Index: AlarmDefs.h =================================================================== diff -u -r4941f31bb12b161f1a39a574976cea966a3108f9 -re7078f1b06211a0eb47cf9236c07b90b035c77e6 --- AlarmDefs.h (.../AlarmDefs.h) (revision 4941f31bb12b161f1a39a574976cea966a3108f9) +++ AlarmDefs.h (.../AlarmDefs.h) (revision e7078f1b06211a0eb47cf9236c07b90b035c77e6) @@ -101,7 +101,7 @@ ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT = 63, ///< FPGA reports failure reading arterial pressure sensor ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT = 64, ///< FPGA reports failure reading venous pressure sensor ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT = 65, ///< HD requests DG command with invalid parameter fault - ALARM_ID____AVAILABLE_21 = 66, ///< This alarm ID is available for use + ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE = 66, ///< HD blood leak sensor set point set failure ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE = 67, ///< HD blood pump occlusion self-test failure alarm ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE = 68, ///< HD active reservoir recirculation out of range ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD = 69, ///< HD blood leak sensor invalid calibration record @@ -510,7 +510,7 @@ { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT, 0, ALARM_ID_NO_ALARM }, - { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID____AVAILABLE_21, 0, ALARM_ID_NO_ALARM }, + { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, TRUE , FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 3, FALSE, FALSE, TRUE , FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, FALSE, ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE, 0, ALARM_ID_NO_ALARM }, { ALARM_PRIORITY_HIGH, 1, FALSE, FALSE, TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , TRUE , FALSE, FALSE, ALARM_ID_HD_BLOOD_LEAK_INVALID_CAL_RECORD, 0, ALARM_ID_NO_ALARM }, @@ -825,7 +825,7 @@ { 3, ALARM_ID_ARTERIAL_PRESSURE_SENSOR_FAULT }, { 3, ALARM_ID_VENOUS_PRESSURE_SENSOR_FAULT }, { 3, ALARM_ID_DG_COMMAND_INVALID_PARAMETER_FAULT }, - { 3, ALARM_ID____AVAILABLE_21 }, + { 3, ALARM_ID_HD_BLOOD_LEAK_SENSOR_SET_POINT_SET_FAILURE }, { 3, ALARM_ID_HD_BP_OCCLUSION_SELF_TEST_FAILURE }, { 3, ALARM_ID_HD_ACTIVE_RESERVOIR_RECIRCULATION_OUT_OF_RANGE }, { 3, ALARM_ID_HD_ARTERIAL_PRESSURE_SELF_TEST_FAILURE },