Index: firmware/App/Controllers/Heaters.c =================================================================== diff -u -rf4a7ca238b4d8fa7ee756ec4dc813c3d0ffa7f84 -r0e084183dc794092c52734b916fcd79dc16829ad --- firmware/App/Controllers/Heaters.c (.../Heaters.c) (revision f4a7ca238b4d8fa7ee756ec4dc813c3d0ffa7f84) +++ firmware/App/Controllers/Heaters.c (.../Heaters.c) (revision 0e084183dc794092c52734b916fcd79dc16829ad) @@ -58,7 +58,7 @@ #define D5_HEAT_TX_P_COEFFICIENT 0.034F ///< P Term for AC primary heater control during treatment mode. #define D5_HEAT_TX_I_COEFFICIENT 0.001F ///< I Term for AC primary heater control during treatment mode. -#define D45_HEAT_P_COEFFICIENT 0.05F //0.01F ///< P Term for trimmer heater control. +#define D45_HEAT_P_COEFFICIENT 0.05F ///< P Term for trimmer heater control. #define D45_HEAT_I_COEFFICIENT 0.0005F ///< I Term for trimmer heater control. #define D45_HEAT_TX_INIT_FEED_FORWARD 0.0F ///< Initial Feed forward term for heater control #define D45_HEAT_HIGHER_QD_P_COEFFICIENT 0.2F ///< P Term for trimmer heater control for higher dialysate flow rate. @@ -106,8 +106,8 @@ #define D5_HEAT_OUT_TX_P_COEFFICIENT 0.5F ///< P Term for AC primary heater outer loop control during treatment mode. #define D5_HEAT_OUT_TX_I_COEFFICIENT 0.4F ///< I Term for AC primary heater outer loop control during treatment mode. #else -#define D5_HEAT_OUT_TX_P_COEFFICIENT 0.75F //2.00F //0.5F ///< P Term for AC primary heater outer loop control during treatment mode. -#define D5_HEAT_OUT_TX_I_COEFFICIENT 0.15F //0.04F //0.08F //0.4F ///< I Term for AC primary heater outer loop control during treatment mode. +#define D5_HEAT_OUT_TX_P_COEFFICIENT 0.75F ///< P Term for AC primary heater outer loop control during treatment mode. +#define D5_HEAT_OUT_TX_I_COEFFICIENT 0.15F ///< I Term for AC primary heater outer loop control during treatment mode. #endif #define D5_HEAT_OUT_LOWQD_TX_P_COEFFICIENT 0.5F ///< P Term for AC primary heater outer loop - low Qd(<200) control during treatment mode. #define D5_HEAT_OUT_LOWQD_TX_I_COEFFICIENT 0.25F ///< I Term for AC primary heater outer loop - low Qd(<200) control during treatment mode. @@ -704,7 +704,7 @@ // Use new RTD sensor placed closed to dialyzer, connected to D1 port measuredTempAtDialyzer = getFilteredTemperatureValue( D1_TEMP ); #else - if ( getTestConfigStatus( TEST_CONFIG_DD_FP_ENABLE_BETA_2_0_HW ) != TRUE ) + if ( getTestConfigStatus( TEST_CONFIG_DD_FP_ENABLE_BETA_1_9_HW ) == TRUE ) { measuredTempAtDialyzer = getTeensyConductivityTemperatureValue( D27_COND ); }