Index: AlarmDefs.h =================================================================== diff -u -rbc02b8701f2b46583bfec6ff0a345d27195ff5d9 -rdafd708155e64f8ed646d707bc57b6bc0a375d2a --- AlarmDefs.h (.../AlarmDefs.h) (revision bc02b8701f2b46583bfec6ff0a345d27195ff5d9) +++ AlarmDefs.h (.../AlarmDefs.h) (revision dafd708155e64f8ed646d707bc57b6bc0a375d2a) @@ -871,18 +871,13 @@ { 2, ALARM_ID_DG_INVALID_SERIAL_NUMBER }, { 2, ALARM_ID_DG_LOAD_CELLS_INVALID_CAL_RECORD }, { 3, ALARM_ID_AVAILABLE_61 }, - { 3, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, { 3, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_VENOUS_PRESSURE_SELF_TEST_FAILURE }, { 3, ALARM_ID_DG_CONDUCTIVITY_SENSOR_BAD_STATUS }, { 3, ALARM_ID_HD_VENOUS_BUBBLE_SELF_TEST_FAILURE }, - { 3, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, - { 3, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, { 3, ALARM_ID_ACID_CONDUCTIVITY_OUT_OF_RANGE }, { 3, ALARM_ID_BICARB_CONDUCTIVITY_OUT_OF_RANGE }, - { 3, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE }, - { 3, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_HIGH }, { 3, ALARM_ID_RO_REJECTION_RATIO_OUT_OF_RANGE }, { 3, ALARM_ID_DG_DIALYSATE_FILL_OUT_OF_TIME }, { 3, ALARM_ID_DG_DIALYSATE_TEMPERATURE_SENSORS_OUT_OF_RANGE }, @@ -982,6 +977,7 @@ { 10, ALARM_ID_HD_CPU_RAM_ERROR }, { 10, ALARM_ID_HD_AIR_PUMP_TIMEOUT }, { 10, ALARM_ID_HD_VENOUS_SENSOR_FPGA_FAULT }, + { 10, ALARM_ID_HD_ARTERIAL_SENSOR_FPGA_FAULT }, { 11, ALARM_ID_END_OF_TREATMENT_HIGH }, { 11, ALARM_ID_TREATMENT_STOPPED_NO_RINSEBACK }, { 11, ALARM_ID_VENOUS_PRESSURE_HIGH }, @@ -1043,6 +1039,7 @@ { 110, ALARM_ID_DG_ACID_CONCENTRATE_PUMP_PARK_FAULT }, { 110, ALARM_ID_DG_BICARB_CONCENTRATE_PUMP_PARK_FAULT }, { 110, ALARM_ID_DG_OUTLET_UV_REACTOR_NOT_HEALTHY }, + { 110, ALARM_ID_DG_FLOW_METER_CHECK_FAILURE }, { 111, ALARM_ID_DG_CAN_MESSAGE_NOT_ACKED }, { 111, ALARM_ID_HD_DIALYSATE_FLOW_DATA_NOT_RECEIVE }, { 111, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT }, @@ -1064,6 +1061,9 @@ { 600, ALARM_ID_DG_CHEM_DISINFECT_TARGET_TEMP_OUT_OF_RANGE }, { 600, ALARM_ID_DG_CHEM_DISINFECT_FLUSH_SAMPLE_TIMEOUT }, { 600, ALARM_ID_DG_RESERVOIR_LEAK_TIMEOUT }, + { 600, ALARM_ID_DG_INVALID_LOAD_CELL_VALUE }, + { 600, ALARM_ID_DG_CHEM_DISINFECT_PRIME_ACID_LINE_TIME_OUT }, + { 601, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_HIGH }, { 602, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_TEMP_TOO_LOW }, { 605, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_HIGH }, { 606, ALARM_ID_DG_CLEANING_MODE_INLET_WATER_PRESSURE_TOO_LOW },