Index: AlarmDefs.h =================================================================== diff -u -r2ce6e18d25ffa0175703106a2ddeefc16a3b8e10 -rda39893cc4cbd9649756abd36049c1f79b233433 --- AlarmDefs.h (.../AlarmDefs.h) (revision 2ce6e18d25ffa0175703106a2ddeefc16a3b8e10) +++ AlarmDefs.h (.../AlarmDefs.h) (revision da39893cc4cbd9649756abd36049c1f79b233433) @@ -135,7 +135,7 @@ ALARM_ID_DG_FILL_CONDUCTIVITY_OUT_OF_RANGE = 97, ///< DG fill conductivity out of range ALARM_ID_HD_BATTERY_COMM_FAULT = 98, ///< HD battery communication fault ALARM_ID_HD_SYRINGE_PUMP_STALL = 99, ///< HD syringe pump stall alarm - ALARM_ID_AVAILABLE_12 = 100, ///< Available for use + ALARM_ID_DG_COND_SENSORS_INVALID_TEMP_COMP_CAL_RECORD = 100, ///< DG conductivity sensors invalid temperature compensation calibration record ALARM_ID_UI_POST_HD_COMM = 101, ///< UI POST HD communication failure ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE = 102, ///< DG heat disinfect temperature gradient out of range ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID = 103, ///< HD invalid calibration CRC @@ -582,7 +582,7 @@ { ALARM_PRIORITY_LOW, 850, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, ALARM_ID_HD_BATTERY_COMM_FAULT }, { ALARM_PRIORITY_HIGH, 10, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_SYRINGE_PUMP_STALL }, // Priority Rank Fault DGFault Stops ClrIm NoClr NoRes NoRin NoEnd BlkRB BlkET BTSRB BTSET NoBRcr NoDRcr ClrOnly TxLog ID - { ALARM_PRIORITY_LOW, 999, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_AVAILABLE_12 }, + { ALARM_PRIORITY_HIGH, 2, FALSE, TRUE , TRUE , TRUE , FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, TRUE , FALSE, FALSE, ALARM_ID_DG_COND_SENSORS_INVALID_TEMP_COMP_CAL_RECORD }, { ALARM_PRIORITY_HIGH, 0, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_UI_POST_HD_COMM }, { ALARM_PRIORITY_MEDIUM, 600, FALSE, FALSE, TRUE , TRUE , FALSE, TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE }, { ALARM_PRIORITY_HIGH, 1, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, FALSE, FALSE, TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID }, @@ -879,6 +879,7 @@ { 2, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD }, { 2, ALARM_ID_DG_RTC_OR_TIMER_ACCURACY_FAILURE }, { 2, ALARM_ID_DG_TEMPERATURE_SENSORS_INVALID_CAL_RECORD }, + { 2, ALARM_ID_DG_COND_SENSORS_INVALID_TEMP_COMP_CAL_RECORD }, { 10, ALARM_ID_HD_SOFTWARE_FAULT }, { 10, ALARM_ID_HD_BLOOD_PUMP_MC_CURRENT_CHECK }, { 10, ALARM_ID_HD_BLOOD_PUMP_OFF_CHECK }, @@ -1137,7 +1138,6 @@ { 999, ALARM_ID_AVAILABLE_7 }, { 999, ALARM_ID_AVAILABLE_8 }, { 999, ALARM_ID_AVAILABLE_10 }, - { 999, ALARM_ID_AVAILABLE_12 }, { 999, ALARM_ID_AVAILABLE_13 }, { 999, ALARM_ID_AVAILABLE_15 }, { 999, ALARM_ID_AVAILABLE_30 }, @@ -1264,7 +1264,7 @@ { 97 , ALARM_ID_DG_FILL_CONDUCTIVITY_OUT_OF_RANGE , "DG | Conductivity Out of Range | Treatment is currently paused.\n- Confirm that acid and bicarbonate concentrates\nare securely connected.\n- If empty, replace. \n- Treatment will need to be resumed when conductivity\nis within target range. | Dial. Gen: Dialysate Cond. | DG fill conductivity out of range | If the average acid or bicard conductivity is > 5% of the normal acid and bicarb conductivity values. | "}, { 98 , ALARM_ID_HD_BATTERY_COMM_FAULT , "HD | Service Required: Hemodialysis Device | A non- critical problem was detected with the hemodialysis\n device.\n- Call service to report the issue and schedule a repair. | HD Alarm (Low): Battery Com | HD battery or battery charger communication fault | If battery I2C communication fault persistence count > 5. | "}, { 99 , ALARM_ID_HD_SYRINGE_PUMP_STALL , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device. \n- Treatment must be terminated.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD Fault: Syringe Pump Stall | HD syringe pump stall alarm | If syringe pump measured rate < stall speed threshold (0.05) and the ramp up has been restarted 3 times after stall has been detected. | "}, - { 100 , ALARM_ID_AVAILABLE_12 , " | | | | | | "}, + { 100 , ALARM_ID_DG_COND_SENSORS_INVALID_TEMP_COMP_CAL_RECORD , "DG | Service Required: Dialysate Device | A problem was detected with the dialysate device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | DG POST: Conductivity Cal | DG conductivity sensors temperatrue compensation invalid calibration record | If the calibration data that was received from NVDataMgmt is NOT legitimate | "}, { 101 , ALARM_ID_UI_POST_HD_COMM , "UI | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: UI- Proc Comm | UI POST FW Communication failure | If the HD is not communicating with the UI during POST. | "}, { 102 , ALARM_ID_DG_HEAT_DISINFECT_TEMP_GRAD_OUT_OF_RANGE , "DG | Disinfection Interrupted | Disinfection terminated unexpectedly.\n- Restart disinfection.\n- If problem persists, call service to schedule a repair. | Cleaning: Tpo THD Temp Delta | DG heat disinfection temperature gradient out of range | If temperature gradient between Tpo and Thd exceeds maximum 15°C. | "}, { 103 , ALARM_ID_HD_NVDATAMGMT_CAL_GROUP_RECORD_CRC_INVALID , "HD | Service Required: Hemodialysis Device | A problem was detected with the hemodialysis device.\n- Locate the ID code found in the bottom left corner\nof the alarm screen.\n- Call service to report the issue and schedule a repair. | HD POST: Cal NVRAM CRC | HD non-volatile calibration group invalid record CRC | If the computed CRC of the calibration group record is not equal to the record CRC. | "},