pressure sensor lines are\nnot kinked.\n- Press Resume/OK to resume. \n- If problem persists, install a new cartridge. | Process: Pre- Tx Dry Self- Test | HD pre-treatment dry pressure normal test failure | If the pre-treatment dry pressure normal test failed. | "}, - { 203 , ALARM_ID_AVAILABLE_6 , " | | | | | | "}, + { 203 , ALARM_ID_DG_FILL_CONDUCTIVITIES_INVALID_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG POST: Fill Cond Cal | DG fill acid/bicarb invalid calibration record | If the fill target acid/bicarb conductivities' non-volatile record's calibration time is not 0. | "}, { 204 , ALARM_ID_DG_RO_REJECTION_RATIO_OUT_OF_RANGE , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: RO Rejection | RO rejection ratio out of range | If RO rejection ratio > 0.1 | "}, { 205 , ALARM_ID_DG_CONDUCTIVITY_SENSOR_FAULT , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Cond Sensors Error | Conductivity sensor fault | If conductivity sensor reports 0x11 for more than 2 consecutive reads. | "}, { 206 , ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG Fault: Reservoir Fill Timeout | DG dialysate fill runs out of time | If DG dialysate fill > 5 minutes. | "},