Index: firmware/App/Modes/FPModes/FlushConcentrate.c =================================================================== diff -u -rb9084c526c8ab28a605f4d2640288e2fc80796ff -rbadf38264b5f9f238d46d860f165b1e1bb4311b7 --- firmware/App/Modes/FPModes/FlushConcentrate.c (.../FlushConcentrate.c) (revision b9084c526c8ab28a605f4d2640288e2fc80796ff) +++ firmware/App/Modes/FPModes/FlushConcentrate.c (.../FlushConcentrate.c) (revision badf38264b5f9f238d46d860f165b1e1bb4311b7) @@ -29,6 +29,7 @@ #include "TaskGeneral.h" #include "Timers.h" #include "Valves.h" +#include "WaterQualityMonitor.h" /** * @addtogroup FPConcentrateFlush @@ -40,7 +41,7 @@ #define CONCENTRATE_FLUSH_MAX_TIMEOUT ( 600 * MS_PER_SECOND ) ///< Max override timeout for 10 minutes #define CONCENTRATE_FLUSH_DATA_PUBLISH_INTERVAL ( MS_PER_SECOND / TASK_GENERAL_INTERVAL ) ///< Interval (ms/task time) at which the gen water mode data published. #define CONCENTRATE_FLUSH_TIMEOUT ( 30 * MS_PER_SECOND ) ///< Concentrate flush timer (in ms) -#define CONCENTRATE_FLUSH_RO_PUMP_TGT_PWM 0.75F ///< target in PWM % for the RO pump during concentrate flush. +#define CONCENTRATE_FLUSH_RO_PUMP_TGT_PWM 0.8F ///< target in PWM % for the RO pump during concentrate flush. #define CONCENTRATE_FLUSH_BOOST_PUMP_TGT_PSI 25 ///< Pressure target in PSI for the boost pump during concentrate flush. #define CONCENTRATE_FLUSH_VOLUME_THRESHOLD_ML 1000.0F ///< Integrated volume threshold in ml #define CONCENTRATE_FLUSH_VOLUME_THRESHOLD_PCT 0.9F ///< Integrated volume threshold percentage @@ -175,6 +176,8 @@ setBoostPumpTargetPressure( CONCENTRATE_FLUSH_BOOST_PUMP_TGT_PSI ); isTankFilled = FALSE; } + + checkROInletPressure(); } return state;